Solis Go Power Bank User Manual Model: SGO24 pg. 1 Introduction SOLIS GO Power bank is LTE/WCDMA multi-mode power bank a multi-function device: WIFI router & power bank. It support 3G/4G internet, WIFI, support 5 users connecting simultaneously. Any terminal device, with WIFI function, can get internet through WiFi Power bank. User Instruction 1) Using the MiFi: Power On: Press and hold the button located on the side of the device for 3 seconds to turn on the device. Connecting to the Internet: 1. Once the device is powered on, it will automatically connect to the Internet. 2. It may take 2-5 minutes to establish an internet connection, depending on the surrounding network or location. 3. Once the device successfully connects to the Internet, all three signal LEDs will become solid. 4. If the connection is not established after 5 minutes, restart the device to reconnect. Setting up Wi-Fi Connection on Your Device: 1. Go to “Network Settings" of your device. Turn on the Wi-Fi options. 2. Check the SSID printed on the back side of your MiFi Power bank device. Select the same SSID is available within the wireless network list on your device. 3. Enter the password that is printed on the back side of your MiFi Power bank device. Note: The MiFi Power bank device can support a maximum of 5 terminal devices simultaneously. 2) Using the Power Bank: 1. Plug the corresponding cable into your device. 2. Press the charge button on the front side of the MiFi Power Bank to activate the power bank mode and start charging. 3. The LED battery indicator displays the remaining power level of the MiFi Power Bank device. 4. To stop the charging, simply remove the cable from your device. 5. Avoid charging the MiFi Power Bank while it is simultaneously charging another mobile device to prevent battery life reduction. 3) Charging the MiFi Power Bank: pg. 2 You can charge the MiFi Power bank using your own charger adapter with a USB-A port for your smartphone, or by connecting it to the USB-A port on your computer. Charging the MiFi Power Bank with the Built-in Cable: 1. Pull out the Type-A cable from the MiFi Power bank device by sliding it down. 2. Plug the cable into a charger or the USB port on your computer. 3. The LED indicators will display the charging status of the MiFi Power bank. 4. When all four green LEDs are illuminated, the charging process is complete. Charging the MiFi Power Bank with your own USB cable: 1. Using a USB Type-A to C cable, connect the MiFi Power Bank’s USB Type-C port, located on the side of the device, to your USB Type-A charger or the USB port on your computer. 2. When all four green LEDs are illuminated, the charging process is complete. Function 1: Wireless WiFi Router 1. Press the button located on the front side of the device for 3 seconds to turn on the device 2. Wait until the three signal LEDs become solid. 3. And then the terminal devices, such as PC, mobile phone, and tablet pc and so on, connect to the WiFi Power Bank via Wi-Fi access point to get network data. One WiFi Power bank device can support 5 terminal devices maximum. 4. Device does not support voice, only data and will not support emergency call initiated by terminal equipment, such mobile phone, connected though WiFi. Function 2: Power Bank WiFi Power Bank device is built in 8000mAh Lithium polymer battery, which can be used as power bank, charging most of phone, MP3, Tablet PC models and so on. Connect WiFi Power Bank device and the mobile phone by the charging cable, and then press the charging power button to turn on the power bank function, and then WiFi Power Bank just begin to charge the mobile phone. To stop the charging, just remove the cable from the smart-phone. PS: (1) Please do not input charges WiFi Power Bank when it is output charging other mobile device, otherwise, the battery life will be shorten. pg. 3 (2) Please do not input charge WiFi Power Bank when it is output charging other mobile device , otherwise ,the battery life will be shorten Ports and Indicators: No. Name Status Function 1 WiFi LED White Solid WiFi is ready Unlit WiFi is not available 2 Data transfer LED White Solid Data transfer is available White Blinking Data is currently being transferred pg. 4 Unlit Data is not available or turned off 3 Cellular LED White Solid connected to cellular White Blinking attempting to connect and get signal Red Error 4 Battery LED 4 LEDs More than 75% 3 LEDs Between 50%~75% 2 LEDs Between 25%~50% 1 LEDs Between 10%~25% 1 LED Blinking Less than 10% 5 Charging button Press button Start power bank function 6 Power button Press for 3 seconds Turn on or off the device Press for 15 second Reset the device 7 Charging cable USB-A cable Charge the WiFi Power Bank 9 IOS cable Charge a iPhone or iPad 10 Type-C cable Charge a USB device via Type-C 11 Charging pins Charge the WiFi Power Bank with cabinet 12 Type-C port Charge the WiFi Power Bank 13 QR code General Safety Instructions: Make sure the WiFi Power Bank is fully charged prior to use. Under condition of low battery, the LED lights will turn off while charging a device. Recharge the Mobile Power Bank as soon as possible to avoid shortening the battery life. The battery should be charged at least every three months to avoid shortening the battery life. It is recommended to disconnect a fully-charged device to avoid unnecessary battery use. Keep the WiFi Power Bank away from fire and avoid temperatures above 70°C) when in use or 55°C when not in use. Do not get the WiFi Power Bank wet or immerse it in water. Do not wash the WiFi Power Bank with corrosive cleaner. pg. 5 Do not squeeze or puncture the WiFi Power Bank so as to avoid electrolyte leakage of lithium-ion battery. Do not attempt to disassemble, modify or fix the WiFi Power Bank. Do not use a damaged cable or power charger to charge the WiFi Power Bank. Device Specification: Model TS-61 Chipset MT6761 4XA53 @ 2.0GHz Memory 1G RAM+8G ROM Dimensions 132*68*17mm Shell material…
Text truncated - open the document above for the full version.
Rev 1/26/2023 SIMO Holdings Inc. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Company name: SIMO Holdings Inc. Address: P.O.Box 309, Ugland House, GrandCayman, KY1-1104, Cayman Islands Product Name: SOLIS GO FCC ID: 2A9UP-SOL24PB Model(s): SGO24 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing We, [ SIMO Holdings Inc.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Yours Sincerely, Name: Ginn Yin Date: 2024.06.03 Title: Manager Signature of applicant:
Rev 1/26/2023 SIMO Holdings Inc. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Company name: SIMO Holdings Inc. Address: P.O.Box 309, Ugland House, GrandCayman, KY1-1104, Cayman Islands Product Name: SOLIS GO FCC ID: 2A9UP-SOL24PB Model(s): SGO24 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing We, [SIMO Holdings Inc. ] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Yours Sincerely, Name: Ginn Yin Date: 2024.06.03 Title: Manager Signature of applicant:
Rev 1/26/2023 SIMO Holdings Inc. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2024.06.03 Company name: SIMO Holdings Inc. Address: P.O.Box 309, Ugland House, GrandCayman, KY1-1104, Cayman Islands FRN: 0033218850 Contact Person: Ginn Yin Tel.: +86-18676783109 Email: [email protected] Product Name: SOLIS GO FCC ID: 2A9UP-SOL24PB Model(s): SGO24 Ref: Attestation Statements Part 2.911(d)(7) Filing We, [ SIMO Holdings Inc.] (“the applicant”) certifies that, as of the date of the filing of the application, Skyroam Inc. is our designated U.S. agent for service of process for the above referenced FCC ID. [SIMO Holdings Inc.] accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Skyroam Inc. accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information Company Name: Skyroam Inc. Address: 611 Gateway Blvd Suite 120 South San Francisco, California 94080 United States of America Contact Person: Zou min Tel.: 086-13510975427 Email: [email protected] FRN: 0035488691 Sincerely, Applicant printed name: Ginn Yin U.S. Agent printed name: Zou min Applicant signature: U.S. Agent signature:
FCC Letter of Authorization Company: SIMO Holdings Inc. Address: P.O.Box 309, Ugland House, GrandCayman, KY1-1104, Cayman Islands Product Name: SOLIS GO Model Number: SGO24 FCC ID: 2A9UP-SOL24PB We authorize MiCOM Labs Inc, 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the above named equipment. Any individual within MiCOM Labs is authorized to act on our behalf and take action on the application. We declare that MiCOM Labs Inc, 575 Boulder Court, Pleasanton, California 94566, USA, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Name: Ginn Yin Date: 2024/06/03 Title: Manager Signature of applicant:
SIMO Holdings Inc. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 2024/06/03 Subject; Request for Confidentiality FCC ID: 2A9UP-SOL24PB To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram BOM List Block Diagram Operational Description Software Security Info Tune up procedure In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Ginn Yin
40.69mm 50.00mm 30.72mm FCC ID: 2A9UP-SOL24PB 3.8V 30.4Wh OUT IN OUT
Report No. 20240417G06548X-W8 CCIC-SET/TRF:ISAR(2024-04-29) Page 1 of 72 SAR TEST REPORT Report No.: 20240417G06548X-W8 Product Name: SOLIS GO Model Name: SGO24 Trade Name: Brand Name: SIMO FCC ID: 2A9UP-SOL24PB Applicant: SIMO Holdings Inc. Address: PO.Box PO.Box 309, Ugland House, GrandCayman, KY1-1104, Cayman Islands Test Date: 2024/04/30~2024/05/14 Issued by: CCIC Southern Testing Co., Ltd. Lab Location: Electronic Testing Building, No. 43 Shahe Road Xili Street, Nanshan District,Shenzhen, Guangdong 518055,China Tel: 86 755 26627338 Fax:86 755 26627238 Mail: [email protected] Website http://www.ccic-set.com This test report consists of 72 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The client should not use it to claim product endorsement by CCIC-SET. The test results in the report only apply to the tested sample. The CCIC-SET does not assume responsibility for any conclusions and generalizations drawn from the test results with regard to other specimens or samples of the type of the equipment represented by the test item. The test report shall be invalid without all the signatures of testing engineers, reviewer and approver. Any objections must be raised to CCIC-SET within 15 days since the date when the report is received. It will not be taken into consideration beyond this limit. Report No. 20240417G06548X-W8 CCIC-SET/TRF:ISAR(2024-04-29) Page 2 of 72 Test Report Applicant: SIMO Holdings Inc. Applicant Address: PO.Box PO.Box 309, Ugland House, GrandCayman, KY1-1104, Cayman Islands Manufacturer: SIMO Holdings Inc. Manufacturer Address: PO.Box PO.Box 309, Ugland House, GrandCayman, KY1-1104, Cayman Islands Test Standards: 47CFR §2.1093- Radiofrequency Radiation Exposure Evaluation: Portable Devices; ANSI C95.1–1992: Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz – 300 GHz.( IEEE Std C95.1-1991) IEEE 1528–2013: IEEE Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques Test Result: Pass [盖章] Tested by: Carl Wei, Test Engineer 2024-05-26 Reviewed by: Sun Jiaohui, Senior Engineer 2024-05-26 Approved by: Chris You, Manager 2024-05-26 Report No. 20240417G06548X-W8 CCIC-SET/TRF:ISAR(2024-04-29) Page 3 of 72 Contents Test Report ........................................................................................................................................... 2 1. Administrative Data ................................................................................................................... 4 2. Equipment Under Test (EUT) ................................................................................................... 5 3. SAR Summary ............................................................................................................................ 6 4. Specific Absorption Rate (SAR)................................................................................................ 8 5. Tissue check and recommend Dielectric Parameters ........................................................... 12 6. SAR measurement procedure ................................................................................................. 17 7. Conducted RF Output Power ................................................................................................. 18 8. Antenna Location:.................................................................................................................... 48 9. Scaling Factor calculation ....................................................................................................... 50 10. Test Results ............................................................................................................................... 53 11. Simultaneous Transmissions Analysis .................................................................................... 64 12. Measurement Uncertainty ....................................................................................................... 67 13. System Check Uncertainty ...................................................................................................... 69 14. Equipment List ......................................................................................................................... 71 ANNEX A: Appendix A: SAR System performance Check Plots..................................................... 72 ANNEX B: Appendix B: SAR Measurement results Plots................................................................ 72 ANNEX C: Appendix C: Calibration reports .................................................................................... 72 ANNEX D: Appendix D: SAR Test Setup ......................................................................................... 72 Report No. 20240417G06548X-W8 CCIC-SET/TRF:ISAR(2024-04-29) Page 4 of 72 1. Administrative Data 1.1 Testing Laboratory Test Site: CCIC Southern Testing Co., Ltd. Address: Electronic Testing Building, No.43, Shahe Road, Xili Street, Nanshan District, Shenzhen, Guangdong, China A2LA Lab Code: CCIC-SET is a third party testing organization accredited by A2LA according to ISO/IEC 17025:2017. The accreditation certificate number is 5721.01 FCC Registration: CCIC Southern Testing Co., Ltd. EMC Laboratory has been registered and fully described in a report filed with the FCC (Federal Communications Commission). The acceptance letter from the FCC is maintained in our files. Designation Number: CN1283, valid time is until Iune.30, 2025. ISED Registration: CCIC Southern Testing Co., Ltd. EMC Laboratory has been registered by Certification and Engineering Bureau of Industry Canada for the performance of radiated measurements with Registration No. 11185A-1 on Aug. 04, 2016, valid time is until Iune.…
Text truncated - open the document above for the full version.
Report No. 20240417G06548X-W8 CCIC-SET/TRF:ISAR(2024-04-29) 1 / 8 System Performance Check (750MHz) Type: Validation measurement Date of measurement: 05/06/2024 A. Experimental conditions. E-Field Probe SATIMO 3223-EPGO-422 Area Scan dx=8mm dy=8mm Zoom Scan 5x5x7,dx=8mm dy=8mm dz=5mm Phantom Validation plane Device Position Dipole Band 750MHz Channels Middle Signal CW(Crest factor: 1.0) B. SAR Measurement Results Frequency (MHz) 750 Relative permittivity (real part) 42.73 Conductivity (S/m) 0.91 Variation (%) 0.26 Maximum location: X=-2.00, Y=-1.00 SAR Peak: 0.14 W/kg SAR 10g (W/Kg) 0.061034 SAR 1g (W/Kg) 0.093953 SURFACE SAR VOLUME SAR Z Axis Scan Report No. 20240417G06548X-W8 CCIC-SET/TRF:ISAR(2024-04-29) 2 / 8 System Performance Check (835MHz) Type: Validation measurement Date of measurement: 05/09/2024 A. Experimental conditions. E-Field Probe SATIMO 3223-EPGO-422 Area Scan dx=8mm dy=8mm Zoom Scan 5x5x7,dx=8mm dy=8mm dz=5mm Phantom Validation plane Device Position Dipole Band 835MHz Channels Middle Signal CW(Crest factor: 1.0) B. SAR Measurement Results Frequency (MHz) 835 Relative permittivity (real part) 41.24 Conductivity (S/m) 0.92 Variation (%) -1.07 Maximum location: X=0.00, Y=-2.00 SAR Peak: 0.15 W/kg SAR 10g (W/Kg) 0.063410 SAR 1g (W/Kg) 0.100707 SURFACE SAR VOLUME SAR Z Axis Scan Report No. 20240417G06548X-W8 CCIC-SET/TRF:ISAR(2024-04-29) 3 / 8 System Performance Check (1800MHz) Type: Validation measurement Date of measurement: 04/30/2024 A. Experimental conditions. E-Field Probe SATIMO 3223-EPGO-422 Area Scan dx=8mm dy=8mm Zoom Scan 5x5x7,dx=8mm dy=8mm dz=5mm Phantom Validation plane Device Position Dipole Band 1800MHz Channels Middle Signal CW(Crest factor: 1.0) B. SAR Measurement Results Frequency (MHz) 1800 Relative permittivity (real part) 40.83 Conductivity (S/m) 1.38 Variation (%) 0.07 Maximum location: X=-1.00, Y=0.00 SAR Peak: 0.62 W/kg SAR 10g (W/Kg) 0.201084 SAR 1g (W/Kg) 0.372538 SURFACE SAR VOLUME SAR Z Axis Scan Report No. 20240417G06548X-W8 CCIC-SET/TRF:ISAR(2024-04-29) 4 / 8 System Performance Check (1900MHz) Type: Validation measurement Date of measurement: 05/07/2024 A. Experimental conditions. E-Field Probe SATIMO 3223-EPGO-422 Area Scan dx=8mm dy=8mm Zoom Scan 5x5x7,dx=8mm dy=8mm dz=5mm Phantom Validation plane Device Position Dipole Band 1900MHz Channels Middle Signal CW(Crest factor: 1.0) B. SAR Measurement Results Frequency (MHz) 1900 Relative permittivity (real part) 39.80 Conductivity (S/m) 1.42 Variation (%) -0.51 Maximum location: X=-1.00, Y=0.00 SAR Peak: 0.63 W/kg SAR 10g (W/Kg) 0.196842 SAR 1g (W/Kg) 0.395130 SURFACE SAR VOLUME SAR Z Axis Scan Report No. 20240417G06548X-W8 CCIC-SET/TRF:ISAR(2024-04-29) 5 / 8 System Performance Check (2450MHz) Type: Validation measurement Date of measurement: 05/12/2024 A. Experimental conditions. E-Field Probe SATIMO 3223-EPGO-422 Area Scan dx=8mm dy=8mm Zoom Scan 7x7x7,dx=5mm dy=5mm dz=5mm Phantom Validation plane Device Position Dipole Band 2450MHz Channels Middle Signal CW(Crest factor: 1.0) B. SAR Measurement Results Frequency (MHz) 2450 Relative permittivity (real part) 39.65 Conductivity (S/m) 1.84 Variation (%) 0.18 Maximum location: X=5.00, Y=-11.00 SAR Peak: 1.07 W/kg SAR 10g (W/Kg) 0.241164 SAR 1g (W/Kg) 0.536817 SURFACE SAR VOLUME SAR Z Axis Scan Report No. 20240417G06548X-W8 CCIC-SET/TRF:ISAR(2024-04-29) 6 / 8 System Performance Check (2600MHz) Type: Validation measurement Date of measurement: 05/14/2024 A. Experimental conditions. E-Field Probe SATIMO 3223-EPGO-422 Area Scan dx=8mm dy=8mm Zoom Scan 7x7x7,dx=5mm dy=5mm dz=5mm Phantom Validation plane Device Position Dipole Band 2600MHz Channels Middle Signal CW(Crest factor: 1.0) B. SAR Measurement Results Frequency (MHz) 2600 Relative permittivity (real part) 39.26 Conductivity (S/m) 1.98 Variation (%) 0.20 Maximum location: X=-1.00, Y=-2.00 SAR Peak: 1.04 W/kg SAR 10g (W/Kg) 0.242740 SAR 1g (W/Kg) 0.555286 SURFACE SAR VOLUME SAR Z Axis Scan Report No. 20240417G06548X-W8 CCIC-SET/TRF:ISAR(2024-04-29) 7 / 8 System Performance Check (5200MHz) Type: Validation measurement Date of measurement: 05/10/2024 A. Experimental conditions. E-Field Probe SATIMO SN 41/18 EPGO330 Area Scan dx=8mm dy=8mm Zoom Scan 7x7x12,dx=4mm dy=4mm dz=2mm Phantom Validation plane Device Position Dipole Band 5200MHz Channels Middle Signal CW(Crest factor: 1.0) B. SAR Measurement Results Frequency (MHz) 5200 Relative permittivity (real part) 35.26 Conductivity (S/m) 4.51 Variation (%) 0.21 Maximum location: X=8.00, Y=-1.00 SAR Peak: 4.53 W/kg SAR 10g (W/Kg) 0.556163 SAR 1g (W/Kg) 1.542649 SURFACE SAR VOLUME SAR Z Axis Scan Report No. 20240417G06548X-W8 CCIC-SET/TRF:ISAR(2024-04-29) 8 / 8 System Performance Check (5800MHz) Type: Validation measurement Date of measurement: 05/11/2024 A. Experimental conditions. E-Field Probe SATIMO SN 41/18 EPGO330 Area Scan dx=8mm dy=8mm Zoom Scan 7x7x12,dx=4mm dy=4mm dz=2mm Phantom Validation plane Device Position Dipole Band 5800MHz Channels Middle Signal CW(Crest factor: 1.0) B. SAR Measurement Results Frequency (MHz) 5800 Relative permittivity (real part) 34.14 Conductivity (S/m) 5.25 Variation (%) 0.04 Maximum location: X=2.00, Y=-3.00 SAR Peak: 5.73 W/kg SAR 10g (W/Kg) 0.587261 SAR 1g (W/Kg) 1.719569 SURFACE SAR VOLUME SAR Z Axis Scan
Report No. 20240417G06548X-W8 CCIC-SET/TRF:ISAR(2024-04-29) 1 / 16 Testing result (WCDMA850 ANT 2, Back, Middle, 10mm) Type: phone measurement Date of measurement: 05/09/2024 A. Experimental conditions. E-Field Probe SATIMO 3223-EPGO-422 Area Scan dx=15mm dy=15mm Zoom Scan 5x5x7,dx=8mm dy=8mm dz=5mm Phantom Validation plane Device Position Body Band WCDMA850 Channels Middle Signal WCDMA(Crest factor: 1.0) B. SAR Measurement Results Frequency (MHz) 836.6 Relative permittivity (real part) 41.24 Conductivity (S/m) 0.92 Variation (%) -0.88 Maximum location: X=6.00, Y=-37.00 SAR Peak:0.29 W/kg SAR 10g (W/Kg) 0.161893 SAR 1g (W/Kg) 0.226789 SURFACE SAR VOLUME SAR Z Axis Scan Report No. 20240417G06548X-W8 CCIC-SET/TRF:ISAR(2024-04-29) 2 / 16 Testing result (WCDMA1700 ANT 2, Front, Middle, 10mm) Type: phone measurement Date of measurement: 04/30/2024 A. Experimental conditions. E-Field Probe SATIMO 3223-EPGO-422 Area Scan dx=15mm dy=15mm Zoom Scan 5x5x7,dx=8mm dy=8mm dz=5mm Phantom Validation plane Device Position Body Band WCDMA1700 Channels Middle Signal WCDMA(Crest factor: 1.0) B. SAR Measurement Results Frequency (MHz) 1732.6 Relative permittivity (real part) 40.96 Conductivity (S/m) 1.35 Variation (%) -1.86 Maximum location: X=-8.00, Y=-15.00 SAR Peak: 1.31 W/kg SAR 10g (W/Kg) 0.561607 SAR 1g (W/Kg) 0.880218 SURFACE SAR VOLUME SAR Z Axis Scan Report No. 20240417G06548X-W8 CCIC-SET/TRF:ISAR(2024-04-29) 3 / 16 Testing result (WCDMA1900 ANT 2, Back, Middle, 10mm) Type: phone measurement Date of measurement: 05/07/2024 A. Experimental conditions. E-Field Probe SATIMO 3223-EPGO-422 Area Scan dx=15mm dy=15mm Zoom Scan 5x5x7,dx=8mm dy=8mm dz=5mm Phantom Validation plane Device Position Body Band WCDMA1900 Channels Middle Signal WCDMA(Crest factor: 1.0) B. SAR Measurement Results Frequency (MHz) 1880.0 Relative permittivity (real part) 39.84 Conductivity (S/m) 1.41 Variation (%) -2.10 Maximum location: X=-5.00, Y=-31.00 SAR Peak: 1.01 W/kg SAR 10g (W/Kg) 0.400680 SAR 1g (W/Kg) 0.659085 SURFACE SAR VOLUME SAR Z Axis Scan Report No. 20240417G06548X-W8 CCIC-SET/TRF:ISAR(2024-04-29) 4 / 16 Testing result (LTE Band 2 ANT 2, Front, Middle, 10mm) Type: phone measurement Date of measurement: 05/07/2024 A. Experimental conditions. E-Field Probe SATIMO 3223-EPGO-422 Area Scan dx=15mm dy=15mm Zoom Scan 5x5x7,dx=8mm dy=8mm dz=5mm Phantom Validation plane Device Position Body Band LTE Band 2 Channels Middle Signal LTE(Crest factor: 1.0) B. SAR Measurement Results Frequency (MHz) 1880.0 Relative permittivity (real part) 39.84 Conductivity (S/m) 1.41 Variation (%) -0.72 Maximum location: X=1.00, Y=-23.00 SAR Peak: 1.03 W/kg SAR 10g (W/Kg) 0.356165 SAR 1g (W/Kg) 0.612123 SURFACE SAR VOLUME SAR Z Axis Scan Report No. 20240417G06548X-W8 CCIC-SET/TRF:ISAR(2024-04-29) 5 / 16 Testing result (LTE Band 4 ANT 2, Front, High, 10mm) Type: phone measurement Date of measurement: 04/30/2024 A. Experimental conditions. E-Field Probe SATIMO 3223-EPGO-422 Area Scan dx=15mm dy=15mm Zoom Scan 5x5x7,dx=8mm dy=8mm dz=5mm Phantom Validation plane Device Position Body Band LTE Band 4 Channels High Signal LTE(Crest factor: 1.0) B. SAR Measurement Results Frequency (MHz) 1745.0 Relative permittivity (real part) 40.92 Conductivity (S/m) 1.36 Variation (%) 1.84 Maximum location: X=-9.00, Y=-13.00 SAR Peak: 1.79 W/kg SAR 10g (W/Kg) 0.599780 SAR 1g (W/Kg) 0.942428 SURFACE SAR VOLUME SAR Z Axis Scan Report No. 20240417G06548X-W8 CCIC-SET/TRF:ISAR(2024-04-29) 6 / 16 Testing result (LTE Band 5 ANT 2, Front, Middle, 10mm) Type: phone measurement Date of measurement: 05/09/2024 A. Experimental conditions. E-Field Probe SATIMO 3223-EPGO-422 Area Scan dx=15mm dy=15mm Zoom Scan 5x5x7,dx=8mm dy=8mm dz=5mm Phantom Validation plane Device Position Body Band LTE Band 5 Channels Middle Signal LTE(Crest factor: 1.0) B. SAR Measurement Results Frequency (MHz) 836.5 Relative permittivity (real part) 41.24 Conductivity (S/m) 0.92 Variation (%) -0.27 Maximum location:X=7.00, Y=14.00 SAR Peak: 0.15 W/kg SAR 10g (W/Kg) 0.070054 SAR 1g (W/Kg) 0.101745 SURFACE SAR VOLUME SAR Z Axis Scan Report No. 20240417G06548X-W8 CCIC-SET/TRF:ISAR(2024-04-29) 7 / 16 Testing result (LTE Band 7 ANT 2, Repeat Back, Low, 10mm) Type: phone measurement Date of measurement: 05/14/2024 A. Experimental conditions. E-Field Probe SATIMO 3223-EPGO-422 Area Scan dx=12mm dy=12mm Zoom Scan 7x7x7,dx=5mm dy=5mm dz=5mm Phantom Validation plane Device Position Body Band LTE Band 7 Channels Low Signal LTE(Crest factor: 1.0) B. SAR Measurement Results Frequency (MHz) 2510.0 Relative permittivity (real part) 39.38 Conductivity (S/m) 1.92 Variation (%) 0.10 Maximum location:X=5.00, Y=14.00 SAR Peak: 1.82 W/kg SAR 10g (W/Kg) 0.440384 SAR 1g (W/Kg) 0.948625 SURFACE SAR VOLUME SAR Z Axis Scan Report No. 20240417G06548X-W8 CCIC-SET/TRF:ISAR(2024-04-29) 8 / 16 Testing result (LTE Band 12 ANT 2, Back, Middle, 10mm) Type: phone measurement Date of measurement: 05/06/2024 A. Experimental conditions. E-Field Probe SATIMO 3223-EPGO-422 Area Scan dx=15mm dy=15mm Zoom Scan 5x5x7,dx=8mm dy=8mm dz=5mm Phantom Validation plane Device Position Body Band LTE Band 12 Channels Middle Signal LTE(Crest factor: 1.0) B. SAR Measurement Results Frequency (MHz) 707.5 Relative permittivity (real part) 42.85 Conductivity (S/m) 0.88 Variation (%) 0.27 Maximum location: X=2.00, Y=-12.00 SAR Peak: 0.12 W/kg SAR 10g (W/Kg) 0.054810 SAR 1g (W/Kg) 0.083077 SURFACE SAR VOLUME SAR Z Axis Scan Report No. 20240417G06548X-W8 CCIC-SET/TRF:ISAR(2024-04-29) 9 / 16 Testing result (LTE Band 17 ANT 2, Front, Middle, 10mm) Type: phone measurement Date of measurement: 05/06/2024 A. Experimental conditions. E-Field Probe SATIMO 3223-EPGO-422 Area Scan dx=15mm dy=15mm Zoom Scan 5x5x7,dx=8mm dy=8mm dz=5mm Phantom Validation plane Device Position Body Band LTE Band 17 Channels Middle Signal LTE(Crest factor: 1.0) B. SAR Measurement Results Frequency (MHz) 710.0 Relative permittivity (real part) 42.85 Conductivity (S/m) 0.88 Variation (%) -1.25 Maxi…
Text truncated - open the document above for the full version.
Report No. 20240417G06548X-W8 CCIC-SET/TRF:ISAR(2024-04-29) Page 1 of 79 ANNEX C: Calibration Reports 3223-EPGO-422 Probe Calibration Report SN 41/18 EPGO330 Probe Calibration Report SID750 Dipole Calibration Report SID835 Dipole Calibration Report SID1800 Dipole Calibration Report SID1900 Dipole Calibration Report SID2450 Dipole Calibration Report SID2600 Dipole Calibration Report SID5G Dipole Calibration Report Report No. 20240417G06548X-W8 CCIC-SET/TRF:ISAR(2024-04-29) Page 2 of 79 EPGO 422 Probe Calibration Report Report No. 20240417G06548X-W8 CCIC-SET/TRF:ISAR(2024-04-29) Page 3 of 79 Report No. 20240417G06548X-W8 CCIC-SET/TRF:ISAR(2024-04-29) Page 4 of 79 Report No. 20240417G06548X-W8 CCIC-SET/TRF:ISAR(2024-04-29) Page 5 of 79 Report No. 20240417G06548X-W8 CCIC-SET/TRF:ISAR(2024-04-29) Page 6 of 79 Report No. 20240417G06548X-W8 CCIC-SET/TRF:ISAR(2024-04-29) Page 7 of 79 Report No. 20240417G06548X-W8 CCIC-SET/TRF:ISAR(2024-04-29) Page 8 of 79 Report No. 20240417G06548X-W8 CCIC-SET/TRF:ISAR(2024-04-29) Page 9 of 79 Report No. 20240417G06548X-W8 CCIC-SET/TRF:ISAR(2024-04-29) Page 10 of 79 Report No. 20240417G06548X-W8 CCIC-SET/TRF:ISAR(2024-04-29) Page 11 of 79 Report No. 20…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.41 GHz - 2.46 GHz | 43.00 mW |

Solis TAG
Equipment Class
NII - Unlicensed National Information Infrastructure TX