FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Ultimea Technology (Shenzhen) Limited/
  3. 2A9OO-UC001S

2A9OO-UC001SSoundbar

Ultimea Technology (Shenzhen) Limited
Soundbar - FCC ID 2A9OO-UC001S - Ultimea Technology (Shenzhen) Limited
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Aug 12, 2026
Application Purpose
Original Equipment
Equipment Note
Soundbar
Frequency Range
2402.00000000 - 2480.00000000
Company
Ultimea Technology (Shenzhen) Limited
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Internal Photos

Photographs-EUTConstructionalDetails BT8961B6FPCAntenna PCBAntennisnotused,Itwasturnedoffbythesoftware. RTL8730ELHFPCantenna

Test Setup Photos

1Photographs-EUTTestSetup 1.1RadiatedSpuriousEmission 9kHz~30MHz: 30MHz~1GHz: Above1GHz: 1.2 ConductedEmission 1.3 RFConductedmeasurement

Test Report

CQASZ20260500916E-01 AppendixA:Maximumconductedoutputpower Ant1: TestResultPeak Test Mode AntennaFreq(MHz) ConductedPeak Powert[dBm] Conducted Limit[dBm] Verdict DH5Ant1 24023.98≤30PASS 24413.96≤30PASS 24804.00≤30PASS 2DH5Ant1 24025.98≤30PASS 24415.89≤30PASS 24805.99≤30PASS 3DH5Ant1 24026.29≤30PASS 24416.18≤30PASS 24806.31≤30PASS TestGraphs DH5_Ant1_2402 A Att 40 dB* Offset 0.2 dB LVL Ref 30 dBm * * 3DB RBW 3 MHz VBW 10 MHz SWT 5 ms Center2.402 GHzSpan8 MHz800 kHz/ 1 PK MAXH SGL -70 -60 -50 -40 -30 -20 -10 0 10 20 30 SWP 100 of 100 1 Marker 1 [T1 ] 3.98 dBm 2.401912000 GHz Date: 30.JUL.2026 11:25:56 DH5_Ant1_2441 A Att 40 dB* Offset 0.2 dB LVL Ref 30 dBm * * 3DB RBW 3 MHz VBW 10 MHz SWT 5 ms Center2.441 GHzSpan8 MHz800 kHz/ 1 PK MAXH SGL -70 -60 -50 -40 -30 -20 -10 0 10 20 30 SWP 100 of 100 1 Marker 1 [T1 ] 3.96 dBm 2.441064000 GHz Date: 30.JUL.2026 11:26:56 DH5_Ant1_2480 A Att 40 dB* Offset 0.2 dB LVL Ref 30 dBm * * 3DB RBW 3 MHz VBW 10 MHz SWT 5 ms Center2.48 GHzSpan8 MHz800 kHz/ 1 PK MAXH SGL -70 -60 -50 -40 -30 -20 -10 0 10 20 30 SWP 100 of 100 1 Marker 1 [T1 ] 4.00 dBm 2.480088000 GHz Date: 30.JUL.2026 11:27:12 2DH5_Ant1_2402 A Att 40 dB* Offset 0.2 dB LVL Ref 30 dBm * * 3DB RBW 3 MHz VBW 10 MHz SWT 5 ms Center2.402 GHzSpan8 MHz800 kHz/ 1 PK MAXH SGL -70 -60 -50 -40 -30 -20 -10 0 10 20 30 SWP 100 of 100 1 Marker 1 [T1 ] 5.98 dBm 2.401888000 GHz Date: 30.JUL.2026 11:28:11 2DH5_Ant1_2441 A Att 40 dB* Offset 0.2 dB LVL Ref 30 dBm * * 3DB RBW 3 MHz VBW 10 MHz SWT 5 ms Center2.441 GHzSpan8 MHz800 kHz/ 1 PK MAXH SGL -70 -60 -50 -40 -30 -20 -10 0 10 20 30 SWP 100 of 100 1 Marker 1 [T1 ] 5.89 dBm 2.440824000 GHz Date: 30.JUL.2026 11:29:21 2DH5_Ant1_2480 A Att 40 dB* Offset 0.2 dB LVL Ref 30 dBm * * 3DB RBW 3 MHz VBW 10 MHz SWT 5 ms Center2.48 GHzSpan8 MHz800 kHz/ 1 PK MAXH SGL -70 -60 -50 -40 -30 -20 -10 0 10 20 30 SWP 100 of 100 1 Marker 1 [T1 ] 5.99 dBm 2.479936000 GHz Date: 30.JUL.2026 11:29:45 3DH5_Ant1_2402 A Att 40 dB* Offset 0.2 dB LVL Ref 30 dBm * * 3DB RBW 3 MHz VBW 10 MHz SWT 5 ms Center2.402 GHzSpan8 MHz800 kHz/ 1 PK MAXH SGL -70 -60 -50 -40 -30 -20 -10 0 10 20 30 SWP 100 of 100 1 Marker 1 [T1 ] 6.29 dBm 2.402040000 GHz Date: 30.JUL.2026 11:31:41 3DH5_Ant1_2441 A Att 40 dB* Offset 0.2 dB LVL Ref 30 dBm * * 3DB RBW 3 MHz VBW 10 MHz SWT 5 ms Center2.441 GHzSpan8 MHz800 kHz/ 1 PK MAXH SGL -70 -60 -50 -40 -30 -20 -10 0 10 20 30 SWP 100 of 100 1 Marker 1 [T1 ] 6.18 dBm 2.440952000 GHz Date: 30.JUL.2026 11:31:57 3DH5_Ant1_2480 A Att 40 dB* Offset 0.2 dB LVL Ref 30 dBm * * 3DB RBW 3 MHz VBW 10 MHz SWT 5 ms Center2.48 GHzSpan8 MHz800 kHz/ 1 PK MAXH SGL -70 -60 -50 -40 -30 -20 -10 0 10 20 30 SWP 100 of 100 1 Marker 1 [T1 ] 6.31 dBm 2.479944000 GHz Date: 30.JUL.2026 11:32:17 Ant2: TestResultPeak Test Mode AntennaFreq(MHz) ConductedPeak Powert[dBm] Conducted Limit[dBm] Verdict DH5Ant1 24023.98≤30PASS 24413.85≤30PASS 24803.80≤30PASS 2DH5Ant1 24025.98≤30PASS 24415.76≤30PASS 24805.82≤30PASS 3DH5Ant1 24026.27≤30PASS 24416.08≤30PASS 24806.11≤30PASS TestGraphs DH5_Ant1_2402 A Att 40 dB* Offset 0.2 dB LVL Ref 30 dBm * * 3DB RBW 3 MHz VBW 10 MHz SWT 5 ms Center2.402 GHzSpan8 MHz800 kHz/ 1 PK MAXH SGL -70 -60 -50 -40 -30 -20 -10 0 10 20 30 SWP 100 of 100 1 Marker 1 [T1 ] 3.98 dBm 2.402080000 GHz Date: 28.JUL.2026 10:15:48 DH5_Ant1_2441 A Att 40 dB* Offset 0.2 dB LVL Ref 30 dBm * * 3DB RBW 3 MHz VBW 10 MHz SWT 5 ms Center2.441 GHzSpan8 MHz800 kHz/ 1 PK MAXH SGL -70 -60 -50 -40 -30 -20 -10 0 10 20 30 SWP 100 of 100 1 Marker 1 [T1 ] 3.85 dBm 2.440864000 GHz Date: 28.JUL.2026 10:16:04 DH5_Ant1_2480 A Att 40 dB* Offset 0.2 dB LVL Ref 30 dBm * * 3DB RBW 3 MHz VBW 10 MHz SWT 5 ms Center2.48 GHzSpan8 MHz800 kHz/ 1 PK MAXH SGL -70 -60 -50 -40 -30 -20 -10 0 10 20 30 SWP 100 of 100 1 Marker 1 [T1 ] 3.80 dBm 2.479984000 GHz Date: 28.JUL.2026 10:16:19 2DH5_Ant1_2402 A Att 40 dB* Offset 0.2 dB LVL Ref 30 dBm * * 3DB RBW 3 MHz VBW 10 MHz SWT 5 ms Center2.402 GHzSpan8 MHz800 kHz/ 1 PK MAXH SGL -70 -60 -50 -40 -30 -20 -10 0 10 20 30 SWP 100 of 100 1 Marker 1 [T1 ] 5.98 dBm 2.401760000 GHz Date: 28.JUL.2026 10:16:39 2DH5_Ant1_2441 A Att 40 dB* Offset 0.2 dB LVL Ref 30 dBm * * 3DB RBW 3 MHz VBW 10 MHz SWT 5 ms Center2.441 GHzSpan8 MHz800 kHz/ 1 PK MAXH SGL -70 -60 -50 -40 -30 -20 -10 0 10 20 30 SWP 100 of 100 1 Marker 1 [T1 ] 5.76 dBm 2.440864000 GHz Date: 28.JUL.2026 10:16:53 2DH5_Ant1_2480 A Att 40 dB* Offset 0.2 dB LVL Ref 30 dBm * * 3DB RBW 3 MHz VBW 10 MHz SWT 5 ms Center2.48 GHzSpan8 MHz800 kHz/ 1 PK MAXH SGL -70 -60 -50 -40 -30 -20 -10 0 10 20 30 SWP 100 of 100 1 Marker 1 [T1 ] 5.82 dBm 2.479872000 GHz Date: 28.JUL.2026 10:17:06 3DH5_Ant1_2402 A Att 40 dB* Offset 0.2 dB LVL Ref 30 dBm * * 3DB RBW 3 MHz VBW 10 MHz SWT 5 ms Center2.402 GHzSpan8 MHz800 kHz/ 1 PK MAXH SGL -70 -60 -50 -40 -30 -20 -10 0 10 20 30 SWP 100 of 100 1 Marker 1 [T1 ] 6.27 dBm 2.401960000 GHz Date: 28.JUL.2026 10:17:22 3DH5_Ant1_2441 A Att 40 dB* Offset 0.2 dB LVL Ref 30 dBm * * 3DB RBW 3 MHz VBW 10 MHz SWT 5 ms Center2.441 GHzSpan8 MHz800 kHz/ 1 PK MAXH SGL -70 -60 -50 -40 -30 -20 -10 0 10 20 30 SWP 100 of 100 1 Marker 1 [T1 ] 6.08 dBm 2.440992000 GHz Date: 28.JUL.2026 10:17:38 3DH5_Ant1_2480 A Att 40 dB* Offset 0.2 dB LVL Ref 30 dBm * * 3DB RBW 3 MHz VBW 10 MHz SWT 5 ms Center2.48 GHzSpan8 MHz800 kHz/ 1 PK MAXH SGL -70 -60 -50 -40 -30 -20 -10 0 10 20 30 SWP 100 of 100 1 Marker 1 [T1 ] 6.11 dBm 2.479984000 GHz Date: 28.JUL.2026 10:17:52

Test Report

Repor t No.: WT248001431 Page 1/ 11 ANTENNA TEST REPORT For Auria Model Number: FS2345 Report Number : WT248001431 Test Laboratory : Shenzhen Academy of Metrology and Quality Inspection Site Location : No.4, Tongfa Road, Xili Street, Nanshan District, Shenzhen, Guangdong, China Tel : 0086-755-86928965 Fax : 0086-755-86009898-31396 Web : www.smq.com.cn 重 要 声 明 Important statement 1.本院是深圳市人民政府依法设置的产品质量监督检验机构,系社会公益型非营利性技术机构,为各级 政府执法部门进行监督管理提供技术支持和接受社会各界的委托检验。 SMQ is a legal non-profit technical institute established by Shenzhen Municipal Government to undertake the quality supervision and inspection of products, and to provide technical support to relevant supervision and administration and also conduct commission test from the society. 2.本院保证检验的科学性、公正性和准确性,对检验的数据负责,并对委托单位所提供的样品和技术资 料保密。 SMQ is committed to assuring the scientificness, impartiality and accuracy of all tests carried out, responsibility for test data gained, and keeping confidential of all test samples and technical documents provided. 3.抽样按照本院程序文件《抽样程序》和相应产品的检验细则的规定执行。 The sampling should be carried out according to the "sampling procedure" defined in the Procedure Document and relevant testing specifications. 4.报告/证书无主检、审核、批准人签字,或涂改,或未盖本院报告/证书专用章及骑缝章无效。未经本 院许可,不得部分复印、摘用或篡改本报告/证书内容。复印证书/报告未重新加盖本院证书/报告专用章 无效。 Any report/certificate having not been signed by relevant responsible engineer, reviewer or authorized approver, or having been altered without authorization, or without both the Dedicated Report/Certificate Seal and its across-page seal is deemed to be invalid. Copying or excerpting portion of, or altering the content of the report/certificate is not permitted without the written authorization of SMQ. Any copy of certificates/reports without the Dedicated Report/Certificate Seal is deemed to be invalid. 5.送样委托检验结果仅对来样有效:委托检验的样品、样品及委托方信息均由委托方提供,本院不对样 品的代表性、真实性及信息的完整性和准确性负责。 The test results presented in the report apply only to the tested sample. The customer provides thier own information, the sample, and the sample information. Thus, SMQ assumes no responsibility for representativeness , authenticity of the sample and validity and accuracy of the information.. 6.未经检验机构同意,样品委托人不得擅自使用检验结果进行不当宣传。 Any use of SMQ test result for advertisement of the tested material or product must be approved in writing by SMQ. 7.无CMA标志的报告/证书,仅作为科研、教学或内部质量控制之用。含粤字编号的CAL标志仅适用于产 品标准和判定标准。 The non-CMA report/certificate issued by SMQ is only permitted to be used for research, teaching or internal quality control. CAL logo with symbol "Yue" is only relevant to product standards and reference of standards. 8.委托方对报告/证书有异议的,应于报告发出之日起十五日内向本院提出。政府行政管理部门下达的监 督检验任务,受检方对报告/证书有异议的,应按政府行政管理部门文件规定及国家相关法律、法规进行。 Any objection to report/certificate issued by SMQ should be submitted to SMQ within 15 days after the issuance of the test. The mandatory inspection assigned by government administrative departments shall be carried out in accordance with the documents and regulations of the government administrative department and relevant national laws and regulations if inspected parties raise any objection to the inspection. 9.报告/证书更改后,发出的电子版报告/证书、报告/证书的扫描件及传真件将不被追回,委托方有义务 将更改后的报告/证书提供给使用原报告/证书的相关方。 SMQ is not responsible for recalling the electronic version of the original report/certificate when any revision is made to them. The applicant assumes the responsibility of providing the revised version to any interested party who uses them. 10. 只申领电子报告时,相关内容和效力以电子报告为准;电子报告和纸质报告同时申领时,电子报告仅 作为纸质报告的副本,相关内容和效力以同编号纸质报告为准。 The relevant content and effectiveness is subject to the electronic version of the original report which was only applied for.When an electronic report and a paper report are applied for at the same time, the electronic report is only a copy of the paper report, and the relevant content and effectiveness is subject to the paper report. 11.检验报告二维码具浏览和下载完整报告功能,是应委托方要求所设,该二维码及其复制图能使任何人 扫描获取完整的检验报告电子版,本报告持有人如需限制他人经该二维码获取检验报告内容,应自行遮 盖或消除检验报告及其复制件所附二维码,我院对委托方选择检验报告二维码功能所致的信息泄露概不 负责(适用于附二维码报告)。 The QR code has the function of browsing and downloading complete report. Setting this function or not is chosen by the customer. The QR code and its copy enable anyone to scan and obtain the complete electronic version of the test report. Thus, if the owner of this report needs to restrict others from obtaining the content of the test report through the QR code, he shall cover or remove the QR code attached to the test report and its copies by himself. SMQ assumes no responsibility for the information leakage caused by the customer's selection of the QR code function of the test report(This clause applies to reports with QR code attached). 投诉及报告/证书真伪查询电话 Complaint hotline: 400-900-8999 按 5 Email:[email protected] Report No.: WT248001431 Page 2/ 11 TEST REPORT DECLARATION Applicant : FRONTIER SMART TECHNOLOGIES Address : Harston Mill, Harston, Cambridge, CB22 7GG, UNITED KINGDOM Manufacturer : FRONTIER SMART TECHNOLOGIES Address : Harston Mill, Harston, Cambridge, CB22 7GG, UNITED KINGDOM EUT Description : Auria Brand : -- MODEL No : FS2345 Test Standards: IEEE Std 149-1979 The EUT described above is tested by Shenzhen Academy of Metrology and Quality Inspection EMC Laboratory to determine the maximum emissions from the EUT and ensure the EUT to be compliance with the immunity requirements of the EUT. Shenzhen Academy of Metrology and Quality Inspection EMC Laboratory is assumed full responsibility for the accuracy of the test results. The test report is valid for above tested sample only and shall not be reproduced in part without written approval of the laboratory. Project Engineer: Date: Jul. 19, 2024 (Zhou Li 周立) Checked by: Date: Jul. 19, 2024 (Wan Xiao Jing 万晓婧) Approved by: Date: Jul. 19, 2024 (Lin Bin 林斌) Report No.: WT248001431 Page 3/ 11 TABLE OF CONTENTS TEST REPORT DECLARATION ........................................................................................................ 2 1. TEST RESULTS SUMMARY .................................................…

Text truncated - open the document above for the full version.

Test Report

SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD 102A,102B,Building2,ShanghenglangNewIndustrialZone,ShanghenglangCommunity, DalangStreet,LonghuaDistrict,Shenzhen,Guangdong,People’sRepublicofChina,518000 Telephone:+86-755-26648640 Fax:+86-755-26648637 Website:www.cqa-cert.com ReportTemplateVersion:V06 ReportTemplateRevisionDate:2026-01-30 TestReport Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthisreportreferonlyto thesample(s)tested.WithoutwrittenapprovalofCQA,thisreportcan’tbereproducedexceptinfull. ReportNo.:CQASZ20260500916E-01 Applicant:UltimeaTechnology(Shenzhen)Limited AddressofApplicant:20thFloor,Building4,TiananCloudPark,BantianSt.,LonggangDistrict, Shenzhen,China EquipmentUnderTest(EUT): Product: Soundbar ModelNo.: UC001 TestModelNo.:UC001 BrandName: ULTIMEA FCCID: 2A9OO-UC001S Standards:47CFRPart15,SubpartC KDB558074D0115.247MeasGuidancev05r02 ANSIC63.10:2020 DateofReceipt:2026-05-07 DateofTest: 2026-05-07to2026-06-04 DateofIssue:2026-06-18 TestResult:PASS* *Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove. TestedBy: (LewisZhou) ReviewedBy: (TimoLei) ApprovedBy: (JackAi) SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260500916E-01 Page:2of32 1Version RevisionHistoryOfReport ReportNo.Version Description IssueDate CQASZ20260500916E-01Rev.01 Initialreport 2026-06-18 Note: ExceptforConductedPeakOutputPower,ACPowerLineConductedEmission,RadiatedSpurious Emissions,andRestrictedBandsaroundFundamentalFrequency,allothertestdataareleveraged fromtheoriginalmodule(FCCID:YYX-FS2345). SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260500916E-01 Page:3of32 ComparisonSummaryTable Parameter/ Feature OriginalModuleEUT Remarks/ Impact ModelName[YYX-FS2345][2A9OO-UC001S]FCCID Antenna Specification 2.4G: ANT1:PIFAantenna/2.21dBi ANT2:PIFAantenna/1.86dBi 5G: ANT1:PIFAantenna/ 2.11dBifor5150-5250MHZ 3.42dBifor5250-5350MHZ 4.54dBifor5470-5725MHZ 3.05dBifor5725-5850MHZ ANT2:PIFAantenna/ 2.75dBifor5150-5250MHZ 3.02dBifor5250-5350MHZ 2.04dBifor5470-5725MHZ 0.22dBifor5725-5850MHZ 2.4G: ANT1:FPCantenna/2.87dBi ANT2:PIFAantenna/1.86dBi 5G: ANT1:FPCantenna/ 3.23dBifor5725-5850MHZ ANT2:PIFAantenna/ 0.22dBifor5725-5850MHZ Antenna changed Frequency Range/ Operation Mode BLE: 1Mbps,2Mbps: 2402MHz~2480MHz BT: 1Mbps/2Mbps/3Mbps 2402MHz~2480MHz 2.4GHz:Wi-Fi: 802.11b/g/n(HT20)/ax(HE20): 2412MHz~2462MHz 5GWIFI: 802.11a/n/ac/ax(20M): 5180MHz~5240MHz; 5260MHz~5320MHz; 5500MHz~5720MHz; 5745MHz~5825MHz BLE: 1Mbps,2Mbps: 2402MHz~2480MHz BT: 1Mbps/2Mbps/3Mbps 2402MHz~2480MHz 2.4GHz:Wi-Fi: 802.11b/g/n(HT20)/ax(HE20): 2412MHz~2462MHz 5GWIFI: IEEE802.11a/n/ac/ax(20M): 5745MHz~5825MHz Frequency band SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260500916E-01 Page:4of32 2TestSummary TestItemTestRequirementTestmethodResult AntennaRequirement47CFRPart15.203/PASS ACPowerLineConducted Emission 47CFRPart15,SubpartCSection 15.207 ANSI C63.10-2020+Cor. 1-2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS ConductedPeakOutput Power 47CFRPart15.247 ANSI C63.10-2020+Cor. 1-2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS 20dBOccupiedBandwidth47CFRPart15.247 ANSI C63.10-2020+Cor. 1-2023+C63.10a-2024+ ErratatoC63.10a-2024 N/A CarrierFrequencies Separation 47CFRPart15.247 ANSI C63.10-2020+Cor. 1-2023+C63.10a-2024+ ErratatoC63.10a-2024 N/A HoppingChannelNumber47CFRPart15.247 ANSI C63.10-2020+Cor. 1-2023+C63.10a-2024+ ErratatoC63.10a-2024 N/A DwellTime47CFRPart15.247 ANSI C63.10-2020+Cor. 1-2023+C63.10a-2024+ ErratatoC63.10a-2024 N/A PseudorandomFrequency HoppingSequence 47CFRPart15.247 ANSI C63.10-2020+Cor. 1-2023+C63.10a-2024+ ErratatoC63.10a-2024 N/A Band-edgeforRF ConductedEmissions 47CFRPart15.247 ANSI C63.10-2020+Cor. 1-2023+C63.10a-2024+ ErratatoC63.10a-2024 N/A RFConductedSpurious Emissions 47CFRPart15.247 ANSI C63.10-2020+Cor. 1-2023+C63.10a-2024+ ErratatoC63.10a-2024 N/A RadiatedSpurious emissions 47CFRPart15.209 ANSI C63.10-2020+Cor. 1-2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS Restrictedbandsaround fundamentalfrequency (RadiatedEmission) 47CFRPart15.205/15.209 ANSI C63.10-2020+Cor. 1-2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260500916E-01 Page:5of32 Remark: Thetestedsample(s)andthesampleinformationareprovidedbytheclient. Tx:InthiswholereportTx(ortx)meansTransmitter. Rx:InthiswholereportRx(orrx)meansReceiver. RF:InthiswholereportRFmeansRadiatedFrequency. CH:InthiswholereportCHmeanschannel. Volt:InthiswholereportVoltmeansVoltage. Temp:InthiswholereportTempmeansTemperature. Humid:InthiswholereportHumidmeanshumidity. Press:InthiswholereportPressmeansPressure. N/A:Inthiswholereportnotapplication SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260500916E-01 Page:6of32 3Contents Page 1VERSION..........................................................................................................................................................................2 2TESTSUMMARY............................................................................................................................................................4 3CONTENTS......................................................................................................................................................................6 4GENERALINFORMATION...........................................................................................................................................7 4.1CLIENTINFORMATION.................................................................................................................................................7 4.2GENERALDESCRIPTIONOFEUT.................................................................................................................................7 4.3ADDITIONALINSTRUCTIONS........................................................................................................................................9 4.4TESTENVIRONMENT.....................................................…

Text truncated - open the document above for the full version.

Test Report

1 ShenZhen City FeiMin Technology CO.,LTD. SPECIFICATION FOR APPROVED CUSTOMER: Huizhou Vocal Intelligence Technology Co., Ltd. PRODUCTS: FPC antenna PART NO: Spec.: FM-S2835-UC001-FPC Data: 2026.6.18 REMARK:Please send us one(or copy)of this approval with stamp after accepting,other copies filed by the customer. ADD: Room 801, 8th Floor, Keyunda E-commerce Base, No. 4 Shenghui Road, Guxing Community, Xixiang Subdistrict, Baoan District, Shenzhen. Tel: 0755-23035723 Fax: 0755-23036702 E-mail: [email protected] HTTP:www.fmant.cn CUSTOMER ACCEPTED BY CHECKED BY APPROVED BY SUPPLIER PREPARED BY CHECKED BY APPROVED BY ANTENNA SPECIFICATION Shenzhen Feimin Technology Co.,Ltd 2 catalog 1. Project Information ................................................................................................... 4 1.1. Appearance and Dimensions ........................................................................... 4 2. Electrical Characteristics ........................................................................................... 5 2.1. Test Environment Conditions .......................................................................... 5 2.2.Measurement method .......................................................................................... 5 2.2.2.Antenna VSWR ............................................................................................. 5 2.2.3.Antenna Return loss ............................................................................. 6 2.3.Antenna passive test data ..................................................................... 6 2.3.1.Test system ................................................................................................. 6 2.3.2.Antenna efficiency and gain........................................................... 7 2.3.3.Antenna Radiation Pattern ..................................................................... 8 3.Notes ............................................................................................................................. 9 4.Product packaging specification .................................................................................. 9 ANTENNA SPECIFICATION Shenzhen Feimin Technology Co.,Ltd 3 Revision history version date condition A1 2026-4-20 First edition A2 2026-6-18 Update product drawings. Changes: First change: Before the change: (If necessary, please add corresponding pictures, and the details of the change should be clearly described here) After the change: (If necessary, please add corresponding pictures, and the details of the change should be clearly described here) ANTENNA SPECIFICATION Shenzhen Feimin Technology Co.,Ltd 4 1. Project Information 1.1. Appearance and Dimensions ANTENNA SPECIFICATION Shenzhen Feimin Technology Co.,Ltd 5 2. Electrical Characteristics 2.1. Test Environment Conditions Temperature Ordinary Temperature (5 to 35°C) Humidity Ordinary Humidity (25 to 85% RH) 2.2.Measurement method 2.2.2.Antenna VSWR ANTENNA SPECIFICATION Shenzhen Feimin Technology Co.,Ltd 6 2.2.3.Antenna Return loss 2.3.Antenna passive test data 2.3.1.Test system Shenzhen Feimin Technology Co., Ltd. (24-probe OTA microwave darkroom) ANTENNA SPECIFICATION Shenzhen Feimin Technology Co.,Ltd 7 2.3.2.Antenna efficiency and gain Freq(MHz) Efficiency (%) Gain(dBi) 2400 56.00 2.68 2410 57.55 2.72 2420 57.75 2.61 2430 58.84 2.65 2440 59.59 2.76 2450 61.86 2.85 2460 61.77 2.87 2470 60.21 2.73 2480 59.56 2.76 2490 59.40 2.65 2500 57.15 2.57 5150 63.09 2.64 5200 62.87 2.93 5250 58.57 2.53 5300 59.29 2.76 5350 61.53 2.86 5400 62.64 2.98 5450 61.53 3.04 5500 62.98 2.97 5550 63.23 2.90 5600 63.89 3.09 5650 64.17 2.85 5700 65.17 3.05 5750 63.43 2.93 5800 66.24 3.18 5850 66.00 3.23 ANTENNA SPECIFICATION Shenzhen Feimin Technology Co.,Ltd 8 2.3.3.Antenna Radiation Pattern ANTENNA SPECIFICATION Shenzhen Feimin Technology Co.,Ltd 9 3.Notes ①. When installing, be careful not to be too close to the metal parts to avoid affecting the antenna performance. ②.This antenna is only suitable for this type of machine. The position of the antenna cannot be changed at will, and it is not our business' responsibility if it is used on other machines that results in poor results. ③. The data used in this acknowledgment (e.g., antenna efficiency, gain, etc.) are data obtained from laboratory tests of the acknowledgement project / antenna in Shenzhen Fei Min Technology Co., Ltd. 4.Product packaging specification Product name: FPC antenna 1、Labeling requirements The inner label is 7CM long and 4CM wide The outer label is 7CM long, about 5CM 2、Packing process Job description: 1. The product __PCS is packed in PE open pockets, and the inner label is affixed to each pouch; Put the __ small bag into the big PE sealing tape bag, except the tail number and spare parts. 2. Each box contains __ large bags of products, and the boxes are sealed with adhesive tape in the shape of "I"。 3. Paste the outer label on the upper right corner of the box, and there must be no missing or wrong filling. 3、Precautions When packing the box, please pay attention to lay the antenna flat and avoid serious shaking after sealing. If the whole box is not filled, it needs to be filled with foam to avoid transportation Circumstances that caused product defects in the process。 client's name supplier Shenzhen Feimin Technology Co., Ltd. Order number ************* Material coding ************* Specification model ****** product name ******* quantity *****PCS QC: spare parts ***PCS Notes supplier Shenzhen Feimin Technology Co., Ltd. product name ************* Material coding ************* Specifications ********** quantity ***PCS

Test Report

Report No.: WT248001431 Page 1/11 ANTENNA TEST REPORT For Auria Model Number: FS2345 Report Number : WT248001431 Test Laboratory : Shenzhen Academy of Metrology and Quality Inspection Site Location : No.4, Tongfa Road, Xili Street, Nanshan District, Shenzhen, Guangdong, China Tel : 0086-755-86928965 Fax : 0086-755-86009898-31396 Web : www.smq.com.cn Report No.: WT248001431 Page 2/11 TEST REPORT DECLARATION Applicant : FRONTIER SMART TECHNOLOGIES Address : Harston Mill, Harston, Cambridge, CB22 7GG, UNITED KINGDOM Manufacturer : FRONTIER SMART TECHNOLOGIES Address : Harston Mill, Harston, Cambridge, CB22 7GG, UNITED KINGDOM EUT Description : Auria Brand : -- MODEL No : FS2345 Test Standards: IEEE Std 149-1979 The EUT described above is tested by Shenzhen Academy of Metrology and Quality Inspection EMC Laboratory to determine the maximum emissions from the EUT and ensure the EUT to be compliance with the immunity requirements of the EUT. Shenzhen Academy of Metrology and Quality Inspection EMC Laboratory is assumed full responsibility for the accuracy of the test results. The test report is valid for above tested sample only and shall not be reproduced in part without written approval of the laboratory. Project Engineer: Date: Jul. 19, 2024 (Zhou Li 周立) Checked by: Date: Jul. 19, 2024 (Wan Xiao Jing 万晓婧) Approved by: Date: Jul. 19, 2024 (Lin Bin 林斌) Report No.: WT248001431 Page 3/11 TABLE OF CONTENTS TEST REPORT DECLARATION ........................................................................................................ 2 1. TEST RESULTS SUMMARY ................................................................................................... 4 2. GENERAL INFORMATION ...................................................................................................... 5 2.1. Report information .......................................................................................................... 5 2.2. Laboratory Accreditation and Relationship to Customer ......................................... 5 3. GENERAL INFORMATION ...................................................................................................... 6 4. TEST PROCEDURE .................................................................................................................. 6 5. SUMMATION TEST REPORT ................................................................................................. 7 5.1. Equipment Under Test DescRiption ............................................................................ 7 5.2. Test Setup ....................................................................................................................... 7 6. TEST EQUIPMENT USED ....................................................................................................... 8 7. TEST DATA ................................................................................................................................ 8 7.1. TEST RESULTS ............................................................................................................. 8 8. TEST PHOTO ........................................................................................................................... 11 Report No.: WT248001431 Page 4/11 1. TEST RESULTS SUMMARY Table 1 Test Results Summary Frequency Band (MHz) Gain (max) Efficiency (max) 2400~2483.5 1.86 43.92 5150~5350 3.02 53.43 5470~5725 2.04 48.97 5725~5875 0.22 38.79 Remark: “N/A” means “Not applicable.” Report No.: WT248001431 Page 5/11 2. GENERAL INFORMATION 2.1. Report information This report is not a certificate of quality; it only applies to the sample of the specific product/equipment given at the time of its testing. The results are not used to indicate or imply that they are application to the similar items. In addition, such results must not be used to indicate or imply that SMQ approves recommends or endorses the manufacture, supplier, or use of such product/equipment, or that SMQ in any way guarantees the later performance of the product/equipment. The sample/s mentioned in this report is/are supplied by Applicant, SMQ therefore assumes no responsibility for the accuracy of information on the brand name, model number, origin of manufacture or any information supplied. Additional copies of the report are available to the Applicant at an additional fee. No third part can obtain a copy of this report through SMQ, unless the applicant has authorized SMQ in writing to do so. The lab will not be liable for any loss or damage resulting for false, inaccurate, inappropriate, or incomplete product information provided by the applicant/manufacturer. 2.2. Laboratory Accreditation and Relationship to Customer The testing report were performed by the Shenzhen Academy of Metrology and quality Inspection EMC Laboratory (Guangdong EMC compliance testing center), in their facilities located at NETC Building, No.4 Tongfa Rd., Xili, Nanshan, Shenzhen, China. At the time of testing, Laboratory is accredited by the following organizations: China National Accreditation Service for Conformity Assessment (CNAS) accredits the Laboratory for conformance to FCC standards, EMC international standards and EN standards. The Registration Number is CNAS L0579. The Laboratory is Accredited Testing Laboratory of FCC with Designation number CN1165 and Site registration number 582918. The Laboratory is registered to perform emission tests with Innovation, Science and Economic Development (ISED), and the registration number is 11177A. The Laboratory is registered to perform emission tests with VCCI, and the registration number are C-20048, G20076, R-20077, R-20078 and T-20047. The Laboratory is Accredited Testing Laboratory of American Association for Laboratory Accreditation (A2LA) and certificate number is 3292.01. Report No.: WT248001431 Page 6/11 3. GENERAL INFORMATION Over the Air Measurements (Active) are performed in a Satimo SG-24. The SG-24 has 23 probe antennas mounted with equal sp…

Text truncated - open the document above for the full version.

RF Exposure Info

ShenzhenHuaxiaTestingTechnologyCo.,Ltd. SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD102A,102B,Building2,Shanghenglang NewIndustrialZone,ShanghenglangCommunity,DalangStreet,LonghuaDistrict,Shenzhen, Guangdong,People’sRepublicofChina,518000 Telephone:+86-755-26648640 Fax:+86-755-26648637 Website:www.cqa-cert.com ReportTemplateVersion:V05 ReportTemplateRevisionDate:2021-11-03 RFExposureEvaluationReport Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthisreportreferonlyto thesample(s)tested.WithoutwrittenapprovalofCQA,thisreportcan’tbereproducedexceptinfull. ReportNo.:CQASZ20260500916E-06 Applicant:UltimeaTechnology(Shenzhen)Limited AddressofApplicant:20thFloor,…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Yoyo Yu
[email protected]Fax: 0755-23762801

Technical Contact

Ultimea Inc.Monica Lin
[email protected]

801 S Dupont Ave,STE G · Ontario, California, 91761 · United States

Test Firm

Shenzhen Huaxia Testing Technology Co., LtdJack Ai
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz4.30 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons.

Other Applications from Ultimea Technology (Shenzhen) Limited

Surround Speaker - FCC ID 2A9OO-U4320D - Ultimea Technology (Shenzhen) Limited
2A9OO-U4320D

Surround Speaker

Sep 01, 2026

Equipment Class

DTS - Digital Transmission System
Active Subwoofer - FCC ID 2A9OO-U4320B - Ultimea Technology (Shenzhen) Limited
2A9OO-U4320B

Active Subwoofer

Sep 01, 2026

Equipment Class

DTS - Digital Transmission System
Active Subwoofer - FCC ID 2A9OO-U382AB - Ultimea Technology (Shenzhen) Limited
2A9OO-U382AB

Active Subwoofer

Aug 31, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Soundbar - FCC ID 2A9OO-U382AS - Ultimea Technology (Shenzhen) Limited
2A9OO-U382AS

Soundbar

Aug 31, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Surround Speaker - FCC ID 2A9OO-U382AD - Ultimea Technology (Shenzhen) Limited
2A9OO-U382AD

Surround Speaker

Aug 31, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter