FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. ACOUSTMAX INTERNATIONAL CO., LTD/
  3. 2AAIN-MNRR360

2AAIN-MNRR360ROCKIN ROLLER 360

ACOUSTMAX INTERNATIONAL CO., LTD
ROCKIN ROLLER 360 - FCC ID 2AAIN-MNRR360 - ACOUSTMAX INTERNATIONAL CO., LTD
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Nov 23, 2022
Application Purpose
Original Equipment
Date of Application
Nov 23, 2022
Equipment Note
ROCKIN ROLLER 360
Frequency Range
2402.00000000 - 2480.00000000
Company
ACOUSTMAX INTERNATIONAL CO., LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Operating ambient temperature: 0 - 40°C, Storage and transportation ambient temperature: -10 - 50°C, altitude not higher than 2000m (air pressure not less than 80kPa), WARNING: – replacement of a battery with an incorrect type may defeat a safeguard; – disposal of a battery into fire or a hot oven, or mechanically crushing or cutting of a battery, may result in an explosion; – leaving a battery in an extremely high temperature surrounding environment, such as sunshine, fire, or hot surface may result in an explosion or the leakage of flammable liquid or gas; – a battery subjected to extremely low air pressure may result in an explosion or the leakage of flammable liquid or gas. CAUTION Risk of fire or explosion if the battery is replaced by an incorrect type! Température ambiante de fonctionnement: 0-40 °C, Température ambiante de stockage et de transport: -10-50 °C, à une altitude ne dépassant pas 2000 m (pression atmosphérique ne dépassant pas 80 kPa), Avertissement: Remplacer une batterie de modèle incorrect peut compromettre les mesures de sécurité; Placer les batteries dans un four ou un four à haute température, ou écraser ou couper mécaniquement les batteries Les batteries, qui peuvent provoquer une explosion; Le fait de placer la batterie dans un environnement à très haute température, comme la lumière du soleil, le feu ou des surfaces chaudes, peut provoquer une explosion ou des fuites de liquides ou de gaz inflammables; Les batteries à très basse pression peuvent provoquer une explosion ou des fuites de liquides ou de gaz inflammables. Avertissements Risque d'incendie ou d'explosion si le mauvais type de batterie est remplacé!

External Photos

Page1of5FCCID:2AAIN-MNRR360IC:21776-MNRR360 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity ExternalPhotosoftheEUT Fig.1 Fig.2 Page2of5FCCID:2AAIN-MNRR360IC:21776-MNRR360 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of5FCCID:2AAIN-MNRR360IC:21776-MNRR360 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of5FCCID:2AAIN-MNRR360IC:21776-MNRR360 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Fig.8 Page5of5FCCID:2AAIN-MNRR360IC:21776-MNRR360 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.9

Internal Photos

Page1of11FCCID:2AAIN-MNRR360IC:21776-MNRR360 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity InternalPhotosoftheEUT Fig.1 Fig.2 Page2of11FCCID:2AAIN-MNRR360IC:21776-MNRR360 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of11FCCID:2AAIN-MNRR360IC:21776-MNRR360 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of11FCCID:2AAIN-MNRR360IC:21776-MNRR360 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Fig.8 Page5of11FCCID:2AAIN-MNRR360IC:21776-MNRR360 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.9 Fig.10 Page6of11FCCID:2AAIN-MNRR360IC:21776-MNRR360 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.11 Fig.12 BTAntenna BLEAntenna Page7of11FCCID:2AAIN-MNRR360IC:21776-MNRR360 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.13 Fig.14 Page8of11FCCID:2AAIN-MNRR360IC:21776-MNRR360 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.15 Fig.16 Page9of11FCCID:2AAIN-MNRR360IC:21776-MNRR360 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.17 Fig.18 CoilAntenna Page10of11FCCID:2AAIN-MNRR360IC:21776-MNRR360 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.19 Fig.20 Page11of11FCCID:2AAIN-MNRR360IC:21776-MNRR360 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.21 Fig.22

RF Exposure Info

Page1of4FCCID:2AAIN-MNRR360 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity MaximumPermissibleExposureReport 1.ProductInformation EUT:ROCKINROLLER360 TestModel:MNRR360 AdditionalModelNo.:MNRR360-X,MNRR360-C,MNRR360-EU,MNRR360Plus, MNRR360C,MNRR360X,MNRR360XC,MNRR360EU,MNRR360-X Plus,MNRR300,MNRR300-C,MNRR300-X,MNRR360PRO, MNRR360MAX ModelDeclaration:PCBboard,structureandinternalofthesemodel(s)arethesame,So noadditionalmodelsweretested PowerSupply:Input:AC100-240V,50/60Hz,100W USBOutput:DC5V,2.1A Battery:DC12V,9Ah HardwareVersion:/ SoftwareVersion:/ Bluetooth: FrequencyRange: 2402MHz~2480MHz ChannelNumber:79channelsforBluetoothV5.0(DSS) 40channelsforBluetoothV5.0(DTS) ChannelSpacing:1MHzforBluetoothV5.0(DSS) 2MHzforBluetoothV5.0(DTS) ModulationType:GFSK,Ď€/4-DQPSKforBluetoothV5.0(DSS) GFSKforBluetoothV5.0(DTS) BluetoothVersion:V5.0 AntennaDescription:BTAntenna:PCBAntenna,-0.58dBi(Max.) BLEAntenna:PCBAntenna,3.64dBi(Max.) Exposurecategory : Generalpopulation/uncontrolledenvironment EUTType:ProductionUnit DeviceType:MobileDevice Page2of4FCCID:2AAIN-MNRR360 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 2.EvaluationMethod SystemsoperatingundertheprovisionsofFCC47CFRsectionshallbeoperatedinamannerthatensuresthatthe publicisnotexposedtoradiofrequencyenergylevelinexcessoftheCommission’sguidelines. Inaccordancewith47CFRFCCPart2SubpartJ,section2.1091thisdevicehasbeendefinedasmobiledevice wherebyadistanceof0.2mnormallycanbemaintainedbetweentheuserandthedevice,andbelowRFPermissible Exposurelimitshallcomplywith. InaccordancewithKDB447498D01forSimultaneoustransmissionMPEtestexclusionapplieswhenthesumofthe MPEratiosforallsimultaneoustransmittingantennasincorporatedinahostdevice,basedonthe calculated/estimated,numericallymodelledormeasuredfieldstrengthsorpowerdensity,is≤1.0.TheMPEratioof eachantennaisdeterminedattheminimumtestseparationdistancerequiredbytheoperatingconfigurationsand exposureconditionsofthehostdevice,accordingtotheratiooffieldstrengthsorpowerdensitytoMPElimit,atthe testfrequency.Eitherthemaximumpeakorspatiallyaveragedresultsfrommeasurementsornumericalsimulations maybeusedtodeterminetheMPEratios.SpatialaveragingdoesnotapplywhenMPEisestimatedusingsimple calculationsbasedonfar-fieldplane-waveequivalentconditions.Theantennainstallationandoperating requirementsforthehostdevicemustmeettheminimumtestseparationdistancesrequiredbyallantennas,inboth standaloneandsimultaneoustransmissionoperations,tosatisfycompliance. 3.Limit 3.1ReferEvaluationMethod ANSIC95.1–2019:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoElectric,Magnetic,and ElectromagneticFields,0Hzto300GHz FCCKDBpublication447498D01General1RFExposureGuidancev06:MobileandPortableDevicesRFExposure ProceduresandEquipmentAuthorizationPolicies. FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1091:Radiofrequencyradiationexposureevaluation:mobiledevices. 3.2Limit LimitsforMaximumPermissibleExposure(MPE)/ControlledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100)* (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 LimitsforMaximumPermissibleExposure(MPE)/UncontrolledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/UncontrolledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100)* (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequencyinMHz *=Plane-waveequivalentpowerdensity Page3of4FCCID:2AAIN-MNRR360 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 4.MPECalculationMethod PredicationofMPElimitatagivendistance Equationfrompage18ofOETBulletin65,Edition97-01 S=PG/4Ď€R² Where:S=powerdensity P=powerinputtoantenna G=powergainoftheantennainthedirectionofinterestrelativetoanisotropicradiator R=distancetothecenterofradiationoftheantenna 5.AntennaInformation PCBAntennacanonlyuseantennascertificatedasfollowsprovidedbymanufacturer; Antennatypeand antennanumber Operatefrequency band Maximumantennagain Notes PCBAntenna2402MHz~2480MHz-0.58dBiBTAntenna PCBAntenna2402MHz~2480MHz3.64dBiBLEAntenna 6.ConductedPower [BT] ModeChannelFrequency(MHz) PeakConducted OutputPower(dBm) GFSK 024020.63 3924410.63 7824800.42 Ď€/4DQPSK 024020.28 3924410.26 7824800.18 [BLE] ModeChannelFrequency(MHz) PeakConducted OutputPower(dBm) BLE_1M 024020.18 1924400.07 392480-0.01 7.ManufacturingTolerance [BT] GFSK(Peak) ChannelChannel0Channel39Channel78 Target(dBm)000 Tolerance±(dB)1.01.01.0 Ď€/4DQPSK(Peak) ChannelChannel0Channel39Channel78 Target(dBm)000 Tolerance±(dB)1.01.01.0 [BLE] BTLE(Peak) ChannelChannel0Channel19Channel39 Target(dBm)000 Tolerance±(dB) 1.01.01.0 Page4of4FCCID:2AAIN-MNRR360 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 8.MeasurementResults 8.1StandaloneMPEEvaluation AsdeclaredbytheApplicant,theEUTisawirelessdeviceusedinafixapplication,atleast20cmfromanybodypart oftheuserornearbypersons;fromthemaximumEUTRFoutputpower,theminimumseparationdistance,r=20cm, aswellasthegainoftheusedantennarefe…

Text truncated - open the document above for the full version.

Test Report

Inverted F Antenna Specification Summary ITEMANT SPEC Model Name 2.4G ANT HorizontalVertical 2400MHz2500MHz 2450MHz 2500MHz2400MHz 2450MHz Center Frequency -1.86-2.46-5.25-0.58-0.76-1.26 MAX. Gain -0.58dBi PolarizationHorizontal and Vertical Azimuth Beam Pattern Omni-directional Impedance50 Ohm Antenna Length 38.20mm Manufacture ZHUHAI JIELI TECHNOLOGY CO.,LTD Antenna Photo & Length (mm) Horizontal: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -40 Scale: 5/div Frequency Gain(dBi) (MHz) Max Min Avg 2400 -1.26174 -30.0801 -7.18716 2450 -0.765802 -36.5604 -7.48023 2500 -0.585582 -22.0315 -6.59127 Vertical: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -30 Scale: 5/div Frequency Gain(dBi) (MHz) Max Min Avg 2400 -5.2537 -22.1424 -12.4294 2450 -2.4652 -24.5837 -10.4702 2500 -1.86120 -29.5214 -9.20432 ANT Test Labs:Attestation of Global Compliance Co., Ltd.

Test Report

Page 1 of 42FCC ID: 2AAIN-MNRR360IC: 21776-MNRR360 ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity AppendixA RF Test Data for BT (ConductedMeasurement) ProductName:ROCKINROLLER360 Test Model:MNRR360 EnvironmentalConditions Temperature: 23.5 ď‚° C RelativeHumidity:53.2% ATM Pressure:10 0.0 kPa Test Engineer:TaylorHu Supervisedby:Li Huan Page 2 of 42FCC ID: 2AAIN-MNRR360IC: 21776-MNRR360 ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity A.1 20dB EmissionBandwidth Test Result TestModeAntennaChannel 20db EBW[MHz] FL[MHz]FH[MHz]Verdict DH5Ant1 24020.9632401.5172402.480--- 24410.9482440.5172441.465--- 24801.0232479.4632480.486--- 2DH5Ant1 24021.2842401.3492402.633--- 24411.3502440.3132441.663--- 24801.2932479.3492480.642--- Page 3 of 42FCC ID: 2AAIN-MNRR360IC: 21776-MNRR360 ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity Test Graphs DH5_Ant1_2402 DH5_Ant1_2441 DH5_Ant1_2480 Page 4 of 42FCC ID: 2AAIN-MNRR360IC: 21776-MNRR360 ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity 2DH5_Ant1_2402 2DH5_Ant1_2441 Page 5 of 42FCC ID: 2AAIN-MNRR360IC: 21776-MNRR360 ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity 2DH5_Ant1_2480 Page 6 of 42FCC ID: 2AAIN-MNRR360IC: 21776-MNRR360 ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity A.2 OccupiedChannelBandwidth Test Result TestModeAntennaChannel OCB[MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict DH5Ant1 24020.897702401.53862402.4363------ 24410.897192440.53972441.4369------ 24800.898232479.53452480.4328------ 2DH5Ant1 24021.19252401.39202402.5845------ 24411.17602440.39612441.5721------ 24801.18272479.39342480.5761------ Page 7 of 42FCC ID: 2AAIN-MNRR360IC: 21776-MNRR360 ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity Test Graphs DH5_Ant1_2402 DH5_Ant1_2441 DH5_Ant1_2480 Page 8 of 42FCC ID: 2AAIN-MNRR360IC: 21776-MNRR360 ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity 2DH5_Ant1_2402 2DH5_Ant1_2441 Page 9 of 42FCC ID: 2AAIN-MNRR360IC: 21776-MNRR360 ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity 2DH5_Ant1_2480 Page 10 of 42FCC ID: 2AAIN-MNRR360IC: 21776-MNRR360 ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity A.3 Maximumconductedoutputpower Test Result TestModeAntenna Channe l Result[dBm] Limit [dBm] Antenna Gain (dBi) EIRP [dBm] EIRP Limit [dBm] Verdict DH5Ant1 24020.63≤30-0.580.05≤36PASS 24410.63≤30-0.580.05≤36PASS 24800.42≤30-0.58-0.16≤36PASS 2DH5Ant1 24020.28≤30-0.58-0.3≤36PASS 24410.26≤30-0.58-0.32≤36PASS 24800.18≤30-0.58-0.4 0≤36PASS Page 11 of 42FCC ID: 2AAIN-MNRR360IC: 21776-MNRR360 ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity Test Graphs DH5_Ant1_2402 DH5_Ant1_2441 DH5_Ant1_2480 Page 12 of 42FCC ID: 2AAIN-MNRR360IC: 21776-MNRR360 ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity 2DH5_Ant1_2402 2DH5_Ant1_2441 Page 13 of 42FCC ID: 2AAIN-MNRR360IC: 21776-MNRR360 ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity 2DH5_Ant1_2480 Page 14 of 42FCC ID: 2AAIN-MNRR360IC: 21776-MNRR360 ShenzhenLCS ComplianceTestingLaboratoryLtd. Add: 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 36 FCCID:2AAIN-MNRR360ReportNo.:LCSA092622177EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FOR ACOUSTMAXINTERNATIONALCO.,LTD ROCKINROLLER360 TestModel:MNRR360 AdditionalModelNo.:PleaseRefertoPage6 Preparedfor:ACOUSTMAXINTERNATIONALCO.,LTD Address: UnitD16/FCheukNangPlaza250HennessyRoad WanchaiHongKong.China Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address: 101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:October13,2022 Numberoftestedsamples:2 SampleNo. : A092622177-1,A092622177-2 Serialnumber:Prototype DateofTest:October13,2022~October26,2022 DateofReport:October27,2022 Page 2 of 36 FCCID:2AAIN-MNRR360ReportNo.:LCSA092622177EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FCCCFR47PART15C(15.247) ReportReferenceNo......................:LCSA092622177EA DateofIssue.......................................:October27,2022 TestingLaboratoryName..............:ShenzhenLCSComplianceTestingLaboratoryLtd. Address................................................: 101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China TestingLocation/Procedure............ : FullapplicationofHarmonisedstandardsâ–  PartialapplicationofHarmonisedstandardsâ–ˇ Otherstandardtestingmethodâ–ˇ Applicant’sName.............................: ACOUSTMAXINTERNATIONALCO.,LTD Address................................................: UnitD16/FCheukNangPlaza250HennessyRoad WanchaiHongKong.China TestSpecification Standard..............................................:FCCCFR47PART15C(15.247) TestReportFormNo.........................:LCSEMC-1.0 TRFOriginator....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceofthe material.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. TestItemDescription.....................:ROCKINROLLER360 TradeMark..........................................: TestModel...........................................:MNRR360 Ratings.................................................:Input:AC100-240V,50/60Hz,100W USBOutput:DC5V,2.1A Battery:DC12V,9Ah Result..................................................:Positive Compiledby:Supervisedby:Approvedby: KevinHuang/Administrator CaryLuo/Techniqueprincipal GavinLiang/Manager Page 3 of 36 FCCID:2AAIN-MNRR360ReportNo.:LCSA092622177EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCC--TESTREPORT TestResult Positive Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory. TestReportNo.:LCSA092622177EA October27,2022 Dateofissue TestModel.............................. : MNRR360 EUT......................................... : ROCKINROLLER360 Applicant...............................:ACOUSTMAXINTERNATIONALCO.,LTD Address...................................:UnitD16/FCheukNangPlaza250HennessyRoad WanchaiHongKong.China Telephone...............................:/ Fax..........................................:/ Manufacturer.........................:NINGBOPOLINATAELECTRONICSCO.,LTD. Address...................................:XinruiRoad#9,LongxingVillage,YinzhouDistrict, NINGBOCITY,Zhejiang315111 Telephone...............................:/ Fax..........................................:/ Factory...................................: NINGBOPOLINATAELECTRONICSCO.,LTD. Address...................................: XinruiRoad#9,LongxingVillage,YinzhouDistrict, NINGBOCITY,Zhejiang315111 Telephone...............................:/ Fax..........................................:/ Page 4 of 36 FCCID:2AAIN-MNRR360ReportNo.:LCSA092622177EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000October27,2022InitialIssue--- Page 5 of 36 FCCID:2AAIN-MNRR360ReportNo.:LCSA092622177EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TABLEOFCONTENTS DescriptionPage 1.GENERALINFORMATION................................................................................................................6 1.1DescriptionofDevice(EUT)........................................................................................................................6 1.2SupportequipmentList................................................................................................................................7 1.3ExternalI/OCable...................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Page1of2FCCID:2AAIN-MNRR360IC:21776-MNRR360 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestSetupPhotosoftheEUT TestSetupPhoto(s)ofRadiatedEmissionsMeasurement Fig.1 Fig.2 Page2of2FCCID:2AAIN-MNRR360IC:21776-MNRR360 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestSetupPhoto(s)ofConductedEmissionsMeasurement Fig.3

Contact Information

Applicant

Zhi yun Wu
[email protected]13510365603Fax: 852-25301919

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.20 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Other Applications from ACOUSTMAX INTERNATIONAL CO., LTD

MONSTER PARTYBOX 600 - FCC ID 2AAIN-MNPA-PB600 - ACOUSTMAX INTERNATIONAL CO., LTD
2AAIN-MNPA-PB600

MONSTER PARTYBOX 600

Jan 21, 2021

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
MONSTER MNPA-X82 - FCC ID 2AAIN-MNPAX82 - ACOUSTMAX INTERNATIONAL CO., LTD
2AAIN-MNPAX82

MONSTER MNPA-X82

Jan 21, 2021

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
MONSTER MNPA-X151 - FCC ID 2AAIN-MNPAX151 - ACOUSTMAX INTERNATIONAL CO., LTD
2AAIN-MNPAX151

MONSTER MNPA-X151

Jan 20, 2021

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
MONSTER SPARK - FCC ID 2AAIN-MNSPARK - ACOUSTMAX INTERNATIONAL CO., LTD
2AAIN-MNSPARK

MONSTER SPARK

Jan 20, 2021

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
MONSTER MNPA-X300 - FCC ID 2AAIN-MNPAX300 - ACOUSTMAX INTERNATIONAL CO., LTD
2AAIN-MNPAX300

MONSTER MNPA-X300

Jan 20, 2021

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter