FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Visteon Electronics Germany GmbH/
  3. 2AA98A

2AA98AVehicle Immobilizer / VW MQB Instrument Cluster

Visteon Electronics Germany GmbH
Vehicle Immobilizer / VW MQB Instrument Cluster - FCC ID 2AA98A - Visteon Electronics Germany GmbH
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Mar 20, 2014
Application Purpose
Original Equipment
Date of Application
Mar 18, 2014
Equipment Note
Vehicle Immobilizer / VW MQB Instrument Cluster
Frequency Range
0.12500000 - 0.12500000
Company
Visteon Electronics Germany GmbH
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗
↗
↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

American Certification Body Inc. 6731 Whittier Ave, Suite C110 McLean, VA22101 Date: 25.02.2014 FCC ID: 2AA98A IC: 11505-A Subject: Compliance Statement in Vehicle Manual Dear Sirs, Our client’s product with the above listed product identification(s) is a low frequency transmitter. The product will be installed in vehicles before they will be placed into the market. Hereby they assure that the following caution statement as per CFR 47, §15.21 is included in the owner’s manual of the vehicles: The title “CAUTION TO USERS” or “FCC WARNING”: “NOTE” or relevant title and “Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.” In addition, our client also assures that the following statement will be included in the manual as per CFR 47, §15.19(a)(3) and RSS-GEN 7.1.3: This device complies with Part 15 of the FCC Rules and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Yours sincerely, Thomas Ring Manager Certification CSA Group Bayern GmbH Ohmstr. 1-4, 94342 Strasskirchen, Germany

Cover Letter(s)

Request for Confidentiality Date: 25.02.2014 Subject: Confidentiality Request for: FCC ID: 2AA98A IC: 11505A-A Pursuant to FCC 47 CRF 0.457(d) and 0.459 and IC RSP-100, Section 10, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term External Photos Short Term Permanent* 1 Internal Photos Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Parts List & Placement/BOM Short Term Permanent Tune-Up Procedure Short Term Permanent Schematics Short Term Test Setup Photos Short Term Permanent* User’s Manual *Note: ______(Insert Explanation as Necessary)______ Johnson Controls GmbH has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of (0) days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify ACB in the event information regarding the product or the product is made available to the public. ACB will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. NOTE for Industry Canada Applications: The applicant understands that until such time that IC distinguishes between Short Term and Permanent Confidentiality, either type of marked exhibit above will simply be marked Confidential when submitted to IC. Sincerely, By: Manager Certification Thomas Ring Title Name 1 - The asterisked items (*) require further justification before permanent confidentiality will be allowed. These also currently require review by the FCC under their Permit-But-Ask policy before the grant is issued and can delay completion of an application. Further justification should be added to the note above. One such example for a potted device would be: “The EUT is FULLY potted using a non-removable epoxy based material. Removal of potting material causes irreparable damage to internal circuitry. See photographs exhibits that outline the device before and after potting.”

Cover Letter(s)

American Certification Body Inc. 6731 Whittier Ave, Suite C110 McLean, VA22101 Date: 21.03.2014 FCC ID: 2AA98A IC: 11505A-A This is to state for our client’s product “Kombiinstrument 1” with the above listed product identification a Class 1 Permissive Change was done at the same time as the original application. Two new electrical configurations wer also developed in parallel: Kombiinstrument 2 Kombiinstrument 3 These two different electrical configurations have the same external appearance but they have different internal appearance and different electrical layout. However, the EMC and RF performance of all thre electrical variants are the same, therefore the two other electrical variants are immediately added under a Class 1 Permissive Change. The details of the other two electrical variants are included in this application, for information. If you have any questions, please feel free to contact me at the address shown below. Yours sincerely, Thomas Ring Manager Certification CSA Group Bayern GmbH Ohmstr. 1-4 94342 Strasskirchen Germany

External Photos

FCC ID: 2AA98A CSA Group Bayern GmbH File No. T36002-02-02KJ, page 5 of 26 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440 Rev. No. 3.0, 2014-01-30 3 E Q U I P M E N T U N D E R T E S T 3.1 Photo documentation of the EUT FCC ID: 2AA98A CSA Group Bayern GmbH File No. T36002-02-02KJ, page 6 of 26 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440 Rev. No. 3.0, 2014-01-30 FCC ID: 2AA98A CSA Group Bayern GmbH File No. T36002-02-02KJ, page 7 of 26 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440 Rev. No. 3.0, 2014-01-30

Internal Photos

FCC ID: 2AA98A CSA Group Bayern GmbH File No. T36002-02-02KJ, page 9 of 26 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440 Rev. No. 3.0, 2014-01-30 FCC ID: 2AA98A CSA Group Bayern GmbH File No. T36002-02-02KJ, page 10 of 26 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440 Rev. No. 3.0, 2014-01-30 FCC ID: 2AA98A CSA Group Bayern GmbH File No. T36002-02-02KJ, page 11 of 26 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440 Rev. No. 3.0, 2014-01-30

Internal Photos

Model Variant: Basic

Internal Photos

Model Variant: Color

Internal Photos

Model Variant: Medium

Test Report

FCC ID: 2AA98A CSA Group Bayern GmbH File No. T36002-02-02KJ, page 1 of 26 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440 Rev. No. 3.0, 2014-01-30 EMI − T E S T R E P O R T - FCC Part 15.209 - Test Report No. : T36002-02-02KJ 27. February 2014 ______________________________________________________________________________________________ Date of issue Type / Model Name : JCI MQB IC / Kombiinstrument Product Description : Vehicle Immobilizer / VW MQB Instrument Cluster Applicant : Johnson Controls GmbH Address : Mittelstr. 11-13 D-40789 Monheim Manufacturer : Johnson Controls GmbH Address : Mittelstr. 11-13 D-40789 Monheim Licence holder : Johnson Controls GmbH Address : Mittelstr. 11-13 D-40789 Monheim Test Result according to the standards listed in clause 1 test standards: POSITIVE The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permission of the test laboratory. FCC ID: 2AA98A CSA Group Bayern GmbH File No. T36002-02-02KJ, page 2 of 26 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440 Rev. No. 3.0, 2014-01-30 Contents 1 T E S T S T A N D A R D S 3 2 S U M M A R Y 4 3 E Q U I P M E N T U N D E R T E S T 5 3.1 Photo documentation of the EUT 5 3.2 Power supply system utilised 12 3.3 Short description of the equipment under test (EUT) 12 4 T E S T E N V I R O N M E N T 13 4.1 Address of the test laboratory 13 4.2 Environmental conditions 13 4.3 Statement of the measurement uncertainty 13 4.4 Measurement protocol for FCC 14 4.5 Determination of worst case measurement conditions 15 5 T E S T C O N D I T I O N S A N D R E S U L T S 16 5.1 Conducted emissions 16 5.2 Field strength of the fundamental wave 17 5.3 Spurious emissions (magnetic field) 9 kHz – 30 MHz 20 5.4 Emission Bandwidth 24 6 U S E D T E S T E Q U I P M E N T A N D A C C E S S O R I E S 26 FCC ID: 2AA98A CSA Group Bayern GmbH File No. T36002-02-02KJ, page 3 of 26 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440 Rev. No. 3.0, 2014-01-30 1 T E S T S T A N D A R D S The tests were performed according to following standards: FCC Rules and Regulations Part 15, Subpart A - General (September, 2013) Part 15, Subpart A, Section 15.31 Measurement standards Part 15, Subpart A, Section 15.33 Frequency range of radiated measurements Part 15, Subpart A, Section 15.35 Measurement detector functions and bandwidths FCC Rules and Regulations Part 15, Subpart C - Intentional Radiators (September, 2013) Part 15, Subpart C, Section 15.203 Antenna requirement Part 15, Subpart C, Section 15.204 External radio frequency power amplifiers and antenna modifications Part 15, Subpart C, Section 15.205 Restricted bands of operation Part 15, Subpart C, Section 15.207 Conducted limits Part 15, Subpart C, Section 15.209 Radiated emission limits, general requirements ANSI C63.4: 2003 Methods of Measurement of Radio-Noise Emissions from Low- Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz. ANSI C95.1: 2005 IEEE Standard for Safety Levels with respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz CISPR 16-4-2: 2003 Uncertainty in EMC measurement CISPR 22: 2005 Information technology equipment EN 55022: 2006 FCC ID: 2AA98A CSA Group Bayern GmbH File No. T36002-02-02KJ, page 4 of 26 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440 Rev. No. 3.0, 2014-01-30 2 S U M M A R Y GENERAL REMARKS: The carrier frequency is 125.0 kHz. FINAL ASSESSMENT: The equipment under test fulfills the EMI requirements cited in clause 1 test standards. Date of receipt of test sample : acc. to storage records Testing commenced on : 21 January 2014 Testing concluded on : 31 January 2014 Checked by: Tested by: Klaus Gegenfurtner Teamleader Radio Josef Knab FCC ID: 2AA98A CSA Group Bayern GmbH File No. T36002-02-02KJ, page 5 of 26 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440 Rev. No. 3.0, 2014-01-30 3 E Q U I P M E N T U N D E R T E S T 3.1 Photo documentation of the EUT FCC ID: 2AA98A CSA Group Bayern GmbH File No. T36002-02-02KJ, page 6 of 26 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440 Rev. No. 3.0, 2014-01-30 FCC ID: 2AA98A CSA Group Bayern GmbH File No. T36002-02-02KJ, page 7 of 26 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440 Rev. No. 3.0, 2014-01-30 FCC ID: 2AA98A CSA Group Bayern GmbH File No. T36002-02-02KJ, page 8 of 26 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440 Rev. No. 3.0, 2014-01-30 FCC ID: 2AA98A CSA Group Bayern GmbH File No. T36002-02-02KJ, page 9 of 26 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440 Rev. No. 3.0, 2014-01-30 FCC ID: 2AA98A CSA Group Bayern GmbH File No. T36002-02-02KJ, page 10 of 26 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440 Rev. No. 3.0, 2014-01-30 FCC ID: 2AA98A CSA Group Bayern GmbH File No. T36002-02-02KJ, page 11 of 26 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440 Rev. No. 3.0, 2014-01-30 FCC ID: 2AA98A CSA Group Bayern GmbH File No. T36002-02-02KJ, page 12 of 26 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440 Rev. No. 3.0, 2014-01-30 3.2 Power supply system utilised Power supply voltage: : 13.5 V /DC 3.3 Short description of the equipment under test (EUT) The EuT is an instrument cluster for vehicles based on the VW MQB platform. It includes immobilizer functionality based on RF communication to protect the vehicle against unauthorized movement. The VW MQB Instrument Cluster is available in multiple variants to fit a number of c…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: 2AA98A CSA Group Bayern GmbH File No. T36002-02-02KJ, page 17 of 26 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440 Rev. No. 3.0, 2014-01-30 5.2 Field strength of the fundamental wave For test instruments and accessories used see section 6 Part CPR 1. 5.2.1 Description of the test location Test location: OATS1 Test distance: 3 metres 5.2.2 Photo documentation of the test set-up FCC ID: 2AA98A CSA Group Bayern GmbH File No. T36002-02-02KJ, page 20 of 26 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440 Rev. No. 3.0, 2014-01-30 5.3 Spurious emissions (magnetic field) 9 kHz – 30 MHz For test instruments and accessories used see section 6 Part SER 1. 5.3.1 Description of the test location Test location: OATS1 Test distance: 3 metres 5.3.2 Photo documentation of the test set-up FCC ID: 2AA98A CSA Group Bayern GmbH File No. T36002-02-02KJ, page 24 of 26 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440 Rev. No. 3.0, 2014-01-30 5.4 Emission Bandwidth For test instruments and accessories used see section 6 Part MB. 5.4.1 Description of the test location Test location: AREA4 5.4.2 Photo documentation of the test set-up Fundamental [kHz] See Plot 1 20dB Bandwidth F1 20dB Bandwidth F2 Measured Bandwidth [kHz] 124.94 122.33 127.44 5.11

Contact Information

Applicant

Markus Gauer(Managing Director)
[email protected]49-721-47661620Fax: 49-721-47661620

Technical Contact

CSA Group Bayern GmbHKlaus Gegenfurtner
[email protected]4994249481

Ohmstrasse 1-4 · Strasskirchen · Germany

Test Firm

CSA Group Bayern GmbHThomas Weise
[email protected]49-9424-9481-150Fax: 49-9424-9481-240

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.125 MHz - 0.125 MHz-
Confidentiality
Long Term

Other Applications from Visteon Electronics Germany GmbH

BCP - 01 - FCC ID 2AA98-BCP01 - Visteon Electronics Germany GmbH
2AA98-BCP01

BCP - 01

Mar 02, 2021

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter