Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Mar 20, 2014
Application Purpose
Original Equipment
Date of Application
Mar 20, 2014
Equipment Note
RFID Reader
Frequency Range
13.55300000 - 13.56700000
Company
Monarch International Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Page1Rev 0.95a03122014 AJW RFID Logger Software User Manual Rev 0.95 Table of Contents 1.System Overview.....................................................................................................................................................................2 2.Installation...............................................................................................................................................................................2 3.USB RFIDInterface Box............................................................................................................................................................3 4.Operation................................................................................................................................................................................4 4.1.Start Up..........................................................................................................................................................................4 4.2.Menu overview..............................................................................................................................................................4 4.2.1.File menu...................................................................................................................................................................4 4.2.2.Device Menu..............................................................................................................................................................5 4.2.3.Preferences................................................................................................................................................................5 4.2.4.Advanced Preferences...............................................................................................................................................5 4.2.5.Help...........................................................................................................................................................................5 4.3.Quick Load Icons............................................................................................................................................................6 5.TABS.........................................................................................................................................................................................7 5.1.GRAPH TAB....................................................................................................................................................................7 5.1.1.Icons..........................................................................................................................................................................7 5.1.2.Displaying Recorded Data..........................................................................................................................................8 5.2.DATA TABLE TAB............................................................................................................................................................9 5.2.1.Synchronizing Data....................................................................................................................................................9 5.2.2.Exporting Table Data...............................................................................................................................................10 5.2.3.Printing Table Data..................................................................................................................................................10 5.3.DEVICE SETUP TAB.......................................................................................................................................................10 5.3.1.General Tab.............................................................................................................................................................10 5.3.2.Alarms Tab...............................................................................................................................................................12 6.RFID Interface Box Specification...........................................................................................................................................13 6.1.Specifications...............................................................................................................................................................13 6.2.FCC Statement.............................................................................................................................................................13 Page2Rev 0.95a03122014 AJW 1.System Overview It is important that you read this manual completely and follow all safetyprecautions before operating this instrument. • This device is notintendedfor use in any medical or nuclear application. •This device is not intended for usein flammable or explosive environments. •Do notoperate with a power source other than the one recommended in thismanual. • Do not operate this device outside of the recommendationsin thismanual. TheRFID Logger softwareis used in conjunction with the RFID Interface Box(part number5396- 9920 shown right)to read and write information from passive Near Field Communication (NFC) RFID Track-Its ). The interface box isa peripheral accessory that plugs into the USB port on a PC or Laptop. The tags can also be read using the NFC capability of certain mobile smart phones and Tablets. There is software available for Android TM devices on theGoogle Play TM Store– refer to theANDROID RFID LOGGER APPLICATION USER GUIDEorRFID LOGGER QUICK START GUIDEfor further information.Full details on the Track-It RFID Loggers is available inonlineand theRFID LOGGER USER MANUAL. The RFID Logger Softwareand manuals can be downloaded from: http://www.monarchinstrument.com/Software/Track-It_RFID_…

Text truncated - open the document above for the full version.

Cover Letter(s)

February 18 th , 2014 Federal Communications Commission Office of Engineering and Technology 7435 Oakland Mills Road Columbia, MD 21046 Dear Sir, We Monarch Instrument respectfully request that the schematic diagrams, block diagram and circuit description submitted with this application for Certification be withheld from public disclosure pursuant to Sections 0.457 (d) and 0.459 and of the FCC Rules. This request is made under the provisions of Section 0.552 (b) (4) of the Freedom of Information Act. The items listed above contain trade secrets and proprietary information which if disclosed to the public may be harmful to the applicant and place Monarch Instrument at a competitive disadvantage. Thank you for your attention to this matter. Sincerely, Alan Woolfson Vice President - Engineering 15 Columbia Drive, Amherst, NH 03031 Phone: 603-883-3390 Fax: 603-886-3300 Web: www.monarchinstrument.com Email: [email protected]

Cover Letter(s)

Retlif Testing Laboratories 101 New Boston Road Goffstown, NH 03045 Attn: Scott Wentworth Ref: AGENT AUTHORIZATION/ANTI-DRUG ABUSE CERTIFICATION Dear Scott, Monarch International Inc.dba Monarch Instrument hereby authorizes Retlif Testing Laboratories, 101 New Boston Road, Goffstown, NH 03045 to act as our agent in all matters pertaining to FCC Certification of our RFID Interface Box Model Monarch Instrument (The Applicant) Certifies that neither Monarch Instrument nor any party to the application is subject to denial of Federal benefits, that include FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862 because of a conviction for possession or distribution of a controlled substance. See 47CFR 1.2002(b) for the definition of a “party” for these purposes. Sincerely, Alan Woolfson Vice President - Engineering 15 Columbia Drive, Amherst, NH 03031 Phone: 603-883-3390 Fax: 603-886-3300 Web: www.monarchinstrument.com Email: [email protected]

ID Label/Location Info

Label – FC Size: Material: Colors: PLACEM E CC Product La 1.5” x Broth e 2, Bla ENT OF LABEL abel for RFID 1.5” er Polyester L ck printing on L – Bottom Su Reader 5396 Laminate UL- n White backg urface as show 6-9920 969 Complia n ground wn nt

Test Report

We certify the equip made in a Retlif Test Scott Wen Branch M NVLAP A Todd Ha n Laborator iNARTE C Non-Warranty The testing se principles and Non-Endorse m This test repor not intended to used by the cli y that this r ment stated accordance ting Labora ntworth anage r pproved Si nnemann ry Superviso Certified Te y Provision ervices have bee practices. This w ment rt contains only f o constitute a rec ent to claim prod C report is a t d. We furth e with the p atories pers gnatory or chnician AT en performed, fin warranty is in lieu indings and resu commendation, e duct endorsemen Pa Certificatio true repres her certify t procedures sonnel takin TL-0255-T ndings obtained u of all others, eit ults arrived at afte endorsement or nt by NVLAP or a R ge 2 of 33 on and Sig sentation of hat the me s indicated ng them. and reports pre ther expressed o er employing the certification of th any agency of the Retl natures f the results easurement and vouch epared in accord or implied. e specific test pro he product or ma e U.S. Governm lif Testing Repor s obtained ts shown in h for the qu dance with gene ocedures and sta aterial tested. Th ent. g Labora rt No. R-5 from the te n this repor ualifications erally accepted l andards listed he his test report mu atories 5812N ests of rt were s of all laboratory erein. It is ust not be Retlif Testing Laboratories R Report No. R-5812N Page 3 of 33 Technical Information Report Number: R-5812N Applicant: Monarch International, Inc. dba Monarch Instrument 15 Columbia Drive Amherst, NH 03031 Manufacturer: Monarch Instrument Test Sample: RFID Reader Part Number: N/A Model Number: RFID-RDR Serial Numbers: Beta-002, Beta-001 (Frequency Tolerance only) Brand Name: Monarch Instrument Power Requirements: 5 VDC Frequency of Operation: 13.56 MHz Equipment Use: RFID Tag Reader Test Specification: FCC Rules and Regulations Part 15, Subpart C, Section 15.225 and 15.209 Test Procedure: ANSI C63.4:2003 EUT Description/Installation: The RFID Reader is used to read and write information from passive Near Field Communication (NFC) tags (RFID Track – Its). The reader is a peripheral accessory that plugs into the USB port on a PC or laptop to enable the tags to be read by the user. The tags can also be read using the NFC capability of certain mobile smart phones. Retlif Testing Laboratories R Report No. R-5812N Page 4 of 33 EUT Description/Installation (continued) The RFID Reader is built around the ST micro CR95HF which is an integrated transceiver IC for contactless applications. The CD95HF manages frame coding and decoding in Reader Mode for standard applications such as NFC, proximity and vicinity standards. The CR95HF embeds an Analog Front End to provide the 13.56 MHz Air Interface. Tests Performed The test methods performed on the RFID Reader are shown below: FCC Part 15, Subpart C Test Method 15.255(a) Field Strength of Fundamental 15.225(b)(c)(d) and 15.209 Field Strength of Spurious, Out of Band/Band Edge Emissions 15.225(e) Frequency Tolerance 15.207(a) Conducted Emissions, 150 kHz to 30 MHz Support Equipment The EUT was tested while connected to the USB port of a Laptop Computer System. The following support equipment was used during testing: Description Manufacturer Model Number Serial Number Laptop Computer Samsung Series 9 N/A Laptop Computer Dell PP05L CN-0X2034-48643-41E- 0420 Mouse Dell N/A N/A Monitor Dell E197FPF CN-OWM319-72872- 698-281L Ethernet Switch Linksys EZXS55W R9150H443962 General Test Requirements 1. The measurement procedures of ANSI C63.4:2003 were utilized as specified in FCC Part 15, Subpart C, Section 15.31(a)(3). 2. All measurements were performed at a 3 meter test distance. 3. The EUT was rotated throughout 360 degrees for all radiated emissions measurements as specified in FCC Section 15.31(f)(5). 4. All readily accessible EUT controls were adjusted in such a manner as to maximize the level of emissions in accordance with FCC Section 15.31(g). 5. Appropriate accessories were attached to all EUT ports during the performance of radiated emissions measurements as required by FCC Section 15.31(i). Retlif Testing Laboratories R Report No. R-5812N Page 5 of 33 Requirements and Test Results Requirement: FCC Section 15.225 (a) Field Strength of Fundamental FCC Section 15.225(a) – The field strength of any emission within the band 13.553 MHz – 13.567 MHz shall not exceed 15,848 microvolts/meter at 30 meters. Field Strength Measurement & Calculation: The following spectrum analyzer settings were used: RBW = 1 MHz for f ≥ 1 GHz, 100 kHz for f ≤ 1 GHz VBW ≥ RBW Detector Function = Peak or Average as applicable Trace = Max Hold Sweep = Auto The maximized field strength of the emission was calculated as follows: F C = M R + C F Where: F C = Corrected Field Strength Reading in dBμV/m M R = Uncorrected Meter Reading in dBμV C F = Correction Factor in dB (Pre-Amp + Antenna Factor + Cable Loss + Distance Factor) For frequencies below 30 MHz a distance factor of -40dB/decade was utilized Retlif Testing Laboratories R Report No. R-5812N Page 6 of 33 Requirements and Test Results (con’t) 15.225 (a) Field Strength of Fundamental Radiated Emissions Measurement Procedure: The field strength of the fundamental emission was measured with a spectrum analyzer or EMI Receiver. The EUT was placed on an 80cm high wooden test stand located 3 meters from the test antenna on a FCC listed open area test site. Emissions from the EUT were maximized by re-orientating the test sample, rotating the test sample 360 degrees, changing the orientation of the receive antenna and raising and lowering the test antenna from 1 – 4 meters. The maximized field strength of each observed emission was measured, recorded and compared to the specified limits of 15.225(a) as appropriate.  Results: The maximized measured field strength of the fundamental emission was below the specified test limit of 15.225(a). See test data. Requirement: FCC Section 15.225 (b) - The field strength of any emission …

Text truncated - open the document above for the full version.

Test Setup Photos

Retlif Testing Laboratories R Report No. R-5812N Page 10 of 33 Test Photograph(s) Field Strength of Fundamental FCC Part 15, Subpart C, Section 15.225(a) Retlif Testing Laboratories R Report No. R-5812N Page 11 of 33 Test Photograph(s) Field Strength of Fundamental Test Setup, OATS, 9 kHz to 30 MHz Test Configuration

Contact Information

Applicant

Alan Woolfson(VP Engineering)
[email protected]603-883-3390Fax: 603-883-3310

Technical Contact

Retlif Testing LaboratoriesScott Wentworth
[email protected]6034974600

101 New Boston Rd. · Goffstown, New Hampshire · United States

Non-Technical Contact

Retlif Testing LaboratoriesScott Wentworth
[email protected]6034974600

Test Firm

Retlif Testing LaboratoriesScott Wentworth
[email protected]603-497-4600Fax: 603-497-5281

Technical Specifications

#Rule PartsFrequency RangePower Output
115C13.553 MHz - 13.567 MHz-
Confidentiality
Long Term