Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
... a step ahead in monitoring structures and natural hazards by ellegi srl 9 8 7 6 12 June 2014 Revision minor changes CR IB DL 5 21 May 2014 Revision minor changes DL CR CR 4 16 May 2014 Revision DL CR CR 3 10 April 2014 Revision IB DL CR 2 01 July 2013 Revision CR CR DL 1 01 December 2010 Revision IB DL CR 0 10 February 2010 Emission IB CR LG Rev. Date: Note: Written by: Checked by: Approved by: Installation Guide for the GBInSAR LISAMOBILE system REV. 2.6 ellegi srl c.so magenta, 12 milano sede operativa via petrarca 55 rovello porro co Subject: Installation Guide - LISAMOBILE Creation date: 2010-02-10 Customer Ref.: - Int. Ref.: IB Rev.: 06 Rev. date: 2014-06-12 File: Installation Guide - LISAMOBILE_rev2. 6.doc Special note: Confidential Page: 2 of 43 Status: Confidential, Public © Ellegi srl, 2009 - 2014. All Rights Reserved. Via Petrarca, 55 • 22070 Rovello Porro CO Italy ellegi srl c.so magenta, 12 milano sede operativa via petrarca 55 rovello porro co Subject: Installation Guide - LISAMOBILE Creation date: 2010-02-10 Customer Ref.: - Int. Ref.: IB Rev.: 06 Rev. date: 2014-06-12 File: Installation Guide - LISAMOBILE_rev2. 6.doc Special note: Confidential Page: 3 of 43 Status: Confidential, Public Index Index 3 Licence Agreement 5 Glossary 9 Installation guide for the GBInSAR LISAMOBILE System 11 Introduction 11 Warnings 11 Builder 12 System’s data 12 Important security information 12 Using the LISAMOBILE system 13 Avoid water and damp environments 13 Fixing the LISAMOBILE system 13 Avoid eye straining 13 Glass components 14 Exposition to radiofrequency energy 14 More information 14 Radio frequency interference 14 Vehicles 14 Electronic devices 15 Medical devices 15 Important information on the use and handling of the LISAMOBILE system 15 Trasporting the LISAMOBILE system 15 Using plugs and sockets 15 Keep the LISAMOBILE system into a controlled temperatures range 15 Information on the waste disposal and recycling 16 European Community Compliance Statement 16 System components 16 ellegi srl c.so magenta, 12 milano sede operativa via petrarca 55 rovello porro co Subject: Installation Guide - LISAMOBILE Creation date: 2010-02-10 Customer Ref.: - Int. Ref.: IB Rev.: 06 Rev. date: 2014-06-12 File: Installation Guide - LISAMOBILE_rev2. 6.doc Special note: Confidential Page: 4 of 43 Status: Confidential, Public System components main features 18 Mounting the GBInSAR LISAMOBILE system 22 Connecting to the GBInSAR LISAMOBILE system 30 Changing the GBInSAR LISAMOBILE system antennas 30 Maintenance operations 32 Declaration of conformity regarding the directives RoHS 2002/95/CE and WEEE 2002/96/CE 37 CE Marking 37 Declarations and notices regarding the FCC-IC directives 38 Technical data 40 Contacts, Warnings and Legals 42 WARNING 42 CONFIDENTIALITY 42 ellegi srl c.so magenta, 12 milano sede operativa via petrarca 55 rovello porro co Subject: Installation Guide - LISAMOBILE Creation date: 2010-02-10 Customer Ref.: - Int. Ref.: IB Rev.: 06 Rev. date: 2014-06-12 File: Installation Guide - LISAMOBILE_rev2. 6.doc Special note: Confidential Page: 5 of 43 Status: Confidential, Public Licence Agreement IMPORTANT, READ CAREFULLY. UNLESS IT IS SUPERSEDED BY A SIGNED LICENSE AGREEMENT BETWEEN YOU AND ELLEGI SRL, ELLEGI SRL IS WILLING TO LICENSE THE SOFTWARE, DATA, OR DOCUMENTATION TO YOU ONLY ON THE CONDITION THAT YOU ACCEPT ALL OF THE TERMS AND CONDITIONS CONTAINED IN THIS ELLEGI SRL LICENSE AGREEMENT. PLEASE READ THE TERMS AND CONDITIONS CAREFULLY. THE SOFTWARE, DATA, OR DOCUMENTATION WILL NOT BEGIN DOWNLOADING TO OR INSTALL ONTO YOUR COMPUTER SYSTEM UNTIL YOU HAVE MANIFESTED YOUR ASSENT TO THE TERMS AND CONDITIONS OF THE ELLEGI SRL LICENSE AGREEMENT BY CLICKING "I accept the License Agreement". IF YOU DO NOT AGREE TO THE TERMS AND CONDITIONS AS STATED, THEN ELLEGI SRL IS UNWILLING TO LICENSE THE SOFTWARE, DATA, OR DOCUMENTATION TO YOU AND YOU SHOULD CLICK "I do not accept the License Agreement", IN WHICH EVENT, THE SOFTWARE, DATA, OR DOCUMENTATION WILL NOT BE DOWNLOADED TO OR INSTALLED ONTO YOUR COMPUTER SYSTEM. ELLEGI SRL LICENSE AGREEMENT Software: MAIN LISAMOBILE . Any versions. This ELLEGI SRL License Agreement (hereinafter referred to as "License Agreement") is between you ("Licensee") and Ellegi srl ("ELLEGI SRL"), c.so magenta 12 I-20123 milano Italy c.f. /p. i.v.a. IT05903450962 iscr. reg. impr. di milano, r.e.a 1857197 Operative and administrative headquarters: via xx settembre, 34 I-20025 legnano mi Italy ARTICLE 1.DEFINITIONS Definitions.As used herein, the following words, phrases, or terms in this License Agreement shall have the following meanings: (a) "Data" means any ELLEGI SRL or third party data vendor(s) digital data set(s) including, but not limited to, geographic, vector data, raster, reports, or associated tabular attributes in ELLEGI SRL software compatible format(s) supplied under this License Agreement. (b) "Documentation" means all of the printed and digital materials including, but not limited to, user documentation, training documentation, or technical information and briefings supplied under this License Agreement. (c) "License Manager" means the nondestructive license management software program or hardware key, or similar copy protection mechanism, which controls the distribution of the licensed number of Software copies to requesting end user(s) of Licensee. (d) "Software" means the actual copy of all or any portion of ELLEGI SRL's proprietary software technology, computer software code, components, dynamic link libraries (DLLs), and programs delivered on any media, including, but not limited to, alpha, beta, prerelease, restricted version(s), or final commercial release provided in source, object, or executable code format(s), inclusive of backups, updates, service packs, sample code or merged copies permitted hereunder or subsequently supplied under this License Agreement. ARTICLE 2.INTELLECTUAL PROPERTY RIGHTS AND RESERVATION OF OWNERSHIP The Software, Data, and …
Text truncated - open the document above for the full version.
ellegi srl c.so magenta, 12 milano sede operativa via petrarca 55 rovello porro co Subject: Installation Guide - LISAMOBILE Creation date: 2010-02-10 Customer Ref.: - Int. Ref.: IB Rev.: 06 Rev. date: 2014-06-12 File: Installation Guide - LISAMOBILE_rev2. 6.doc Special note: Confidential Page: 24 of 43 Status: Confidential, Public positioner fixing plates slide the whole linear positioner towards the front of the system and away from the engine end. 2. Attach each fixing plate to its counterplate inserting four bail head ¼ turn studs in the fixing plate customized holes (Figure 8). Optionally also four M5 security screws can be inserted in each fixing plate (always install the security screws with their o-rings). Figure 8: Step 2 of the installation procedure. Attaching the PLLM fixing plates to the counterplates. ellegi srl c.so magenta, 12 milano sede operativa via petrarca 55 rovello porro co Subject: Installation Guide - LISAMOBILE Creation date: 2010-02-10 Customer Ref.: - Int. Ref.: IB Rev.: 06 Rev. date: 2014-06-12 File: Installation Guide - LISAMOBILE_rev2. 6.doc Special note: Confidential Page: 25 of 43 Status: Confidential, Public Figure 9: Step 3 of the installation procedure. Earthing of the linear positioner engine. 3. Use the earthing flap mounted on the upper right screw of the engine to perform the earthing (Figure 9). An earthing cable of adeguate diameter must be used to connect the engine earthing flap to an earthing plant. 4. Mount the system measuring head (LM) on the linear positioner sledge (Figure 10). When the system is switched off, the measuring head should be kept in the “transport position”. On the linear positioner sledge there are two pins similar to the one found on the system counterplate that are used to match the sledge and the measuring head base plate. There are also tree matching marks both on the sledge and on the measuring head base plate that must be aligned if the measuring head is mounted in the correct position. After having set down the measuring head on the linear positioner head it has to be secured with four bail head ¼ turn studs and optionally with four M5 security screws (always install the security screws with their o-rings). NOTE: before securing the measuring head on the linear positioner moving sledge ensure that the sledge pins are touched on their rear and right side, i.e. once the sledge pins are inserted slide the measuring head base plate (without moving the linear positioner sledge) towards the front of the system and away from the engine end. ellegi srl c.so magenta, 12 milano sede operativa via petrarca 55 rovello porro co Subject: Installation Guide - LISAMOBILE Creation date: 2010-02-10 Customer Ref.: - Int. Ref.: IB Rev.: 06 Rev. date: 2014-06-12 File: Installation Guide - LISAMOBILE_rev2. 6.doc Special note: Confidential Page: 26 of 43 Status: Confidential, Public Figure 10: Step 4 of the installation procedure. Mounting the measuring head LM on the linear positioner sledge. 5. Leaving the measuring head in the transport position connect it with the 14 pins standard MIL connector of the cable chain and put the screw top that was on the head plug on the rest plug of the cable chain (Figure 11). ellegi srl c.so magenta, 12 milano sede operativa via petrarca 55 rovello porro co Subject: Installation Guide - LISAMOBILE Creation date: 2010-02-10 Customer Ref.: - Int. Ref.: IB Rev.: 06 Rev. date: 2014-06-12 File: Installation Guide - LISAMOBILE_rev2. 6.doc Special note: Confidential Page: 27 of 43 Status: Confidential, Public Figure 11: Step 5 of the installation procedure. Connect the measuring head LM to the cable chain. 6. Bring the power base (PBLM) in a safe position and connect it to the linear positioner junction box using the umbilical cable (LMUC). Note: the umbilical cable should not be stretched; before plugging it make sure that the power base and the linear positioner are close enough. 7. Verify that the security switch of the power base and the two red switches near its display are switched off and connect the power base (PBLM) to a power line using the power cable (LMPC). Note: make sure that also the power cable is not stretched or tangled (Figure 12). ellegi srl c.so magenta, 12 milano sede operativa via petrarca 55 rovello porro co Subject: Installation Guide - LISAMOBILE Creation date: 2010-02-10 Customer Ref.: - Int. Ref.: IB Rev.: 06 Rev. date: 2014-06-12 File: Installation Guide - LISAMOBILE_rev2. 6.doc Special note: Confidential Page: 28 of 43 Status: Confidential, Public Figure 12: Steps 6 and 7 of the installation procedure. Connect the umbilical cable and the power cable. 8. Unscrew the protractor lock lever and rotate the measuring head pointing the radar antennas towards the target of the measures. Once the head is in the desired position secure it tightening again the protractor lock lever (Figure 13). ellegi srl c.so magenta, 12 milano sede operativa via petrarca 55 rovello porro co Subject: Installation Guide - LISAMOBILE Creation date: 2010-02-10 Customer Ref.: - Int. Ref.: IB Rev.: 06 Rev. date: 2014-06-12 File: Installation Guide - LISAMOBILE_rev2. 6.doc Special note: Confidential Page: 29 of 43 Status: Confidential, Public Figure 13: Step 8 of the installation procedure. Point the radar antennas towards the target. 9. Verify that every possible obstacle to the system moving parts is removed and that no one is standing in front of the radar antennas. 10. Switch to the “On” position the security switch of the power base; the system will switch on and the message “InSAR LISA MOBILE ELLEGI srl lisalab” appears on the power base display (Figure 14). 11. Lift the protective screen of the power base display and switch on the two red switches on the “I” position; firstly the “LP” switch and then the “MW” switch (Figure 14). Then close the display protective screen and secure it with the two fixing screws. The system is now ready to start the measurements. Only skilled users should operate it referring…
Text truncated - open the document above for the full version.
... a step ahead in monitoring structures and natural hazards by ellegi srl 9 8 7 27 June 2014 Revision CR IB DL 6 12 June 2014 Revision CR IB DL 5 14 March 2014 Revision - New features of the release 4.5.0 IB DL CR 4 15 May 2013 Revision - New features of the release 4.3.5 IB DL CR 3 27 September 2011 Revision - New features of the release 4.3 IB DL CR 2 03 December 2010 Revision IB DL CR 1 13 July 2010 Revision IB CR LG 0 23 April 2010 Emission IB CR LG Rev. Date: Note: Written by: Checked by: Approved by: User’s Guide for the software Leda LISAMOBILE system REV. 0.7 ... a step ahead in monitoring structures and natural hazards by ellegi srl ellegi srl c.so magenta, 12 milano sede operativa via petrarca 55, rovello porro co Subject: User’s guide: Main LISAMOBILE release 4.5.0 Creation date: 2010-04-23 Customer Ref.: - Int. Ref.: IB Rev.: 07 Rev. date: 2014-06-27 File: User's Guide - Main LiSA Mobile_release_4.5.0.r7.doc Special note: Confidential Page: 2 of 31 Status: Confidential Ellegi srl, 2009 - 2014. All Rights Reserved. Via Petrarca 55 • 22070 Rovello Porro CO Italy ... a step ahead in monitoring structures and natural hazards by ellegi srl ellegi srl c.so magenta, 12 milano sede operativa via petrarca 55, rovello porro co Subject: User’s guide: Main LISAMOBILE release 4.5.0 Creation date: 2010-04-23 Customer Ref.: - Int. Ref.: IB Rev.: 07 Rev. date: 2014-06-27 File: User's Guide - Main LiSA Mobile_release_4.5.0.r7.doc Special note: Confidential Page: 3 of 31 Status: Confidential WARNING This document is only and specifically referred to the LiSALab (© & ™) technology and to the GBInSAR LiSALab systems, and not to other similar technologies or instrumentations, and it is intended to be used only by experienced professionals. This document can never replace the professional knowledge of the users. People that use this technology, data and information are responsible of their supervision, their management and their control. These responsibilities include the choice of the appropriate uses of these technology, data and information to obtain the desired results. The users of the technology, data and information are moreover responsible of the evaluation of the suitability of independent procedures to examine the accuracy and the reliability of eventual interpretations and uses. ... a step ahead in monitoring structures and natural hazards by ellegi srl ellegi srl c.so magenta, 12 milano sede operativa via petrarca 55, rovello porro co Subject: User’s guide: Main LISAMOBILE release 4.5.0 Creation date: 2010-04-23 Customer Ref.: - Int. Ref.: IB Rev.: 07 Rev. date: 2014-06-27 File: User's Guide - Main LiSA Mobile_release_4.5.0.r7.doc Special note: Confidential Page: 4 of 31 Status: Confidential Index Index 4 Licence Agreement 5 User’s guide for the LISAMOBILE setting parameters software 13 LiSAMobile system tune up 23 Spatial Resolution graphs and parameters setting depending on the distance from the monitored target 26 IF value setting 28 Example: a procedure for the system’s parameters setting 29 Antennas types and emission diagrams 29 Precautions for the system switching off 30 Contacts, Warnings and Legals 31 WARNING 31 CONFIDENTIALITY 31 ... a step ahead in monitoring structures and natural hazards by ellegi srl ellegi srl c.so magenta, 12 milano sede operativa via petrarca 55, rovello porro co Subject: User’s guide: Main LISAMOBILE release 4.5.0 Creation date: 2010-04-23 Customer Ref.: - Int. Ref.: IB Rev.: 07 Rev. date: 2014-06-27 File: User's Guide - Main LiSA Mobile_release_4.5.0.r7.doc Special note: Confidential Page: 5 of 31 Status: Confidential Licence Agreement IMPORTANT, READ CAREFULLY. UNLESS IT IS SUPERSEDED BY A SIGNED LICENSE AGREEMENT BETWEEN YOU AND ELLEGI SRL, ELLEGI SRL IS WILLING TO LICENSE THE SOFTWARE, DATA, OR DOCUMENTATION TO YOU ONLY ON THE CONDITION THAT YOU ACCEPT ALL OF THE TERMS AND CONDITIONS CONTAINED IN THIS ELLEGI SRL LICENSE AGREEMENT. PLEASE READ THE TERMS AND CONDITIONS CAREFULLY. THE SOFTWARE, DATA, OR DOCUMENTATION WILL NOT BEGIN DOWNLOADING TO OR INSTALL ONTO YOUR COMPUTER SYSTEM UNTIL YOU HAVE MANIFESTED YOUR ASSENT TO THE TERMS AND CONDITIONS OF THE ELLEGI SRL LICENSE AGREEMENT BY CLICKING "I accept the License Agreement". IF YOU DO NOT AGREE TO THE TERMS AND CONDITIONS AS STATED, THEN ELLEGI SRL IS UNWILLING TO LICENSE THE SOFTWARE, DATA, OR DOCUMENTATION TO YOU AND YOU SHOULD CLICK "I do not accept the License Agreement", IN WHICH EVENT, THE SOFTWARE, DATA, OR DOCUMENTATION WILL NOT BE DOWNLOADED TO OR INSTALLED ONTO YOUR COMPUTER SYSTEM. Software: LEDA – LISAMOBILE system. Any versions. This ELLEGI SRL License Agreement (hereinafter referred to as "License Agreement") is between you ("Licensee") and Ellegi srl ("ELLEGI SRL"), c.so magenta, 12 I-20123 milano Italy c.f. /p. i.v.a. IT05903450962 iscr. reg. impr. di milano, r.e.a 1857197 Operative and administrative headquarters: via petrarca 55, I-22070 rovello porro co ARTICLE 1.DEFINITIONS Definitions. As used herein, the following words, phrases, or terms in this License Agreement shall have the following meanings: (a) "Data" means any ELLEGI SRL or third party data vendor(s) digital data set(s) including, but not limited to, geographic, vector data, raster, reports, or associated tabular attributes in ELLEGI SRL software compatible format(s) supplied under this License Agreement. (b) "Documentation" means all of the printed and digital materials including, but not limited to, user documentation, training documentation, or technical information and briefings supplied under this License Agreement. (c) "License Manager" means the nondestructive license management software program or hardware key, or similar copy protection mechanism, which controls the distribution of the licensed number of Software copies to requesting end user(s) of Licensee. (d) "Software" means the actual copy of all or any portion of ELLEGI SRL's proprietary software technology, computer software code, components, dynami…
Text truncated - open the document above for the full version.
Test report no.: 1-7779/14-01-02_AnnexA 2014-05-23 Page 1 of 7 1-7779/14-01-02 Annex A This test report annex is electronically signed and valid without handwriting signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test report annex authorised: Meheza Walla Testing Manager Test report no.: 1-7779/14-01-02_AnnexA 2014-05-23 Page 2 of 7 External photos of the EUT Photo 1: Photo 2: Test report no.: 1-7779/14-01-02_AnnexA 2014-05-23 Page 3 of 7 Photo 3: Photo 4: Test report no.: 1-7779/14-01-02_AnnexA 2014-05-23 Page 4 of 7 Photo 5: Photo 6: Test report no.: 1-7779/14-01-02_AnnexA 2014-05-23 Page 5 of 7 Photo 7: Photo 8: Test report no.: 1-7779/14-01-02_AnnexA 2014-05-23 Page 6 of 7 Photo 9: Test report no.: 1-7779/14-01-02_AnnexA 2014-05-23 Page 7 of 7 Document history Version Applied changes Date of release Initial release 2014-05-23
ellegi srl c.so magenta, 12 milano sede operativa via petrarca 55 rovello porro co Subject: Installation Guide - LiSAmobile K09 Creation date: 2010-02-10 Customer Ref.: - Int. Ref.: IB Rev.: 04 Rev. date: 2014-05_16 File: Installation Guide - LiSAmobile K09_rev2.2.doc Special note: Confidential Page: 38 of 41 Status: Confidential, Public FCC-IC LABEL: Figure 23: FCC-IC Label Position This device complies with Part 15 of the FCC Rules and with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. ELLEGI SRL Model: LiSAmobile FCC ID: 2AB7MLISAMOBILE IC: 11895A-LISAMOBILE
ELLEGI SRL Model: LISAMOBILE FCC ID: 2AB7MLISAMOBILE IC: 11895A-LISAMOBILE
Test report no.: 1-7779/14-01-02_AnnexB 2014-05-23 Page 1 of 6 1-7779/14-01-02 Annex B This test report annex is electronically signed and valid without handwriting signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test report annex authorised: Meheza Walla Testing Manager Test report no.: 1-7779/14-01-02_AnnexB 2014-05-23 Page 2 of 6 Internal photos of the EUT Photo 1: Power Box Photo 2: DC/DC-Converter Test report no.: 1-7779/14-01-02_AnnexB 2014-05-23 Page 3 of 6 Photo 3: Position Controller Photo 4: Measure Head Test report no.: 1-7779/14-01-02_AnnexB 2014-05-23 Page 4 of 6 Photo 5: Tx-Board, front side Photo 6: Tx-Board, back side Test report no.: 1-7779/14-01-02_AnnexB 2014-05-23 Page 5 of 6 Photo 7: Rx-Board, front side Photo 8: Rx-Board, back side Test report no.: 1-7779/14-01-02_AnnexB 2014-05-23 Page 6 of 6 Document history Version Applied changes Date of release Initial release 2014-05-23
Test report no.: 1-7779/14-01-02-C 2014-06-26 Page 11 of 37 9.2 MPE calculation S = PG/4R 2 where S = power density ( in appropriate units, e.g. mW/cm 2 ) P = power input to the antenna (in appropriate units e.g. mW) G = power gain of the antenna in the direction of interest relative to the isotropic radiator R = distance to the centre of radiation of the antenna (appropriate units e.g. cm) Or S = EIRP/4R 2 where EIRP = equivalent isotropically radiated power Calculation: The manufacturer declared a maximal EIRP of 24.5 dBm EIRP: 24.5 dBm (282 mW) Calculated power density S: S= 282 mW / (4 * 20 cm * 20 cm) = 0.056 mW / cm 2 Limit: 1 mW / cm 2 is the reference level for general public exposure according to: FCC OET Bulletin 65, Edition 97-01 Table 1 IC Safety Code 6 Result: The measurement is passed.
2014-06-26 Page 1 of 37 TEST REPORT Test report no.: 1-7779/14-01-02-C Testing laboratory Applicant CETECOM ICT Services GmbH Untertuerkheimer Strasse 6 – 10 66117 Saarbruecken / Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: http://www.cetecom.com e-mail: [email protected] Accredited Testing Laboratory: The testing laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 (2005) by the Deutsche Akkreditierungsstelle GmbH (DAkkS) The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate with the registration number: D-PL-12076-01-01 Area of Testing: Radio Communications & EMC (RCE) Ellegi srl Via Petrarca 55 22070 Rovello Porro CO / ITALY Phone: -/- Fax: -/- Contact: Carlo Rivolta e-mail: [email protected] Phone: +39 02 94 43 50 51 Manufacturer Ellegi srl Via Petrarca 55 22070 Rovello Porro CO / ITALY Test standard/s 47 CFR Part 90 Subpart F- Radiolocation Service RSS-210 Licence-exempt Radio Apparatus (All Frequency Bands): Category I Equipment For further applied test standards please refer to section 3 of this test report. Test Item Kind of test item: Ground Based Synthetic Aperture Radar Model name: LISAMOBILE FCC ID: 2AB7MLISAMOBILE IC: 11895A-LISAMOBILE Frequency: 17.1 – 17.3 GHz Antenna: two external horn antennas for TX and RX Power supply: 24.0 V DC by external power supply Temperature range: -30°C to +50°C This test report is electronically signed and valid without handwriting signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test report authorised: Test performed: Meheza Walla Karsten Geraldy Testing Manager Senior Testing Manager Test report no.: 1-7779/14-01-02-C 2014-06-26 Page 2 of 37 1 Table of contents 1 Table of contents ............................................................................................................................................ 2 2 General information ....................................................................................................................................... 3 2.1 Notes and disclaimer .......................................................................................................................... 3 2.2 Application details ............................................................................................................................... 3 3 Test standard/s ............................................................................................................................................... 3 4 Test environment ............................................................................................................................................ 4 5 Test item .......................................................................................................................................................... 4 5.1 Additional information ........................................................................................................................ 4 6 Test laboratories sub-contracted ................................................................................................................. 4 7 Summary of measurement results ............................................................................................................... 5 8 RF measurements .......................................................................................................................................... 6 8.1 Description of test setup .................................................................................................................... 6 8.1.1 Radiated measurements............................................................................................................. 6 8.1.2 Conducted measurements.......................................................................................................... 7 8.2 Additional comments .......................................................................................................................... 7 9 Measurement results ...................................................................................................................................... 8 9.1 Conducted / radiated peak output power (EIRP) .............................................................................. 8 9.2 MPE calculation ................................................................................................................................. 11 9.3 Occupied bandwidth ......................................................................................................................... 12 9.4 Spurious emissions (emission mask) ............................................................................................. 15 9.5 Spurious emissions (conducted) ..................................................................................................... 18 9.6 Spurious emissions (radiated) ......................................................................................................... 28 9.7 Frequency stability ............................................................................................................................ 33 10 Test equipment and ancillaries used for tests ................................................................................... 34 11 Document history .................................................................................................................................. 36 12 Further information ............................................................................................................................... 36 13 Accreditation Certificate ....................................................................................................................... 37 Test report no.: 1-7779/14-01-02-C 2014-06-26 Page 3 of 37 2 General information 2.1 Notes and disclaimer The test results of thi…
Text truncated - open the document above for the full version.
Test report no.: 1-7779/14-01-02_AnnexD 2014-05-23 Page 1 of 7 1-7779/14-01-02 Annex D This test report annex is electronically signed and valid without handwriting signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test report annex authorised: Meheza Walla Testing Manager Test report no.: 1-7779/14-01-02_AnnexD 2014-05-23 Page 2 of 7 EUT Test setup photos Photo 1: Test report no.: 1-7779/14-01-02_AnnexD 2014-05-23 Page 3 of 7 Photo 2: Photo 3: Test report no.: 1-7779/14-01-02_AnnexD 2014-05-23 Page 4 of 7 Photo 4: Photo 5: Test report no.: 1-7779/14-01-02_AnnexD 2014-05-23 Page 5 of 7 Photo 6: Photo 7: Test report no.: 1-7779/14-01-02_AnnexD 2014-05-23 Page 6 of 7 Photo 8: Photo 9: Test report no.: 1-7779/14-01-02_AnnexD 2014-05-23 Page 7 of 7 Document history Version Applied changes Date of release Initial release 2014-05-23
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 90 | 17.10 GHz - 17.30 GHz | 230.00 mW | 181MF0N | 1650.0000000000 Hz |