2ABG7TET-340Infrared Thermometer

Truly Instrument Ltd.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 17, 2014
Application Purpose
Original Equipment
Date of Application
Aug 14, 2014
Equipment Note
Infrared Thermometer
Frequency Range
2402.00000000 - 2480.00000000
Company
Truly Instrument Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

This thermometer has a memory for 10 readings. After each reading, the temperature is automatically recorded in the first empty memory. If all the memory space is used, the first memory is automatically deleted and replaced by the new reading and so on. To read the memorised temperatures: The product must be switched off. • Press the button until MEMORY appears on the screen. The information appears on the screen alternately. example : • To read all of the 10 temperature readings in the memory, press briefly and successively on : the different temperatures are displayed one after another as the ear or forehead mode in which they have been taken. • To exit the memory mode, press the button or wait for the thermometer to switch off automatically. To delete the memorised temperatures: • Enter in memory mode . • Press until appears. The thermometer switches off Switching off To switch the appliance off: Press the button until the screen displays OFF. Or the appliance switches off automatically after 60 seconds. Memory function Infrared Ear & Forehead Thermometer MODEL: TET-340 User Manual Rev.00 2011/06/14 MANUFACTURER: Truly Instrument Ltd. 2/F., Chung Shun Knitting Centre, 1-3 Wing Yip St, Kwai Chung, N.T., HONG KONG TEL: (852) 2487 9803 FAX: (852) 2146 5756, 2480 0018, 2480 0126 EC-REPRESENTATIVE: Wellkang Ltd t/a Wellkang Tech Consulting Suite B, 29 Harley Street, LONDON W1G 9QR, United Kingdom -1--2--3--4- -8--7--6--5- 1. Lens 2. Probe 3. Battery compartment 4. Luminous diodes to show temperature mode : ear or forehead 5. Screen 6. Take temperature and memory function button 7. On/Off and Ear or forehead temperature Mode button 8. Protection/vertical storage cap. Description Precautions for use This ear and forehead thermometer receives the infra-red rays emitted by the skin’s surface and in the ear drum area. It allows you to check your child’s temperature easily. This is how to use the appliance: • TET-340 is exclusively dedicated to take ear or forehead temperatures. We would like to re-iterate that this appliance does not replace the advice of a doctor. In case of doubt or fever, contact your doctor. The simple take of temperature cannot be considered as a medical advice, DO NOT modify the proportion of any drugs prescribed by your doctor without seeking medical advice first. • To ensure the reading is accurate, the probe and the lens must be absolutely clean. • Do not use the thermometer if it has been dropped or shows any signs of damage. • Always place the protection cap back after use. • In cases of movement from one Warning, this appliance is not suitable for detecting hypothermia. Average temperatures room to another, wait for half an hour minimum before using the appliance. • Wait for half an hour after physical training, bathing or eating before measuring temperature. • Keep the thermometer out of reach of children. • Do not expose the thermometer: - To any warm sources (radiator, sun rays, ...) - To dust or humidity. • Never immerse the thermometer in liquid. • Do not touch the lens with your fingers. BODY TEMPERATURE: the normal human body temperature varies during the day. It is measured along a scale of values defined according to the part of the body where the temperature is taken: - Rectal measurement: 36,6°- 37,8°C - Axillary measurement (under the arm): 34,7°- 37,3°C - Oral measurement (in the mouth) or forehead: 35,5°- 37,5°C - Ear measurement: 35,8°- 37,8°C Forehead temperature Ear temperature Rectal temperature Oral temperature Axillary temperature 36.1°C 36.4°C 37.0°C 36.6°C 36.1°C Technical specifications Comments: these technical specifications may be subject to modifications to improve the appliance, without prior warning. Installing the battery The appliance is delivered with a lithium battery 3V (CR2032) already in place. At the first use, open the battery cover then remove the strip which ensures the protection of the battery (fig. 1/ fig. 2). Replace the cover (fig. 3). Installing the battery, Open the battery compartment and place a new button lithium battery CR2032 3 volts polarity + on the top. Replace the cover. Keep the battery out of reach of children. IMPORTANT: When installing a new battery. always wait half hour an hour before using the appliance. Screen resolution 0.1°C Measurement range 20°C - 42.2°C Precision 32°C ~ 42°C: +/-0.2°C <32°C and >42°C +/-0.3°C Operation conditions-room temperature +16°C / + 35°C Relative humidity less than 85% Storage conditions -20°C / +80°C Relative humidity less than 95% Energy source 1 lithium battery 3V type CR2032 Service life: approximately 5000 measures As for all thermometers, slight variations in temperature may be displayed one after another: it is therefore recommended to take several readings (removing the thermometer from the ear between each reading) and take the highest reading into account. Forehead measurement • Remove the protection cap. • To switch on press and maintain the button until the indications in fig. 4 are displayed in the screen the appliance comes automatically displays the Ear mode. • Press the button to select the forehead mode. The screen shows the corresponding function fig. 7 and the luminous diode corresponding to the symbol blink 5 times. • Place the probe in the middle of the forehead. Press the button . Slowly slide the probe on the skin to the temple fig. 8. • While taking the temperature, the screen indicates and audible bips sound. • As soon as the probe is placed on the area of the temple, release the button , wait for the validation sound beep before removing the thermometer. • Read the temperature on the screen. • The temperature is automatically recorded. Notice: This temperature reading must be considered as an estimation. The temperature reading of the forehead can be influence by environmental conditions because the probe is more sensitive to perspiration, sebum, physical activity and environmental temperature. It is recommended that you wipe the forehead before tak…

Text truncated - open the document above for the full version.

Cover Letter(s)

Truly Instrument Ltd. 022311 – 6 Authority to Act as Agent Date: 2014-07-30 American Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 To Whom It May Concern: Shenzhen Huatongwei International Inspection Co., Ltd / Hans Hu is authorized to act on our behalf, until otherwise notified, for applications to American Certification Body, Inc. (ACB). We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you, Agency Agreement Expiration Date: _____2015-07-30_____ By: Jianhao Yang (Signature 1 ) (Print name) Title: Engineer On behalf of: Truly Instrument Ltd. (Company Name) Telephone: 86-0660-3380070 1 - Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters should be placed on appropriate letterhead.

Cover Letter(s)

Truly Instrument Ltd. 022311 – 6 Request for Confidentiality Date: 2014-07-30 Subject: Confidentiality Request for: FCC ID: 2ABG7TET-340 Pursuant to FCC 47 CRF 0.457(d) and 0.459 and IC RSP-100, Section 10, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term External Photos Short Term Permanent* 2 Internal Photos Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Parts List & Placement/BOM Short Term Permanent Tune-Up Procedure Short Term Permanent Schematics Short Term Test Setup Photos Short Term Permanent* User’s Manual *Note: ______(Insert Explanation as Necessary)______ Truly Instrument Ltd has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of ___(specify number of days not to exceed 180) 3 ___ days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify ACB in the event information regarding the product or the product is made available to the public. ACB will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. NOTE for Industry Canada Applications: The applicant understands that until such time that IC distinguishes between Short Term and Permanent Confidentiality, either type of marked exhibit above will simply be marked Confidential when submitted to IC. Sincerely, Jianhao Yang By: (Signature4) (Print name) 2 - The asterisked items (*) require further justification before permanent confidentiality will be allowed. These also currently require review by the FCC under their Permit-But-Ask policy before the grant is issued and can delay completion of an application. Further justification should be added to the note above. One such example for a potted device would be: “The EUT is FULLY potted using a non-removable epoxy based material. Removal of potting material causes irreparable damage to internal circuitry. See photographs exhibits that outline the device before and after potting.” 3 - Please refer to http://acbcert.com/documents/misc-docs/Memo-Short-Term-Vs-Standard-Confidentiality.pdf for complete details. 4 - Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters should be placed on appropriate letterhead.

External Photos

Report 6. Ext No : TREE 1 ternal an 1406015201 nd Intern nal Phot Extern tos of th al photos he EUT of the EU UT P age 30 of 333 Report No : TREE11406015201 P age 31 of 333

ID Label/Location Info

Laabel Locat ion 2ABG7TET-340

Internal Photos

Report No : TREE11406015201 Interna al photos of the EU T P age 32 of 333 Report No : TREE11406015201 ................. ......End of R Report.......... ............... P age 33 of 333

Test Report

Report R FCC ID. .. Applican Address .. Manufactu Address.. Test item Trade Ma Model/Typ Listed Mo Standard Date of re Date of te Date of is Result .... Compiled ( position + Supervise (position+ Approved (position + Testing L Address .. Shenzhen This publi Huatongw Shenzhen for damag context. Reference No .................... t’s name ..... .................... urer.............. .................... m description ark ................ pe reference odel(s) .......... d ................... eceipt of test esting............ sue............ .............. ...... by +printednam ed by +printedname by +printedname Laboratory N .................... n Huatongw cation may b wei Internatio n Huatongwe ges resulting o. ................. .................... .................... .................... .................... .................... n ................. .................... e ................... .................... .................... sample...... .................. ..................... .................. e+signature) e+signature) e+signature) Name .......... .................... wei Internatio be reproduce onal Inspectio ei Internation from the rea TES ... : TREE ... : 2ABG ... : Truly .... : Truly .....: Truly ......: Truly ... : Infra .... : TRUL .... : TET- .... : / ... : FCC .....: Jun 2 ......: Jun2 ......: Jul 1 ......: PASS ) ... : File a .... : Proje .... : RF M ... : She n .... : Keji N onal Inspec ed in whole o on Co., Ltd is nal Inspection ader's interpr ST RE E140601520 G7TET-340 y Instrumen y Industrial A y Instrument y Industrial A ared Ear The LY -340 CFR Title 4 24, 2014 25, 2014- Jul 6, 2014 S administrator ect Engineer Manager Han nzhen Huato Nan No.12 R ction Co., Ltd or in part for s acknowled n Co., Ltd tak retation of th EPOR 01 nt Ltd. Area,Shanwe Ltd. Area,Shanwe ermometer 47 Part 15 Su 16, 2014 rs May Hu Lion Cai ns Hu ongwei Inter Road, Hi-tech d. All rights non-commer ged as copy kes no respo e reproduce RT R/C......... iCity,Guang d iCity,Guangd ubpart C Se rnational Ins h Park, Shen reserved. rcial purpose right owner a onsibility for a d material du ....:34198 dongProvinc dongProvinc ection 15.247 spection Co nzhen, China es as long as and source o and will not a ue to its plac ce,China. ce,China. 7 o., Ltd a s the Shenzh of the materia assume liabil cement and hen al. lity Report No:TREE1406015201 Page 2 of 32 Contents 1. TEST STANDARDS AND TEST DESCRIPTION 3 1.1. Test Standards 3 1.2. Test Description 3 2. SUMMARY 4 2.1. Client Information 4 2.2. Product Description 4 2.3. EUT operation mode 5 2.4. EUT configuration 5 2.5. Modifications 5 3. TEST ENVIRONMENT 6 3.1. Address of the test laboratory 6 3.2. Test Facility 6 3.3. Environmental conditions 7 3.4. Statement of the measurement uncertainty 7 3.5. Equipments Used during the Test 8 4. TEST CONDITIONS AND RESULTS 9 4.1. Antenna requirement 9 4.2. Conducted Emission (AC Main) 10 4.3. Conducted Peak Output Power 11 4.4. Power Spectral Density 13 4.5. 6dB bandwidth 15 4.6. Band Edge 17 4.7. Spurious Emission (conducted) 20 4.8. Spurious Emission (radiated) 23 5. TEST SETUP PHOTOS OF THE EUT 2 8 6. EXTERNAL AND INTERNAL PHOTOS OF THE EUT 2 9 Report No:TREE1406015201 Page 3 of 32 1. TEST STANDARDS ANDTEST DESCRIPTION 1.1. Test Standards The tests were performed according to following standards: FCC Rules Part 15.247:Frequency Hopping, Direct Spread Spectrum and Hybrid Systems that are in operation within the bands of 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz. ANSI C63.10:AmericanNationalStandardforTestingUnlicensedWirelessDevices KDB558074 D01 V03: Guidance for Performing Compliance Measurements on Digital Transmission Systems (DTS) Operating Under §15.247 1.2. Test Description Test Item Section in CFR 47 Result Antenna requirement 15.203/15.247 (c) Pass Line Conducted Emission (ACMain) 15.207 Not Application Conducted Peak Output Power 15.247 (b)(3) Pass Power Spectral Density 15.247 (e) Pass 6dB Bandwidth 15.247 (a)(2) Pass Band Edge 15.247(d) Pass Spurious Emission 15.205/15.209 Pass Remark: The measurement uncertainty is not included in the test result. Report No:TREE1406015201 Page 4 of 32 2. SUMMARY 2.1. Client Information Applicant: Truly Instrument Ltd. Address: Truly Industrial Area,Shanwei City,Guangdong Province,China . Manufacturer: Truly Instrument Ltd. Address: Truly Industrial Area,Shanwei City,Guangdong Province,China . 2.2. Product Description Name of EUT Infrared Ear Thermometer Trade Mark: TRULY Model No.: TET-340 Listed Model(s): / Power supply: DC 3.0V From internal battery Adapter information: \ Bluetooth Version: Supported BT4.0 Modulation: GFSK Operation frequency: 2402MHz~2480MHz Channel number: 40 Channel separation: 2MHz Antenna type: Internal Antenna Antenna gain: 0.0dBi Operation Frequency List: Channel Frequency (MHz) 1 2402 2 2404 ...... 19 2438 20 2440 21 2442 ...... 39 2478 40 2480 Note: In section 15.31(m), regards to the operating frequency range over 10 MHz, the Lowest frequency, the middle frequency, and the highest frequency of channel were selected to perform the test, please see the above gray bottom. Report No:TREE1406015201 Page 5 of 32 2.3. EUT operation mode The EUT has been tested under typical operating condition. The Applicant providessoftware to control the EUT for staying in continoustransmitting and receiving mode for testing. 2.4. EUT configuration The following peripheral devices and interface cables were connected during the measurement: ● - supplied by the manufacturer ○ - supplied by the lab ○ PowerCable Length (m) : / Shield : / Detachable : / ○ Multimeter Manufacturer : / Model No. : / 2.5. Modifications No modifications were implemented to meet testing criteria. Report No:TREE1406015201 Page 6 of 32 3. TEST ENVIRONMENT 3.1. Address of the test laboratory Shenzhen Huatongwei International Inspection Co., Ltd. Keji Nan No.12 Road, Hi-tech Park, Shenzhen, China Phone: 86-755-26748019 Fax: 86-755-26748089 3.2. Test Facility The test facility is recogn…

Text truncated - open the document above for the full version.

Test Setup Photos

Report 5. Tes No : TREE 1 st Setup 1406015201 p Photo os of the Radiated Radiate e EUT d Emission (B d Emission ( Below 30MH (Above 1GHz Hz) z) P age 29 of 333

Contact Information

Applicant

jianhao yang(emgineer)
[email protected]+86-0660-3380070Fax: +86-0660-3380377

Technical Contact

Truly Instrument Ltd.Jianhao Yang
[email protected]0660-3380070

Truly Industrial Area,Shanwei City, · Shanwei · China

Test Firm

Shenzhen Huatongwei International Insp. Co., LtdMoffy Yu
[email protected]86-755-26748078Fax: 86-755-26748089

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz100.00 µW
Confidentiality
Long Term
Grant Notes
Power Output listed is conducted. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Truly Instrument Ltd.

Blood Glucose / Cholesterol 2 in 1 Monitoring System - FCC ID 2ABG7-TBG-460 - Truly Instrument Ltd.
2ABG7-TBG-460

Blood Glucose / Cholesterol 2 in 1 Monitoring System

Aug 25, 2015

Equipment Class

DTS - Digital Transmission System
2ABG7TET-381

Infrared Thermometer

Aug 17, 2014

Equipment Class

DTS - Digital Transmission System
2ABG7TET-380

Infrared Thermometer

Aug 17, 2014

Equipment Class

DTS - Digital Transmission System
Infrared Ear & Forehead Thermometer - FCC ID 2ABG7-TET351 - Truly Instrument Ltd.
2ABG7-TET351

Infrared Ear & Forehead Thermometer

Jan 21, 2014

Equipment Class

DTS - Digital Transmission System
Infrared Ear & Forehead Thermometer - FCC ID 2ABG7-TET350 - Truly Instrument Ltd.
2ABG7-TET350

Infrared Ear & Forehead Thermometer

Jan 21, 2014

Equipment Class

DTS - Digital Transmission System