Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Clinic BPC B-101 Short Manual; Version 1.0 / 29.08.2013 Kontron Europe GmbH Clinic-BPC B-101 - User’s Manual (V1.0) 1 Table of Contents 1. Introduction .................................................................................................................................................................... 2 1.1. Symbols used in this Manual ........................................................................................................................................ 3 2. Important Instructions .................................................................................................................................................. 4 2.1. Note on the Warranty ................................................................................................................................................... 4 2.2. Exclusion of Accident Liability Obligation ..................................................................................................................... 4 2.3. Liability Limitation / Exemption from the Warranty Obligation ...................................................................................... 4 3. Safety Instructions ........................................................................................................................................................ 5 3.1. Electrostatic Discharge (ESD) ...................................................................................................................................... 5 3.2. Grounding Methods ...................................................................................................................................................... 5 4. Product Description ...................................................................................................................................................... 6 4.1. Front Side View ............................................................................................................................................................ 6 4.2. Rear Side View ............................................................................................................................................................. 7 4.3. Mechanical Specifications ............................................................................................................................................ 8 4.4. Installed Singleboard .................................................................................................................................................... 9 4.5. Installed AC Power Supply Unit .................................................................................................................................... 9 4.6. Accessing Internal Components ................................................................................................................................... 9 4.7. EMC .............................................................................................................................................................................. 9 Clinic-BPC B-101 - User’s Manual (V1.0) 2 1. Introduction Kontron Europe would like to point out that the information contained in this manual may be subject to technical changes, particularly as a result of continuous product upgrades. The attached documentation does not entail any guarantee on the part of Kontron Europe with respect to technical processes described in the manual or any product characteristics set out in the manual. Kontron Europe does not accept any liability for any printing errors or other inaccuracies in the manual unless it can be proven that Kontron Europe is aware of such errors or inaccuracies or that Kontron Europe is unaware of these as a result of gross negligence and Kontron Europe has failed to eliminate these errors or inaccuracies for this reason. Kontron Europe expressly informs the user that this manual only contains a general description of technical processes and instructions which may not be applicable in every individual case. In cases of doubt, please contact Kontron Europe. This manual is protected by copyright. All rights are reserved by Kontron Europe. Copies of all or part of this manual or translations into a different language may only be made with the prior written consent of Kontron Europe. Kontron Europe points out that the information contained in this manual is continuously being updated in line with the technical alterations and improvements made by Kontron Europe to the products and thus this manual only reflects the technical status of the products by Kontron Europe at the time of printing. © 2012 by Kontron Europe Printing and duplication, even of sections, is only permissible with the express approval of Kontron Europe GmbH Sudetenstraße 7 87600 Kaufbeuren Germany Clinic-BPC B-101 - User’s Manual (V1.0) 3 1.1. Symbols used in this Manual Symbol Meaning This symbol indicates the danger of injury to the user or the risk of damage to the product if the corresponding warning notices are not observed. This symbol indicates that the product or parts thereof may be damaged if the corresponding warning notices are not observed. This symbol indicates detail information about the specific product configuration. This symbol indicates ESD Handling information. ® Microsoft, MS-DOS, Windows 98, Windows 2000, Windows CE.net, Windows XP are registered trademarks of the Microsoft Corporation in the United States and other countries. ® IBM, PC-AT and PS/2 are registered trademarks of the International Business Machines Corporation. ® Intel and Pentium are registered trademarks of the Intel Corporation. ® LINUX is a registered trademark and exclusively licensed by Linus Torvalds Other product names mentioned in this manual may also be registered trademarks and are used solely for identification purposes. Clinic-BPC B-101 - User’s Manual (V1.0) 4 2. Important Instructions This chapter contains instructions …
Text truncated - open the document above for the full version.
FCC ID: 2AATHCLINIC-BPCB101 Applicant: Kontron Europe GmbH Photo documentation of the EuT (external photos) 1.1 FCC ID: 2AATHCLINIC-BPCB101 Applicant: Kontron Europe GmbH
FCC ID: 2AATHCLINIC-BPCB101 Applicant: Kontron Europe GmbH Photo documentation of the EuT (internal photos) 1.1 FCC ID: 2AATHCLINIC-BPCB101 Applicant: Kontron Europe GmbH FCC ID: 2AATHCLINIC-BPCB101 Applicant: Kontron Europe GmbH FCC ID: 2AATHCLINIC-BPCB101 Applicant: Kontron Europe GmbH FCC ID: 2AATHCLINIC-BPCB101 Applicant: Kontron Europe GmbH FCC ID: 2AATHCLINIC-BPCB101 Applicant: Kontron Europe GmbH
The pulse of innovation » Clinic-BPC B-101 « Medical Box PC Patient Information at a Glimpse » IT workstation: interface for IEC60601-1 certifi ed devices » 2 independent external monitor outputs (DVI) » 3x LAN, medical isolated » PSU AC/DC medical built-in » Silent operation, fanless design www.kontron.com Kontron Datasheet 2 Asia Pacifi c 17 Building,Block #1, ABP. 188 Southern West 4th Ring Road Beijing 100070, P.R.China Tel.: + 86 10 63751188 Fax: + 86 10 83682438 [email protected] CORPORATE OFFICES Europe, Middle East & Africa Oskar-von-Miller-Str. 1 85386 Eching / Munich Germany Tel.: + 49 8165 77 777 Fax: + 49 8165 77 219 [email protected] North America 14118 Stowe Drive Poway, CA 92064-7147 USA Tel.: + 1 888 294 4558 Fax: + 1 858 677 0898 [email protected] Datasheet – Medical Box PC #08272013WMH All data is for information purposes only and not guaranteed for legal purposes. Subject to change without notice. Information in this datasheet has been carefully checked and is believed to be accurate; however, no responsibilty is assumed for inaccurancies. All brand or product names are trademarks or r egistered trademarks of their respective owners. Product Line Clinic-BPC Processors 3rd Generation Mobile Intel® Core™ i5-3610ME dual core or i7-3612QE quad core (others on request) Chipset/PCH Intel® QM77 Graphics Intel® HD 4000 Memory Max. 8 GB DDR3 RAM Interfaces 1x LAN 10/100/1000 with medical reinforced isolation 2x LAN 10/100 (via switch) with medical reinforced isolation 4x USB 3.0 2x DVI (DVI-I + DVI-D) Stereo audio: line in/out, mic., speaker optional 3x RS232 RJ45 medical isolated or optional 2x RS232 Dsub9 + PCIe/mSATA MiniCard Storage drives 2.5" SATA III SSD/HDD, optional mSATA Expansions PCIe x1, SATA II, USB 2.0, TTL (on proprietary expansion header for optional I/O) Power 110-240VAC, 50/60Hz (medical) Dimension (H x W x D) 305 x 360 x 79 mm Weight 4.5 kg Mounting Wall Mount VESA 75 / 100 (I/Os down) Chassis Plastic Housing Cooling Fanless (vertical usage) Temperature Operating: 0°C to +35°C Storage: -20°C to +60°C Humidity Operating: 15 to 95 % @ 40°C not condensing Storage: 5 to 95 % @ 40°C not condensing Approvals CE, cULus listed, CB Certifi cate acc. IEC60950-1, IEC60601-1 isolated circuits and touch current approved Altitude 0-3000m MTBF ~ 50.000 h Verified OS Windows 7 Ultimate or WES7 Technical Information Clinic-BPC B-101 Medical Box PC - Patient Information at a Glimpse
Test Report E-0504-4901-05 RM Type / Model Name: KONTRON Clinic-BPC B-101 Medical PC System Product Description: Kontron Europe GmbH Applicant: File No. E-0504-4901-05 RM emitel GmbH, Ohmstrasse 1, 94342 STRASSKIRCHEN, DEUTSCHLAND Tel. / Phone: +49 (0) 94 24 94 82-0 Fax: +49 (0) 94 24 94 82-640 emG_F510_01_Rev9_0 Freigabedatum / Date of release: 2012-02-07; Autor / Author: Martin Stern Seite / Page 2 von / of 30 EMC -- T E S T R E P O R T Test Report No. : E-0504-4901-05 RM 2013-08-14 ______________________________________________________________________________________________ Date of issue Type / Model Name : KONTRON Clinic-BPC B-101 Medical PC System Product Description : Kontron Europe GmbH Applicant : Sudetenstraße 7 Address : 87600 Kaufbeuren Germany Kontron Europe GmbH Manufacturer : Sudetenstraße 7 Address : 87600 Kaufbeuren Germany Test Result according to the standards listed in clause 1 test standards: POSITIVE The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permission of the test laboratory. File No. E-0504-4901-05 RM emitel GmbH, Ohmstrasse 1, 94342 STRASSKIRCHEN, DEUTSCHLAND Tel. / Phone: +49 (0) 94 24 94 82-0 Fax: +49 (0) 94 24 94 82-640 emG_F510_01_Rev9_0 Freigabedatum / Date of release: 2012-02-07; Autor / Author: Martin Stern Seite / Page 3 von / of 30 Contents 1 T E S T S T A N D A R D S 4 2 O V E R V I E W T E S T R E S U L T 4 3 S U M M A R Y 5 4 E Q U I P M E N T U N D E R T E S T 6 4.1 PHOTO DOCUMENTATION OF THE EUT 6 4.2 POWER SUPPLY SYSTEM 13 4.3 SHORT DESCRIPTION OF THE EQUIPMENT UNDER TEST (EUT) 13 5 T E S T E N V I R O N M E N T 15 5.1 ADDRESS OF THE TEST LABORATORY 15 5.2 STATEMENT REGARDING THE USAGE OF LOGOS AT TEST REPORTS 15 5.3 ENVIRONMENTAL CONDITIONS 15 5.4 STATEMENT OF THE MEASUREMENT UNCERTAINTY 15 6 T E S T C O N D I T I O N S A N D R E S U L T S 18 6.1 CONDUCTED DISTURBANCE 18 6.2 RADIATED DISTURBANCE (ELECTRIC FIELD) 23 6.3 RADIATED DISTURBANCE ( 1 TO 16GHZ) 26 7 U S E D T E S T E Q U I P M E N T A N D A C C E S S O R I E S 30 File No. E-0504-4901-05 RM emitel GmbH, Ohmstrasse 1, 94342 STRASSKIRCHEN, DEUTSCHLAND Tel. / Phone: +49 (0) 94 24 94 82-0 Fax: +49 (0) 94 24 94 82-640 emG_F510_01_Rev9_0 Freigabedatum / Date of release: 2012-02-07; Autor / Author: Martin Stern Seite / Page 4 von / of 30 1 T E S T S T A N D A R D S The tests were performed according to following standards: FCC Part 15 Subpart A Code of Regulations Part 15 (Radio Frequency Devices), Subpart A October 2010 (General) of the Federal Communications Commision (FCC) FCC Part 15 Subpart B Code of Regulations Part 15 (Radio Frequency Devices), Subpart B October 2010 (Unintentional Radiators) of the Federal Communications Commision (FCC) Class A Class B Applied Paragraphs: §15.107, §15.109 ANSI C63.4-2003 American National Standard for Methods of Measurement of Radio- Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9kHz – 40 GHz 2 O V E R V I E W T E S T R E S U L T Performed test(s) Result Passed Failed Not performed Conducted disturbance X Radiated disturbance (electric field) X Radiated disturbance ( 1 to 16GHz) X File No. E-0504-4901-05 RM emitel GmbH, Ohmstrasse 1, 94342 STRASSKIRCHEN, DEUTSCHLAND Tel. / Phone: +49 (0) 94 24 94 82-0 Fax: +49 (0) 94 24 94 82-640 emG_F510_01_Rev9_0 Freigabedatum / Date of release: 2012-02-07; Autor / Author: Martin Stern Seite / Page 5 von / of 30 3 S U M M A R Y GENERAL REMARKS: The EUT was grounded via medical potential equalization plug during all tests. The test settings for the Burn in test were carried out by the applicant. According to the applicants declaration the device is sold in two different names. FINAL ASSESSMENT: The equipment under test fulfills the EMC requirements cited in clause 1 test standards. Date of receipt of test sample : acc. to storage records Testing commenced on : 2013-06-10 Testing concluded on : 2013-06-23 Checked by: Tested by: Wolfgang Straubinger Manager EMC Group Michael Raith Test Engineer File No. E-0504-4901-05 RM emitel GmbH, Ohmstrasse 1, 94342 STRASSKIRCHEN, DEUTSCHLAND Tel. / Phone: +49 (0) 94 24 94 82-0 Fax: +49 (0) 94 24 94 82-640 emG_F510_01_Rev9_0 Freigabedatum / Date of release: 2012-02-07; Autor / Author: Martin Stern Seite / Page 6 von / of 30 4 E Q U I P M E N T U N D E R T E S T 4.1 Photo documentation of the EuT EUT File No. E-0504-4901-05 RM emitel GmbH, Ohmstrasse 1, 94342 STRASSKIRCHEN, DEUTSCHLAND Tel. / Phone: +49 (0) 94 24 94 82-0 Fax: +49 (0) 94 24 94 82-640 emG_F510_01_Rev9_0 Freigabedatum / Date of release: 2012-02-07; Autor / Author: Martin Stern Seite / Page 7 von / of 30 EUT Lable File No. E-0504-4901-05 RM emitel GmbH, Ohmstrasse 1, 94342 STRASSKIRCHEN, DEUTSCHLAND Tel. / Phone: +49 (0) 94 24 94 82-0 Fax: +49 (0) 94 24 94 82-640 emG_F510_01_Rev9_0 Freigabedatum / Date of release: 2012-02-07; Autor / Author: Martin Stern Seite / Page 8 von / of 30 Periphery: Keyboard Mouse File No. E-0504-4901-05 RM emitel GmbH, Ohmstrasse 1, 94342 STRASSKIRCHEN, DEUTSCHLAND Tel. / Phone: +49 (0) 94 24 94 82-0 Fax: +49 (0) 94 24 94 82-640 emG_F510_01_Rev9_0 Freigabedatum / Date of release: 2012-02-07; Autor / Author: Martin Stern Seite / Page 9 von / of 30 Headset LCD TFT Monitor (1) File No. E-0504-4901-05 RM emitel GmbH, Ohmstrasse 1, 94342 STRASSKIRCHEN, DEUTSCHLAND Tel. / Phone: +49 (0) 94 24 94 82-0 Fax: +49 (0) 94 24 94 82-640 emG_F510_01_Rev9_0 Freigabedatum / Date of release: 2012-02-07; Autor / Author: Martin Stern Seite / Page 10 von / of 30 LCD TFT Monitor (2) SAM Image Master (Server 1) File No. E-0504-4901-05 RM emitel GmbH, Ohmstrasse 1, 94342 STRASSKIRCHEN, DEUTSCHLAND Tel. / Phone: +49 (0) 94 24 94 82-0 Fax: +49 (0) 94 24 94 82-640 emG_F510_01_Rev9_0 Freigabedatum / Date of release: 2012-02-07; Autor / Author: Martin Stern Seite / Page 11 von / of 30 New SAM Assembly without OA2.1 (Server 2) Solid-state drives (SSD’s) from EUT File No. E-0504-4901-05 RM emitel Gmb…
Text truncated - open the document above for the full version.
FCC ID: 2AATHCLINIC-BPCB101 Applicant: Kontron Europe GmbH Photo documentation of the Test setup 1.1 conducted disturbance 150kHz – 30MHz radiated disturbance 30MHz – 1GHz FCC ID: 2AATHCLINIC-BPCB101 Applicant: Kontron Europe GmbH radiated disturbance 1GHz – 16GHz
Sudetenstrasse 7 · Kaufbeuren · Germany
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | - | - |