2A9NJP557GATOR HEAD

KVD DEVELOPMENTS LIMITED.
GATOR HEAD - FCC ID 2A9NJP557 - KVD DEVELOPMENTS LIMITED.
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Jan 05, 2023
Application Purpose
Original Equipment
Date of Application
Jan 04, 2023
Equipment Note
GATOR HEAD
Frequency Range
2405.00000000 - 2475.00000000
Company
KVD DEVELOPMENTS LIMITED.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

Antenna Information: Manufacturer: Shenzhen Quanshuang electric Co.,Ltd. Model: PB557 Dimensions: (unit: mm) Photo: Gain: Integral antenna with maximum gain 1.5dBi

ID Label/Location Info

Item No.:PB557 Battery type:2xAAA FCC ID:2A9NJP557 Made in China

ID Label/Location Info

Label Location

RF Exposure Info

Acc eir whe pt gt E = d = Sop Ant Fie So <2 . The ording to p = pt x re: = transmi = numeri c = electric = measurem t = (EXd) t gain = eld stre Pt={ [1 .73 mW n SAR eva o 447498 D gt = (EXd tter outp c gain of c field st ment dista 2 /30 x gt =1.5dBi ngth =8 0 0 (80.88/20) aluation i RF Expo D04 Interi d) 2 /30 put power the tran s trength in ance in me so Ant n 0.88dBμV /10 6 x3 s not req osure eval im General in watts, smitting a n V/m, --- eters (m)- numeric V/m @3m@2 3] 2 /30x1. quired luation l RF Expos antenna (u - 10 ((dBuV ---3m gain= 1. 2475MHz .413}x100 sure Guida unitless), V/m)/20) /10 6 .413 00 mW = ance v01 0.03mW

Test Report

Report No.: TW2211287E Applicant: KVD DEVELOPMENTS LIMITED. Product: GATOR HEAD Model No.: PB557 Trademark: N/A Test Standards: FCC Part 15.249 Test result: It is herewith confirmed and found to comply with the requirements set up by ANSI C63.10 & FCC Part 15 Subpart C, Paragraph 15.249 regulations for the evaluation of electromagnetic compatibility Approved By Terry Tang Manager Dated: December 01, 2022 Results appearing herein relate only to the sample tested The technical reports is issued errors and omissions exempt and is subject to withdrawal at SHENZHEN TIMEWAY TESTING LABORATORIES Zone C, 1st Floor, Block B, Jun Xiang Da Building, Zhongshan Park Road West, Tong Le Village, Nanshan District, Shenzhen, China Tel (755) 83448688, Fax (755) 83442996, E-Mail:[email protected] Report No.: TW2211287E Page 2 of 36 Date: 2022-12-01 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Special Statement: The testing quality ability of our laboratory meet with "Quality Law of People's Republic of China" Clause 19. The testing quality system of our laboratory meet with ISO/IEC-17025 requirements, which is approved by CNAS. This approval result is accepted by MRA of APLAC. Our test facility is recognized, certified, or accredited by the following organizations: CNAS-LAB Code: L2292 The EMC Laboratory has been assessed and in compliance with CNAS-CL01 accreditation criteria for testing Laboratories (identical to ISO/IEC 17025:2017 General Requirements) for the Competence of testing Laboratories. FCC-Registration No.: 744189 The EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications commission. The acceptance letter from the FCC is maintained in our files. Registration No.: 744189. Industry Canada (IC) —Registration No.:5205A The EMC Laboratory has been registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 5205A. A2LA (Certification Number:5013.01) The EMC Laboratory has been accredited by the American Association for Laboratory Accreditation (A2LA). Certification Number:5013.01 Report No.: TW2211287E Page 3 of 36 Date: 2022-12-01 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Test Report Conclusion Content 1.0 General Details ............................................................................................... 4 1.1 Test Lab Details............................................................................................... 4 1.2 Applicant Details.............................................................................................. 4 1.3 Description of EUT .......................................................................................... 4 1.4 Submitted Sample............................................................................................. 4 1.5 Test Duration................................................................................................... 5 1.6 Test Uncertainty................................................................................................ 5 1.7 Test By......................................................................................................... 5 2.0 List of Measurement Equipment......................................................................... 6 3.0 Technical Details............................................................................................. 7 3.1 Summary of Test Results.................................................................................... 7 3.2 Test Standards................................................................................................. 7 4.0 EUT Modification............................................................................................. 7 5.0 Power Line Conducted Emission Test..................................................................... 8 5.1 Schematics of the Test....................................................................................... 8 5.2 Test Method and Test Procedure............................................................................ 8 5.3 Configuration of the EUT................................................................................... 8 5.4 EUT Operating Condition.........................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Radiated Emission Test Setup:

Contact Information

Applicant

Derick Shahani(Managing Director)
[email protected]+(852) 31699817Fax: (852) 31699820

Test Firm

Shenzhen Timeway Testing LaboratoriesTerry Tang
[email protected]+86-755-83448688

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz-
Confidentiality
Long Term