Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Max Cooking Robot —— User Manual Copyright and License Any form of reproduction, adaptation, or translation without prior written permission shall be strictly prohibited unless otherwise stipulated by copyright law. The information contained herein shall be subject to change without prior notice. Botinkit products and services shall only be guaranteed by the written warranty statement provided along. Nothing described herein should be regarded as an additional warranty. Botinkit will not assume any responsibility for any technical or editorial errors or omissions of the contents described herein. Nov. 15th, 2022 Second Edition Trademark Statement Java™ is a trademark of SunMicrosystems, Inc. in the US. Android is a registered trademark of Google in the US. Reading Guide Purpose This document serves mainly as a guide to the smart cooking robot — BT MAX01 provided by Shenzhen BOTINKIT Technology Co., Ltd. for product users to basically understand the function, performance, and characteristics of the product, and how to use and maintain the product. Target Readers This manual covers the installation, operation, and maintenance of smart cooking robots, providing users with a guide for the installation and operation personnel and users. The following rules apply to this document: 1. Used for all menus; 2. Used by all referenced documents. [Notes] The following situations are not considered for this product - Used by unattended children or the disabled —— Played with by children [Warning] To ensure safe use and avoid injury and property loss to you and others, please observe the following safety precautions. Failure to observe safety warnings and wrong use may lead to accidents. Practices used in this manual Hint: useful hints or shortcuts. Comment: important information to explain a concept or complete a task. Compulsory: matters for users to follow to ensure the normal use of the product. Prohibition: the operation that is prohibited. Warning: precautions. Note: warnings that remind users of specific steps to be followed to avoid personal injury, catastrophic data loss, or major damage to the product. This product must be effectively grounded. The air inlet and outlet of the product must be unobstructed. Do not cover or block the air inlet and outlet. This product is equipped with a rotating pot. Do not disassemble it and replace it with other pots without training. The solid and liquid seasonings should be placed in the order in which the product was manufactured. Please be sure to add corresponding seasoning types according to their labels in solid and liquid seasoning containers. Untrained personnel is not allowed to operate this product. Non-professionals are not allowed to disassemble the electric box and start the stop switch. Non-professionals are not allowed to operate the product with the left and right side panels of the product disassembled. Do not flush the machine directly with a water gun. Do not touch the moving parts such as the rotating pot with any part of your body to avoid accidental injury. Do not dry burning of the pot to avoid burning out the coating under continuous high temperatures. Do not pour the starch water directly into the starch water box under the condition that the starch water is not fully and evenly mixed and still has precipitation. Do not use the starch water box without stirring to avoid starch precipitation in the box. This product is for indoor use only. If you do not use the product for a long time to put in solid and liquid seasonings, please empty and clean the containers of solid and liquid seasonings, and then clean the pipeline. If the solid and liquid seasonings have not been used up for a long time, please check whether the seasonings inside the container are deteriorated. If there is deterioration, it must be cleaned before it can be used again. Each machine is equipped with a water gun, which is used to flush the tank of the pot and the sink of the workbench. Do not use it to flush the pot and other parts of the machine. When the product fails, abnormal information will appear on the display. Please refer to the maintenance manual or contact the after- sales staff for online or offline troubleshooting. When cooking with the robot, please keep a proper distance to avoid scalding caused by the splashing of hot oil due to impurities. Pay attention to all kinds of seasonings added, which must not be mixed with other impurities. Note that the added seasonings such as salt, sugar, chicken powder, pepper, and MSG must be dry. Do not add moist solid seasonings. The solid seasonings of salt, sugar, chicken powder, pepper, and MSG applicable to this product must meet the specification requirements, otherwise, the seasoning adding accuracy may be affected or the outlet may be jammed. Note that after taking out the liquid seasonings, check whether the magnetic suction connector is sucked in place when putting it back. Before cooking, check that the glass door on the seasoning module is closed. Note that only when the machine is powered on, the starch water that is mixed evenly and not precipitated is placed inside the machine in time can it be stirred effectively all the time. Note that when the machine is turned off and turned on again, it is necessary to open and check the starch water and manually assist in stirring to make it mix evenly. Pay attention to the product maintenance requirements, and regularly clean all seasoning containers and liquid seasoning tubes. Clean the residual seasonings on the inner wall of the solid seasoning adding nozzle in time every day after the cooking task is completed. The installation and maintenance of this product involve disassembly and assembly, which should be operated by our after-sales personnel or personnel trained by our company. If the power cord is damaged, it must be replaced by professionals from the manufacturer, its maintenance department, and similar departments to avoid danger. This manual is not ap…
Text truncated - open the document above for the full version.
Rev 1/26/2023 Shenzhen BOTINKIT Co., Ltd. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 02‐06‐2023 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2A9P9MAX01 [Shenzhen BOTINKIT Co., Ltd.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, (Applicant signature) (Applicant printed name) Qiang Fu
Rev 1/26/2023 Shenzhen BOTINKIT Co., Ltd. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 02‐06‐2023 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: 2A9P9MAX01 [Shenzhen BOTINKIT Co., Ltd.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) Qiang Fu
Shenzhen BOTINKIT Co., Ltd. 26A. Zimao Center, No.111 Taizi Road, Nanshan Shenzhen, China 518067 Date: 02/17/2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2A9P9MAX01 US Agent – Attestation Statement / Part 2.911(d)(7) Shenzhen BOTINKIT Co., Ltd. certifies, that as of 02/17/2023, we have designated FCC US Agent, LLC to accept service of process on our behalf for FCC ID: 2A9P9MAX01. Shenzhen BOTINKIT Co., Ltd., accepts to maintain an agent of service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission- related administrative or judicial proceeding involving the equipment, whichever is later. FCC US Agent, LLC, accepts as of the date of the filing of this application, the obligation of being the designated agent for the purpose of accepting service of process on behalf of Shenzhen BOTINKIT Co., Ltd. for FCC ID: 2A9P9MAX01. Designated Agent Information: Company Name: FCC US Agent, LLC FRN: 0033402884 Address: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA Contact Person: Tim Payne Phone: 708-571-3148 Email: [email protected] Sincerely, Company: Shenzhen BOTINKIT Co., Ltd. Designated Agent: FCC US Agent, LLC Company Representative: Qiang Fu Designated Agent Representative: Tim Payne Signature: Signature:
Shenzhen BOTINKIT Co., Ltd. Date: Feb. 02, 2023 Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: 2A9P9MAX01 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type Sch ematics Block Diagram Operational Description U-NII Device Security Statement File Name Schematics.pdf Block Diagram.pdf Operational Description.pdf U-NII Device Security Statement V1.pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Shenzhen BOTINKIT Co., Ltd. Signature Qiang Fu / Product Director Typed name and Title
Shenzhen BOTINKIT Co., Ltd. FCC ID: 2A9P9MAX01 POWER OF ATTORNEY Date: Jan. 03, 2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 To Whom It May Concern: We, the undersigned, hereby authorize Waltek Testing Group Co., Ltd. (Philo Zhong) on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by Waltek Testing Group Co., Ltd. (Philo Zhong) on our behalf shall have the same effect as acts of our own. This authorization expires on Jan. 02, 2024. This is to advise that we are in full compliance with the Anti-Drug Abuse Act. We, Shenzhen BOTINKIT Co., Ltd.are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Sincerely, Shenzhen BOTINKIT Co., Ltd. Signature Qiang Fu / Product Director Typed name and Title
Appendix- MAX01-Photos Page 3 of 12 2. Photographs –Constructional Details 2.1. EUT – External View Model MAX01 FCC ID: 2A9P9MAX01 Appendix- MAX01-Photos Page 4 of 12 Appendix- MAX01-Photos Page 5 of 12 Appendix- MAX01-Photos Page 6 of 12
Appendix- MAX01-Photos Page 7 of 12 2.2. EUT – Internal View Model MAX01 FCC ID: 2A9P9MAX01 Appendix- MAX01-Photos Page 8 of 12 Appendix- MAX01-Photos Page 9 of 12 Appendix- MAX01-Photos Page 10 of 12 Appendix- MAX01-Photos Page 11 of 12 Appendix- MAX01-Photos Page 12 of 12
Waltek Testing Group Co., Ltd. http://www.waltek.com.cn Page 1 of 8 TEST REPORT Reference No. .................... : WTX22D11238793W004 FCC ID ................................ : 2A9P9MAX01 Applicant ............................ : Shenzhen BOTINKIT Co., Ltd. Address .............................. : 26A. Zimao Center, No.111 Taizi Road, Nanshan, Shenzhen, China Manufacturer .................... : Shenzhen BOTINKIT Co., Ltd. Address .............................. : 26A. Zimao Center, No.111 Taizi Road, Nanshan, Shenzhen, China Product ............................... : Smart cooking machine Model(s). ............................ : MAX01 Brand Name. ...................... : BOTINKIT Standards........................... : FCC 47CFR Part 2 Subpart J Section 2.1091 Date of Receipt sample .... : 2022-12-08 Date of Test ....................... : 2022-12-08 to 2023-02-03 Date of Issue ...................... : 2023-02-03 Test Result ......................... : Pass Remarks: The re sults shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Prepared By: Waltek Testing Group Co., Ltd. Address: No. 77, Houjie Section, Guantai Road, Houjie Town, Dongguan City, Guangdong, China Tel: +86-769-2267 6998 Fax: +86-769-2267 6828 Compiled by: Approved by: James Cheng/ Project Engineer Deval Qin / Designated Reviewer Reference No.: WTX22D11238793W004 Page 2 of 8 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 2. Contents Page 1 COVER PAGE ........................................................................................................................................... 1 2. CONTENTS ............................................................................................................................................... 2 3. REVISION HISTORY ................................................................................................................................. 3 4. GENERAL INFORMATION ....................................................................................................................... 4 4.1. GENERAL DESCRIPTION OF E.U.T.................................................................................................... 4 4.2. DETAILS OF E.U.T. ......................................................................................................................... 4 4.3. TEST FACILITY ................................................................................................................................ 5 4.4. SUBCONTRACTED ........................................................................................................................... 5 4.5. ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................ 5 5. TEST SUMMARY ...................................................................................................................................... 6 6. RF EXPOSURE ......................................................................................................................................... 7 6.1. REQUIREMENTS .............................................................................................................................. 7 6.2. THE PROCEDURES / LIMIT ................................................................................................................ 7 6.3. MPE CALCULATION METHOD........................................................................................................... 8 6.4. RADIO FREQUENCY RADIATION EXPOSURE EVALUATION ................................................................... 8 Reference No.: WTX22D11238793W004 Page 3 of 8 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 3. Revision History Test Report No. Date of Receipt Sample Date of Test Date of Issue Purpose Comment Approved WTX22D11238793W004 2022-12-08 2022-12-08 to 2023-02-03 2023-02-03Original - Valid Reference No.: WTX22D11238793W004 Page 4 of 8 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 4. General Information 4.1. General Description of E.U.T. Product: Smart cooking machine Model(s): MAX01 Model difference: N/A Wi-Fi Specification: 2.4G-802.11b/g/n HT20/n HT40 5G-802.11a/ n(HT20/40)/ac(VHT20/40/80) Hardware Version: BTKJ_MAIN_V13 Software Version: FW_V1.8.0 4.2. Details of E.U.T. Operation Frequency: 802.11a/n/ac (VHT20): U-NII-1: 5150-5250MHz, U-NII-2A: 5250-5350MHz(DFS), U-NII-2C: 5470-5725MHz(DFS), U-NII-3:5725-5850MHz 802.11n/ac (VHT40): U-NII-1: 5190-5230MHz, U-NII-2A: 5270-5310MHz(DFS), U-NII-2C: 5510-5670MHz(DFS), U-NII-3: 5755-5795MHz 802.11ac (VHT80): U-NII-1: 5210MHz, U-NII-2A: 5290MHz(DFS), U-NII-2C: 5530-5610MHz(DFS), U-NII-3: 5775MHz 2.4G Wi-Fi: 802.11b/g/n HT20: 2412~2462MHz, 11CH 802.11n HT40: 2422~2452MHz, 7CH Max. RF output power: 5G Wi-Fi: U-NII-1: 17.21dBm U-NII-2A: 17.54dBm U-NII-2C: 19.47dBm U-NII-3: 17.09dBm 2.4G Wi-Fi: 19.51dBm Modulation Technology: DQPSK, DBPSK, DSSS, CCK and OFDM Antenna installation: External antenna Antenna Gain: 2.4G Wi-Fi: 2.51dBi 5G Wi-Fi: U-NII-1: 2.86dBi U-NII-2A: 3.38dBi U-NII-2C: 4.14dBi U-NII-3: 3.07dBi Ratings: AC 220V Reference No.: WTX22D11238793W004 Page 5 of 8 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 4.3. Test Facility The test facility has a test site registered with the following organizations: ISED CAB identifier: CN0013. Test Firm Registration No.: 7760A. Waltek Testing Group Co., Ltd. Has been registered and fully described in a report filed with the Industry Canada. The acceptance letter from the Industry Canada is maintained in our files. Registration number 7760A, October 15, 2016. FCC Designation No.: CN1201. Test Firm Registration No.: 523476. Waltek Testing Group Co., Ltd. EMC Laboratory has been registered and fully described in a report file…
Text truncated - open the document above for the full version.
Waltek Testing Group Co., Ltd. http://www.waltek.com.cn Page 1 of 57 TEST REPORT Referen ce No. .................... : WTX22D11238793W001 FCC ID ................................ : 2A9P9MAX01 Applicant ............................ : Shenzhen BOTINKIT Co., Ltd. Address .............................. : 26A. Zimao Center, No.111 Taizi Road, Nanshan, Shenzhen, China Manufacturer .................... : Shenzhen BOTINKIT Co., Ltd. Address .............................. : 26A. Zimao Center, No.111 Taizi Road, Nanshan, Shenzhen, China Product ............................... : Smart cooking machine Model(s). ............................ : MAX01 Brand Name ....................... : BOTINKIT Standards........................... : FCC 47CFR Part 15.247 Date of Receipt sample .... : 2022-12-08 Date of Test ....................... : 2022-12-08 to 2023-02-03 Date of Issue ...................... : 2023-02-03 Test Result ......................... : Pass Remarks: The re sults shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Prepared By: Waltek Testing Group Co., Ltd. Address: No. 77, Houjie Section, Guantai Road, Houjie Town, Dongguan City, Guangdong, China Tel: +86-769-2267 6998 Fax: +86-769-2267 6828 Compiled by: Approved by: James Cheng / Project Engineer Deval Qin / Designated Reviewer Reference No.: WTX22D11238793W001 Page 2 of 57 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 2 Contents Page 1 COVER PAGE ........................................................................................................................................... 1 2 CONTENTS ............................................................................................................................................... 2 3 REVISION HISTORY ................................................................................................................................. 4 4 GENERAL INFORMATION ....................................................................................................................... 5 4.1 GENERAL DESCRIPTION OF E.U.T. ....................................................................................................... 5 4.2 DETAILS OF E.U.T. .............................................................................................................................. 5 4.3 CHANNEL LIST ..................................................................................................................................... 5 4.4 TEST FACILITY .................................................................................................................................... 6 4.5 SUBCONTRACTED ................................................................................................................................ 6 4.6 ABNORMALITIES FROM STANDARD CONDITIONS .................................................................................... 6 4.7 TEST MODE ........................................................................................................................................ 7 5 TEST SUMMARY ...................................................................................................................................... 8 6 EQUIPMENT USED DURING TEST ......................................................................................................... 9 6.1 EQUIPMENTS LIST ............................................................................................................................... 9 6.2 DESCRIPTION OF SUPPORT UNITS ........................................................................................................ 9 6.3 MEASUREMENT UNCERTAINTY ........................................................................................................... 10 6.4 TEST EQUIPMENT CALIBRATION ......................................................................................................... 10 7 DUTY CYCLE .......................................................................................................................................... 11 8 CONDUCTED EMISSION ....................................................................................................................... 13 8.1 E.U.T. OPERATION ............................................................................................................................ 13 8.2 EUT SETUP ...................................................................................................................................... 13 8.3 MEASUREMENT DESCRIPTION ............................................................................................................ 13 8.4 CONDUCTED EMISSION TEST RESULT ................................................................................................ 13 9 RADIATED EMISSIONS ......................................................................................................................... 17 9.1 EUT OPERATION ............................................................................................................................... 17 9.2 TEST SETUP ..................................................................................................................................... 18 9.3 SPECTRUM ANALYZER SETUP ............................................................................................................ 19 9.4 TEST PROCEDURE ............................................................................................................................. 20 9.5 CORRECTED AMPLITUDE & MARGIN CALCULATION .............................................................................. 20 9.6 SUMMARY OF TEST RESULTS ...................................................................................................…
Text truncated - open the document above for the full version.
致力于为客户提供专业级天线解决方案 Complete Antenna specification of non- stop MAX project Radio Frequency: He LeiDate: 2022-11-25Contact: 15767667652 Antenna model:MAX41WIFIAntenna Manufacturer:Yusheng Communication-equipment Co.,LTD Manufacturer address:407-411, Floor 4, Building 2, Nantaiyun Chuanggu Park, Southeast of the intersection of Guangming Avenue and Dongchang Road, Guangming District, Shenzhen 致力于为客户提供专业级天线解决方案 1 Introduction to project debugging Report version outline Active antenna parameter Summary & additional notes 23 6 致力于为客户提供专业级天线解决方案 射频:曾祥好日期:2021-10-12报告版次:V0.1 Project development environment Yusheng's products cover almost all antenna applications of wireless terminal equipment, including automobile antenna, high-precision surveying and mapping antenna, UAV ground and satellite data navigation, high-precision positioning antenna, wireless transmission of medical equipment, consumer antenna (mobile phone antenna, PAD antenna, laptop antenna), base station/indoor distribution antenna, etc. Smart wearable antenna (smart watch, TWS headset), security home antenna and a variety of wireless data transmission and wireless control of smart device antenna We are moving from the Internet era to the smart era, and the country is building a digital society and smart cities. In the next 5-10 years, both the consumer electronics market and the Internet of Things market have huge development potential. The field of wireless communication is very diversified. In the future, Yu Sheng will strive to provide customers with professional product solutions with market competitiveness by relying on the customer platform advantages of the main antenna industry and its own comprehensive strength. Antenna design drawing 致力于为客户提供专业级天线解决方案 Introduction to project debugging MVA MAIN Frequency band and antenna material main antenna Band IPS WIFI 2.4G-2.5G Exteral 5.1G-5.8G performance requirement Execute according to customer requirements 致力于为客户提供专业级天线解决方案 Report version outline Report Version report time The antenna development to solve the problem V1.0 2022-11-25 Complete test report of 2.4G/5.8GWIFI 致力于为客户提供专业级天线解决方案 Antenna efficiency and gain 致力于为客户提供专业级天线解决方案 Radiation Pattern F or Antenna(2450MHz 致力于为客户提供专业级天线解决方案 Antenna passive parameters -2.4G direction chart Thete=90(Phi=270°为正前方) Phi=90° Phi=180° 致力于为客户提供专业级天线解决方案 Radiation Pattern F or Antenna(5550MHz 致力于为客户提供专业级天线解决方案 Antenna passive parameters -5G direction chart Thete=90(Phi=270°为正前方) Phi=90° Phi=180° 致力于为客户提供专业级天线解决方案 OTA Test Test 2.4WIFI-B(11M) 2.4WIFI-G(54M) Channel 1 6 11 1 6 11 TRP(dBm) 15.12 15.37 14.89 14.76 14.63 14.55 TIS(dBm) -81.24 -80.78 -81.36 -70.22 -69.43 -69.18 Test 2.4WIFI-N(MCS7) Channel 1 7 13 TRP(dBm) 11.14 11.56 11.28 TIS(dBm) -64.45 -65.27 -65.36 5GWIFI-A 149 157 165 10.24 10.17 10.64 -65.22 -64.67 -64.39 致力于为客户提供专业级天线解决方案 WIFI Conducted Test Test 2.4WIFI-B(11M) 2.4WIFI-G(54M) Channel 1 6 11 1 6 11 TRP(dBm) 17.4 17.2 17.1 14.5 14.9 15.2 TIS(dBm) -86 -86 -86 -73 -73 -73 Test 2.4WIFI-N(MCS7) Channel 1 7 13 TRP(dBm) 13.5 13.2 13.4 TIS(dBm) -70 -71 -70 5GWIFI-A 149 157 165 12.4 12.8 13.1 -68 -68 -69 Address : 4 / F, Building 2, Taiyun Chuanggu, South Guangming Avenue, Guangming New District, Shenzhen, ChinaTel : 0755-23984257 Fax : 0755-86090455
Appendix- MAX01-Photos Page 1 of 12 1. Test Setup photos Model MAX01 FCC ID: 2A9P9MAX01 1.1 Photograph – Conducted Emission Test Setup For Conducted Emission Test Site 1# 1.2 Photograph – Radiated Emissions For 9kHz-30MHz Test Site 2# Appendix- MAX01-Photos Page 2 of 12 For 30MHz-1000MHz Test Site 2# For Above 1GHz Test Site 1#
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 89.30 mW |