2ABS5-EWC-3000Wireless charger

HSM CO., LTD.
Wireless charger - FCC ID 2ABS5-EWC-3000 - HSM CO., LTD.
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Mar 05, 2014
Application Purpose
Original Equipment
Date of Application
Mar 05, 2014
Equipment Note
Wireless charger
Frequency Range
0.11000000 - 0.20500000
Company
HSM CO., LTD.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

One Touch Trigger Button Locks the device with just one touch LED Charge indicator Easy to view LED lets you know your device is charging Car USB Charging Port Car Micro USB charging port for added convenience Sticky Suction Pad Innovative pad that sticks to any surface Cushion Protects your device from scratches Adjust the height to meet the charger TX & Smartphone RX Bottom extendable bracket Rotatable mount for different viewing angles 360 ̊ Rotation Arms on 2 sides extend to open mount Extendable Arms Locks and loosens suction pad Locking Lever Adjusts bottom arm to accomodate different devices Bottom Bracket Release Button MODEL: EWC-3000 (Wireless Car Charging Mount) User Manual & Limited Warranty HSM Co., Ltd www.hsmtech.com EWC-3000 Includes, Product Overview EWC-3000User Manual & WarrantyCigar Charger (Option) How to use EWC-3000 1. Place EWC-3000 on where necessary and connect it to power source. * A. Powerful Gel Suction enables the unit to be used in wide area such as at home, at the office and even in the car staying on the textured dashboard tightly. B. When EWC-3000 is properly connected to power source, LED light turns to Orange 2. Place the phone on the unit. The Phone have to be equiped with ‘RECEIVER’ * Wireless charging Receiver is not included in the package * Extend the arms of the unit. Place your phone into mount and slightlly push to work ‘one touch button’ to lock. 3. If the unit placed properly, Green light turns on and flickers. If Orange light flickers, use ‘Bottom extendable bracket’ and move the phone up and down until the Green light turns on. When the ‘Bottom bracket release button’ is pushed, the ‘Bottom extendable bracket’ will be pulled up and down. 4. When fully charged, Green LED light stops flickering. * Check the charging status through charging icon on your smart phone. * Foreign material between the phone and charing mount or poorly adjusted ‘Bottom extendable bracket’ may block charging. LED Status IndicatorCharge status OrangeConnected to power source Orange flickersPhone is not installed to the mount properly, RX doesn’t meet TX Green flickersCharging GreenFully charged EWC-3000 properly acquired qi Certificate from WPC(Wireless Power Consortium) MODEL: EWC-3000 (Easy Flex One Touch Wireless Charging Mount) User Manual & Limited Warranty HSM Co., Ltd www.hsmtech.com 구 성 품 Safety Precautionst Limited Warranty Specification These saftey precasutions are for keeping users away from danger along with loss of property. Read these safety precautions before using EWC-3000. HSM takes no responsibilities for any injuries and damages caused by not following below notice. ▶ Do not install EWC-3000 on where interferes with driving. Avoid Gear, Handle, Brake, Airbag depolyment zone in the car ▶ Do not operate the unit during the driving. It may cause accident. ▶ Do not use broken power cords, plugs and loosened sockets. ▶ Do not touch plugs with wet hands or remove the power pulling cords with force. ▶ Do not bend the power cord with force. ▶ Do not place your unit near metal objects such as coins, keys, cell phones, jewelries. ▶ Charging battery process may cause heat. When heat get sever, stop charging the unit and cool it down. ▶ Touching overheated unit with bare hands can cause skin burn includes red rash and pigmentation on skin. ▶ Do not store or exposure your unit to flammable objects such as gas stoves, microwave oven or high pressure container. This can cause fire or accident ▶ Do not drop the unit or exposure it to external shock. ▶ Do not keep the unit on a sloped surface. This may cause damage to the unit or break components inside. ▶ Keep the unit away from small children or pet, not to be bitten or sucked. This may damage your unit or cause fire. ▶ Keep the unit in a dry circumstance. Prolonged exposure to moisture cuase damage to the parts and curcuit board. ▶ Use this unit for original purpose only. ▶ Do not disassemble, modify or repair the unit. It can cause electric shock. ▶ Limited warranty does not cover the unit which has unauthorized disassembling, modification ro repairs. HSM warrants this product and all parts thereof, only to the original end-user purchaser to be free from defective materials and workmanship for first twelve(12) months beginning on the date of purchase of the product. Customer center: 822-573-5466 The limited warranty does not cover, 1) Claims for loss of use/inconveniences due to any malfunction, damage caused by light- ing, water or other liquid intrusion, fire, flood, accident, negligence, misuse or improper handling/operation. 2) Product that has been damaged due to installation, repairs, alteration or modification by unauthorized service organization or person. 3) Defects or parts requiring replacement due to the ordinary wear and tear, corrosion rust or stains, scratches, dents on the casing or pair work of the products. This warranty covers only United States. FCC Compliance statements FCC compliance statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interfer…

Text truncated - open the document above for the full version.

Cover Letter(s)

HSM CO., LTD. 2F Yeong-jae Bldg., 40, Nonhyeon-ro 24gil, Gangnam-gu, Seoul, 135-855, Korea Phone: +82-2-573-5466 Fax: +82-2-573-4190 Date (18/02/2014) TUV SUD BABT Octagon House, Concorde Way, Segensworth North, Fareham, Hampshire, PO15 5RL, United Kingdom Dear Sir or Madam, We, HSM CO., LTD. : 2F Yeong-jae Bldg., 40, Nonhyeon-ro 24gil, Gangnam-gu, Seoul, 135-855, Korea hereby authorize Young-Joon, Park (CTK Co., Ltd. : (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea) to act as our agent in all matters relating to applications for equipment authorization, including the signing of all documents relating to these matters. This authorization expires on 18/02/2015. Sincerely, Company Officer: Gyu Gwang, Choi Telephone Number: +82-2-573-5466 Email: [email protected]

Cover Letter(s)

HSM CO., LTD. 2F Yeong-jae Bldg., 40, Nonhyeon-ro 24gil, Gangnam-gu, Seoul, 135-855, Korea Phone: +82-2-573-5466 Fax: +82-2-573-4190 Date (18/02/2014) TUV SUD BABT Octagon House, Concorde Way, Segensworth North, Fareham, Hampshire, PO15 5RL, United Kingdom Confidentiality Request FCC ID: 2ABS5-EWC-3000 Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commission’s Rules, HSM CO., LTD. hereby requests permanent confidential treatment of information accompanying this application as outlined below: Schematics Bill of Materials/Parts List PCB layout Block Diagrams Theory of Operation HSM CO., LTD. also hereby requests short-term confidential treatment of information accompanying this application as outlined below for a period of 0 day: [Common exhibits for which short-term confidentiality is requested are: Internal Photos External Photos User Manual Test Set-up Photographs The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. Yours sincerely, Company Officer: Gyu Gwang, Choi Telephone Number: +82-2-573-5466 Email: [email protected]

Cover Letter(s)

FCC Home | Search | RSS | Updates | E-Filing | Initiatives | Consumers | Find People From:[email protected] To:[email protected] Subject:Response to Inquiry to FCC (Tracking Number 892127) Date:19 February 2014 13:24:37 Office of Engineering and Technology Inquiry on 02/05/2014 : Inquiry: Seeking guidance for wireless chargers : Attached FCC response on 02/06/2014 Please review KDB 680106 DO1 and clarify if the EUT meets all the criteria outlined in Section 5(2) of this publication. KDB 680106 D01 is linked below. http://appsint.fcc.gov/kdb/GetAttachment.html?id=gDJO4az8eyw84%2BgyujPd%2Bw%3D%3D ---Reply from Customer on 02/18/2014--- Attached operational description and RF Exposure test report. Please check and reply. Thanks. FCC response on 02/18/2014 Based upon the information provided, this device would not meet the criteria described under KDB 680106 D01 Paragraph 5(2) due to the maximum coupling surface area being less than 60cm 2 . Due to this, an RF exposure evaluation must be reviewed and accepted through a KDB or PBA inquiry to enable authorization of the device. The report submitted partially meets these criteria. However, field measurements are not shown from all sides/top as discussed in Paragraph 3(3) of said KDB publication. Please ensure that the submitted test results are in accordance with Paragraph 3(3) of KDB 680106 D01. ---Reply from Customer on 02/19/2014--- Attached RF Exposure test report update. (Page 9 and Page 11) (Measurements was made from all sides andthe top of the primary/client pair, with the 10 cm measured from the center ofthe probe(s) to the edge of the device. The highest emission level was recorded.) Please check and reply. Thanks. FCC response on 02/19/2014 Based upon the information provided, this EUT may be processed according to normal procedures by a TCB, if certification is required; or a recognized laboratory, if Declaration of Conformity is appropriate. Attachment Details: Do not reply to this message. Please select the Reply to an Inquiry Response link from the OET Inquiry System to add any additional information pertaining to this inquiry.

