FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Essity Hygiene and Health AB/
  3. 2ABK3IDENTIFI

2ABK3IDENTIFIMoisture Detector

Essity Hygiene and Health AB
Moisture Detector - FCC ID 2ABK3IDENTIFI - Essity Hygiene and Health AB
Click to zoom

Application Details

Equipment Class
PCT - PCS Licensed Transmitter worn on body
Date of Grant
Aug 07, 2014
Application Purpose
Original Equipment
Date of Application
Aug 07, 2014
Equipment Note
Moisture Detector
Frequency Range
1712.40000000 - 1752.60000000
Company
Essity Hygiene and Health AB
Country
Sweden

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Parts List/Tune Up Info

↗
↗

RF Exposure Info

↗
↗
↗
↗
↗
↗

Test Report

↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Handling of incontinence protection and logger:                                                                                                                                                      Administrate assessment, 72 h:          !                  "                    !    "                                          !    #                         TENA Identi" e-Assessment TENA Identi" e-Assessment Cleaning the logger: #                               $       %                      $  70 % 70 %  &                 '                             &                                                           !  ( %                                  %                %           ) *                                        + , - . / Charging the logger:              #                         !      0                               #     User manual e-Assessmen t Prot ec tion with C onnec tor LoggerChar ger with C able Ligh t indica tion while in assessmen t pr ot ec tion: Ligh t indica tion while in char ger unit: e-Assessmen t Li

Cover Letter(s)

- CONFIDENTIAL – DISCLOSED UNDER NDA - Nemko AS Institutttveien 6 PO Box 96, N‐2007 Kjeller, Norway To Whom it may concern Subject : Authorisation letter Dear Sir/Madame: Telit Communication SpA declares of being the certification holder of the module type HE910‐D. This module is installed in the product Fat Track logger, model 61407, that our customer SCA HYGIENE PRODUCTS AB, Backstensgatan 5, SE‐40503, Gøteborg, Swedenwould, would like to certify. We authorize Nemko AS to refer to the documentation used for the approval for FCC/IC (FCC ID: RI7HE910, IC ID: 5131A‐HE910) Should you have any queries, please do not hesitate to contact us. Best regards ____________________________ Marco Contento Manager, Product Management EMEA

ID Label/Location Info

SCA HYGIENE PRODUCTS AB Made in Norway Use only with charger unit 61408 Bäckstensgatan 5 SE-431 49 Mölndal Sweden 61407 00201 Identity: B01 FCC ID: 2ABK3IDENTIFI Model: 61407 IC: 10866A-61407

Parts List/Tune Up Info

ANT-GXE474 Page 1 of 9 Version 1.0 Author: Harald Naumann Date: 01.04.2009 Round Solutions GmbH & Co KG Tel +49 6103 270440 Fax +49 6103 27044199 [email protected] wwww.roundsolutions.com Embedded GSM /UMTS antenna ANT-GXE474 Multiband SMD antenna on 24 mm x 5.5 mm x 4.4 mm only The ANT-GXE474 multiband cellular antenna builds on the success of several SMD tri-band antennas, by extending functionality to cover all worldwide cellular bands between 800 MHz and 2200 MHz – GSM, CDMA, DCS, PCS, WCDMA, UMTS, HSPA, GPRS and EDGE. This IFA antenna is particularly suited for mounting on the edge of a PCB. It measures 24 mm x 5.5 mm x 4.4 mm and is delivered on tape and reel for efficient and accurate assembly. If tuning is required it can be tuned for the device environment with no need for new tooling. The antenna is robust enough to meet all temperature and mechanical specifications required for automotive environments. Typical applications include automotive, remote monitoring, M2M, telematics, telemedicine, AVL, utility metering, mobile devices, point-of- sale, navigation, location based services and communication products. 1 Mechanical specification Electrode Silver Dimensions in mm (L x W x H) 24.0 x 5.5 x 4.4 Operating Temperature -35 ~ +85 Unit: mm Tolerance 0.15 mm ANT-GXE474 Page 2 of 9 Version 1.0 Author: Harald Naumann Date: 01.04.2009 Round Solutions GmbH & Co KG Tel +49 6103 270440 Fax +49 6103 27044199 [email protected] wwww.roundsolutions.com 2 Electrical Specifications Item GSM850/900 GSM 1800 GSM 1900 UMTS 2100 Frequency 824 ~ 960 MHz 1710 ~ 1850 MHz 1850 ~ 1990 MHz 1920 ~ 2170 MHz VSWR 3.0 : 1 max. 3.0 : 1 max. 3.0 : 1 max. 3.0 : 1 max. Peak Gain 1.5 dBi 3.5 dBi 3.5 dBi 3.5 dBi Eff. [%] @ min. 50% 70% 60% 60% Polarization Linear Radiation Pattern Omni-directional Nominal Impedance 50 Ohm Ground plane size 106 mm x 45 mm Matching tuning Tuning by changed ground plane / matching circuit as option These values are measured on the matched reference test board version a. Item GSM850/900 GSM 1800 GSM 1900 UMTS 2100 Frequency 824 ~ 960 MHz 1710 ~ 1850 MHz 1850 ~ 1990 MHz 1920 ~ 2170 MHz VSWR 3.0 : 1 max. 3.0 : 1 max. 3.0 : 1 max. 3.0 : 1 max. Peak Gain 1.5 dBi 3.5 dBi 3.5 dBi 3.5 dBi Eff. [%] @ min. 60% 77% 71% 55% Polarization Linear Radiation Pattern Omni-directional Nominal Impedance 50 Ohm Ground plane size 100.5 mm x 45 mm Matching tuning Matching circuit as opton These values are measured on the matched reference test board version b. ANT-GXE474 Page 3 of 9 Version 1.0 Author: Harald Naumann Date: 01.04.2009 Round Solutions GmbH & Co KG Tel +49 6103 270440 Fax +49 6103 27044199 [email protected] wwww.roundsolutions.com 3 Measurement Set for measurement with test board version a. Board size: 114x45mm Antenna Radiation the coordinate system [X axis: the axis of rotation] 3.1 Electrical Characteristic Antenna matching on the reference test board version a. S11(Return loss & VSWR) Quad Band (GSM850, DCS, PCS, UMTS) ANT-GXE474 Page 4 of 9 Version 1.0 Author: Harald Naumann Date: 01.04.2009 Round Solutions GmbH & Co KG Tel +49 6103 270440 Fax +49 6103 27044199 [email protected] wwww.roundsolutions.com 4 Radiation Characteristic Measurement setup ,6 m x 3 m x 3 m Anechoic Chamber, Matching on the standard test board (114 mm x 45 mm) ,Temperature 25 ºC / Humidity 50~55% EGSM (GSM850) DCS (GSM1800) PCS (GSM1900) ANT-GXE474 Page 5 of 9 Version 1.0 Author: Harald Naumann Date: 01.04.2009 Round Solutions GmbH & Co KG Tel +49 6103 270440 Fax +49 6103 27044199 [email protected] wwww.roundsolutions.com UMTS (WCDMA2100) ANT-GXE474 Page 6 of 9 Version 1.0 Author: Harald Naumann Date: 01.04.2009 Round Solutions GmbH & Co KG Tel +49 6103 270440 Fax +49 6103 27044199 [email protected] wwww.roundsolutions.com 5 Soldering recommendations 5.1 Soldering Land Pattern A 25 B 5.5 C 2.3 D 20.4 E 1.8 F 1.9 5.2 Placing of antenna and free space version a 114 ANT-GXE474 Page 7 of 9 Version 1.0 Author: Harald Naumann Date: 01.04.2009 Round Solutions GmbH & Co KG Tel +49 6103 270440 Fax +49 6103 27044199 [email protected] wwww.roundsolutions.com 6 Gain pattern measurement data ANT-GXE474 Page 8 of 9 Version 1.0 Author: Harald Naumann Date: 01.04.2009 Round Solutions GmbH & Co KG Tel +49 6103 270440 Fax +49 6103 27044199 [email protected] wwww.roundsolutions.com ANT-GXE474 Page 9 of 9 Version 1.0 Author: Harald Naumann Date: 01.04.2009 Round Solutions GmbH & Co KG Tel +49 6103 270440 Fax +49 6103 27044199 [email protected] wwww.roundsolutions.com 7 Soldering recommendations 7.1 Soldering Land Pattern A 25 B 5.5 C 2.3 D 20.4 E 1.8 F 1.9 7.2 Placing of antenna and free space version b Homebl_indented_titlebl_item_object_typebl_config_stringbl_rev_release_status_listbl_sequence_nobl_part_sourcebl_uombl_ref_designatorbl_all_notesbl_variant_statebl_rev_has_variantsbl_variant_conditionbl_is_occ_configuredbl_has_date_effectivitybl_rev_checked_outfnd0bl_has_active_markup 2 169182/ rev 09-CoverItemWorking( )30eachUG NAME,UG ENTITY HANDLE,UG REF SETYY 3 1159088/rev 4-PBA Logger MainItemWorking( )50eachUG NAME,UG ENTITY HANDLEYY 6 169288/rev 01-Battery Li-ion PL-603048-10CItemWorking( )70eachUG NAME,UG ENTITY HANDLE,UG REF SETYY 11 169349/rev 01-Housing with connectorpadsItemWorking( )100eachUG NAME,UG ENTITY HANDLEYY 12 169178/rev 03-Connector-pad x 12ItemWorking( )10eachPacked NotesYY 13 169175/rev 13-HousingItemWorking( )20eachUG NAME,UG REF SET,UG ENTITY HANDLEYY 14 169350/rev 01-Loctite Super Glue IDH 304018 x 26ItemWorking( )30eachPacked NotesYY 15 169351/rev 01-3M UMHW Polyethylene Tape 5423ItemWorking( )30eachPacked NotesYY Capture CIS Standard Bill Of Materials - Standard separate line per part Report Created on Friday Jan 04 10:58:18 2013 Title = SCHEMATIC SCA Fast Track Logger 3G RevCode = 4 Doc = SCH159093 SCA Fast Track Logger 3G Part ReferenceQuantityValueDescriptionAMLFarnellDigi-Key A11PCB1159093 REV 4PCB ANT11GXE474Round Solutions GmbH & Co KG C1168uCAP…

Text truncated - open the document above for the full version.

RF Exposure Info

SAR_Report_Nemko_60320_6130027_FCC_Body_850_1900_WCDMA2_4_SCA_V7 Page 1 of 37 The Testcenter facility ‘Dosimetric Test Lab’ within IMST GmbH is accredited by the German National ‘Deutsche Akkreditierungsstelle GmbH (DAkkS)’ for testing according to the scope as listed in the accreditation certificate: D-PL-12139-01-00. Report Dosimetric Assessment of the Portable Device TENA Identifi Logger from SCA Hygiene Products (FCC ID: 2ABK3IDENTIFI) (IC: IC-10866A-61407) According to the FCC Requirements August 05, 2014 IMST GmbH Carl-Friedrich-Gauß-Str. 2 D-47475 Kamp-Lintfort Customer SCA Hygiene Products AB SE-838 80 Hackas Sweden This revised version of the report supersede all previous version. The test results only relate to the items tested. This report shall not be reproduced except in full without the written approval of the testing laboratory. Executive Summary Dasy_Report_ FCC_Body_Card_850_1900_WCDMA II_WCDMA V_1.4.doc/20.06.2008/ABo SAR_Report_Nemko_60320_6130027_FCC_Body_850_1900_WCDMA2_4_SCA_V7 Page 2 of 37 Dasy_Report_ FCC_Body_Card_850_1900_WCDMA II_WCDMA V_1.4.doc/20.06.2008/ABo The TENA Identifi Logger is a new device from SCA Hygiene Products working as humidity monitoring system in a medical product, operating in the 850 MHz, 1700 MHz and 1900 MHz frequency range. The device has an integrated antenna and the system concepts used are the GPRS/EDGE 850, GPRS/EDGE 1900, WCDMA I (FDD), WCDMA II (FDD) and WCDMA IV (FDD) standards. There is no simultaneous transmission mode available. The objective of the measurements done by IMST was the dosimetric assessment of one device in body worn configuration in the GPRS 850 (Class 12), GPRS 1900 (Class 12), WCDMA II (FDD) and WCDMA IV (FDD) standards. The measurements were performed in use case scenario in combination with a diaper below the flat part of the SAM phantom. The examinations have been carried out with the dosimetric assessment system „DASY4“. The measurements were made according to the Supplement C to OET Bulletin 65 of the Federal Communications Commission (FCC) Guidelines [OET 65] for evaluating compliance of mobile and portable devices with FCC limits for human exposure (general population) to radiofrequency emissions and IC RSS 102 Issue 4. Additional information and guidelines given by the following FCC documents were used:  SAR Measurement Requirements for 100 MHz to 6 GHz [KDB 865664 D01 v01]  Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies [KDB 447498 D01 v05]  SAR Measurement Procedures for 3G Devices [KDB 941225 D01 v02]  Recommended SAR Test Reduction Procedures for GSM/GPRS/EDGE [KDB 941225 D03 v01]  SAR Guidance for HSPA, HSPA+, DC-HSDPA and 1x-Advance [KDB 941225 D02 and 1x Advanced v02r02] All measurements have been performed in accordance to the recommendations given by SPEAG. SAR_Report_Nemko_60320_6130027_FCC_Body_850_1900_WCDMA2_4_SCA_V7 Page 3 of 37 Dasy_Report_ FCC_Body_Card_850_1900_WCDMA II_WCDMA V_1.4.doc/20.06.2008/ABo Compliance Statement According Manufacturer information the device transmits data for max. 60 seconds every 20 minutes. In a 6 minute exposure time this results a duty factor of 16.6 %. The portable device TENA Identifi Logger from SCA Hygiene Products (FCC ID: 2ABK3IDENTIFI, IC: IC-10866A-61407) is in compliance with the IC RSS 102 Issue 4 [RSS 102] and Federal Communications Commission (FCC) Guidelines [OET 65] for uncontrolled exposure. SAR assessment in body worn was conducted in use case scenario in combination with a diaper with a distance of 0 mm between the housing of the device and the flat phantom. The maximum results of SAR for the TENA Identifi Logger are as follows: Test Position Frequency Band Channel Position Highest Reported SAR 1g [W/kg] (Measured) Highest Reported SAR 1g [W/kg] (duty factor 16.6%) Body Worn GPRS 850 (4TX) 190 1 (Fig. 13) 0.139 0.023 GPRS 1900 (4TX) 810 1.134 0.188 WCDMA II (FDD) 512 0.744 0.124 WCDMA IV (FDD) 1312 0.679 0.113 prepared by: .............................................. reviewed by: .............................................. Alexander Rahn André van den Bosch test engineer quality assurance engineer SAR_Report_Nemko_60320_6130027_FCC_Body_850_1900_WCDMA2_4_SCA_V7 Page 4 of 37 Dasy_Report_ FCC_Body_Card_850_1900_WCDMA II_WCDMA V_1.4.doc/20.06.2008/ABo Table of Contents 1 SUBJECT OF INVESTIGATION ..........................................................................................................5 2 THE IEEE STANDARD C95.1 AND THE FCC EXPOSURE CRITERIA .............................................5 2.1 DISTINCTION BETWEEN EXPOSED POPULATION, DURATION OF EXPOSURE AND FREQUENCIES ...........6 2.2 DISTINCTION BETWEEN MAXIMUM PERMISSIBLE EXPOSURE AND SAR LIMITS ....................................6 2.3 GENERAL SAR LIMIT ......................................................................................................................7 3 THE FCC MEASUREMENT PROCEDURE .........................................................................................7 3.1 GENERAL REQUIREMENTS...............................................................................................................7 3.2 TESTS FOR MODULES IN PORTABLE DEVICES ACCORDING KDB 941225 ...........................................8 3.3 TESTS IN BODY WORN CONFIGURATION ACCORDING KDB 447498 ...................................................9 3.4 MEASUREMENT VARIABILITY ............................................................................................................9 4 THE MEASUREMENT SYSTEM ....................................................................................................... 10 4.1 PHANTOMS .................................................................................................................................. 11 4.2 E-FIELD-PROBES ......................................................................................................................... 12 4.3 MEASUREMENT PROCEDURE .........…

Text truncated - open the document above for the full version.

RF Exposure Info

The Testcenter facility ‘Dosimetric Test Lab’ within IMST GmbH is accredited by the German National ‘Deutsche Akkreditierungsstelle GmbH (DAkkS)’ for testing according to the scope as listed in the accreditation certificate: D-PL-12139-01-01. SAR_Report_Nemko_60320_6130027_FCC_Body_850_1900_WCDMA2_4_Plots_SCA_V2 Page 1 of 6 Appendix for the Report Dosimetric Assessment of the Portable Device SCA Humidity Logger from Prevas (FCC ID: 2ABK3IDENTIFI) (IC: IC-10866A-61407) According to the FCC Requirements SAR Distribution Plots June 27, 2013 IMST GmbH Carl-Friedrich-Gauß-Str. 2 D-47475 Kamp-Lintfort Customer SCA Hygiene Products AB SE-838 80 Hackas Sweden This revised version of the report supersede all previous version. The test results only relate to the items tested. This report shall not be reproduced except in full without the written approval of the testing laboratory. SAR_Report_Nemko_60320_6130027_FCC_Body_850_1900_WCDMA2_4_Plots_SCA_V2 Page 2 of 6 dasy_report_fcc_850_1900_plots_1.1.doc/04.07.2005/CH Table of Contents SAR DISTRIBUTION PLOTS, GPRS 850 BODY ................................................................................................. 3 1 SAR DISTRIBUTION PLOTS, GPRS 1900 BODY ..................................................................................... 4 2 SAR DISTRIBUTION PLOTS, WCDMA FDD II BODY .............................................................................. 5 3 SAR DISTRIBUTION PLOTS, WCDMA FDD IV BODY ............................................................................ 6 SAR_Report_Nemko_60320_6130027_FCC_Body_850_1900_WCDMA2_4_Plots_SCA_V2 Page 3 of 6 dasy_report_fcc_850_1900_plots_1.1.doc/04.07.2005/CH SAR Distribution Plots, GPRS 850 Body Test Laboratory: Imst GmbH, DASY Yellow (II); File Name: SCA_340_yahm_1.da4 DUT: SCA Humidity Logger; Serial: 351579050121340 Program Name: GPRS 850 (Class 12) Communication System: GPRS 850; Frequency: 836.6 MHz;Duty Cycle: 1:2 Medium parameters used: f = 836.6 MHz; σ = 1 mho/m; ε r = 56.5; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY4 Configuration: - Probe: ET3DV6R - SN1579; ConvF(6.24, 6.24, 6.24); Calibrated: 25.01.2012 - Sensor-Surface: 4mm (Mechanical Surface Detection) - Electronics: DAE4 Sn631; Calibrated: 20.09.2012 - Phantom: SAM Sugar 1341; Type: QD 000 P40 CB; Serial: TP-1341 - Measurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 186 Body/Area Scan (9x8x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.118 mW/g Body/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 6.56 V/m; Power Drift = -0.185 dB Peak SAR (extrapolated) = 0.251 W/kg SAR(1 g) = 0.101 mW/g; SAR(10 g) = 0.048 mW/g Maximum value of SAR (measured) = 0.117 mW/g Fig. 1: SAR distribution for GPRS 850 (Class 12), channel 190, Position 1, (January 23, 2013; Ambient Temperature: 21.5°C; Liquid Temperature: 21.3°C). SAR_Report_Nemko_60320_6130027_FCC_Body_850_1900_WCDMA2_4_Plots_SCA_V2 Page 4 of 6 dasy_report_fcc_850_1900_plots_1.1.doc/04.07.2005/CH 1 SAR Distribution Plots, GPRS 1900 Body Test Laboratory: Imst GmbH, DASY Yellow (II); File Name: SCA_340_yphh_1.da4 DUT: SCA Humidity Logger; Serial: 351579050121340 Program Name: GPRS 1900 (Class 12) Communication System: GPRS 1900; Frequency: 1909.8 MHz;Duty Cycle: 1:2 Medium parameters used: f = 1909.8 MHz; σ = 1.58 mho/m; ε r = 53.9; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY4 Configuration: - Probe: EX3DV4 - SN3536; ConvF(8.4, 8.4, 8.4); Calibrated: 24.09.2012 - Sensor-Surface: 4mm (Mechanical Surface Detection) - Electronics: DAE3 Sn335; Calibrated: 20.02.2012 - Phantom: SAM Glycol 1340; Type: QD 000 P40 CB; Serial: TP-1340 - Measurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 186 Body/Area Scan (11x11x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 0.780 mW/g Body/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 18.4 V/m; Power Drift = -0.069 dB Peak SAR (extrapolated) = 1.41 W/kg SAR(1 g) = 0.749 mW/g; SAR(10 g) = 0.408 mW/g Maximum value of SAR (measured) = 0.836 mW/g Fig. 2: SAR distribution for GPRS 1900 (Class 12), channel 810, Position 1 (January 18, 2013; Ambient Temperature: 21.7°C; Liquid Temperature: 21.6°C). SAR_Report_Nemko_60320_6130027_FCC_Body_850_1900_WCDMA2_4_Plots_SCA_V2 Page 5 of 6 dasy_report_fcc_850_1900_plots_1.1.doc/04.07.2005/CH 2 SAR Distribution Plots, WCDMA FDD II Body Test Laboratory: Imst GmbH, DASY Yellow (II); File Name: SCA_340_yuIIhl_1.da4 DUT: SCA Humidity Logger; Serial: 351579050121340 Program Name: WCDMA II (FDD) Communication System: WCDMA FDD Band II; Frequency: 1852.4 MHz;Duty Cycle: 1:1 Medium parameters used (interpolated): f = 1852.4 MHz; σ = 1.46 mho/m; ε r = 53.7; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY4 Configuration: - Probe: EX3DV4 - SN3536; ConvF(8.4, 8.4, 8.4); Calibrated: 24.09.2012 - Sensor-Surface: 4mm (Mechanical Surface Detection) - Electronics: DAE3 Sn335; Calibrated: 20.02.2012 - Phantom: SAM Glycol 1340; Type: QD 000 P40 CB; Serial: TP-1340 - Measurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 186 Body/Area Scan (11x11x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 0.623 mW/g Body/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 16.7 V/m; Power Drift = 0.093 dB Peak SAR (extrapolated) = 1.01 W/kg SAR(1 g) = 0.619 mW/g; SAR(10 g) = 0.353 mW/g Maximum value of SAR (measured) = 0.685 mW/g Fig. 3: SAR distribution for WCDMA II, channel 9262, Position 1 (January 17, 2013; Ambient Temperature: 21.8°C; Liquid Temperature: 21.6°C). SAR_Report_Nemko_60320_6130027_FCC_Body_850_1900_WCDMA2_4_Plots_SCA_V2 Page 6 of 6 dasy_report_fcc_850_1900_plots_1.1.doc/04.07.2005/CH 3 SAR Distribution Plots, WCDMA FDD IV Body Test Laboratory: Imst GmbH, DASY Yellow (II); File Name: SCA_340_yuIVhl_1.da4 DUT: SCA Humidity Logger; Serial: 351579050121340 Program Name: W…

Text truncated - open the document above for the full version.

RF Exposure Info

The Testcenter facility ‘Dosimetric Test Lab’ within IMST GmbH is accredited by the German National ‘Deutsche Akkreditierungsstelle GmbH (DAkkS)’ for testing according to the scope as listed in the accreditation certificate: D-PL-12139-01-01. SAR_Report_Nemko_60320_6130027_FCC_CalData_SCA_V4 SAR_Report__CalData_1.0.doc/05.08.2011/AR Appendix for the Report Dosimetric Assessment of the Portable Device SCA Humidity Logger from Prevas (FCC ID: 2ABK3IDENTIFI) (IC: IC-10866A-61407) According to the FCC Requirements Calibration Data June 27, 2013 IMST GmbH Carl-Friedrich-Gauß-Str. 2 D-47475 Kamp-Lintfort Customer SCA Hygiene Products AB SE-838 80 Hackas Sweden This revised version of the report supersede all previous version. The Testcenter facility ‘Dosimetric Test Lab’ within IMST GmbH is accredited by the German National ‘Deutsche Akkreditierungsstelle GmbH (DAkkS)’ for testing according to the scope as listed in the accreditation certificate: D-PL-12139-01-01. Cal_D835V2_SN437_0412 Page 1 of 7 Calibration Certificate Certificate No: Cal_D835V2_SN437_0412 Object: D835V2 SN: 437 Date of Calibration: April 19, 2012 Next Calibration: April 2014 Object Condition: In Tolerance Calibration Equipment used: Test Equipment Serial Number Last calibration Calibrated by Next calibration Powermeter E4416A GB41050414 Nov 10 Rohde&Schwarz (200954-D-K-15012- 01-00-2010-11) Nov 12 Power Sensor E9301H US40010212 Nov 10 Rohde&Schwarz (200944-D-K-15012- 01-00-2010-11) Nov 12 Powermeter E4417A GB41050441 Nov 10 Rohde&Schwarz (200952-D-K-15012- 01-00-2010-11) Nov 12 Power Sensor E9301A MY41495584 Nov 10 Rohde&Schwarz (200953-D-K-15012- 01-00-2010-11) Nov 12 Network Analyzer E5071C MY46103220 Aug 11 Agilent (1-3503689015-1) Aug 13 Reference Probe EX3DV4 SN 1579 Jan 12 SPEAG No ET3-1579_Jan12 Jan 13 DAE4 SN 335 Feb 12 SPEAG No DAE3-335_Feb12 Feb 13 Cal_D835V2_SN437_0412 Page 2 of 7 Calibration is performed according the following standards: IEEE 1528-2003 "IEEE Recommended Practice for Determining the Peak Spatial - Averaged Specific Absorption Rate (SAR) in the Human Head from Wireless Communication Devices: Measurement Technique", December 2003 IEC 62209-1 "Procedure to measure the Specific Absorption Rate (SAR) for hand - held devices used in close proximity to the ear (frequency range of 300 MHz to 3GHz)", February 2005 IEC 62209-2 "Evaluation of Human Exposure to Radio Frequency Fields from Handheld and Body-Mounted Wireless Communication Devices in the Frequency Range of 30 MHz to 6 GHz: Human models, Instrumentation, and Procedures ", Part 2: “Procedure to determine the Specific Absorption Rate (SAR) for including accessories and multiple transmitters” Edition 1.0, 2010-01 Federal Communications Commission Office of Engineering & Technologies (FCCOET) "Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields; Additional Information for Evaluating Compliance of Mobile and Portable Devices with FCC Limits for Human Exposure to Radiofrequency Emissions", Supplement C (Edition 01-01) to Bulletin 65 Additional Documentation: DASY 4/5 System Handbook prepared by: reviewed by: Alexander Rahn André van den Bosch test engineer quality assurance engineer 08 Cal_D835V2_SN437_0412 Page 3 of 7 Measurement Conditions DASY Version: Dasy 4; V4.7 Phantom: SAM Phantom 1059/1341 Distance Dipole Center – TSL: 15mm With spacer Area Scan resolution dx, dy = 15 mm Zoom Scan resolution dx, dy, dz = 5mm Frequency: 835 MHz ± 1MHz Head TSL Parameters at 835 MHz Temperature Permittivity Conductivity Nominal Head TSL Parameters 22.0 41.50 0.90 Measured Head TSL Parameters 21.1 40.90 ± 6% 0.91 S/m ± 6% SAR Result with Head TSL at 835 MHz Averaged over 1g SAR measured 250 mW input power 2.58 mW/g SAR normalized normalized to 1W 10.32 mW/g SAR for nominal Head TSL parameters normalized to 1W 10.21 mW/g ± 16.5 % (k=2) Averaged over 10g SAR measured 250 mW input power 1.69 mW/g SAR normalized normalized to 1W 6.78 mW/g SAR for nominal Head TSL parameters normalized to 1W 6.73 mW/g ± 16.5 % (k=2) Cal_D835V2_SN437_0412 Page 4 of 7 Body TSL Parameters at 835 MHz Temperature Permittivity Conductivity Nominal Body TSL Parameters 22.0 55.20 0.97 Measured Body TSL Parameters 21.8 54.50 ± 6% 0.99 S/m ± 6% SAR Result with Body TSL at 835 MHz Averaged over 1g SAR measured 250 mW input power 2.51 mW/g SAR normalized normalized to 1W 10.04 mW/g SAR for nominal Body TSL parameters normalized to 1W 9.86 mW/g ± 16.5 % (k=2) Averaged over 10g SAR measured 250 mW input power 1.64 mW/g SAR normalized normalized to 1W 6.56 mW/g SAR for nominal Body TSL parameters normalized to 1W 6.47 mW/g ± 16.5 % (k=2) General Antenna Parameters at 835 MHz Antenna Parameters with Head TSL Impedance, transformed to feed point 43.8 Ω – 4.58 jΩ Return Loss -21.76 dB Antenna Parameter with Body TSL Impedance, transformed to feed point 45.9 Ω - 6.72 jΩ Return Loss -21.77 dB After long term use with 100W radiated power, only a slight warming of the dipole near the feedpoint can be measured. The dipole is made of standard semigrid coaxial cable. The center conductor of the feeding line is directly connected to the second arm of the dipole. The antenna is therefore short-circuited for DC signals. Additional EUT Data Manufactured by: SPEAG Manufactured on: December 15, 2000 Cal_D835V2_SN437_0412 Page 5 of 7 SAR Result with Head TSL at 835 MHz Test Laboratory: Imst GmbH, DASY Yellow (II); File Name: 190412_y_1579.da4 DUT: Dipole 835 MHz SN437; Type: D835V2; Serial: D835V2 - SN:437 Program Name: System Performance Check at 835 MHz Communication System: CW; Frequency: 835 MHz;Duty Cycle: 1:1 Medium parameters used: f = 835 MHz; σ = 0.91 mho/m; ε r = 40.9; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY4 Configuration: - Probe: ET3DV6R - SN1579; ConvF(6.34, 6.34, 6.34); Calibrated: 25.01.2012 - Sensor-Surface: 4mm (Mechanical Surface Detection) - Electronics: DAE3 Sn335; Calibrated: 20.02.2012 - Phantom: SAM Sugar 1341; Type: QD 000 P40 CB…

Text truncated - open the document above for the full version.

RF Exposure Info

SAR_Report_Nemko_60320_6140239_FCC_Body_WCDMA5_SCA_V2 Page 1 of 27 The Testcenter facility ‘Dosimetric Test Lab’ within IMST GmbH is accredited by the German National ‘Deutsche Akkreditierungsstelle GmbH (DAkkS)’ for testing according to the scope as listed in the accreditation certificate: D-PL-12139-01-00. Supplementary Report Dosimetric Assessment of the Portable Device TENA Identifi Logger from SCA Hygiene Products (FCC ID: 2ABK3IDENTIFI) (IC: IC-10866A-61407) According to the FCC Requirements July 08, 2014 IMST GmbH Carl-Friedrich-Gauß-Str. 2 D-47475 Kamp-Lintfort Customer SCA Hygiene Products AB SE-838 80 Hackas Sweden This revised version of the report supersede all previous version. The test results only relate to the items tested. This report shall not be reproduced except in full without the written approval of the testing laboratory. Dasy_Report_ FCC_Body_Card_850_1900_WCDMA II_WCDMA V_1.4.doc/20.06.2008/ABo SAR_Report_Nemko_60320_6140239_FCC_Body_WCDMA5_SCA_V2 Page 2 of 27 Dasy_Report_ FCC_Body_Card_850_1900_WCDMA II_WCDMA V_1.4.doc/20.06.2008/ABo Executive Summary The TENA Identifi Logger is a new device from SCA Hygiene Products working as humidity monitoring system in a medical product, operating in the 850 MHz, 1700 MHz and 1900 MHz frequency range. The device has an integrated antenna and the system concepts used are the GPRS/EDGE 850, GPRS/EDGE 1900, WCDMA I (FDD), WCDMA II (FDD), WCDMA IV (FDD) and WCDMA V (FDD) standards. There is no simultaneous transmission mode available. This supplementary report is an appendix to the following report: SAR_Report_Nemko_60320_6130027_FCC_Body_850_1900_WCDMA2_4_SCA_V6 Issued on June 14, 2014. Therefore in this report only WCDMA V was assessed. The objective of the measurements done by IMST was the dosimetric assessment of one device in body worn configuration in the WCDMA V (FDD) standards. The measurements were performed in use case scenario in combination with a diaper below the flat part of the SAM phantom. The examinations have been carried out with the dosimetric assessment system „DASY4“. The measurements were made according to the 47 CFR § 2.1093 [47CFR] for evaluating compliance of mobile and portable devices with FCC limits for human exposure (general population) to radiofrequency emissions. Additional information and guidelines given by the following FCC documents were used:  SAR Measurement Requirements for 100 MHz to 6 GHz [KDB 865664 D01 v01r03]  Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies [KDB 447498 D01 v05r02]  SAR Measurement Procedures for 3G Devices [KDB 941225 D01 v02]  Recommended SAR Test Reduction Procedures for GSM/GPRS/EDGE [KDB 941225 D03 v01]  SAR Guidance for HSPA, HSPA+, DC-HSDPA and 1x-Advance [KDB 941225 D02 and 1x Advanced v02r02] All measurements have been performed in accordance to the recommendations given by SPEAG. SAR_Report_Nemko_60320_6140239_FCC_Body_WCDMA5_SCA_V2 Page 3 of 27 Dasy_Report_ FCC_Body_Card_850_1900_WCDMA II_WCDMA V_1.4.doc/20.06.2008/ABo Compliance Statement According manufacturer information the device transmits data for max. 60 seconds every 20 minutes. In a 6 minute exposure time this results a duty factor of 16.6 %. The portable device TENA Identifi Logger from SCA Hygiene Products (FCC ID: 2ABK3IDENTIFI, IC: IC-10866A-61407) is in compli…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Peter Blomstrom(Global Brand Director Emerging Arenas)
[email protected]46317460000Fax: 46317461900

Technical Contact

SCA Hygiene Products ABChrister Olofsson Ranta
[email protected]46317460124

Backstensgatan 5 · Gothenburg · Sweden

Test Firm

Nemko ASFrode Sveinsen
[email protected]47-22-96-03-35Fax: 47-22-96-05-50

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
7271.71 GHz - 1.75 GHz510.00 mW4M06F9W1 ppm
Confidentiality
Long Term
Grant Notes
Output power is ERP for part 22H and EIRP for parts 24E, 27. The highest reported SAR is 1.13 W/kg. This device contains functions that are not operational in U.S. Territories.

Other Applications from Essity Hygiene and Health AB

2ABK3-652929

Tork Automatic Soap and Sanitizer Dispenser IoT

Apr 23, 2026

Equipment Class

JAB - Part 15 Class B Digital Device
TENA Gateway for TENA IQ Solutions - FCC ID 2ABK3-91290 - Essity Hygiene and Health AB
2ABK3-91290

TENA Gateway for TENA IQ Solutions

Nov 03, 2020

Equipment Class

DTS - Digital Transmission System
Gateway for TENA IQ Solution - FCC ID 2ABK3-91285 - Essity Hygiene and Health AB
2ABK3-91285

Gateway for TENA IQ Solution

Sep 22, 2020

Equipment Class

JAB - Part 15 Class B Digital Device
The Tork EasyCube Data Colletion Unit (DCU) communicates via 2.4 GHz radio with the sensor units in the Tork EasyCube system and collects and filter data to be sent to a server via GSM network. - FCC ID 2ABK3-682860 - Essity Hygiene and Health AB
2ABK3-682860

The Tork EasyCube Data Colletion Unit (DCU) communicates via 2.4 GHz radio with the sensor units in the Tork EasyCube system and collects and filter data to be sent to a server via GSM network.

Sep 29, 2015

Equipment Class

DTS - Digital Transmission System
The Tork Foam Dispenser with Intuition Sensor has an embedded sensor with a radio component that forwards information on battery status and refill level to the Tork EasyCube  Data Collection Unit (DCU) via 2.4 GHz radio - FCC ID 2ABK3-682830 - Essity Hygiene and Health AB
2ABK3-682830

The Tork Foam Dispenser with Intuition Sensor has an embedded sensor with a radio component that forwards information on battery status and refill level to the Tork EasyCube Data Collection Unit (DCU) via 2.4 GHz radio

Sep 24, 2015

Equipment Class

DTS - Digital Transmission System