Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Rev 1/26/2023 Foshan Alpicool Holding Group Co., Ltd. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 12-10-2025 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2A9O8-C9 Foshan Alpicool Holding Group Co., Ltd.(“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Foshan Alpicool Holding Group Co., Ltd.(“the applicant”) certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24- 886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Device is inherently compliant based on hardware limitations or software controls. or A Software Bill of Materials (SBOM) is provided to the TCB for review, and The end-user or third parties cannot install additional software on this device. Sincerely, (Applicant signature) Fan Gangqiang Rev 1/26/2023 Foshan Alpicool Holding Group Co., Ltd. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 12-10-2025 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID:2A9O8-C9 Foshan Alpicool Holding Group Co., Ltd.(“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, (Applicant signature) Fan Gangqiang
Foshan Alpicool Holding Group Co., Ltd. Date:December 10, 2025 Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID:2A9O8-C9 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Schematics Block Diagram Operational Description Schematic.pdf Block Diagram.pdf Operational Description.pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Foshan Alpicool Holding Group Co., Ltd. Signature Fan Gangqiang/Manager Typed name and Title
Foshan Alpicool Holding Group Co., Ltd. Difference Declaration Date: 2025.12.3 We, Foshan Alpicool Holding Group Co., Ltd. declare that the following models are identical in circuit design, wiring system, circuit board size and internal wiring except for the difference in appearance, color. Models: C9, CF8, CF15, NL30, NL40, NL50, NLD35, NLD45, NLD55, NLS35, NLS45, NLS55, C15, C20, C75, CX30, CX40, CX50, CF35, CF45, CF55 Sincerely Foshan Alpicool Holding Group Co., Ltd. Signature Fan Gangqiang / Manager Typed name and Title
Foshan Alpicool Holding Group Co., Ltd. FCC ID: 2A9O8-C9 POWER OF ATTORNEY Date: December 3, 2025 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 To Whom It May Concern: We, the undersigned, hereby authorize Waltek Testing Group (Foshan) Co., Ltd. (Dara Zhou) on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by Waltek Testing Group (Foshan) Co., Ltd. (Dara Zhou) on our behalf shall have the same effect as acts of our own. This authorization expires on December 3, 2026 . This is to advise that we are in full compliance with the Anti-Drug Abuse Act. We, Foshan Alpicool Holding Group Co., Ltd. are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Sincerely, Foshan Alpicool Holding Group Co., Ltd. Signature Fan Gangqiang/Manager Typed name and Title
Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Reference No.: WTA25F11289588W Page 1 of 4 Picture 1 Picture 2 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Reference No.: WTA25F11289588W Page 2 of 4 Picture 3 Picture 4 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Reference No.: WTA25F11289588W Page 3 of 4 Picture 5 Picture 6 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Reference No.: WTA25F11289588W Page 4 of 4 Picture 7
Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Reference No.: WTA25F11289588W Page 1 of 5 Picture 1 Picture 2 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Reference No.: WTA25F11289588W Page 2 of 5 Picture 3 Picture 4 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Reference No.: WTA25F11289588W Page 3 of 5 Picture 5 Picture 6
Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Reference No.: WTA25F11289588W Page 4 of 5 Picture 7 Picture 8 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Reference No.: WTA25F11289588W Page 5 of 5 Picture 9 Picture 10
Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn RF Exposure Requirements 1 General Information Client Information Applicant ....................................... : Foshan Alpicool Holding Group Co., Ltd. Address of applicant ................... : No.3, ZhenZhu Road, Yang’e, Lunjiao , Shunde, Foshan, Guangdong, China Manufacturer ................................. : The same as above Address of manufacturer ............. : The same as above General Description of E.U.T FCC ID ............................................ : 2A9O8-C9 Product Name ............................... : Car Refrigertor Model No. ..................................... : C9, CF8, CF15, NL30, NL40, NL50, NLD35, NLD45, NLD55, NLS35, NLS45, NLS55, C15, C20, C75, CX30, CX40, CX50, CF35, CF45, CF55 Model Description ........................ : All models are identical except appearance and capacity. Rated Voltage ................................ : DC 12V/24V Battery Capacity ........................... : --- Power Adapter .............................. : GRT60-145410 Input: 100-240V~, 1.5A Max, 50/60Hz; Output: DC 14.5V, 4.1A, 59.45W Technical Characteristics of EUT Bluetooth Version ......................... : Bluetooth LE Frequency Range ......................... : 2402-2480MHz RF Output Power .......................... : -1.880dBm (Conducted) Modulation .................................... : GFSK Data Rate ....................................... : 1Mbps Quantity of Channels ................... : 40 Channel Separation ...................... : 2MHz Type of Antenna ........................... : PCB Antenna Antenna Gain ................................ : -2.41dBi Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn 2 Applicable Standard According to §1.1307(b)(1) and KDB 447498 D01 General RF Exposure Guidance v06, system operating under the provisions of this section shall be operating in a manner that the public is not exposed to radio frequency energy level in excess limit for maximum permissible exposure. (a) Limits for Occupational / Controlled Exposure Frequency range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm 2 ) Averaging Times | E | 2 , | H | 2 or S (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842/f 4.89/f (900/f)* 6 30-300 61.4 0.163 1.0 6 300-1500 / / F/300 6 1500-100000 / / 5 6 (b) Limits for General Population / Uncontrolled Exposure Frequency range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm 2 ) Averaging Times | E | 2 , | H | 2 or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180/f)* 30 30-300 27.5 0.073 0.2 30 300-1500 / / F/1500 30 1500-100000 / / 1 30 Note: f = frequency in MHz: * = Plane-wave equivalents power density 3 Calculation Method S = (30*P*G) / (377*R 2 ) S = power density (in appropriate units, e.g., mw/cm 2 ) P = power input to the antenna (in appropriate units, e.g., mw) G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain factor is normally numeric gain. R = distance to the center of radiation of the antenna (in appropriate units, e.g., cm), R=20cm. 4 MPE Calculation Result Frequency (MHz) Antenna Gain (dBi) Numeric gain Conducted Power (dBm) Maximum Tune-up output power PD (mW/cm2) Limit (mW/cm2) (dBm) (mW) 2402-2480 -2.41 0.57 -1.88 -1.00 0.79 0.00009 1.0 Result: Pass ======End of Report======
Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn Page 1 of 15 TEST REPORT Reference No. .................... : WTA25X12344079W Applicant ........................... : Foshan Alpicool Holding Group Co., Ltd. Address.............................. : No.3, ZhenZhu Road, Yang’e, Lunjiao , Shunde, Foshan, Guangdong, China Manufacturer ..................... : Foshan Alpicool Holding Group Co., Ltd. Address.............................. : No.3, ZhenZhu Road, Yang’e, Lunjiao , Shunde, Foshan, Guangdong, China Product Name ................... : Car Refrigertor Model No... ......................... : C9 Standards .......................... : ANSI/ IEEE 149-2021 Date of Receipt sample .... : 2025-12-23 Date of Test........................ : 2025-12-23 to 2026-01-07 Date of Issue ..................... : 2026-01-07 Test Report Form No. ....... : WTX_IEEE 149 Test Result ......................... : Pass Remarks: The results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of approver. Prepared By: Waltek Testing Group (Shenzhen) Co., Ltd. Address: 1/F., Room 101, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Block 70 Bao'an District, Shenzhen, Guangdong, China Tel.: +86-755-33663308 Fax.: +86-755-33663309 Email: [email protected] Tested by: Approved by: Gala Wang/Project Engineer Jason Su/Manager Reference No.: WTA25X12344079W Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn Page 2 of 15 TABLE OF CONTENTS 1.GENERAL INFORMATION ....................................................................................................................................4 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ...............................................................................4 2. SUMMARY OF TEST RESULTS ...........................................................................................................................5 3. ANTENNA TEST CONFIGURATIONS ................................................................................................................6 3.1 TEST LOCATION .....................................................................................................................................................6 3.2 TEST ENVIRONMENTS.............................................................................................................................................6 3.3 TEST EQUIPMENT LIST ...........................................................................................................................................6 3.4 MEASUREMENT UNCERTAINTY ..............................................................................................................................6 3.5 TEST SETUP ............................................................................................................................................................6 4. ANTENNA TEST RESULT .....................................................................................................................................7 4.1 GAIN AND EFFICIENCY ...........................................................................................................................................7 4.2 RADIATION PATTERN 2D VIEW ...............................................................................................................................9 4.3 RADIATION PATTERN 3D VIEW ............................................................................................................................. 11 EXHIBIT 1 - TEST SETUP PHOTOGRAPHS ........................................................................................................ 15 Reference No.: WTA25X12344079W Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn Page 3 of 15 Report version Version No. Date of issue Description Rev.00 2026-01-07 Original / / / Reference No.: WTA25X12344079W Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn Page 4 of 15 1.GENERAL INFORMATION 1.1 Product Description for Equipment Under Test (EUT) General Description of EUT Product Name: Car Refrigertor Trade Name: / Model No.: C9 Adding Model(s): CF8, CF15, NL30, NL40, NL50, NLD35, NLD45, NLD55, NLS35, NLS45, NLS55, C15, C20, C75, CX30, CX40, CX50, CF35, CF45CF55 Note: The test data is gathered from a production sample, provided by the manufacturer. The appearance of others models listed in the report is different from main-test model C9, but the circuit and the electronic construction do not change, declared by the manufacturer. Technical Characteristics of EUT Frequency Range: 2400-6000MHz Gain of Antenna: 3.93dBi (Max.) Type of Antenna: PCB Antenna Dimension: Reference No.: WTA25X12344079W Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn Page 5 of 15 2. SUMMARY OF TEST RESULTS Standards Description of Test Item Result ANSI/ IEEE 149-2021 IEEE Recommended Practice for Antenna Measurements Compliant N/A: not applicable Reference No.: WTA25X12344079W Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn Page 6 of 15 3. Antenna Test Configurations 3.1 Test Location Name: Sushi TOWE Wireless Testing(Shenzhen)Co., Ltd. Address: F 401/101, Building E, Hongwei Industrial Zone, No. 6, Liuxian 3rd Road, Bao'an District, Shenzhen,518133 3.2 Test Environments Environments Parameter Temperature Voltage Humidity NTNV 25 C -- 50% 3.3 Test Equipment List Description Manufacturer Model Serial Number Cal. Date Due. Date Anechoic Chamber ETS AMS8923 Q2225 2023-06-09 2028-06-08 RF Switch ETS EMCenter 251211 / / Vector network analyzer R&S ZNB8 101413 2025-07-15 2026-07-14 3.4 Measurement Uncertainty The uncertainty is calculated using the methods suggested in the“Guide to the Expression of Uncertainty in Measurement" (GUM) published by ISO. When the…
Text truncated - open the document above for the full version.
Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Page 1 of 38 WT-510-201-12-A TEST REPORT Reference No. .................... : WTA25F11289588W FCC ID ................................ : 2A9O8-C9 Applicant ............................ : Foshan Alpicool Holding Group Co., Ltd. Address .............................. : No.3, ZhenZhu Road, Yang’e, Lunjiao , Shunde, Foshan, Guangdong, China Manufacturer .................... : The same as above Address .............................. : The same as above Product Name .................... : Car Refrigertor Model No. ........................... : C9, CF8, CF15, NL30, NL40, NL50, NLD35, NLD45, NLD55, NLS35, NLS45, NLS55, C15, C20, C75, CX30, CX40, CX50, CF35, CF45, CF55 Test specification .............. : FCC CFR47 Part 15 Subpart C (Section 15.247) Date of Receipt sample .... : 2025-11-06 Date of Test ....................... : 2025-11-07 to 2025-11-14 Date of Issue ...................... : 2025-12-12 Test Report Form No. ....... : WEW-15247A-01B Test Result ......................... : Pass Remarks: The results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of approver. Prepared By: Waltek Testing Group (Foshan) Co., Ltd. Address: 1/F., Building 19, Sunlink Machinery City, Xingye 4 Road, Guanglong Industrial Park, Chihua Neighborhood Committee, Chencun, Shunde District, Foshan, Guangdong, China Tel:+86-757-23811398 Fax:+86-757-23811381 E-mail:[email protected] Tested by: Approved by: Roy Hong Danny Zhou Reference No.: WTA25F11289588W Page 2 of 38 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn WT-510-201-12-A 1 Revision History Test Report No. Date of Issue Description Status WTA25F11289588W 2025-12-12 Original Valid Reference No.: WTA25F11289588W Page 3 of 38 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn WT-510-201-12-A 2 Contents Page 1 REVISION HISTORY ................................................................................................................................. 2 2 CONTENTS ............................................................................................................................................... 3 3 GENERAL INFORMATION ....................................................................................................................... 4 3.1 GENERAL DESCRIPTION OF E.U.T ................................................................................................... 4 3.2 TECHNICAL CHARACTERISTICS OF EUT ........................................................................................... 4 3.3 STANDARDS APPLICABLE FOR TESTING ............................................................................................ 4 3.4 TEST FACILITY ................................................................................................................................ 5 3.5 SUBCONTRACTED ........................................................................................................................... 5 3.6 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................ 5 3.7 DISCLAIMER .................................................................................................................................... 5 4 EUT SETUP AND TEST MODE ................................................................................................................ 6 5 EQUIPMENT USED DURING TEST ......................................................................................................... 7 5.1 EQUIPMENT LIST ............................................................................................................................. 7 5.2 TEST SOFTWARE ............................................................................................................................ 8 5.3 SPECIAL ACCESSORIES AND AUXILIARY EQUIPMENT ......................................................................... 8 5.4 MEASUREMENT UNCERTAINTY ......................................................................................................... 8 6 SUMMARY OF TEST RESULT ................................................................................................................ 9 6.1 ANTENNA REQUIREMENT ............................................................................................................... 10 6.2 RADIATED SPURIOUS EMISSIONS ................................................................................................... 11 6.3 POWER SPECTRAL DENSITY .......................................................................................................... 21 6.4 DTS BANDWIDTH .......................................................................................................................... 23 6.5 RF OUTPUT POWER ...................................................................................................................... 25 6.6 OUT OF BAND EMISSIONS .............................................................................................................. 27 6.7 CONDUCTED EMISSIONS................................................................................................................ 32 7 PHOTOGRAPHS TEST SETUP ............................................................................................................. 36 7.1 PHOTOGRAPHS - RADIATED EMISSION TEST SETUP ........................................................................ 36 7.2 PHOTOGRAPHS – CONDUCTED EMISSION TEST SETUP ................................................................... 37 8 PHOTOGRAPHS – EUT CONSTRUCTIONAL DETAILS ...................................................................... 38 Reference No.: WTA25F11289588W Page 4 of 38 Waltek Testing Group (Foshan)…
Text truncated - open the document above for the full version.
Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Reference No.: WTA25F11289588W Page 1 of 2 Test Setup For Radiated Emission (30MHz to 1GHz) Test Setup For Radiated Emission (Above 1GHz) Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Reference No.: WTA25F11289588W Page 2 of 2 Test Setup For Conducted Emission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 600.00 µW |

Car Refrigerator
Equipment Class
DTS - Digital Transmission System
Car Refrigerator
Equipment Class
DTS - Digital Transmission System
Car Refrigerator
Equipment Class
DTS - Digital Transmission System