2A9ZI-TEL-10303Remote control

Teladoc Health
Remote control - FCC ID 2A9ZI-TEL-10303 - Teladoc Health
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Feb 11, 2023
Application Purpose
Original Equipment
Date of Application
Feb 09, 2023
Equipment Note
Remote control
Frequency Range
2402.00000000 - 2480.00000000
Company
Teladoc Health
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

OperatinginstructionsofTEL-10303remotecontrol Operation: A:Bluetoothname:TeladocTVProRemote B:Pairingkey:presstheleftandrightkeyssimultaneouslyforthreesecondstoenter pairingmode; C:Lowpowerindication:Whenthepowersupplyvoltageoftheremotecontrolislessthan 2.5V,D1,D2andD5yellowlightsareonatthesametime; D:TheremotecontrolhasanAPIthatreportsbatterypowerandBluetoothconnection strength E:Whenthebatteryisreplacedandthehostisdisconnected,theremotecontrolwill rememberthepreviouslypaireddevice.Afterthebatteryisreplacedandthehostis poweredonagain,theremotecontrolshouldactivelyestablishaconnectionwith thedevice(pressthekey) F:Sleep:Iftheremotecontroldoesnotactwithin10minutes,itwillenterthedeepsleep mode.Whenthebuttonispressed,theremotecontrolwillestablishaconnection withthehostcomputer.Thepressedbuttonmustbesavedfirstandthensentdata. Thetimetoconnectbackshouldnotexceed2seconds This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. Warning: changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment The devices has been evaluated to meet general RF exposure requirement the device can be used in portable exposure condition without restriction

Attestation Statements

C5266091_X24_Ed.1 1/1 “AttestationStatements” TO: OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 TheCommissionadoptedrulesthatprohibitequipmentauthorizationfor“covered” telecommunicationsequipmentandvideosurveillanceequipmentproducedbyentitiesidentified ontheCommission’sCoveredList 1 ,whichisperiodicallyupdated.SeetheCoveredListformore details.ThisAttestationStatementistoconfirmthatwefollowtheSection2.911(d)(5)(i)-(ii) Applicant Companyname:TeladocHealth Granteecode:2A9ZI FCCID:2A9ZI-TEL-10303 ContactName:DannySanchez Address:7406HollisterAveGoleta,CA93117 TelephoneNo:8057244892 FaxNo:8057244892 Email:[email protected] i.[TeladocHealth](“theapplicant”)certifiesthattheequipmentforwhich authorizationissoughtisnot“covered”equipmentprohibitedfromreceiving anequipmentauthorizationpursuanttosection2.903oftheFCCrules.The applicantmustsignthiscertification. ii.[TeladocHealth](“theapplicant”)certifiesthat,asofthedateofthefilingof theapplication,theapplicant[isnot]identifiedontheCoveredListasan entityproducing“covered”equipment.Theapplicantmustsignthis certification. Date:2/07/2023 Applicant’sName:DannySanchez Title:Manager Signature 1 TheCommission’sCoveredListispublishedbythePublicSafetyandHomelandSecurityBureauandpostedonthe Commission’swebsite.ThisCoveredList,whichisperiodicallyupdated,identifiesparticularequipment,producedby particularentities,thatconstitutes“covered”equipment.https://www.fcc.gov/supplychain/coveredlist

Attestation Statements

BA20220940149 Entity Details Corporation NameTELADOC HEALTH, INC. Entity No.3954016 Formed InDELAWARE Street Address of Principal Office of Corporation Principal Address2 MANHATTANVILLE ROAD SUITE 203 PURCHASE, NY 10577 Mailing Address of Corporation Mailing AddressTAX DEPARTMENT 1945 LAKEPOINTE DR. LEWISVILLE, TX 75057 Attention Street Address of California Office of Corporation Street Address of California OfficeNone Officers Officer NameOfficer AddressPosition(s) JASON GOREVIC32 NORMAN DRIVE RYE,, NY 10580 Chief Executive Officer Adam C Vandervoort2 Manhattanville Rd Suite 203 Purchase, NY 10577 Secretary Mark Hirschhorn8 Avon Road, Larchmont,, NY 10538 Chief Financial Officer Additional Officers Officer NameOfficer AddressPositionStated Position None Entered Agent for Service of Process California Registered Corporate Agent (1505)CORPORATION SERVICE COMPANY WHICH WILL DO BUSINESS IN CALIFORNIA AS CSC - LAWYERS INCORPORATING SERV Registered Corporate 1505 Agent Type of Business Type of BusinessHEALTH SERVICES Email Notifications Opt-in Email NotificationsNo, I do NOT want to receive entity notifications via email. I prefer notifications by USPS mail. Labor Judgment No Officer or Director of this Corporation has an outstanding final judgment issued by the Division of Labor Standards Enforcement or a court of law, for which no appeal therefrom is pending, for the violation of any wage order or provision of the Labor Code. STATE OF CALIFORNIA Office of the Secretary of State STATEMENT OF INFORMATION CORPORATION California Secretary of State 1500 11th Street Sacramento, California 95814 (916) 653-3516 B1153-5497 10/05/2022 5:14 AM Received by California Secretary of State Page 1 of 2 For Office Use Only -FILED- File No.: BA20220940149 Date Filed: 10/5/2022 Electronic Signature By signing, I affirm that the information herein is true and correct and that I am authorized by California law to sign. Jason Gorevic Signature 10/05/2022 Date B1153-5498 10/05/2022 5:14 AM Received by California Secretary of State Page 2 of 2

Cover Letter(s)

C5266091_X8_Ed.1 1/1 TeladocHealth LetterofAuthorization Company:TeladocHealth Address:7406HollisterAveGoleta,CA93117 ProductName:Remotecontrol ModelNumber:TEL-10303 FCCIdentifier:2A9ZI-TEL-10303 WeauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdelCarme,s/n, 08193Bellaterra,Spain,toactonourbehalfonallmattersconcerningthe abovenamedequipment. AnyindividualwithinLGAITechnologicalCenterS.A.isauthorizedtoactonour behalfandtakeactionontheapplication. WedeclarethatauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdel Carme,s/n,08193Bellaterra,Spain,isallowedtoforwardallinformation relatedtotheapprovalprojecttotheFederalCommunicationCommissionand todiscussanyissuesconcerningtheapprovalapplication.Anyandallacts carriedoutbyLGAITechnologicalCenterS.A.onourbehalfshallhavethe sameeffectasactsofourown. Name:DannySanchezDate:Feb2.2023 Title:Manager Signatureofapplicant:

Cover Letter(s)

C5266091_X10_Ed.2 1/1 TeladocHealth OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date:Feb22023 Subject:RequestforConfidentiality FCCID:2A9ZI-TEL-10303 ToWhomItMayConcern, PursuanttotheprovisionsofSections0.457and0.459ofCommission'srules (47CFR0.457,0.459),wearerequestingtheCommissiontowithholdthefollowing attachment(s)asconfidentialdocumentfrompublicdisclosure. ExhibitsLong-Term Confidentiality Short-Term Confidentiality NOTE2 IDLabel/LocationNoNo AttestationStatement ☒☐ ExternalPhotosNo ☐ BlockDiagram ☒☐ Schematics ☒☐ TestReportNoNo TestSetupPhotosNo ☐ User’sManual ☐ NOTE 1 ☐ InternalPhotos ☐ NOTE 1 ☐ PartsList/TuneUp ☐☐ RFExposureInfoNoNo OperationalDescription ☒☐ CoverLetter(s)NoNo SDRSoftware/SecurityInfo ☐ No NOTE1:Long-TermConfidentialitymaybepermittedunderspecialconditions(SeeII.LONG-TERM CONFIDENTIALITY,Section3ofKDB726920,uselastinforce) NOTE2:Short-TermConfidentialitycanberequestedforamaximumof180daysfromthedateofthegrant. Abovementioneddocumentcontainsdetailedsystemandequipmentdescriptionare consideredasproprietaryinformationinoperationoftheequipment.Thepublic disclosureofabovedocumentsmightbeharmfultoourcompanyandwouldgive competitoranunfairadvantageinthemarket. C5266091_X10_Ed.2 1/1 Incaseofshort-termConfidentiality,theapplicantrequeststheexhibitsselected abovearewithheldfrompublicviewforaperiodof______daysfromthedateofthe GrantofEquipmentAuthorizationandpriortomarketing. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondentduringcertificationreviewprocesscannotbegrantedasconfidential documentsandthoseinformationwillbeavailableforpublicreviewoncethegrantof equipmentauthorizationisissued. Sincerely, Name:DannySanchezDate:Feb2.2023 Title:Manager Signatureofapplicant:

External Photos

Page1of3ReportNo.:FCS202212170 Externalphotos Photo1 Photo2 Page2of3ReportNo.:FCS202212170 Photo3 Photo4 Page3of3ReportNo.:FCS202212170 Photo5 Photo6

ID Label/Location Info

LabelandLabelLocation FCCID:2A9ZI-TEL-10303

Internal Photos

Page1of2ReportNo.:FCS202212170 Internalphotos Photo1 Photo2 Page2of2ReportNo.:FCS202212170 Photo3 Photo4 PCBantenna

RF Exposure Info

FCCRFExposure EUTDescription:Remotecontrol ModelNo.:TEL-10303 FCCID:2A9ZI-TEL-10303 Equipmenttype:PortableDevice 1.TestProcedure AccordingtoKDB447498D01GeneralRFExposureGuidancev06 The1-gand10-gSARtestexclusionthresholdsfor100MHzto6GHzattest separationdistances ≤ 50mmaredeterminedby: [(max.powerofchannel,includingtune-uptolerance,mW)/ (min.testseparationdistance,mm)] · [ √ f(GHz)] ≤ 3.0for1-gSARand ≤ 7.5for10-g extremitySAR, where f(GHz)istheRFchanneltransmitfrequencyinGHz PoweranddistanceareroundedtothenearestmWandmmbefore calculationTheresultisroundedtoonedecimalplaceforcomparison Thetestexclusionsareapplicableonlywhentheminimumtestseparation distanceis≤50mmandfortransmissionfrequenciesbetween100MHzand6GHz. Whentheminimumtestseparationdistanceis<5mm,adistanceof5mmisappliedto determineSARtestexclusion. 2.TestResultofRFExposureEvaluation [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparation distance,mm)]·[√f(GHz)]=3.5974/5*√2.402=1.1151≤3.0ThresholdatwhichnoSARrequiredis and≤3.0for1-gSAR,Separationdistanceis5mm. Mode Channel Freq.(MHz) Maximum Conducted Output Power(PK) AntennaGain (dBi) Antenna gainnumeric Tune-up power (dBm) Maxtune- uppower (W) GFSK 24024.561.51.414.56±10.0035974 24404.481.51.414.48±10.0035318 24804.531.51.414.53±10.0035727

Test Report

FCCTestReport ReportNo:FCS202212170W01 Issuedfor Applicant: TeladocHealth Address: 7406HollisterAveGoleta,CA93117 ProductName: Remotecontrol BrandName: N/A ModelName: TEL-10303 SeriesModel: N/A FCCID: 2A9ZI-TEL-10303 IssuedBy:FluxComplianceServiceLaboratory Add:Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-Tech Industrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com Page 2 of38ReportNo.:FCS202212170W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com TESTRESULTCERTIFICATION Applicant’sName......................:TeladocHealth Address......................................:7406HollisterAveGoleta,CA93117 Manufacture'sName................:TeladocHealth Address......................................:7406HollisterAveGoleta,CA93117 ProductDescription ProductName...........................:Remotecontrol BrandName ............................... :N/A ModelName .............................. :TEL-10303 SeriesModel .............................. :N/A TestStandards..........................:FCCRulesandRegulationsPart15SubpartC,Section247 TestProcedure .......................... :ANSIC63.10:2013 ThisdevicedescribedabovehasbeentestedbyFluxComplianceServiceLaboratory,thetestresults showthattheequipmentundertest(EUT)isincompliancewiththeFCCrequirements.Anditis applicableonlytothetestedsampleidentifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofFluxCompliance ServiceLaboratory,thisdocumentmaybealteredorrevisedbyFluxComplianceServiceLaboratory, personalonly,andshallbenotedintherevisionofthedocument.. DateofTest .................................. : Date(s)ofperformanceoftests . :Dec27,2022~Jan4,2023 DateofIssue.................................:Jan5,2023 TestResult....................................:Pass Testedby: (ScottShen) Reviewedby : (DukeQian) Approvedby: (JackWang) Page 3 of38ReportNo.:FCS202212170W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com TableofContentsPage 1.SUMMARYOFTESTRESULTS..............................................................................................6 1.1TESTFACTORY................................................................................................................7 1.2MEASUREMENTUNCERTAINTY....................................................................................7 2.GENERALINFORMATION......................................................................................................8 2.1GENERALDESCRIPTIONOFTHEEUT.........................................................................8 2.2BLOCKDIGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED.............10 2.3DESCRIPTIONOFNECESSARYACCESSORIESANDSUPPORTUNITS................11 2.4EQUIPMENTSLIST.........................................................................................................12 3.CONDUCTEDEMISSIONMEASUREMENT.........................................................................13 4.6DBBANDWIDTH..................................................................................................................16 4.1Limit..................................................................................................................................16 4.2TestProcedure.................................................................................................................16 4.3Testsetup.........................................................................................................................16 4.4Testresults.......................................................................................................................16 4.5OriginalTestData............................................................................................................17 5.CONDUCTEDOUTPUTPOWER...........................................................................................19 5.1LIMIT................................................................................................................................19 5.2TESTPROCEDURE........................................................................................................19 5.3TESTSETUP...................................................................................................................19 5.5TESTRESULTS..............................................................................................................19 6.BANDEDGEANDSPURIOUS(CONDUCTED)....................................................................20 6.1LIMIT................................................................................................................................20 6.2TESTPROCEDURE........................................................................................................20 6.3TESTSETUP...................................................................................................................20 6.4TESTRESULTS..............................................................................................................21 6.5Originaltestdata..............................................................................................................21 7.POWERSPECTRALDENSITY..............................................................................................24 7.1LIMIT................................................................................................................................24 7.2TESTPROCEDURE........................................................................................................24 7.3TESTSETUP.................................................................................................................24 7.4TESTRESULTS............................................................................................…

Text truncated - open the document above for the full version.

Test Report

1:天线型号:倒F天线(IFA)(Antenna type: inverted F antenna) 2:天线类型:PCB沉板天线 (Antenna type: PCB sinking plate antenna ) 3:增益:1.5dB (Gain: 1.5dB ) 4:天線尺寸如圖一所示 (Antenna size is shown in Figure 1 圖一18.2*5.5mm Freq (MHz 5:天线效率(Efficiency of antenna) ) Effi (%) Effi (dB) Gain (dBi) 240036.8-4.30.8 241040.3-3.91.3 242040.4-3.81.4 243041.6-3.81.5 244040.5-3.71.4 245040.7-3.71.4 246041.2-3.81.5 247040.0-41.4 248038.0-4.21.1 249035.9-4.50.9 250034-4.70.7 6. 天線性能如圖二所示,工作頻段覆蓋整個 2.4G ISM 頻段。(The antenna performance is shown in Figure II, and the operating band covers the entire 2.4GISM band) 图二 72430MHz is the maximum gain frequency 2D 和3D增益如下,達到1.5dB左右: 圖三 圖四天線增益

Test Setup Photos

Page 1 of2ReportNo.:FCS202212170 Blow1GHzforradiatedemissiontestsetup Above1GHzforradiatedemissiontestsetup

Contact Information

Applicant

Danny Sanchez(Manager)
[email protected]805-724-4892Fax: 805-724-4892

Technical Contact

Flux Compliance Service LaboratoryAndy yue
[email protected]86-769-27280901

Dongguan · China

Non-Technical Contact

Flux Compliance Service LaboratoryAndy yue
[email protected]86-769-27280901

Test Firm

Flux Compliance Service LaboratoryAndy Yue
[email protected]13510297284

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.86 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.