2A9U2-VF-TL802BLED LAMP

CF GROUP SZKMS CO., LTD.
LED LAMP - FCC ID 2A9U2-VF-TL802B - CF GROUP SZKMS CO., LTD.
Click to zoom

Application Details

Equipment Class
8CC - Part 18 Consumer Device
Date of Grant
Dec 28, 2022
Application Purpose
Original Equipment
Date of Application
Dec 28, 2022
Equipment Note
LED LAMP
Frequency Range
0.11200000 - 0.20500000
Company
CF GROUP SZKMS CO., LTD.
Country
China

Documents & Files

Select a file to view

Users Manual

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

Co m Ad d Dist Pr o Mo d Pr o We act We an d issu our Sig Na m Title Com mpany: CF dress: Room rict, Shenzhe oduct Name del Numbe oduct Desc authorize M on our beha declare tha d certificatio ues concern behalf shal nature: me: e: mpany: GROUP SZ m 101, Buildi en, Guangdo e: LED LAMP er(s): VF-TL8 ription: LED MiCOM Lab alf on all ma at MiCOM L n of equipm ning the app ll have the s Xun Dong Safety Cer CF GROUP CF GR Agen KMS CO., LT ing 12, Renm ong Province P 802B D LAMP bs Inc., 575 atters conce Labs Inc. is ment to the r proval applic same effect rtification En P SZKMS CO ROUP SZK nt Auth TD. min Road 22 e, China Boulder Co erning the c allowed to f regulatory a cation. Any t as acts of ngineer O., LTD. KMS CO., L horizat 1st, Fumin C ourt, Pleasa certification forward all i agencies as and all acts our own. LTD. tion Community, F anton, Califo of above na information s required a s carried ou Date: Fucheng stre ornia 94566 amed equip related to t nd to discu ut by MiCOM Dec. 28, 20 eet, Long hua 6, USA, to pment. the approva ss any M Labs on 022 a al

Cover Letter(s)

Office o Federa 7435 O Columb USA Subjec t FCC ID To Wh o Pursua are req u docume These d propriet might b In addi t in Title busine s authoriz For 4 O For 1 It is ou r corresp docume authoriz Sincer e Signatu Name: X Title: Sa of Engineeri l Communic Oakland Mills bia, MD 210 t; Request f D: 2A9U2-VF om It May C nt to the pro uesting the ents from pu documents tary informa be harmful to Schemat Block Di Parts Lis Operatio Tune-up tional to abo 47 CFR §2 ss sensitive zed devices External Test Set Internal P User Ma 45 days, pu OR 180 days pu r understand pondence du ents and thi zation is iss ely, ure: Xun Dong afety Certific CF ing Techno cations Com s Road 046 for Confiden F-TL802B Concern, ovisions of t Commissio ublic disclos contain det ation in ope o our comp tic Diagram agram st onal Descrip Procedure ove mention .803 and th informatio n s, we reque Photos tup Photos Photos anual rsuant to P u ursuantto KD ding that all uring the ce s informatio sued. cation Engi F GROU logy mmission ntiality the Commis on to withho sure indefin tailed syste ration of th e any and wo m ption ned docume e importatio n remains c st Short Te ublic Notice DB 726920 l measurem ertification re on will be av neer P SZKM ssion’s rule old the follow nitely. m and equi e equipmen ould give co ents, in orde on rules in T confidential rm Confide e DA 04-170 0 D01. ment test rep eview proce vailable for MS CO., s Title 47 S wing attach pment desc nt. The publ ompetitors a er to comply Title 47 CFR until the act ntiality of th 05. ports, FCC ess cannot public revi e LTD. Sections §0. hment(s) as criptions an ic disclosu r an unfair ad y with the m R §2.1204, tual market he following ID label for be granted ew once the Date: Dec. 457 and §0 confidentia d are consi re of these d vantage in marketing re while ensu ting of newly attachmen mat and as confide n e grant of eq 28, 2022 0.459, we al dered as documents the market . egulations ring that y t(s); ntial quipment .

External Photos

Annex A External Photos Report No.:HK2212155698-1E/2E Page 1 of 5 Report No.:HK2212155698-1E/2E Page 2 of 5 Report No.:HK2212155698-1E/2E Page 3 of 5 Report No.:HK2212155698-1E/2E Page 4 of 5 Report No.:HK2212155698-1E/2E Page 4 of 5

ID Label/Location Info

FCC ID LABEL: Ca. 20mm x 20mm Label Location FCC ID: 2A9U2-VF-TL802B

Internal Photos

Annex B Internal Photos Report No.:HK2212155698-1E/2E Page 1 of 6 Antenna Report No.:HK2212155698-1E/2E Page 2 of 6 Report No.:HK2212155698-1E/2E Page 3 of 6 Report No.:HK2212155698-1E/2E Page 4 of 6 Report No.:HK2212155698-1E/2E Page 5 of 6 Report No.:HK2212155698-1E/2E Page 6 of 6

Test Report

Page 1 of 20 Report No.: HK2212155698-1E FCC TEST REPORT Test report On Behalf of CF GROUP SZKMS CO., LTD. For LED LAMP Model No.: VF-TL802B FCC ID: 2A9U2-VF-TL802B Prepared For : CF GROUP SZKMS CO., LTD. Room 101, Building 12, Renmin Road 221st, Fumin Community, Fucheng street, Long hua District, Shenzhen, Guangdong Province, China Prepared By : Shenzhen HUAK Testing Technology Co., Ltd. 1-2/F., Building B2, Junfeng Zhongcheng Zhizao Innovation Park, Heping, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Date of Test: Dec. 15, 2022 ~ Dec. 23, 2022 Date of Report: Dec. 23, 2022 Report Number: HK2212155698-1E Page 2 of 20 Report No.: HK2212155698-1E TEST RESULT CERTIFICATION Applicant’s name ................. : CF GROUP SZKMS CO., LTD. Address .................................. : Room 101, Building 12, Renmin Road 221st, Fumin Community, Fucheng street, Long hua District, Shenzhen, Guangdong Province, China Manufacture's Name ............ : CF GROUP SZKMS CO., LTD. Address .................................. : Room 101, Building 12, Renmin Road 221st, Fumin Community, Fucheng street, Long hua District, Shenzhen, Guangdong Province, China Product description Trade Mark: VAVOFO Product name ............................ : LED LAMP Model and/or type reference : VF-TL802B Standards .............................. : FCC CFR 47 PART 18 This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen HUAK Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen HUAK Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Date of Test............................................ : Date (s) of performance of tests ............. : Dec. 15, 2022 ~ Dec. 23, 2022 Date of Issue .......................................... : Dec. 23, 2022 Test Result .............................................. : Pass Testing Engineer : (Gary Qian) Technical Manager : (Eden Hu) Authorized Signatory : (Jason Zhou) Page 3 of 20 Report No.: HK2212155698-1E Table of Contents Page 1 . TEST SUMMARY 5 1.1 . Test Procedures And Results 5 1.2 . Information of the Test Laboratory 5 1.3 . Measurement Uncertainty 5 2. GENERAL INFORMATION 6 2.1. General Description of EUT 6 2.2. Carrier Frequency of Channels 7 2.3. Operation of EUT during testing 7 2.4. Description of Test Setup 7 2.5. Measurement Instruments List 8 3. CONDUCTED EMISSION TEST 9 3.1. Block Diagram of Test Setup 9 3.2. Conducted Power Line Emission Limit 9 3.3. Test Procedure 9 4. RADIATED EMISSIONS 12 4.1. Block Diagram of Test Setup 12 4.2. Rules and specifications 13 4.3. Test Procedure 13 4.4. Test Result 13 5. ANTENNA REQUIREMENT 17 6. PHOTOGRAPH OF TEST 18 7. PHOTOS OF THE EUT 20 Page 4 of 20 Report No.: HK2212155698-1E ** Modified History ** Revision Description Issued Data Remark Revision 1.0 Initial Test Report Release Dec. 23, 2022 Jason Zhou Page 5 of 20 Report No.: HK2212155698-1E 1. TEST SUMMARY 1.1. Test Procedures And Results DESCRIPTION OF TEST SECTION NUMBERRESULT CONDUCTED EMISSIONS TEST 18.307(c) COMPLIANT RADIATED EMISSION TEST 18.305(c) COMPLIANT Note: 1. PASS: Test item meets the requirement. 2. Fail: Test item does not meet the requirement. 3. N/A: Test case does not apply to the test object. 4. The test result judgment is decided by the limit of test standard. 1.2. Information of the Test Laboratory Shenzhen HUAK Testing Technology Co., Ltd. Add.: 1-2/F., Building B2, Junfeng Zhongcheng Zhizao Innovation Park, Heping, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Testing Laboratory Authorization: A2LA Accreditation Code is 4781.01. FCC Designation Number is CN1229. Canada IC CAB identifier is CN0045. CNAS Registration Number is L9589. 1.3. Measurement Uncertainty Measurement Uncertainty Conducted Emission Expanded Uncertainty =2.71dB, k=2 Radiated emission expanded uncertainty(9kHz-30MHz) = 3.90dB, k=2 Radiated emission expanded uncertainty(30MHz-1000MHz)= 3.90dB, k=2 Radiated emission expanded uncertainty(Above 1GHz) = 4.28dB, k=2 Page 6 of 20 Report No.: HK2212155698-1E 2. GENERAL INFORMATION 2.1. General Description of EUT Equipment: LED LAMP Model Name: VF-TL802B Series Models: N/A Model Difference: N/A Trade Mark: VAVOFO FCC ID: 2A9U2-VF-TL802B Antenna Type: Coil Antenna Antenna Gain: 0dBi Operation frequency: 112KHz~205KHz Test frequency: 127KHz Number of Channels: 1 Modulation Type: ASK Power Source: DC 12V, 2A from adapter with AC100-240V 50/60Hz, 0.8A USB Output:5V, 1A Wireless Charging Output: 5W Power Rating: DC 12V, 2A from adapter with AC100-240V 50/60Hz, 0.8A USB Output:5V, 1A Wireless Charging Output: 5W Page 7 of 20 Report No.: HK2212155698-1E 2.2. Carrier Frequency of Channels Operation Frequency each of channel Channel Frequency 1 127KHz 2.3. Operation of EUT during testing Operating Mode The mode is used: Transmitting+lighting mode 2.4. Description of Test Setup Operation of EUT during testing: AC Plug Adapter information Model:DZ024EHL120200U Input: AC100-240V, 50-60Hz, 0.8A Output: DC12V, 2A The sample was placed (0.8m (30MHz~1GHz), 0.8m (9KHz~30MHz) ) above the ground plane of 3m chamber. Measurements in both horizontal and vertical polarities were performed. During the test, each emission was maximized by: having the EUT continuously working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and considered typical configuration to obtain worst position, manipulating interconnecting cables, rotating the turntable, varying antenna height from 1m to 4m in both horizontal and vertical polarizations. The emissions worst-case are shown in Test Results of the following pages. The worst case is X position. Adapter EUT Load Page 8 of 20 Report No.: HK2212155698-1E 2.5. Measurement Instruments List Item Equipment Manufacturer Model No.Serial No. Last Cal. Cal. Inte…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 10 Report No.: HK2212155698-2E FCC TEST REPORT Test report On Behalf of CF GROUP SZKMS CO., LTD. For LED LAMP Model No.: VF-TL802B FCC ID: 2A9U2-VF-TL802B Prepared For : CF GROUP SZKMS CO., LTD. Room 101, Building 12, Renmin Road 221st, Fumin Community, Fucheng street, Long hua District, Shenzhen, Guangdong Province, China Prepared By : Shenzhen HUAK Testing Technology Co., Ltd. 1-2/F., Building B2, Junfeng Zhongcheng Zhizao Innovation Park, Heping, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Date of Test: Dec. 15, 2022 ~ Dec. 23, 2022 Date of Report: Dec. 23, 2022 Report Number: HK2212155698-2E Page 2 of 10 Report No.: HK2212155698-2E Note: 1. For a more detailed features description, please refer to the manufacturer’s specifications or the User's Manual. 2. Channel List Channel Frequency (KHz) Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) 01 127 The EUT antenna is Coil Antenna. No antenna other than that furnished by the responsible party shall be used with the device. 2. SUMMARY OF TEST RESULTS 2.1. Test procedures according to the technical standards: FCC KDB680106 D01 RF Exposure Wireless Charging Apps v03r01 FCC CFR 47 Standard Section Test Item Judgment Remark FCC CFR 47 part1, 1.1310 KDB680106 D01v03r01 (3)(3) Electric Field Strength (E) (V/m) PASS Magnetic Field Strength (H) (A/m) PASS 2.2. Measurement Uncertainty The reported uncertainty of measurement y ±U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. No. Item Uncertainty 1 All emissions, radiated(<30M)(9KHz-30MHz) ±3.90dB 2 Temperature ±0.5°C 3 Humidity ±2% Page 3 of 10 Report No.: HK2212155698-2E 2.3. Test Instruments Description Brand Model No. Frequency Range Calibrated Date Calibrated Until Exposure Level Te s t e r narda ELT-400 N-0231 Feb. 18, 2022 Feb. 17, 2023 Magnetic field probe 100cm 2 narda ELT probe 100cm2 M0675 Feb. 18, 2022 Feb. 17, 2023 NOTE: 1. The calibration interval of the above test instruments is 12 months. Page 4 of 10 Report No.: HK2212155698-2E 3. MAXIMUM PERMISSIBLE EXPOSURE Limit of Maximum Permissible Exposure Limits for Occupational / Controlled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm²) Averaging Time |E|²,|H|² or S (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842 / f 4.89 / f (900 / f)* 6 30-300 61.4 0.163 1.0 6 300-1500 F/300 6 1500-100,000 5 6 Limits for General Population / Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm²) Averaging Time |E|²,|H|² or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180 / f)* 30 30-300 27.5 0.073 0.2 30 300-1500 F/1500 30 1500-100,000 1 30 Note 1: f = frequency in MHz ; *Plane-wave equivalent power density. Note 2: For the applicable limit, see FCC 1.1310, 680106 D01 RF Exposure Wireless Charging Apps v03. Note 3: Emissions between 100 kHz to 300 kHz should be assessed versus the limits at 300 kHz in Table 1 of Section 1.1310: 614 V/m and 1.63A/m. A KDB inquiry is required to determine the applicable exposure limits below 100 kHz. Page 5 of 10 Report No.: HK2212155698-2E 4. TEST PROCEDURE a. For devices designed for typical desktop applications, such a wireless charging pads, RF exposure evaluation should be conducted assuming a user separation distance of (H-field & E- field strengths for all sides is 15cm, H-field strengths of top side is 20cm). E and H field strength measurements or numerical modeling may be used to demonstrate compliance. Measurements should be made from all sides and the top of the primary/client pair, with the 15 cm measured from the center of the probe(s) to the edge of the device. 4.1 Test Setup 4.2 Result Of Maximum Permissible Exposure Page 6 of 10 Report No.: HK2212155698-2E All test modes are tested, and the report shows only the worst mode: ANT: 5W For Full load: H-Field Strength at 15 cm (E top side: 20cm) from the edges surrounding the EUT (A/m) Field strength Test Position A Test Position B Test Position C Test Position D Test Position E Limits (A/m) uT 0.410 0.697 0.809 0.655 1.129 / A/m 0.328 0.558 0.647 0.524 0.903 1.63 Note. Calculation: A/m=uT/1.25 For Half Load mode: H-Field Strength at 15 cm (E top side: 20cm) from the edges surrounding the EUT (A/m) Field strength Test Position A Test Position B Test Position C Test Position D Test Position E Limits (A/m) uT 0.357 0.525 0.834 0.733 1.102 / A/m 0.286 0.420 0.667 0.586 0.882 1.63 Note. Calculation: A/m=uT/1.25 For No load mode: H-Field Strength at 15 cm (E top side: 20cm) from the edges surrounding the EUT (A/m) Field strength Test Position A Test Position B Test Position C Test Position D Test Position E Limits (A/m) uT 0.285 0.419 0.635 0.527 1.111 / A/m 0.228 0.335 0.508 0.422 0.889 1.63 Note. Calculation: A/m=uT/1.25 Page 7 of 10 Report No.: HK2212155698-2E Remark: According KDB 680106 D01 RF Exposure Wireless Charging App v03r01, section 5, b). The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. The E- field evaluation conducted assuming a user separation distance of 15 cm according to the KDB 680106 D01 RF Exposure Wireless Charging App v03 section 3, c). Result: The device comply with the RF exposure requirement according to 680106 D01 v03r01, section 5, b): (1) Power transfer frequency is less than 1 MHz. - The device operate in the frequency range for 112KHz~ 205KHz (2) Output power from each primary coil is less than or equal to 15 watts. - The maximum output power of ANT1 is 5W (3) The system consist of more than one source primary coils, charging one or more clients. If more than one primary coil is present, the coil pairs may be powered on at the same time. -- The transfer syste…

Text truncated - open the document above for the full version.

Test Setup Photos

Radiated Emission Conducted Emissions

Contact Information

Applicant

Xun Dong
[email protected]15818502704Fax: 15818502704

Technical Contact

CF GROUP SZKMS CO., LTD.
[email protected]

China

Test Firm

Shenzhen HUAK Testing Technology Co., Ltd.Jason Zhou
[email protected]86-755-23029901

Technical Specifications

#Rule PartsFrequency RangePower Output
1180.112 MHz - 0.205 MHz-
Confidentiality
Long Term