2AB2MPECGT-IIIVPocketECG Monitor

Medicalgorithmics S.A.
PocketECG Monitor - FCC ID 2AB2MPECGT-IIIV - Medicalgorithmics S.A.
Click to zoom

Application Details

Equipment Class
PCB - PCS Licensed Transmitter
Date of Grant
Aug 18, 2015
Application Purpose
Original Equipment
Date of Application
Aug 18, 2015
Equipment Note
PocketECG Monitor
Frequency Range
1851.25000000 - 1908.75000000
Company
Medicalgorithmics S.A.
Country
Poland

Documents & Files

Select a file to view

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

RF Exposure Info

↗
↗
↗
↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

ID Label/Location Info

Label Artwork Label Location

RF Exposure Info

This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. 731 Enterprise Drive Lexington, KY 40510 Telephone: 859-226-1000 Facsimile: 859-226-1040 www.intertek-etlsemko.com TEST REPORT Report Number: 102083831LEX-003 Project Number: G102083831 Evaluation of Model Number: PocketECG III, type PECGT-IIIV Tested to the SAR Criteria in FCC Part 2.1093 per KDB 447498 IC RSS-102 Issue 5 For Medicalgorithmics SA Test Performed by: Test Authorized by: Intertek 731 Enterprise Drive Lexington, KY 40510 Medicalgorithmics SA Al. Jerozolimskie 81 02-001 Warszawa, Poland Prepared By:_______________________________Date:_______________ Jason Centers, Staff Engineer Approved By:______________________________Date:________________ Bryan Taylor, Team Leader 5/20/2015 5/20/2015 731 Enterprise Drive, Lexington KY 40510 Evaluation For:Medicalgorithmics SA Model Number: PocketECG III, type PECGT-IIIV Report Number: 102083831LEX-003 Page 2 of 37 TABLE OF CONTENTS 1.0 DOCUMENT HISTORY ................................................................................................................ 4 2.0 INTRODUCTION ............................................................................................................................ 5 M ODIFICATIONS MADE TO TEST SAMPLE .................................................................................................. 5 3.0 TEST SITE DESCRIPTION ........................................................................................................... 6 MEASUREMENT EQUIPMENT ..................................................................................................................... 7 MEASUREMENT UNCERTAINTY ................................................................................................................ 8 4.0 JOB DESCRIPTION ..................................................................................................................... 10 5.0 SYSTEM VERIFICATION .......................................................................................................... 11 S YSTEM VALIDATION.............................................................................................................................. 11 TISSUE SIMULATING LIQUID DESCRIPTION AND VALIDATION ............................................................... 12 6.0 EVALUATION PROCEDURES .................................................................................................. 14 TEST POSITIONS: ..................................................................................................................................... 14 REFERENCE POWER MEASUREMENT: ..................................................................................................... 14 AREA SCAN: ............................................................................................................................................ 14 Z OOM SCAN: ........................................................................................................................................... 14 I NTERPOLATION, EXTRAPOLATION AND DETECTION OF MAXIMA: ........................................................ 16 P OWER DRIFT MEASUREMENT: .............................................................................................................. 17 RF AMBIENT ACTIVITY:.......................................................................................................................... 17 7.0 CRITERIA ...................................................................................................................................... 18 8.0 TEST CONFIGURATION ............................................................................................................ 18 9.0 TEST RESULTS ............................................................................................................................ 20 C ONDUCTED OUTPUT POWER MEASUREMENTS: .................................................................................... 20 SIMULTANEOUS TRANSMISSION CALCULATIONS: .................................................................................. 21 SAR TEST EXCLUSIONS: ......................................................................................................................... 21 10.0 REFERENCES ........................................................................................................................... 22 11.0 APPENDIX – WORST CASE SAR PLOTS ............................................................................ 23 12.0 APPENDIX – DIPOLE VALIDATION PLOTS ..................................................................... 31 13.0 APPENDIX – DESCRIPTION OF THE PHANTOMS USED FOR TESTING .................. 35 14.0 APPENDIX – SYSTEM VALIDATION SUMMARY ............................................................ 37 731 Enterprise Drive, Lexington KY 40510 Evaluation For:Medicalgorithmics SA Model Number: PocketECG III, type PECGT-IIIV Report Number: 102083831LEX-003 Page 3 of 37 731 Enterprise Drive, Lexington KY 40510 Evaluation For:Medicalgorithmics SA Model Number: PocketECG III, type PECGT-IIIV Report Number: 1…

Text truncated - open the document above for the full version.

RF Exposure Info

731 Enterprise Drive, Lexington KY 40510 Evaluation For:Medicalgorithmics SA Model Number: PocketECG III Report Number: 102083831LEX-003 Page 18 of 31 Figure 3: Front Test Position

Test Report

This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. EMC Report for Medicalgorithmics SA on the PocketECG III, type PECGT-IIIV Page 1 of 37 731 Enterprise Drive Lexington, KY 40510 Telephone: 859-226-1000 Facsimile: 859-226-1040 www.intertek-etlsemko.com TEST REPORT Report Number: 102083831LEX-002 Project Number: G102083831 Report Issue Date: 5/29/2015 Product Name: PocketECG III, type PECGT-IIIV FCC Standards: Title 47 CFR Part 22 and 24, RSS- 132 Issue 3, RSS-133 Issue 6 Tested by: Client: Intertek Testing Services NA, Inc. 731 Enterprise Drive Lexington, KY 40510 Medicalgorithmics SA Al. Jerozolimskie 81 02-001 Warszawa, Poland Report prepared by Report reviewed by Bryan Taylor, Team Leader Jason Centers, Staff Engineer Intertek Report Number: 102083831LEX-002 Issued: 5/29/2015 EMC Report for Medicalgorithmics SA on the PocketECG III, type PECGT-IIIV Page 2 of 37 TABLE OF CONTENTS 1 Introduction and Conclusion .............................................................................................................. 3 2 Test Summary ...................................................................................................................................... 3 3 Description of Equipment Under Test ............................................................................................... 4 4 Conducted Output Power.................................................................................................................... 6 5 Occupied Bandwidth ......................................................................................................................... 13 6 Conducted Spurious Emissions at Antenna Terminals ................................................................. 20 7 Radiated Output Power ..................................................................................................................... 27 8 Radiated Spurious Emissions (Transmitter) ................................................................................... 28 9 Frequency Stability ............................................................................................................................ 32 10 Measurement Uncertainty.............................................................................................................. 36 11 Revision History ............................................................................................................................. 37 Intertek Report Number: 102083831LEX-002 Issued: 5/29/2015 EMC Report for Medicalgorithmics SA on the PocketECG III, type PECGT-IIIV Page 3 of 37 1 Introduction and Conclusion The tests indicated in Section 2 were performed on the product constructed as described in Section 3. The remaining test sections are the verbatim text from the actual data sheets used during the investigation. These test sections include the test name, the specified test method, a list of the actual test equipment used, documentation photos, results and raw data. No additions, deviations, or exclusions have been made from the standard(s) unless specifically noted. Based on the results of our investigation, we have concluded the product tested complied with the requirements of the standard(s) indicated. The results obtained in this test report pertain only to the item(s) tested. The INTERTEK-Lexington laboratory is located at 731 Enterprise Drive, Lexington Kentucky, 40510. The radiated emission test site is a 10-meter semi-anechoic chamber. The chamber meets the characteristics of CISPR 16-1 and ANSI C63.4. For measurements, a remotely controlled flush-mount metal-top turntable is used to rotate the EUT a full 360 degrees. A remote controlled non-conductive antenna mast is used to scan the antenna height from one to four meters. The test site is listed with the FCC under Registration Number 485103. 2 Test Summary Page Test full name FCC Reference Industry Canada Result 6 Conducted Output Power §2.1046 §24.232(d) RSS-132 (4.4), RSS-133 (4.1), RSS-133 (6.4) Pass 13 Occupied Bandwidth §2.1049, §22.917(b)(d), and §24.238(a) RSS-GEN (4.6.1), RSS-133 (2.3) Pass 20 Conducted Spurious Emissions §2.1049, §2.1051, §22.917(a)(b), and § 24.238(a)(b) RSS-132 (4.5), RSS-133 (6.5.1) Pass 27 Radiated Output Power § 22.913(a) and § 24.232(c) RSS-132 (4.4), RSS-133 (6.4) Pass 28 Radiated Spurious Emissions (Transmitter) §2.1053, §22.917(a)(b), and §24.238(a)(b) RSS-132 (4.5), RSS-133 (6.5) Pass 32 Frequency Stability §2.1055, §22.355, and §24.235 RSS-132 (4.3), RSS-133 (6.3) Pass Intertek Report Number: 102083831LEX-002 Issued: 5/29/2015 EMC Report for Medicalgorithmics SA on the PocketECG III, type PECGT-IIIV Page 4 of 37 3 Description of Equipment Under Test Equipment Under Test Manufacturer Medicalgorithmics SA Model Number PocketECG III, type PECGT-IIIV Serial Number Test Sample 1 Receive Date 4/21/2015 Test Start Date 5/12/2015 Test End Date 5/18/2015 Device Received Condition Good Test Sample Type Production Frequency Band 824MHz - 849MHz (CDMA Cell Band) 1850MHz – 1910MHz (CDMA PCS Band) Modulation Type CDMA Transmission Control Base Station Simulator Maximum Output Power (Conduct…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Joanna Dabala(Product Compliance Leader)
[email protected]+48733888448Fax: +48222928368

Technical Contact

Medicalgorithmics S.A.Maciej Kulesza
+48 502 896 546

Aleje Jerozolimskie 81 · Warsaw, Mazowieckie · Poland

Non-Technical Contact

Medicalgorithmics S.A.Przemyslaw Tadla
[email protected]+48 733 888 778

Test Firm

Intertek Testing Services NAJames Sudduth
[email protected]859-226-1037Fax: 859 226 1040

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
224E1.85 GHz - 1.91 GHz296.00 mW1M32F9W2.5 ppm
Confidentiality
Long Term
Grant Notes
The output power listed is ERP for Part 22 and EIRP for Part 24. This device must not be co-located or operating in conjunction with any other antenna or transmitter. This device has been tested for SAR compliance for body-worn configurations. SAR compliance for body-worn operating configurations must be restricted to body-worn accessories that maintain the device a minimum of 10 mm from the body and have no metallic component in the assembly. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR value is 0.79 W/kg. This device contains functions that are not operational in the U.S. Territories. This filing is only applicable for U.S. operations.

Other Applications from Medicalgorithmics S.A.

PocketECG IV transmitter - FCC ID 2AB2MP4TRAA - Medicalgorithmics S.A.
2AB2MP4TRAA

PocketECG IV transmitter

Aug 03, 2020

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
Pocket ECG Monitor - FCC ID 2AB2MPECGT-III - Medicalgorithmics S.A.
2AB2MPECGT-III

Pocket ECG Monitor

Oct 30, 2014

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter