FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Etekcity Corporation/
  3. 2AB22-ESB591

2AB22-ESB591Smart Body Weight Scale

Etekcity Corporation
Smart Body Weight Scale - FCC ID 2AB22-ESB591 - Etekcity Corporation
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 12, 2021
Application Purpose
Original Equipment
Date of Application
Jul 12, 2021
Equipment Note
Smart Body Weight Scale
Frequency Range
2402.00000000 - 2480.00000000
Company
Etekcity Corporation
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 Smart Body Weight Scale Model: ESB-591 User Manual Questions or Concerns? (855) 686-3835 • [email protected] 2 Table of Contents Package Contents Specifications Safety Information Function Diagram Display Diagram Before First Use VeSync App Setup Using the Smart Scale Maintenance Common Display Codes Troubleshooting FCC Statement Warranty Information Customer Support 3 3 4 6 7 8 9 12 14 16 17 20 21 23 3 1 x Smart Body Weight Scale 3 x 1.5V AAA Batteries (Pre-Installed) 1 x Quick Start Guide Specifications Package Contents Weight Capacity400 lb / 28 st / 180 kg Increments0.1 lb / 0.05 kg Weight Unitslb / st / kg PlatformTempered Glass Battery3 x 1.5V AAA Batteries (Pre-Installed) Auto-Off15 s e c o n ds Dimensions11 x 11 x 0.9 in / 280 x 280 x 23 mm Operating SystemiOS ® 9.0+ or Android™ 5.0+ 4 Safety Information • This scale should not be used to diagnose or treat any medical condition. • Scale data should not be used as a substitute for medical advice from a healthcare professional. • Check the scale before using. Do not use the scale if it is damaged in any way. • Do not strike or hit the scale. Do not use the scale if the glass is cracked or broken. While tempered glass is stronger and fractures more safely than ordinary glass, it may shatter unexpectedly after developing a slight crack. If you see a crack, contact Customer Support immediately (page 23). • The glass platform is slippery when wet. Always make sure the platform and your feet are dry before stepping on for measurement. • Place the scale on a hard, flat surface to avoid tipping. Please read and follow all instructions and safety guidelines in this manual. Medical General Use READ AND SAVE THESE INSTRUCTIONS 5 • Do not mix new and old batteries. • If the scale is not in use for a long period of time, remove the batteries to extend the lifetime of the scale. Batteries • To weigh safely and accurately, stand with your feet shoulder- width apart while on the scale. Do not stand on the edge of the scale or jump on the scale. • Avoid standing on the scale for a long period of time, or when you are not weighing yourself. • Do not overload the scale. Maximum weight capacity is 400 lb / 28 st / 180 kg. • Keep the scale in a cool area with low humidity. Keep the scale away from heat sources, such as ovens or heaters. Avoid temperature fluctuations. Store the scale in a horizontal position, not vertical. • Handle with care. Not for commercial use. Household use only. 6 Function Diagram A. Weighing Platform B. Display C. Anti-Skid Padding D. Battery Compartment CDAB 7 Display Diagram A. Weight Measurement B. Bluetooth ® Icon C. Weight Units A B C 8 Before First Use 1. Open the battery compartment on the underside of the scale. Remove the included AAA batteries. 2. Remove the plastic insulator strip from the battery compartment. 3. Replace the batteries. Follow the guidelines in the battery compartment to match the + and – terminals. Push and Lift 1.5V - AAA 1.5V - AAA 1.5V - AAA 9 VeSync App Setup 1. To download the VeSync app, scan the QR code or search “VeSync” in the Apple App Store ® or Google Play Store. Note: Due to app updates and improvements, the VeSync app may be slightly different than shown in the manual. In case of any differences, follow the in-app instructions. Note: • This scale uses the VeSync app, not the VeSyncFit app. • For Android users, you may need to select “Allow” to use VeSync. 10 2. Open the VeSync app. If you already have an account, tap Log In. To create a new account, tap Sign Up. Note: You must create your own VeSync account to use third-party services and products. These will not work with a guest account. With a VeSync account, you can also allow your family and friends to use your smart body weight scale. Note: You can change the name and icon at any time in the smart body weight scale settings. 3. Make sure the scale is fully charged. 4. Make sure your phone has Bluetooth turned on. 5. Ta p + in the VeSync app and select your smart body weight scale. 6. Follow the in-app instructions to connect to your smart body weight scale. 11 Creating a User If you are a new user, you will need to enter physical information before weighing yourself for the first time so the scale can calculate your body metrics. Follow the in-app instructions to create a user profile. Note: • Entering inaccurate information will make the scale’s measurements less accurate. • If you don’t identify with the available gender options, or are unsure, pick the option that you think best physically matches you. While this scale’s measurements do not take gender into account, your choice may be used for physical measurements, depending on which smart scales you use with the VeSync app. 12 Using the Smart Scale Note: • To change the scale’s weight unit, download the VeSync app and select the desired weight unit in the Device Settings menu. • To see your BMI measurement, you must connect the scale to the VeSync app (see page 9). • If you are pregnant, scale measurements will not be accurate. 1. Place the scale on a hard, flat surface (not a carpet or mat). [Figure 1.1] Note: Placing on soft surfaces such as carpet may cause inaccurate measurements or tipping. [Figure 1.1] 13 2. Make sure your feet are dry. Step onto the scale. The scale will automatically turn on and start measuring your weight. 3. Continue standing on the scale until the digits on the display flash 3 times, showing your final measurement. [Figure 1.2] If your smart scale is connected to the VeSync app, your results (weight and BMI) will show in the app. 4. If you want to measure the weight of your baby or pet, you can click the “ ”(Expand) button in the lower right corner of the home page and click the “ ”(Baby Mode) button to enter the baby measurement mode and measure according to the prompts. In baby mode, the APP will only measure weight and BMI. [Figure 1.2] 14 Maintenance Calibrating the Smart Scale If the scale has been moved or flipped upside down, it must b…

Text truncated - open the document above for the full version.

Cover Letter(s)

EtekcityCorporation Date:June11,2021 TO: FederalCommunicationCommission EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MID21046 Regarding:FCCID:2AB22-ESB591 Towhomitmayconcern: We,theundersigned,herebyauthorizeSGS-CSTCStandardsTechnicalServicesCo.,Ltd.(SGS)ShenzhenBranch andKenyXuinSGS-CSTCStandardsTechnicalServicesCo.,Ltd.(SGS)ShenzhenBranchtoactonourbehalfinall mannersrelatingtoapplicationforequipmentauthorizationwithrespecttotheFCCIDabove,includingsigningof alldocumentsrelatingtothesematters.Anyandallactscarriedoutbytheagentonourbehalfshallhavethesame effectasactsofourown. We,theundersigned,herebycertifythatwearenotsubjecttoadenialoffederalbenefits,thatincludesFCC benefits,pursuanttoSection5301oftheAnti-DrugAbuseActof1988,21U.S.C.853(a). Whereouragentsignstheapplicationforcertificationonourbehalf,Iacknowledgethatallresponsibilityfor complyingwiththetermsandconditionsforCertification,asspecifiedbySGSNorthAmerica,Inc.,stillresideswith EtekcityCorporation. Thisauthorizationisvaliduntilfurtherwrittennoticefromtheapplicant. PrintName:ChrisHuangTitle:Manager,Productcompliance Signature: OnbehalfofCompany:EtekcityCorporation Telephone:86-755-23215504 E-mail:[email protected]

Cover Letter(s)

ArovastCorporation TO: FederalCommunicationCommission EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MID21046 Regarding: ConfidentialityRequestregardingapplicationforFCCID:2AB22-ESB591 LONGTERMCONFIDENTIALITY Pursuantto47CFRSection0.459and0.457ofthecommission’srules,theapplicantherebyrequestconfidential treatmentofthedocumentslistedbelow,associatedwiththecertificationapplicationreferencedabove. Schematic(s) BlockDiagrams OperationalDescriptions Thedocumentsabovecontainproprietaryinformationnotreleasedtothepublic.Publicdisclosureofthis informationmayproveharmfultothebusinessoftheapplicant. SHORT TERM CONFIDENTIALITY Additionally, the applicant requests the following documents be held confidential until the device is marketed or 180 days from the grant date, whichever is less. If the device is marketed within 180 days of the Grant Date, the applicant will notify the TCB per FCC KDB 726920 D01 Confidentiality Request Procedures. External Photos Internal Photos Test Setup Photos User manual(s) Sincerely, PrintName:ChrisHuangTitle: Manager,Productcompliance Signature: OnbehalfofCompany:EtekcityCorporation Telephone:86-755-23215504 E-mail:[email protected]

Cover Letter(s)

ApplicantDeclaration ApplicantDeclaration Rev:0.0 SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia 30024 United States Applicant Legal Business Name Etekcity Corporation Address 1202 N Miller St Suite A,ANAHEIM,California 92806,United States Grantee Code 2AB22 FCC ID 2AB22-ESB591 Authorized Contact Name Chris Huang Contact Email [email protected] Contact Phone 86-755-23215504 I, the undersigned, certify that I am an authorized signatory for the Applicant and therefore declare; a) in accordance with 47CFR2.911(d), all of the statements herein and the exhibits attached hereto are true and correct to the best of my knowledge and belief. b) in accepting a Grant of Equipment Authorization issued by a TCB, under the authority of the FCC, as a result of the representations made in this application, the Applicant is responsible for: (1) labeling the equipment with the exact FCC ID as specified in this application, (2) compliance statement labeling pursuant to the applicable rules, (3) compliance of the equipment with the applicable technical rules, c) if the Applicant is not the actual manufacturer of the equipment, appropriate arrangements have been made with the manufacturer to ensure that production units of this equipment will continue to comply with the FCC’s technical requirements. d) in accordance with 47 CFR 2.909 and KDB394321, the Applicant has read, understood and agrees to accept that they are the responsible party and agree to abide by their responsibilities as specified under 47 CFR 2.909 and KDB394321. e) in accordance with ISO17065, FCC KDB641163, FCC KDB610077, KDB394321 and RSP-100, the Applicant has read, understood, accepts and agrees to abide by the post market surveillance requirements. (1) the Applicant understands, accepts and agrees that a sample may be requested for surveillance testing. (2) the Applicantshallmake provisions to always have a production sample available upon request by SGS, FCC and/or ISED. (3) the Applicantshall, upon request by SGS, at the Applicant’s expense, provide a production sample of the requested product to SGS, FCC and/or ISED as instructed. The sample shall include all support devices, cables, software, accessories or other hardware or software required for evaluation, review, certification and audit surveillance of products certified by SGS. f) neither the Applicant nor any party to the application is subject to a denial of Federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. §862 because of a conviction for possession or distribution of a controlled substance. See 47CFR 1.2002(b) for the definition of a “party” for these purposes. g) the Applicant has read, understood, accepts and agrees to abide by the SGS North America, Inc.(TCB) terms and conditions. Link to CFRs:https://www.fcc.gov/wireless/bureau-divisions/technologies-systems-and-innovation-division/rules-regulations-title-47 Link to KDBs:https://apps.fcc.gov/oetcf/kdb/index.cfm Link to RSP-100:https://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01130.html Applicant Signature: Date: June 11, 2021 PrintName:ChrisHuang Title:Manager, Product compliance *NOTE: This declaration cannot be signed by an Agent, it shall be signed by an authorized person listed in the FCC database

External Photos

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 4 External Photos for SZCR2106021503AT FCC ID: 2AB22-ESB591 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 4 1 EUT Constructional Details SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 4 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 4 of 4

ID Label/Location Info

The product label will be screen printed on the bottom of the product.

Internal Photos

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 3 Internal Photos for SZCR2106021503AT FCC ID: 2AB22-ESB591 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 3 1 EUT Constructional Details SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 3 Antenna

RF Exposure Info

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZCR210602150303 Page: 1 of 6 Keny Xu EMC Laboratory Manager 1 Cover page SAR Evaluation Report Application No.: SZCR2106021503AT Applicant: Etekcity Corporation Address of Applicant: 1202 N Miller St Suite A, ANAHEIM, California, 92806 United States Manufacturer: Etekcity Corporation Address of Manufacturer: 1202 N. Miller St. Suite A, Anaheim, CA 92806, USA Factory: Zhongshan Camry Electronic Co., Ltd Address of Factory: Baishawan Industrial Park, Qiwan Road, East District, Zhongshan, Guangdong, China Equipment Under Test (EUT): EUT Name: Smart Body Weight Scale Model No.: ESB-591 Trade mark: Etekcity FCC ID: 2AB22-ESB591 Standards: 47 CFR Part 1.1307 47 CFR Part 2.1093 KDB447498D01 General RF Exposure Guidance v06 Date of Receipt: 2021-06-15 Date of Test: 2021-06-15 to 2021-06-23 Date of Issue: 2021-06-30 Test Result : PASS* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZCR210602150303 Page: 2 of 6 2 Version Revision Record Version Chapter Date Modifier Remark 01 2021-06-30 Original Authorized for issue by: Benson Wang/Project Engineer Eric Fu/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZCR210602150303 Page: 3 of 6 3 Contents Page 1 COVER PAGE ........................................................................................................................................ 1 2 VERSION ................................................................................................................................................ 2 3 CONTENTS ............................................................................................................................................ 3 4 GENERAL INFORMATION ..................................................................................................................... 4 4.1 GENERAL DESCRIPTION OF EUT ......................................................................................................... 4 4.2 TEST LOCATION ................................................................................................................................ 5 4.3 TEST FACILITY .................................................................................................................................. 5 4.4 DEVIATION FROM STANDARDS ............................................................................................................ 5 4.5 ABNORMALITIES FROM STANDARD CONDITIONS .................................................................................... 5 4.6 OTHER INFORMATION REQUESTED BY THE CUSTOMER .......................................................................... 5 5 SAR EVALUATION ................................................................................................................................. 6 5.1 RF EXPOSURE COMPLIANCE REQUIREMENT ........................................................................................ 6 5.1.1 Standard Requirement ................................................................................................................ 6 5.1.2 Limits .......................................................................................................................................... 6 5.1.3 EUT RF Exposure ....................................................................................................................... 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZCR210602150303 Page: 4 of 6 4 General Information 4.1 General Description of EUT Power supply: 4.5VDC(1.5V×3"AAA" Size Batteries) Operation Frequency: 2402MHz to 2480MHz Bluetooth Version: V4.2 LE Modulation Type: GFSK Number of Channels: 40 Channel Spacing: 2MHz Antenna Type: Integral Antenna Antenna Gain: 1dBi SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZCR210602150303 Page: 5 of 6 4.2 Test Location All tests were performed at: SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong, China 518057 Telephone: +86 (0) 755 2601 2053 Fax: +86 (0) 755 2671 0594 No tests were sub-contracted. 4.3 Test Facility The test facility is recognized, certified, or accredited by the following organizations: • A2LA (Certificate No. 3816.01) SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01. • VCCI The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz, Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have been registered in accordance with the Regulations for Voluntary Control Measures with Registration No.: G-20026, R-14188, C-12383 and T-11153 respectively. • FCC –Designation Number: CN1178 SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized as an accredited testing laboratory. Designation Number: CN1178. Test Firm Registration Number: 406779. • Innovation, Science and Economic Development Canada SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized by ISED as an accredited testing laboratory. CAB identifier: CN0006. IC#: 4620C. 4.4 Deviation from Standards None. 4.5 Abnormalities from Standard Conditions None. 4.6 Other Information Requested by the Customer None. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZCR210602150303 Page: 6 of 6 5 SAR Evaluation 5.1 RF Exposure Compliance Requirement 5.1.1 Standard Requirement According to KDB447498D01 General RF Exposure Guidance v06 4.3.1. Standalone SAR test exclusion considerations Unless spec…

Text truncated - open the document above for the full version.

Test Report

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZCR210602150302 Page: 1 of 56 Keny Xu EMC Laboratory Manager TEST REPORT Application No.: SZCR2106021503AT Applicant: Etekcity Corporation Address of Applicant: 1202 N Miller St Suite A, ANAHEIM, California, 92806 United States Manufacturer: Etekcity Corporation Address of Manufacturer: 1202 N. Miller St. Suite A, Anaheim, CA 92806, USA Factory: Zhongshan Camry Electronic Co., Ltd Address of Factory: Baishawan Industrial Park, Qiwan Road, East District, Zhongshan, Guangdong, China Equipment Under Test (EUT): EUT Name: Smart Body Weight Scale Model No.: ESB-591 Trade Mark: Etekcity FCC ID: 2AB22-ESB591 Standard(s) : 47 CFR Part 15, Subpart C 15.247 Date of Receipt: 2021-06-15 Date of Test: 2021-06-15 to 2021-06-23 Date of Issue: 2021-06-30 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZCR210602150302 Page: 2 of 56 Revision Record Version Chapter Date Modifier Remark 01 2021-06-30 Original Authorized for issue by: Benson Wang/Project Engineer Eric Fu/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZCR210602150302 Page: 3 of 56 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C 15.247 N/A 47 CFR Part 15, Subpart C 15.203 & 15.247(b)(4) Pass Radio Spectrum Matter Part Item Standard Method Requirement Result Conducted Peak Output Power 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.9.1 47 CFR Part 15, Subpart C 15.247(b)(3) Pass Minimum 6dB Bandwidth ANSI C63.10 (2013) Section 11.8.1 47 CFR Part 15, Subpart C 15.247a(2) Pass Power Spectrum Density ANSI C63.10 (2013) Section 11.10.2 47 CFR Part 15, Subpart C 15.247(e) Pass Conducted Band Edges Measurement ANSI C63.10 (2013) Section 11.13.3.2 47 CFR Part 15, Subpart C 15.247(d) Pass Conducted Spurious Emissions ANSI C63.10 (2013) Section 11.11 47 CFR Part 15, Subpart C 15.247(d) Pass Radiated Emissions which fall in the restricted bands ANSI C63.10 (2013) Section 6.10.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Below 1GHz ANSI C63.10 (2013) Section 6.4,6.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Above 1GHz ANSI C63.10 (2013) Section 6.6 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZCR210602150302 Page: 4 of 56 3 Contents Page 1 COVER PAGE ..................................................................................................................................... 1 2 TEST SUMMARY ................................................................................................................................. 3 3 CONTENTS ......................................................................................................................................... 4 4 GENERAL INFORMATION .................................................................................................................. 6 4.1 DETAILS OF E.U.T. ......................................................................................................................... 6 4.2 DESCRIPTION OF SUPPORT UNITS .................................................................................................... 6 4.3 MEASUREMENT UNCERTAINTY ......................................................................................................... 6 4.4 TEST LOCATION ............................................................................................................................. 7 4.5 TEST FACILITY ............................................................................................................................... 7 4.6 DEVIATION FROM STANDARDS ......................................................................................................... 7 4.7 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................. 7 5 EQUIPMENT LIST ............................................................................................................................... 8 6 RADIO SPECTRUM TECHNICAL REQUIREMENT ............................................................................11 6.1 ANTENNA REQUIREMENT ................................................................................................................11 6.1.1 Test Requirement: ..................................................................................................................11 6.1.2 Conclusion ..............................................................................................................................11 7 RADIO SPECTRUM MATTER TEST RESULTS .................................................................................12 7.1 CONDUCTED PEAK OUTPUT POWER ................................................................................................12 7.1.1 E.U.T. Operation .....................................................................................................................12 7.1.2 Test Mode Description ............................................................................................................12 7.1.3 Test Setup Diagram ................................................................................................................13 7.1.4 Measurement Procedure and Data .........................................................................................13 7.2 MINIMUM 6DB BANDWIDTH .............................................................................................................14 7.2.1 E.U.T. Operation .....................................................................................................................14 7.2.2 Test Mode Description ..............................…

Text truncated - open the document above for the full version.

Test Setup Photos

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 2 Setup Photos for SZCR2106021503AT FCC ID: 2AB22-ESB591 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 2 1 Photographs Radiated Spurious Emissions Below 1GHz Radiated Spurious Emissions Above 1GHz

Contact Information

Applicant

Wayne Pan
[email protected]18988680784Fax: N/A

Technical Contact

SGS-CSTC Standards Technical Services Co., Ltd.Keny Xu
[email protected]86-755-25328629

No.1 Workshop, M-10, Middle Section, · Shenzhen · China

Non-Technical Contact

SGS-CSTC Standards Technical Services Co., Ltd.Keny Xu
[email protected]86-755-25328629

Test Firm

SGS-CSTC Standards Technical Services Co., LtdDerek Yang
[email protected]+86 0135 6484 8721

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz800.00 µW
Confidentiality
Long Term
Grant Notes
Output Power listed is conducted.

Other Applications from Etekcity Corporation

2AB22-LDHH251S

Dehumidifier

Aug 18, 2026

Equipment Class

DTS - Digital Transmission System
2AB22-EFSA791

Smart Fitness Scale

Jun 15, 2026

Equipment Class

DTS - Digital Transmission System
Levoit Windi Lift Pro - FCC ID 2AB22-F461S - Vesync (US) Corporation
2AB22-F461S

Levoit Windi Lift Pro

May 15, 2026

Equipment Class

DTS - Digital Transmission System
2AB22-LAPP501S

Vital Pet Pro Air Purifier

Jan 30, 2026

Equipment Class

DTS - Digital Transmission System
Smart Fitness Scale with BLE - FCC ID 2AB22-EFSC671 - Etekcity Corporation
2AB22-EFSC671

Smart Fitness Scale with BLE

Mar 04, 2025

Equipment Class

DTS - Digital Transmission System