External Photos

CTK Co., Ltd. 386-1, Ho-dong, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-339-9855 www.e-ctk.com Page 1 of 3 EUT External Photos CTK Co., Ltd. 386-1, Ho-dong, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-339-9855 www.e-ctk.com Page 2 of 3 CTK Co., Ltd. 386-1, Ho-dong, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-339-9855 www.e-ctk.com Page 3 of 3

ID Label/Location Info

CTK Co., Ltd. 386-1, Ho-dong, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-339-9855 www.e-ctk.com Page 1 of 1 EUT Label Photos

Internal Photos

CTK Co., Ltd. 386-1, Ho-dong, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-339-9855 www.e-ctk.com Page 1 of 3 EUT Internal Photos CTK Co., Ltd. 386-1, Ho-dong, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-339-9855 www.e-ctk.com Page 2 of 3 CTK Co., Ltd. 386-1, Ho-dong, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-339-9855 www.e-ctk.com Page 3 of 3

RF Exposure Info

CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Test Report No.: CTK-2014-00185-1 Date: February 19, 2014 Page 1 of 12 This Report shall not be reproduced except in full without the written approval of CTK Form No.: CTK-RF-EF-Part15 Subpart C(Rev.1) RF EXPOSURE REPORT According to : FCC 47CFR part 1 subpart I and part 2 subpart J KDB Inquiry : Tracking Number 892127 Test Report No. : CTK-2014-00185-1 Date of Issue : February 19, 2014 FCC ID : 2ABS5-EWC-3000 Equipment Under Test : EWC-3000 Kind of Product : Wireless Car Charging Mount Applicant : HSM CO., LTD. Applicant Address : 2F Yeong-jae Bldg., 40, Nonhyeon-ro 24gil, Gangnam-gu, Seoul, 135-855, Korea Manufacturer : HSM CO., LTD. Manufacturer Address : 2F Yeong-jae Bldg., 40, Nonhyeon-ro 24gil, Gangnam-gu, Seoul, 135-855, Korea Contact Person : Gyu Gwang, Choi / Project Manager Telephone : +82-2-573-5466 Received Date : February 7, 2014 Test period : Start : February 7, 2014 End : February 18, 2014 Test Results : In Compliance Not in Compliance The test results presented in this report relate only to the object tested. Tested by Reviewed by Young-taek Lee Test Engineer Young-Joon, Park Technical Manager Date: February 19, 2014 Date: February 19, 2014 CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Test Report No.: CTK-2014-00185-1 Date: February 19, 2014 Page 2 of 12 This Report shall not be reproduced except in full without the written approval of CTK Form No.: CTK-RF-EF-Part15 Subpart C(Rev.1) REPORT REVISION HISTORY Date Revision Page No February 19, 2014 Issued (CTK-2014-00185-1) All February 19, 2014 Issued (CTK-2014-00185-1) Update Test Setup and Test Results All This report shall not be reproduced except in full, without the written approval of CTK Co., Ltd. This document may be altered or revised by CTK Co., Ltd. personnel only, and shall be noted in the revision section of the document. Any alteration of this document not carried out by CTK Co., Ltd. will constitute fraud and shall nullify the document. CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Test Report No.: CTK-2014-00185-1 Date: February 19, 2014 Page 3 of 12 This Report shall not be reproduced except in full without the written approval of CTK Form No.: CTK-RF-EF-Part15 Subpart C(Rev.1) TABLE OF CONTENTS REPORT REVISION HISTORY .......................................................................................... 2 1.0 General Product Description ............................................................................... 4 1.1 Model Differences ............................................................................................. 4 1.2 Device Modifications ......................................................................................... 4 1.3 Peripheral Devices ............................................................................................ 4 1.4 EUT Operating Modes ........................................................................................ 5 1.5 Test Modes ...................................................................................................... 5 1.6 Calibration Details of Equipment Used for Measurement ......................................... 7 1.7 Test Facility...................................................................................................... 7 1.8 Laboratory Accreditations and Listings ................................................................. 7 2.0 Summary of tests ............................................................................................. 8 2.1 Test Setup ....................................................................................................... 9 2.2 Radio frequency radiation exposure limits .......................................................... 10 2.3 Test Results ................................................................................................... 11 APPENDIX A – Test Equipment Used For Tests ................................................................ 12 CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Test Report No.: CTK-2014-00185-1 Date: February 19, 2014 Page 4 of 12 This Report shall not be reproduced except in full without the written approval of CTK Form No.: CTK-RF-EF-Part15 Subpart C(Rev.1) 1.0 General Product Description Type of equipment Wireless Car Charging Mount Equipment model name EWC-3000 Frequency Range 110 kHz – 205 kHz Antenna type Coil antenna Coil Specification Outer diameter : 43.0 mm ± 1.0 mm Inner diameter : 20.5 mm ± 0.5 mm Number of turns : 10 Power Source CAR ADAPTER Input : DC 12 V - 24 V Output : DC 5 V, 2.0 A Test Voltage and Frequency : DC 5 V, - 1.1 Model Differences Not applicable 1.2 Device Modifications The following modifications were necessary for compliance: Not applicable 1.3 Peripheral Devices Device Manufacturer Model No. Serial No. FCC ID or DoC CAR ADAPTER HAEM Co., Ltd. ECA-P10XBK DW1D521DS/B-E - Te s t J i g S-MOBILE TECH CO., LTD. - - - Wireless Charging Cover OPENTECH Inc. OWC-300R - - Wireless Charging Cover RFTech Co., Ltd. EBC-1G6WWERT0C802AS/4-E - Mobile Phone Samsung Electronics Co., Ltd. SCH-I535 - A3LSCHI535 CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Test Report No.: CTK-2014-00185-1 Date: February 19, 2014 Page 5 of 12 This Report shall not be reproduced except in full without the written approval of CTK Form No.: CTK-RF-EF-Part15 Subpart C(Rev.1) 1.4 EUT Operating Modes Equipment under test was operated during the measurement under the following conditions: Charging and communication mode Modulation Type : CW (Continuou…

Text truncated - open the document above for the full version.

Test Report

CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Test Report No.: CTK-2014-00184-1 Date: March 4, 2014 Page 1 of 19 This Report shall not be reproduced except in full without the written approval of CTK Form No.: CTK-RF-EF-Part15 Subpart C(Rev.1) TEST REPORT According to : FCC 47CFR part 15 subpart C Test Report No. : CTK-2014-00184-1 Date of Issue : March 4, 2014 FCC ID : 2ABS5-EWC-3000 Equipment Under Test : EWC-3000 Kind of Product : Wireless Car Charging Mount Applicant : HSM CO., LTD. Applicant Address : 2F Yeong-jae Bldg., 40, Nonhyeon-ro 24gil, Gangnam-gu, Seoul, 135-855, Korea Manufacturer : HSM CO., LTD. Manufacturer Address : 2F Yeong-jae Bldg., 40, Nonhyeon-ro 24gil, Gangnam-gu, Seoul, 135-855, Korea Contact Person : Gyu Gwang, Choi / Project Manager Telephone : +82-2-573-5466 Received Date : February 7, 2014 Test period : Start : February 7, 2014 End : February 18, 2014 Test Results : In Compliance Not in Compliance The test results presented in this report relate only to the object tested. Tested by Reviewed by Young-taek Lee Test Engineer Young-Joon, Park Technical Manager Date: March 4, 2014 Date: March 4, 2014 CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Test Report No.: CTK-2014-00184-1 Date: March 4, 2014 Page 2 of 19 This Report shall not be reproduced except in full without the written approval of CTK Form No.: CTK-RF-EF-Part15 Subpart C(Rev.1) REPORT REVISION HISTORY Date Revision Page No February 18, 2014 Issued (CTK-2014-00184) All March 4, 2014 Issued (CTK-2014-00184-1) Update Summary of tests All This report shall not be reproduced except in full, without the written approval of CTK Co., Ltd. This document may be altered or revised by CTK Co., Ltd. personnel only, and shall be noted in the revision section of the document. Any alteration of this document not carried out by CTK Co., Ltd. will constitute fraud and shall nullify the document. CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Test Report No.: CTK-2014-00184-1 Date: March 4, 2014 Page 3 of 19 This Report shall not be reproduced except in full without the written approval of CTK Form No.: CTK-RF-EF-Part15 Subpart C(Rev.1) TABLE OF CONTENTS REPORT REVISION HISTORY .......................................................................................... 2 1.0 General Product Description ............................................................................... 4 1.1 Model Differences ............................................................................................. 4 1.2 Device Modifications ......................................................................................... 4 1.3 Peripheral Devices ............................................................................................ 4 1.4 EUT Operating Modes ........................................................................................ 5 1.5 Test Modes ...................................................................................................... 5 1.6 Calibration Details of Equipment Used for Measurement ......................................... 7 1.7 Test Facility...................................................................................................... 7 1.8 Laboratory Accreditations and Listings ................................................................. 7 2.0 Summary of tests ............................................................................................. 8 2.1 Power line conducted emissions (Section 15.207) .................................................. 9 2.2 Radiated emissions (Section 15.209) ................................................................. 10 APPENDIX A – Test Equipment Used For Tests ................................................................ 19 CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Test Report No.: CTK-2014-00184-1 Date: March 4, 2014 Page 4 of 19 This Report shall not be reproduced except in full without the written approval of CTK Form No.: CTK-RF-EF-Part15 Subpart C(Rev.1) 1.0 General Product Description Type of equipment Wireless Car Charging Mount Equipment model name EWC-3000 Frequency Range 110 kHz – 205 kHz Antenna type Coil antenna Power Source CAR ADAPTER Input : DC 12 V - 24 V Output : DC 5 V, 2.0 A Test Voltage and Frequency : DC 5 V, - 1.1 Model Differences Not applicable 1.2 Device Modifications The following modifications were necessary for compliance: Not applicable 1.3 Peripheral Devices Device Manufacturer Model No. Serial No. FCC ID or DoC CAR ADAPTER HAEM Co., Ltd. ECA-P10XBK DW1D521DS/B-E - Te s t J i g S-MOBILE TECH CO., LTD. - - - Wireless Charging Cover OPENTECH Inc. OWC-300R - - Wireless Charging Cover RFTech Co., Ltd. EBC-1G6WWERT0C802AS/4-E - Mobile Phone Samsung Electronics Co., Ltd. SCH-I535 - A3LSCHI535 CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Test Report No.: CTK-2014-00184-1 Date: March 4, 2014 Page 5 of 19 This Report shall not be reproduced except in full without the written approval of CTK Form No.: CTK-RF-EF-Part15 Subpart C(Rev.1) 1.4 EUT Operating Modes Equipment under test was operated during the measurement under the following conditions: Charging and communication mode Modulation Type : CW (Continuous Wave) Output Power : Max. 10.48 dBuV/m (Frequency 115.4 kHz, Test Distance 3 m) TX Duty Cycle : 100 % by measurement 1.5 Test Modes This device has been tested below conditions: [Test Mode #1] Frequency Charging current Note 110 kHz 1 A Low Frequency, Max. Load 157.5 kHz 650 mA Middle Frequency, Medium Load 205 kHz 250 mA High Frequency, Min. Load This…

Text truncated - open the document above for the full version.

Test Setup Photos

CTK Co., Ltd. 386-1, Ho-dong, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-339-9855 www.e-ctk.com Page 1 of 7 Test Setup Photos Conducted Voltage Emissions CTK Co., Ltd. 386-1, Ho-dong, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-339-9855 www.e-ctk.com Page 2 of 7 Radiated Electric Field Emissions [Test Mode #1] CTK Co., Ltd. 386-1, Ho-dong, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-339-9855 www.e-ctk.com Page 3 of 7 CTK Co., Ltd. 386-1, Ho-dong, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-339-9855 www.e-ctk.com Page 4 of 7 Radiated Electric Field Emissions [Test Mode #2] CTK Co., Ltd. 386-1, Ho-dong, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-339-9855 www.e-ctk.com Page 5 of 7 CTK Co., Ltd. 386-1, Ho-dong, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-339-9855 www.e-ctk.com Page 6 of 7 RF Exposure [Test Mode #1] CTK Co., Ltd. 386-1, Ho-dong, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-339-9855 www.e-ctk.com Page 7 of 7 RF Exposure [Test Mode #2]

Contact Information

Applicant

Gyu Gwang Choi(Representative)
[email protected]+82-2-573-5466Fax: +82-2-573-4190

Test Firm

CTK Co., Ltd.Young-Joon Park
[email protected]82-31-339-9871Fax: 82-31-624-9501

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.11 MHz - 0.205 MHz-
Confidentiality
Long Term

Other Applications from HSM CO., LTD.

Easy One Touch 4 Wireless - FCC ID 2ABS5-HLCRIO135 - HSM CO., LTD.
2ABS5-HLCRIO135

Easy One Touch 4 Wireless

Apr 11, 2021

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Wireless charger - FCC ID 2ABS5-EWC-4000 - HSM CO., LTD.
2ABS5-EWC-4000

Wireless charger

Feb 26, 2015

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz