FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Corsair Memory, Inc./
  3. 2AAFM-RGP0195

2AAFM-RGP0195Dongle

Corsair Memory, Inc.

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Sep 18, 2026
Application Purpose
Original Equipment
Equipment Note
Dongle
Frequency Range
2403.00000000 - 2480.00000000
Company
Corsair Memory, Inc.
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Rev 1/26/2023 Corsair Memory, Inc. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: Jun-29-2026 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2AAFM-RGP0195 [Corsair Memory, Inc.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. [Corsair Memory, Inc.] (“the applicant”) certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Device is inherently compliant based on hardware limitations or software controls. or A Software Bill of Materials (SBOM) is provided to the TCB for review, and The end-user or third parties cannot install additional software on this device. Sincerely, (Applicant signature) 2026/09/09 (Applicant printed name) Rick Ho Title of authorized signer: Product Compliance Team Rev 1/26/2023 Corsair Memory, Inc. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: Jun-29-2026 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: 2AAFM-RGP0195 [Corsair Memory, Inc.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, (Applicant signature) 2026/09/09 (Applicant printed name) Rick Ho Title of authorized signer: Product Compliance Team

Attestation Statements

Rev 2 Corsair Memory, Inc. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA FCC ID: 2AAFM-RGP0193, 2AAFM-RGP0195, 2AAFM-RGP0196, 2AAFM-RGP0194, 2AAFM- RGP0197 FRN: 0022739338 Date of Filing to TCB: Sep-9-2026 Ref: Attestation Statements Part 2.911(d)(7) Filing [ Corsair Memory, Inc. ] (“the applicant”) certifies that, as of the date of the filing of the application, [ Corsair Memory, Inc. ]is our designated U.S. agent for service of process for the above referenced FCC ID. [ Corsair Memory, Inc. ] accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment and will notify the TCB/FCC in a timely manner if the US Processing Agent changes. [ Corsair Memory, Inc. ] accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Name: Corsair Memory, Inc. FRN: 0022739338 Address: 115 North McCarthy Blvd, Milpitas, CA 95035, USA Contact Person: Rick Ho Tel.: 886226973918 ext 307 Email: [email protected] Sincerely, (Applicant printed name) Rick Ho (Applicant signature) (US Local Agent printed name) Rick Ho (US Local Agentsignature)

Cover Letter(s)

Rev 11/20/07 Corsair Memory, Inc. Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: 2AAFM-RGP0195 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Block Diagram, Schematics, Operational Description Block Diagram, SCH, Technical Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Pursuant to DA04-1705 June 15, 2004 of the Commission’s public notice, we also request 180 days temporary confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name External Photos,Internal Photos,Manual, Test photos External Photos,Internal Photos,Manual, Test photos Sincerely, (signature) (printed name) Rick Ho Date: 2026/9/10

Cover Letter(s)

Corsair Memory, Inc. Date: Sep-9-2026 FCC ID: 2AAFM-RGP0193, 2AAFM-RGP0195, 2AAFM-RGP0196, 2AAFM-RGP0194, 2AAFM-RGP0197 A U T H O R I Z A T I O N L E T T E R To whom it may concern: Corsair Memory, Inc. hereby authorize Madison Luo / Assistant EMC Manager of Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch to act on its behalf in all matters relating to FCC application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by Madison Luo / Assistant EMC Manager of Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch on Corsair Memory, Inc.’s behalf, within the scope of the powers grantedherein, shall have the same effect as acts of its own. If you have any questions regarding the authorization, please don’t hesitate to contact us. Sincerely yours, ----------------------------------- Name of authorized signer: Rick Ho Title of authorized signer: Product Compliance Team Company Name: Corsair Memory, Inc. Address: 115 North McCarthy Blvd, Milpitas, CA 95035, USA Tel.: 886-2-2697-3918 E-mail: [email protected]

ID Label/Location Info

The trademark printed on the front, The Label printed on the back (location: lower layer of buckle

RF Exposure Info

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 6 Report Version 1 Test Report No.: FM2606WDG0438-2 RF EXPOSURE REPORT Applicant CORSAIR MEMORY, Inc. Address 115 North McCarthy Blvd, Milpitas, CA 95035, USA Manufacturer or Supplier CORSAIR MEMORY, Inc. Address 115 North McCarthy Blvd, Milpitas, CA 95035, USA Product Dongle Brand Name or or Model RGP0195 Additional Model & Model Difference N/A Date of tests Aug. 12, 2026 ~ Aug. 18, 2026 FCC Part 2 (Section 2.1093) KDB 447498 D01 V06 IEEE C95.1 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Prepared by Andrew Sha Project Engineer / EMC Department Approved by Glyn He Assistant Manager / EMC Department Date: Sep. 10, 2026 This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 6 Report Version 1 Test Report No.: FM2606WDG0438-2 TABLE OF CONTENTS RELEASE CONTROL RECORD ................................................................................ 3 1. CERTIFICATION .............................................................................................. 4 2. RF EXPOSURE DEFINE ................................................................................. 5 3. CLASSIFICATION ........................................................................................... 5 4. CALCULATED RESULT OF MAXIMUM CONDUCTED POWER .................... 6 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 6 Report Version 1 Test Report No.: FM2606WDG0438-2 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED FM2606WDG0438-2 Original release Sep. 10, 2026 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 6 Report Version 1 Test Report No.: FM2606WDG0438-2 1. CERTIFICATION FCC ID: 2AAFM-RGP0195 PRODUCT: Dongle BRAND NAME: or or MODEL NO.: RGP0195 ADDITIONAL NO.: N/A APPLICANT: CORSAIR MEMORY, Inc. STANDARDS: FCC Part 2 (Section 2.1093) KDB 447498 D01 V06 IEEE C95.1 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 5 of 6 Report Version 1 Test Report No.: FM2606WDG0438-2 2. RF EXPOSURE DEFINE The corresponding SAR Exclusion Threshold condition, listed below: 1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,16 where ➢  f(GHz) is the RF channel transmit frequency in GHz ➢  Power and distance are rounded to the nearest mW and mm before calculation ➢  The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. 2) At 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test exclusion threshold is determined according to the following: a) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·( f(MHz)/150)] mW, at 100MHz to 1500 MHz b) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·10] mW at > 1500 MHz and ≤ 6 GHz 3) At frequencies below 100 MHz, the following may be considered for SAR test exclusion. a) The threshold …

Text truncated - open the document above for the full version.

Test Report

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 50 Report Version A Test Report No.: RF2606WDG0438-2 TEST REPORT Applicant: CORSAIR MEMORY, Inc. Address: 115 North McCarthy Blvd, Milpitas, CA 95035, USA Manufacturer or Supplier CORSAIR MEMORY, Inc. Address 115 North McCarthy Blvd, Milpitas, CA 95035, USA Product: Dongle Brand Name: or or Model: RGP0195 Additional Model & Model Difference N/A Date of tests: Aug. 12, 2026 ~ Aug. 18, 2026 the tests have been carried out according to the requirements of the following standard: FCC Part 15, Subpart C, Section 15.249 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Prepared by Andrew Sha Project Engineer / EMC Department Approved by Glyn He Assistant Manager / EMC Department Date: Sep. 10, 2026 This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 50 Report Version A Test Report No.: RF2606WDG0438-2 TABLE OF CONTENTS RELEASE CONTROL RECORD ............................................................................................................ 4 1 SUMMARY OF TEST RESULTS .................................................................................................... 5 2 MEASUREMENT UNCERTAINTY ................................................................................................. 5 3 GENERAL INFORMATION ............................................................................................................ 6 3.1 GENERAL DESCRIPTION OF EUT ...................................................................................... 6 3.2 DESCRIPTION OF TEST MODES ........................................................................................ 7 3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS ..................................................... 10 3.4 DESCRIPTION OF SUPPORT UNITS ................................................................................ 10 3.5 CONFIGURATION OF SYSTEM UNDER TEST ................................................................. 10 3.6 DUTY CYCLE OF TESET SIGNAL ....................................................................................... 11 4. TEST TYPES AND RESULTS ...................................................................................................... 13 4.1 CONDUCTED EMISSION MEASUREMENT ...................................................................... 13 4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT ............................................... 13 4.1.2 TEST INSTRUMENTS ..................................................................................................... 13 4.1.3 TEST PROCEDURES ..................................................................................................... 14 4.1.4 DEVIATION FROM TEST STANDARD ........................................................................... 14 4.1.5 TEST SETUP ................................................................................................................... 15 4.1.6 EUT OPERATING CONDITIONS .................................................................................... 15 4.1.7 TEST RESULTS .............................................................................................................. 16 4.2 RADIATED EMISSION MEASUREMENT ........................................................................... 18 4.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT .................................................... 18 4.2.2 TEST INSTRUMENTS ..................................................................................................... 19 4.2.3 TEST PROCEDURES ..................................................................................................... 20 4.2.4 DEVIATION FROM TEST STANDARD ........................................................................... 20 4.2.5 TEST SETUP ................................................................................................................... 21 4.2.6 EUT OPERATIN…

Text truncated - open the document above for the full version.

Test Report

ANTENNASPECIFICATION Summary ITEMDongleANTSPEC ModelNamePCBANT Center Frequency 2403MHz2441MHz2480MHz 0.7206091.142091.1197 MAX.Gain1.14209 AzimuthBeam Pattern Omni-directional Impedance50Ohm AntennaLength14.4mm ManufacturesDONGGUANSHUOCHUANGELECTRONICSCOLTD ANTShapeSnakestructure AntennaPhoto&Length(mm) Total R e s p o n s e ( d B ) -16 2 -14 -12 -10 -8 -6 -4 -2 0 Y X Z Azimuth = -90.0 Elevation = 0.0 Roll = 0.0 Frequency (MHz) Gain(dBi) MaxMin 24030.720609-12.9412 24411.14209-11.7017 24801.1197-15.041

Contact Information

Applicant

Rick Ho(Manager, Regulatory Compliance)
[email protected]Fax: 886226973917

Technical Contact

Corsair Memory, Inc.Rick Ho
[email protected]

115 North McCarthy Blvd, · Milpitas, California, 95035 · United States

Test Firm

Bureau Veritas Shenzhen Co., Ltd. Dongguan BranchEdwin Ye
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz-
Confidentiality
Long Term

Other Applications from Corsair Memory, Inc.

2AAFM-RGP0193

Wireless Mouse

Sep 18, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
2AAFM-RDA0060

Dongle

May 19, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
2AAFM-RDA0059

Wireless Headset

May 19, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
2AAFM-RGP0179

Dongle

Mar 01, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
2AAFM-20LAM9901

Key Light Air MK.2

Feb 18, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX