Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
User manual Function specification 1. Auto standby: if there is no input signal in 5s, the system will enter into standby status. 2. Low voltage alarm: if the voltage is less than 4.5V, when the user press lock key or unlock key, it will sound blares first, then open or close the lock. 3. Power supply: DC/6V 4 x AA battery 4. Support the transmitter to open the lock 5. Support setting password to open the lock 6. Support the key to open the lock 7. Buzzer remind Sound Status meaning One short beep Key sound One long beep Enter changing password status, change password succeed, transmit coding, password recovery Five short beeps Wrong password, Change password mistake One bass blare Low voltage alarm Transmitter unlock/lock specification 1. Set the power switch to “NO”, then press the learning button “FOB learn”, the buzzer sounds slow ticks, if press till 5s, the buzzer sounds one long tick and go back to standby status, all the stored transmitters are deleted. 2. If release the button in 5s, the buzzer does not sound, it enters into transmitter learning status, press the open key on the transmitter, the buzzer sounds a long tick and go back to standby status, it means learning succeed. If you want to learn another transmitter, do that again. If do not learning any transmitter or learning failure in 10s, the buzzer sounds quickly ticks and goes back to standby status. 3. It can at most store 20pcs transmitters. 4. After learnt, press the lock key on the transmitter, the door will lock; press the unlock key on the transmitter, the door will unlock. Setting password lock/unlock specification 1. Normal use Unock: enter password and press unlock key, if right password, it will one long beep and unlock; if wrong password, it will five short beeps. Lock: enter password and press lock key, if right password, it will one long beep and lock; if wrong password, it will five short beeps. Specification (1).If do not press unlock key or lock key in 5s after entered the password, it needs to enter the password again. (2). If the password is 027, then 27, 0027 and this kind of password are wrong. (3).If the password is more than 8 units, the password is wrong. 2. Change password The default password is 1234. Press and hold on the key “8”, then press lock key, the buzzer sounds a long beep, it enters into change password status, enter the current password, then press lock key, enter a new password, such as 28111376 (less than 8 units), press lock key again and enter the new code 28111376 again, finally press lock key, the buzzer sounds a long beep, it means change password succeed. If the new password is more than 8 units, or the two entered new passwords are not the same, the buzzer will sound five short beeps, it means change password mistake. In the change password status, when it needs to enter a new password, it the user does not enter any password, but press the lock key two times, the password is 0, it means no password, so press the lock key or unlock key can control the lock. 3. Delete password Press and hold on “code reset” till to sound long tick, the password will receover to initial password “1234” Key using specification Use the key to open the lock. FCC Certification Requirements Caution: Any changes or modifications in construction of this device which are not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help.
SHENZHEN EAZYLIFT TECHNOLOGY CO., LTD Building A5, #9 FuYu Road, FuChengAo Industrial park, PingHu town Shenzhen, China Confidentiality Request Letter Page 1 of 1 Rev 2.0 Novermber 29, 2013 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Permanent Confidentiality Request Confidentiality Request regarding application for certification of FCC ID: 2ABFBEC5020BA We hereby request confidential treatment of information accompanying this application as outlined below: - Block Diagram - Operational Description - Schematic The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Client’s signature: Client’s name / title: Qinglin Jiang / Manager Contact information / address: Building A5, #9 FuYu Road, FuChengAo Industrial park, PingHu town Shenzhen, China TEL: 86-0755-33828381 FAX: 86-0755-33828384 E-mail: [email protected]
External Photo
FCC Certification Label FCC ID: 2ABFBEC5020BA Label Location on EUT EUT Bottom View/ FCC ID Label Location
Internal Photo Antenna
FCC PART 15 CLASS B EMI MEASUREMENT AND TEST REPORT For SHENZHEN EAZYLIFT TECHNOLOGY CO., LTD Building A5, #9 FuYu Road, FuChengAo Industrial park, PingHu town, ShenZhen, China FCC ID:2ABFBEC5020BA Dec 02, 2013 This Report Concerns: Original Report Equipment Type: Remote Control Camper Lock Test Engineer: Lisa Chen Report No.: BSL13111079Y-1ER-3 Receive EUT Date/Test Date: Nov. 25, 2013 / Nov. 25-Dec. 02, 2013 Reviewed By: Sky Zhang Prepared By: BSL Testing Co.,LTD. NO. 24, ZH Park, Nantou, Shenzhen, 518000 China Tel: 86- 755-26508703 Fax: 86- 755-26508703 Note: The test report is specially limited to the above company and this particular sample only. It may not be duplicated without prior written consent of BSL Testing Co.,LTD. This report must not be used by the client to claim product certification, approval,or endorsement by NVLAP, NIST or any agency of the US Government. FCC ID: 2ABFBEC5020BA BSL13111079Y-1ER-3 Page 2/14 TABLE OF CONTENTS 1. GENERAL INFORMATION .................................................................................................... 3 1.1. Report information............................................................................................................ 3 2. PRODUCT DESCRIPTION ...................................................................................................... 4 2.1. EUT Description ............................................................................................................... 4 2.2. Block Diagram of EUT Configuration ............................................................................. 4 2.3. Support Equipment List .................................................................................................... 4 2.4. Test Conditions .................................................................................................................4 2.5. TEST Results SUmmary................................................................................................... 5 3. TEST EQUIPMENT USED ....................................................................................................... 6 4. CONDUCTED EMISSION TEST............................................................................................. 7 4.1. Measurement Uncertainty................................................................................................. 7 4.2. Block Diagram of Test Setup............................................................................................ 7 4.3. Test Standard .................................................................................................................... 7 4.4. Conducted Emission Limit(Class B) ................................................................................ 8 4.5. EUT Configuration on Test .............................................................................................. 8 4.6. Operating Condition of EUT ............................................................................................ 8 4.7. Test Procedure ..................................................................................................................8 4.8. Test Result ........................................................................................................................ 8 5. RADIATED EMISSION MEASUREMENT ........................................................................... 9 5.1. Measurement Uncertainty................................................................................................. 9 5.2. Block Diagram of EUT Configuration ............................................................................. 9 5.3. Test Standard .................................................................................................................... 9 5.4. Radiated Emission Limit(Class B) ................................................................................. 10 5.5. EUT Configuration on Test ............................................................................................ 10 5.6. Operating Condition of EUT .......................................................................................... 10 5.7. Test Procedure ................................................................................................................ 11 5.8. Test Result ...................................................................................................................... 11 FCC ID: 2ABFBEC5020BA BSL13111079Y-1ER-3 Page 3/14 1. GENERAL INFORMATION 1.1. Report information 1.1.1.This report is not a certificate of quality; it only applies to the sample of the specific product/equipment given at the time of its testing. The results are not used to indicate or imply that they are application to the similar items. In addition, such results must not be used to indicate or imply that BSL approves recommends or endorses the manufacture, supplier or use of such product/equipment, or that BSL in any way guarantees the later performance of the product/equipment. 1.1.2.The sample/s mentioned in this report is/are supplied by Applicant, BSL therefore assumes no responsibility for the accuracy of information on the brand name, model number, origin of manufacture or any information supplied. 1.1.3.Additional copies of the report are available to the Applicant at an additional fee. No third part can obtain a copy of this report through BSL, unless the applicant has authorized BSL in writing to do so. Test Facility - The test site used to collect the radiated data is located on the address of BSL Testing Co.,LTD. (FCC Registered Test Site Number: 191509) on NO. 24, ZH Park, Nantou, Shenzhen, 518000 China The Test Site is constructed and calibrated to meet the FCC requirements. FCC ID: 2ABFBEC5020BA BSL13111079Y-1ER-3 Page 4/14 2. PRODUCT DESCRIPTION 2.1. EUT Description Applicant : SHENZHEN EAZYLIFT TECHNOLOGY CO., LTD Address : Building A5, #9 FuYu Road, FuChengAo Industrial park, PingHu town, ShenZhen, China Manufacture…
Text truncated - open the document above for the full version.
Radiated emissions test
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | 433.98 MHz - 433.98 MHz | - |

Lock Remote Control
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter