
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
B ureau Veritas A7+ TouchCare® Insulin Management System User Guide © 2019, Medtrum Technologies Inc. All rights reserved. B ureau Veritas Humalog® is a trademark of Eli Lilly and Company. NovoRapid® is a trademark of Novo Nordisk A/S. Apidra® is a trademark of Sanofi S.A. Medtrum Technologies Inc. 7F, Building 8, No. 200, Niudun Road Shanghai 201203, China Tel: +86-21-50274781 Fax: +86-21-50274779 www.medtrum.com Medtrum B.V. Nijverheidsweg 17 5683 CJ Best The Netherlands Tel: +31 (0) 499745037 This product complies with Directive 93/42/EEC (MDD) and Directive 2014/53/EU (RED). REF SY-018 Version: 1.01 Publication date: 20 August, 2019 UG881116GB 348431 0197 B ureau Veritas i Contents Contents ........................................................................................ i 1 Introduction ............................................................................... 1 1.1 Before you begin .......................................................................... 1 1.2 Indications ................................................................................... 1 1.3 Contraindications ......................................................................... 2 1.4 User Safety ................................................................................... 2 1.4.1 Warnings and Precautions ............................................................ 2 1.4.2 Consumables ................................................................................. 5 1.4.3 Radio Frequency (RF) Communication .......................................... 6 1.4.4 Emergency Kit ............................................................................... 6 1.4.5 Water ............................................................................................ 7 1.4.6 Storage .......................................................................................... 7 1.4.7 FCC Caution ................................................................................... 8 1.4.8 IC Caution ...................................................................................... 9 1.5 Warranty Information ................................................................... 9 2 Your A7+ TouchCare® System ................................................... 15 2.1 Personal Diabetes Manager (PDM) ...............................................15 2.2 Patch Pump .................................................................................15 2.3 Glucose Sensing System (Optional) ..............................................16 3 How to use the PDM ................................................................. 19 3.1 Basics of the PDM ........................................................................19 3.1.1 Turn on/off the PDM ................................................................... 19 3.1.2 Charge the PDM .......................................................................... 20 3.1.3 Power Mode ................................................................................ 21 3.1.4 Scroll Bar ..................................................................................... 22 3.2 Setting up the PDM .....................................................................22 3.2.1 Select language and country/region ........................................... 22 B ureau Veritas ii 3.2.2 Time and Date ............................................................................. 23 3.2.3 Bolus Calculator ........................................................................... 24 3.3 Home Screen ............................................................................... 25 3.3.1 Status Bar Icons ........................................................................... 26 3.3.1.1 Battery Icon ..................................................................................... 26 3.3.1.2 Time Icon ........................................................................................ 26 3.3.1.3 Audio Icon ....................................................................................... 27 3.3.1.4 Pump RF Signal Icon ........................................................................ 27 3.3.1.5 Alert Icons ....................................................................................... 27 3.3.2 Pump Status ................................................................................ 28 3.3.3 Sensor Status ............................................................................... 29 3.3.4 EasyLoop Icon .............................................................................. 33 3.3.5 Sensor Graph ............................................................................... 34 3.3.6 Alarm Status ................................................................................ 35 3.4 Lock Screen ................................................................................. 36 3.5 Notification Screen ...................................................................... 37 3.6 Shortcut Screen ........................................................................... 37 3.7 Status Screen .............................................................................. 38 3.8 Menus ........................................................................................ 40 3.8.1 Bolus ............................................................................................ 40 3.8.2 Basal ............................................................................................ 40 3.8.3 Suspend ....................................................................................... 40 3.8.4 Patch ............................................................................................ 41 3.8.5 Sensor .......................................................................................... 41 3.8.6 History ......................................................................................... 41 3.8.7 Events ........................................…
Text truncated - open the document above for the full version.
135 2. Select a temp basal type, temp rate or percent and duration, then Tap Next to review the temporary basal rates set. Note: If Percent is selected, you can set the temp basal rate, not exceeding the Max Basal Rate, between 0 and 200% with an increment of 1%. If Rate (U/H) is selected, you can set the temp basal between 0 and the Max Basal Rate with an increment of 0.05 U/H. Note: You can set the duration between 30 min and 24h with an increment of 30 min. 3. Make sure that the temp basal is correct in this Temp Basal Review, then Slide to activate. 5.5.2 Cancel a Temp Basal 1. Go to the Cancel Temp Basal screen. Select Cancel Temp Basal. B ureau Veritas 136 Main Menu➔Basal➔Cancel Temp Basal 2. Slide to stop temp basal delivery, or tap to continue delivering. Note: If you suspend insulin delivery while a temp basal rate is active, the temp basal rate will be canceled. 5.6 Preset Temp Basal With the preset temp basal feature, you can program temp basal rates for recurring short-term situations. You can set up to seven preset temp basal rates: Heavy Ex, Medium Ex, Light Ex, Sick, Temp 1, and Temp 2 and Temp 3. 5.6.1 Preset Temp Basal Setup 1. Go to the Preset Temp Setup screen. B ureau Veritas 137 Main Menu➔Settings➔Insulin Pump➔Basal Setup➔Preset Temp Setup 2. Select a preset temp basal you want to edit. Choose the temp basal type (rate or percent). 3. Set the duration and rate/percentage of the preset temp basal. Tap Save to save settings. 5.6.2 Activate a Preset Temp Basal You must set up a preset temp basal before you can activate it. 1. Go to the Preset Temp Basal screen. Main Menu➔Basal➔Preset Temp Basal The programmed preset temp basal types are displayed on this screen. If you have not set up any preset temp basal rate, this screen shows No Presets. 2. Select the preset temp basal you want to activate. B ureau Veritas 138 3. Confirm your preset temp basal settings. 4. Slide to activate. 5.7 Reminder 5.7.1 Bolus Reminder When you fail to deliver a Bolus at between time point A and time point B, you will receive a Reminder at time point B. You can add, delete, or review Reminders when the Bolus Reminder option is turned on. Go to the Bolus Reminder screen. Main Menu➔Settings➔Reminders➔ Bolus Reminder Add Reminder Tap + Add time segment to add one Reminder, setting the start and end time. 1 2 1. Time Point A 2. Time Point B B ureau Veritas 139 Note: (1) The end time should be at least 30 min later than the start time. You can program up to four bolus Reminders. (2) The Reminders will be saved automatically. Delete Reminder Slide from right to left on one segment, tap Delete to delete this segment. 5.7.2 BG Reminder After you deliver a bolus, you may want to check your BG. The BG Reminder is an optional feature that reminds you to check your BG after a bolus. Go to the BG Reminder Setup screen. Main Menu ➔Settings➔Reminders➔BG Reminder B ureau Veritas 140 If you have BG Reminder turned on, the BG REMINDER DURATION screen appears when you set Bolus. It allows you to set the time before you are reminded to check your blood glucose after a bolus. The time ranges from 00:30 to 05:00 with an increment of 30 minutes. The default time is 00:30. You can also turn off the BG reminder after each bolus. You can accept or modify the time before you are reminded. 5.8 Pump History 5.8.1 Pump History The Pump History displays the delivery history (bolus, basal and total daily B ureau Veritas 141 delivery history) and alert history (pump alerts and alarms). Go to the Pump History screen. Main Menu➔History➔Pump History 5.8.1.1 Delivery History You can select one day to review its delivery graph. It displays the summary of basal, bolus and total delivery for one day. (1) The legend 1. Tap the date to switch between records of different dates 2. Tap the info icon to review legend meanings. 3. Tap the “Basal, Bolus, Total “summary chart at the bottom of Delivery History screen to see details. B ureau Veritas 142 Legend Abbreviation Significance Basal Basal Rate infusion curve Temp Basal Temp Basal Rate infusion curve Normal Bolus Normal Bolus delivery icon Extended Bolus Extended Bolus delivery icon Auto Suspend This tag appears when any of the following alarms occurs: AUTO OFF, PREDICTIVE LOW SUSPEND, LOW SUSPEND, EXCEEDS MAX TDD, EXCEEDS MAX 1HR DELIVERY ALARM. Manual Suspend Manually suspend all insulin delivery Stop Including deactivate patch, discard patch, and alarms: OCCLUSION DETECTED, PATCH EXPIRED, PATCH ERROR, PATCH BATT DEPLETED, PUMP BASE ERROR, EMPTY RESERVOIR. New Patch When you activate a new patch, this icon appears. (2) Basal History This screen displays most detailed Basal information. B ureau Veritas 143 (3) Bolus history The summary information includes: ⚫ The start time of this bolus; ⚫ Status of bolus: completed, canceled, delivering; ⚫ Bolus type; ⚫ Amount of bolus delivered |Amount of bolus programmed. Bolus Type: N: Normal Bolus E: Extended Bolus C: Combo Bolus Normal: Normal Bolus by Manual Bolus Extended: Extended Bolus by Manual Bolus B ureau Veritas 144 Combo: Combo Bolus by Manual Bolus Calc-N: Normal Bolus by Bolus Calculator Calc-E: Extended Bolus by Bolus Calculator Calc-C: Combo Bolus by Bolus Calculator Tap record line to view more detailed information. See Chapter “Advanced Pump Features” for more information. (4) Daily Totals This screen displays most detailed Daily Totals information. N represents Normal Bolus. E represents Extended Bolus. C represents Combo Bolus. FoodBolus 7.30U #1 means that there is one food bolus doses in the selected day with a total amount of 7.30U. CorrBolus 2.10U #1 means that there is one correction bolus doses in the selected day with a total amount of 2.10U. Food+Corr 0.00U #0 means that there is no bolus dose that both covers carbs and corrects glucose in the selected day. ManualBo 9.70U #2 means that there are two manual bolus doses in the selected day with a total amount of 9.70U. B ureau Veritas 145…
Text truncated - open the document above for the full version.
SCS-F18: Project and Product Certification Representative Authorization Letter Page 1 of 2 Rev 6.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Project and Product Certification Representative Authorization Letter Reason for Amendment (current / obsolete) Revision History Approved Date From To Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Revised wording (obsolete) 1.0 2.0 Sept–25-2007 Updated company template (obsolete) 2.0 3.0 Jan-31-2012 Updated letter information (obsolete) 3.0 4.0 May-23-2014 Added FCC ID field (obsolete) 4.0 5.0 Sep-16-2014 Updated company name & logo (current) 5.0 6.0 Jun-27-2018 SCS-F18: Project and Product Certification Representative Authorization Letter Page 2 of 2 Rev 6.0 MEDTRUM TECHNOLOGIES Inc. (2020/01/03) To: BVCPS, INC. 775 Montague Expressway, Milpitas, CA 95035 USA Dear Sir/Madam, Re: Project and Product Certification Representative Authorization Letter We, MEDTRUM TECHNOLOGIES Inc. hereby authorize Bureau Veritas Consumer Product Services, Inc. to act as a Certification Body for certifying for the following project(s): FCC ID: 2AARU-JN022 Product Description: Pump Base Model: JN-022 We affirm that between Bureau Veritas Consumer Product Services, Inc. and ____ MEDTRUM TECHNOLOGIES Inc ___, any difference in understanding, including test plan, measurement methods, applicable standards and relevant procedures and processes have been resolved prior to commencement of testing activities. Sincerely, Client’s signature: Client’s name / title: Sherry He Contact information / address : 7F, Buiding 8, 200 Niudun Rd Shanghai
SCS-F19: Confidentiality Request Letter Page 1 of 2 Rev 6.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Confidentiality Request Letter Reason for Amendment (current / obsolete) Revision History Approved Date From To Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Adding CFR 2.459 (obsolete) 1.0 2.0 August – 11 - 2008 Updated company template & Added text box (obsolete) 2.0 3.0 Jan-31-2012 Added IC confidentiality letter form (obsolete) 3.0 4.0 March-26-2015 Corrections to STC form. Added reference to KDB (obsolete) 4.0 5.0 Nov-19-2015 Updated company logo (current) 5.0 6.0 Jun-26-2019 SCS-F19: Confidentiality Request Letter Page 2 of 2 Rev 6.0 MEDTRUM TECHNOLOGIES Inc. (2020/01/03) To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Subject: Permanent Confidentiality Request for FCC ID: 2AARU-JN022 Pursuant to sections 0.457 and 0.459 of CFR 47, we respectfully request permanent confidential treatment of the following Exhibits accompanying this application as: - Block Diagram - Schematics - Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Client’s signature: Client’s name / title: Sherry He Contact information / address : 7F, Buiding 8, 200 Niudun Rd Shanghai
Test Report No. Q191022S005 Page 1 of 4 Photographs OF THE EUT EUT External Photo Test Report No. Q191022S005 Page 2 of 4 Test Report No. Q191022S005 Page 3 of 4 Test Report No. Q191022S005 Page 4 of 4
APPROVAL VIEW DIRECTION Unit DD YY Material CHECK Scale M REVISION M COPY& USE FOR ANY PURPOSE NEED WRITTEN PERMISSION FROM SHANGHAI MEDTRUM D Y FINISH DESIGN DESCRIPTION Q'TY DRAW M DAT E D ALL DIMENSIONS IN mm; DON'T SCALE THIS DRAWING Y PART NAME MODEL M FILE NO DESIGNCHECKAPPROVAL 10-50 50-100 100- ANGLE ±0.15 ±0.25% ±0.25 ±0.2% ±0.15% 5-10 ±0.05 ±0.15 ±0.1 0-5 ±0.02 A ±0.1 ±0.2 ±0.15 ±0.2 ±0.05 B ±0.1 C 0-30° 31°-60° 61°-90° D ±0.3° ±0.5° ±0.1° VER. SYMBOL DESCRIPTION DATE VER. 1.00 2018.04.08 1.01 2019.04.29 SN XXXXXXXXX TouchCare JN-022 REF FCC ID:2AARU-JN022 0197 label location
Test Report No. Q191022S005 Page 1 of 2 Photographs OF THE EUT EUT Internal Photo Test Report No. Q191022S005 Page 2 of 2 Antenna
RF EXPOSURE REPORT Report No.: Q191022S005-FCC-H Supersede Report No.: N/A Applicant Medtrum Technologies Inc Product Name Pump Base Model No. JN-022 Serial No. N/A Test Standard FCC 2.1093 Test Date Nov. 19 to Dec. 25, 2019 Issue Date Jan. 20, 2020 Test Result Pass Fail Equipment complied with the specification Equipment did not comply with the specification Aaron Liang Test Engineer David Huang Checked By This test report may be reproduced in full only Test result presented in this test report is applicable to the tested sample only Issued by: BUREAU VERITAS (SHENZHEN) CONSUMER PRODUCTS SERVICE CO., LTD Zone A, Floor 1, Building 2 Wan Ye Long Technology Park South Side of Zhoushi Road, Bao’an District, Shenzhen, Guangdong China 518108 Phone: +86 0755 2601 4629801 Email: [email protected] Test Report No. Q191022S005-FCC-H Page 2 of 8 Laboratories Introduction SIEMIC, headquartered in the heart of Silicon Valley, with superior facilities in US and Asia, is one of the leading independent testing and certification facilities providing customers with one-stop shop services for Compliance Testing and Global Certifications. In addition to testing and certification, SIEMIC provides initial design reviews and compliance management throughout a project. Our extensive experience with China, Asia Pacific, North America, European, and International compliance requirements, assures the fastest, most cost effective way to attain regulatory compliance for the global markets. Accreditations for Conformity Assessment Country/Region Scope USA EMC, RF/Wireless, SAR, Telecom Canada EMC, RF/Wireless, SAR, Telecom Taiwan EMC, RF, Telecom, SAR, Safety Hong Kong RF/Wireless, SAR, Telecom Australia EMC, RF, Telecom, SAR, Safety Korea EMI, EMS, RF, SAR, Telecom, Safety Japan EMI, RF/Wireless, SAR, Telecom Singapore EMC, RF, SAR, Telecom Europe EMC, RF, SAR, Telecom, Safety Test Report No. Q191022S005-FCC-H Page 3 of 8 This page has been left blank intentionally. Test Report No. Q191022S005-FCC-H Page 4 of 8 CONTENTS 1. REPORT REVISION HISTORY ............................................................................................................................ 5 2. CUSTOMER INFORMATION ................................................................................................................................ 5 3. TEST SITE INFORMATION ................................................................................................................................... 5 4. EQUIPMENT UNDER TEST (EUT) INFORMATION ......................................................................................... 6 5. FCC §2.1093 - RADIOFREQUENCY RADIATION EXPOSURE EVALUATION: PORTABLE DEVICES. 7 5.1 RF EXPOSURE .......................................................................................................................................................... 7 5.2 TEST RESULT ........................................................................................................................................................... 8 Test Report No. Q191022S005-FCC-H Page 5 of 8 1. Report Revision History Report No. Report Version Description Issue Date Q191022S005-FCC-H NONE Original Jan. 20, 2020 2. Customer information Applicant Name Medtrum Technologies Inc Applicant Add 7F, Building 8, No.200 Niudun Road, Shanghai 201203, China Manufacturer Medtrum Technologies Inc Manufacturer Add 7F, Building 8, No.200 Niudun Road, Shanghai 201203, China 3. Test site information Lab performing tests BUREAU VERITAS (SHENZHEN) CONSUMER PRODUCTS SERVICE CO., LTD Lab Address Zone A, Floor 1, Building 2 Wan Ye Long Technology Park South Side of Zhoushi Road, Bao’an District, Shenzhen, Guangdong China 518108 FCC Test Site No. 535293 IC Test Site No. 4842E-1 Test Software EZ-EMC(ver.Icp-03A1) Test Report No. Q191022S005-FCC-H Page 6 of 8 4. Equipment under Test (EUT) Information Description of EUT: Pump Base Main Model: JN-022 Serial Model: N/A Date EUT received: Nov. 18, 2019 Test Date(s): Nov. 19 to Dec. 25, 2019 Antenna Gain: BLE: 1.6dBi Antenna Type: Ceramic antenna Type of Modulation: BLE: GFSK RF Operating Frequency (ies): BLE: 2402-2480 MHz Number of Channels: BLE: 40CH Port: Please refer to user’s manual Input Power: Battery: DC 3.7V Trade Name : Medtrum FCC ID: 2AARU- Mark: The Product is a BLE device, that can connect via BLE to either a smartphone or a HUB to transfer the button clicks upon pushed. JN022 Test Report No. Q191022S005-FCC-H Page 7 of 8 DFP/ 5. FCC §2.1093 - Radiofrequency radiation exposure evaluation: portable devices. 5.1 RF Exposure Standard Requirement: According to §15.247 (i) and §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. Routine SAR evaluation refers to that specifically required by § 2.1093, using measurements or computer simulation. When routine SAR evaluation is not required, portable transmitters with output power greater than the applicable low threshold require SAR evaluation to qualify for TCB approval. result = P= Maximum turn-up power in mW F= Channel frequency in GHz D= Minimum test separation distance in mm Test Report No. Q191022S005-FCC-H Page 8 of 8 5.2 Test Result BLE Mode: Modulation CH Freq (MHz) Conducted Power (dBm) Tune Up Power (dBm) Max Tune Up Power (dBm) Max Tune Up Power (mW) Result Limit GFSK Low 2402 -0.54 -0.5±1 0.5 1.122 0.348 3 Mid 2440 -0.27 -0.5±1 0.5 1.122 0.351 3 High 2480 -0.64 -0.5±1 0.5 1.122 0.353 3 Result: Compliance No SAR measurement is required.
Test Report No. Q191022S005-FCC-R Page 1 of 34 RF TEST REPORT Report No.: Q191022S005-FCC-R Supersede Report No.: N/A Applicant Medtrum Technologies Inc. Product Name Pump Base Main Model No. JN-022 Serial Model No. N/A Test Standard FCC Part 15.247, ANSI C63.10: 2013 Test Date Nov. 19 to Dec. 25, 2019 Issue Date Dec. 26, 2019 Test Result Pass Fail Equipment complied with the specification Equipment did not comply with the specification Aaron Liang Test Engineer David Huang Checked By This test report may be reproduced in full only Test result presented in this test report is applicable to the tested sample only Issued by: BUREAU VERITAS (SHENZHEN) CONSUMER PRODUCTS SERVICE CO., LTD Zone A, Floor 1, Building 2 Wan Ye Long Technology Park South Side of Zhoushi Road, Bao’an District, Shenzhen, Guangdong China 518108 Phone: +86 0755 2601 4629801 Email: [email protected] Test Report No. Q191022S005-FCC-R Page 2 of 34 Laboratories Introduction SIEMIC, headquartered in the heart of Silicon Valley, with superior facilities in US and Asia, is one of the leading independent testing and certification facilities providing customers with one-stop shop services for Compliance Testing and Global Certifications. In addition to testing and certification, SIEMIC provides initial design reviews and compliance management throughout a project. Our extensive experience with China, Asia Pacific, North America, European, and International compliance requirements, assures the fastest, most cost effective way to attain regulatory compliance for the global markets. Accreditations for Conformity Assessment Country/Region Scope USA EMC, RF/Wireless, SAR, Telecom Canada EMC, RF/Wireless, SAR, Telecom Taiwan EMC, RF, Telecom, SAR, Safety Hong Kong RF/Wireless, SAR, Telecom Australia EMC, RF, Telecom, SAR, Safety Korea EMI, EMS, RF, SAR, Telecom, Safety Japan EMI, RF/Wireless, SAR, Telecom Singapore EMC, RF, SAR, Telecom Europe EMC, RF, SAR, Telecom, Safety Test Report No. Q191022S005-FCC-R Page 3 of 34 This page has been left blank intentionally. Test Report No. Q191022S005-FCC-R Page 4 of 34 CONTENTS 1. REPORT REVISION HISTORY ............................................................................................................................ 5 2. CUSTOMER INFORMATION ................................................................................................................................ 5 3. TEST SITE INFORMATION ................................................................................................................................... 5 4. EQUIPMENT UNDER TEST (EUT) INFORMATION ......................................................................................... 6 5. TEST SUMMARY .................................................................................................................................................... 7 6. MEASUREMENTS, EXAMINATION AND DERIVED RESULTS ..................................................................... 8 6.1 ANTENNA REQUIREMENT ..................................................................................................................................... 8 6.2 DTS (6 DB&20 DB) CHANNEL BANDWIDTH ....................................................................................................... 9 6.3 MAXIMUM OUTPUT POWER ............................................................................................................................... 12 6.4 POWER SPECTRAL DENSITY ............................................................................................................................. 15 6.5 BAND-EDGE & UNWANTED EMISSIONS INTO NON-RESTRICTED FREQUENCY BANDS .................. 17 6.6 AC POWER LINE CONDUCTED EMISSIONS ................................................................................................... 20 6.7 RADIATED SPURIOUS EMISSIONS ................................................................................................................... 22 ANNEX A. TEST INSTRUMENT ................................................................................................................................. 29 ANNEX B. TEST SETUP AND SUPPORTING EQUIPMENT ................................................................................ 30 ANNEX C. USER MANUAL / BLOCK DIAGRAM / SCHEMATICS / PARTLIST .................................................. 33 ANNEX D. DECLARATION OF SIMILARITY ............................................................................................................. 34 Test Report No. Q191022S005-FCC-R Page 5 of 34 1. Report Revision History Report No. Report Version Description Issue Date Q191022S005-FCC-R NONE Original Dec. 26, 2019 2. Customer information Applicant Name Medtrum Technologies Inc. Applicant Add 7F, Building 8, No.200 Niudun Road, Shanghai 201203, China Manufacturer Medtrum Technologies Inc. Manufacturer Add 7F, Building 8, No.200 Niudun Road, Shanghai 201203, China 3. Test site information Test Lab A: Lab performing tests BUREAU VERITAS (SHENZHEN) CONSUMER PRODUCTS SERVICE CO., LTD Lab Address Zone A, Floor 1, Building 2 Wan Ye Long Technology Park South Side of Zhoushi Road, Bao’an District, Shenzhen, Guangdong China 518108 FCC Test Site No. 535293 IC Test Site No. 4842E-1 Test Software Radiated Emission Program-To Shenzhen v2.0 Test Report No. Q191022S005-FCC-R Page 6 of 34 4. Equipment under Test (EUT) Information Description of EUT: Pump Base Main Model: JN-022 Serial Model: N/A Date EUT received: Nov. 18, 2019 Test Date(s): Nov. 19 to Dec. 25, 2019 Equipment Category: DTS Antenna Gain: 1.6dBi Antenna Type: Ceramic antenna Type of Modulation: GFSK RF Operating Frequency (ies): 2402-2480 MHz Max. Output Power: -0.64 dBm Number of Channels: BLE:40CH Port: Please refer to the user manual Input Power: Battery: Model: L1154F Spec: 3V Trade Name : Medtrum FCC ID: 2AARU- JN022 Test Report No. Q191022S005-FCC-R Page 7 of 34 5. Test Summary The product was tested in accordanc…
Text truncated - open the document above for the full version.
Test Report No. Q191022S005-CE-E Page 1 of 1 Photograph: Test Setup Photo Radiated Emission-Below 1 GHz Radiated Emission-Above 1 GHz
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.00 mW |

Transmitter
Equipment Class
DTS - Digital Transmission System
Transmitter
Equipment Class
DTS - Digital Transmission System
Pump Base
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Wireless USB stick
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver