2ABTAHNL85A1ZAutomatic Upper Arm Blood Pressure Monitor

Health & Life Co., Ltd.
Automatic Upper Arm Blood Pressure Monitor - FCC ID 2ABTAHNL85A1Z - Health & Life Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 31, 2021
Application Purpose
Original Equipment
Date of Application
Jan 28, 2021
Equipment Note
Automatic Upper Arm Blood Pressure Monitor
Frequency Range
2402.00000000 - 2480.00000000
Company
Health & Life Co., Ltd.
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 Manual Automatic Upper Arm Blood Pressure Monitor Model No. HL858A1-Z 2 Medical Disclaimer Table of Contents Medical Disclaimer.......................................................................................03 Intended Use...............................................................................................03 About Blood Pressure.................................................................................04 Precautions....................................................................................................06 Device Overview...........................................................................................08 Symbol Definitions.....................................................................................09 Features.........................................................................................................11 Bluetooth Transmission............................................................................14 Installing Batteries.....................................................................................16 Using the adapter............................................................................17 Applying the Cuff........................................................................................18 Measurement Procedure..........................................................................19 Memory Function........................................................................................22 Storage and Maintenance.........................................................................23 Troubleshooting...........................................................................................24 Limited Warranty........................................................................................26 Specifications..............................................................................................27 Note..............................................................................................................29 Appendix........................................................................................................31 Blood Pressure Diary.................................................................................34 3 Medical Disclaimer Medical Disclaimer This manual and product are not meant as a substitute for advice provided by your doctor. You are not to use the information contained herein, or this product for diagnosing or treating a health problem or prescribing any medication. If you have or suspect that you have a medical problem, promptly consult your healthcare provider. HL858A1-Z automatically measures human’s Systolic, Diastolic blood pressure and heart rate by using the oscillometric method during inflation. All values can be read out in one LCD panel. Measurement position is at human being’s upper arm. The intended use of this over-the-counter device is for adults aged 18 years and older with arm circumference ranging from 9 inches to 17 inches (approx.23 cm to 43 cm) and for home use. HL858A1-Z detects the appearance of irregular heartbeats during measurement; an indicated symbol will appear with measuring reading. And the BP Category Indicator will show the information with the readings on the screen for the user tracking their blood pressure level. Besides, the device features a built-in "Bluetooth Transmission" function, which enables the device automatically transmit measuring results to paired Bluetooth-enabled device. Also, users could simply synchronize the current date and time, and check the battery status of blood pressure monitor by means of DailyChek® application software with the paired Bluetooth-enabled device. Intended Use 4 1. What is blood pressure? Blood pressure is the measurement of the force of blood pushing against the walls of the arteries. Arterial blood pressure is constantly fluctuating during the course of the cardiac cycle. The highest pressure in the cycle is called the systolic blood pressure, and represents the pressure in the artery when the heart is beating. The lowest pressure is the diastolic blood pressure, and represents the pressure in the artery when the heart is at rest. Both the systolic and the diastolic pressure are necessary for a physician to evaluate the status of a patient's blood pressure. Many factors such as physical activity, anxiety or the time of day, can influence your blood pressure. Blood pressure is typically low in the mornings and increases from the afternoon to the evening. It is on average lower in the summer and higher in the winter. 2. Why is it useful to measure blood pressure at home? Having one's blood pressure measured by a doctor in a hospital or a clinic, is often associated with a phenomenon called “White Coat Hypertension” where the patient becomes nervous or anxious, thus raising his blood pressure. There are also numerous other factors that might cause your blood pressure to be raised at a specific time of day. This is why medical practitioners recommend home monitoring as it is important to get readings of blood pressure during different times of the day to really get an idea of your real blood pressure. Medical practitioners generally recommend the “Rule of 3”, where you are encouraged to take your blood pressure three times in a row (at 3 ~ 5 minute interval), three times a day for three days. After three days you can average all the results and this will give you an accurate idea of what your blood pressure really is. About Blood Pressure 5 About Blood Pressure A. WHO blood pressure classifications: Standards for assessment of high or low blood pressure without regard to age, have been established by the World Health Organization (WHO), as shown in the chart. However this chart is not exact for classification of blood pressure and it's intended to be used as a guide in understanding non-invasive blood pressure measurements. Please consult with your physician for proper diagnosis. B. Variations i…

Text truncated - open the document above for the full version.

External Photos

Report No.: 2090889R-E3032110108 Page: 1 of 13 Attachment 2 : EUT Detailed Photographs (1) EUT Photo (HL858A1-Z (DC -Jack)) (2) EUT Photo (HL858A1-Z (DC -Jack)) Report No.: 2090889R-E3032110108 Page: 2 of 13 (3) EUT Photo (HL858A1-Z (DC -Jack)) (4) EUT Photo (HL858A1-Z (DC -Jack)) Report No.: 2090889R-E3032110108 Page: 3 of 13 (5) EUT Photo (HL858A1-Z (DC -Jack)) (6) EUT Photo (HL858A1-Z (DC -Jack)) Report No.: 2090889R-E3032110108 Page: 4 of 13 (7) EUT Photo (HL858A1-Z (DC -Jack)) (8) EUT Photo (HL858A1-Z (micro USB)) Report No.: 2090889R-E3032110108 Page: 5 of 13 (9) EUT Photo (HL858A1-Z (micro USB)) (10) EUT Photo (HL858A1-Z (micro USB)) Report No.: 2090889R-E3032110108 Page: 6 of 13 (11) EUT Photo (HL858A1-Z (micro USB)) (12) EUT Photo (HL858A1-Z (micro USB)) Report No.: 2090889R-E3032110108 Page: 7 of 13 (13) EUT Photo (HL858A1-Z (micro USB)) (14) EUT Photo (HL858A1-Z (type C)) Report No.: 2090889R-E3032110108 Page: 8 of 13 (15) EUT Photo (HL858A1-Z (type C)) (16) EUT Photo (HL858A1-Z (type C)) Report No.: 2090889R-E3032110108 Page: 9 of 13 (17) EUT Photo (HL858A1-Z (type C)) (18) EUT Photo (HL858A1-Z (type C)) Report No.: 2090889R-E3032110108 Page: 10 of 13 (19) EUT Photo (HL858A1-Z (type C)) (20) EUT Photo (HL858CB) Report No.: 2090889R-E3032110108 Page: 11 of 13 (21) EUT Photo (HL858CB) (22) EUT Photo (HL858CB) Report No.: 2090889R-E3032110108 Page: 12 of 13 (23) EUT Photo (HL858CB) (24) EUT Photo (HL858CB) Report No.: 2090889R-E3032110108 Page: 13 of 13 (25) EUT Photo (HL858CB)

ID Label/Location Info

Health & Life Co. Ltd. FCC ID: 2ABTAHNL85A1Z 9F., No. 186, Jian Yi Road, Zhonghe District, New Taipei City, Taiwan TEL: +886-2-8227-1300 FCC ID Label

ID Label/Location Info

Health & Life Co. Ltd. FCC ID: 2ABTAHNL85A1Z 9F., No. 186, Jian Yi Road, Zhonghe District, New Taipei City, Taiwan TEL: +886-2-8227-1300 The FCC ID will be placed on the equipment as shown in the photograph below.

Internal Photos

Report No.: 2090889R-E3032110108 Page: 1 of 36 Attachment 2 : EUT Detailed Photographs (1) EUT Photo (HL858A1-Z (DC -Jack)) (2) EUT Photo (HL858A1-Z (DC -Jack)) Report No.: 2090889R-E3032110108 Page: 2 of 36 (3) EUT Photo (HL858A1-Z (DC -Jack)) (4) EUT Photo (HL858A1-Z (DC -Jack)) Report No.: 2090889R-E3032110108 Page: 3 of 36 (5) EUT Photo (HL858A1-Z (DC -Jack)) (6) EUT Photo (HL858A1-Z (DC -Jack)) Report No.: 2090889R-E3032110108 Page: 4 of 36 (7) EUT Photo (HL858A1-Z (DC -Jack)) (8) EUT Photo (HL858A1-Z (DC -Jack)) Report No.: 2090889R-E3032110108 Page: 5 of 36 (9) EUT Photo (HL858A1-Z (DC -Jack)) (10) EUT Photo (HL858A1-Z (DC -Jack)) Report No.: 2090889R-E3032110108 Page: 6 of 36 (11) EUT Photo (HL858A1-Z (DC -Jack)) (12) EUT Photo (HL858A1-Z (DC -Jack)) Report No.: 2090889R-E3032110108 Page: 7 of 36 (13) EUT Photo (HL858A1-Z (DC -Jack)) (14) EUT Photo (HL858A1-Z (DC -Jack)) Antenna RF Chip Report No.: 2090889R-E3032110108 Page: 8 of 36 (15) EUT Photo (HL858A1-Z (DC -Jack)) (16) EUT Photo (HL858A1-Z (DC -Jack)) Report No.: 2090889R-E3032110108 Page: 9 of 36 (17) EUT Photo (HL858A1-Z (DC -Jack)) (18) EUT Photo (HL858A1-Z (DC -Jack)) Report No.: 2090889R-E3032110108 Page: 10 of 36 (19) EUT Photo (HL858A1-Z (DC -Jack)) (20) EUT Photo (HL858A1-Z (DC -Jack)) Report No.: 2090889R-E3032110108 Page: 11 of 36 (21) EUT Photo (HL858A1-Z (DC -Jack)) (22) EUT Photo (HL858A1-Z (DC -Jack)) Report No.: 2090889R-E3032110108 Page: 12 of 36 (23) EUT Photo (HL858A1-Z (DC -Jack)) (24) EUT Photo (HL858A1-Z (DC -Jack)) Report No.: 2090889R-E3032110108 Page: 13 of 36 (25) EUT Photo (HL858A1-Z (DC -Jack)) (26) EUT Photo (HL858A1-Z (DC -Jack)) Report No.: 2090889R-E3032110108 Page: 14 of 36 (27) EUT Photo (HL858A1-Z (micro USB)) (28) EUT Photo (HL858A1-Z (micro USB)) Report No.: 2090889R-E3032110108 Page: 15 of 36 (29) EUT Photo (HL858A1-Z (micro USB)) (30) EUT Photo (HL858A1-Z (micro USB)) Report No.: 2090889R-E3032110108 Page: 16 of 36 (31) EUT Photo (HL858A1-Z (micro USB)) (32) EUT Photo (HL858A1-Z (micro USB)) Report No.: 2090889R-E3032110108 Page: 17 of 36 (33) EUT Photo (HL858A1-Z (micro USB)) (34) EUT Photo (HL858A1-Z (micro USB)) Report No.: 2090889R-E3032110108 Page: 18 of 36 (35) EUT Photo (HL858A1-Z (micro USB)) (36) EUT Photo (HL858A1-Z (micro USB)) Report No.: 2090889R-E3032110108 Page: 19 of 36 (37) EUT Photo (HL858A1-Z (micro USB)) (38) EUT Photo (HL858A1-Z (micro USB)) Report No.: 2090889R-E3032110108 Page: 20 of 36 (39) EUT Photo (HL858A1-Z (micro USB)) (40) EUT Photo (HL858A1-Z (micro USB)) Antenna RF Chip Report No.: 2090889R-E3032110108 Page: 21 of 36 (41) EUT Photo (HL858A1-Z (micro USB)) (42) EUT Photo (HL858A1-Z (micro USB)) Report No.: 2090889R-E3032110108 Page: 22 of 36 (43) EUT Photo (HL858A1-Z (micro USB)) (44) EUT Photo (HL858A1-Z (micro USB)) Report No.: 2090889R-E3032110108 Page: 23 of 36 (45) EUT Photo (HL858A1-Z (micro USB)) (46) EUT Photo (HL858A1-Z (micro USB)) Report No.: 2090889R-E3032110108 Page: 24 of 36 (47) EUT Photo (HL858A1-Z (micro USB)) (48) EUT Photo (HL858A1-Z (micro USB)) Report No.: 2090889R-E3032110108 Page: 25 of 36 (49) EUT Photo (HL858A1-Z (micro USB)) (50) EUT Photo (HL858A1-Z (type C)) Report No.: 2090889R-E3032110108 Page: 26 of 36 (51) EUT Photo (HL858A1-Z (type C)) (52) EUT Photo (HL858A1-Z (type C)) Report No.: 2090889R-E3032110108 Page: 27 of 36 (53) EUT Photo (HL858A1-Z (type C)) (54) EUT Photo (HL858A1-Z (type C)) Report No.: 2090889R-E3032110108 Page: 28 of 36 (55) EUT Photo (HL858A1-Z (type C)) (56) EUT Photo (HL858A1-Z (type C)) Report No.: 2090889R-E3032110108 Page: 29 of 36 (57) EUT Photo (HL858A1-Z (type C)) (58) EUT Photo (HL858A1-Z (type C)) Report No.: 2090889R-E3032110108 Page: 30 of 36 (59) EUT Photo (HL858A1-Z (type C)) (60) EUT Photo (HL858A1-Z (type C)) Report No.: 2090889R-E3032110108 Page: 31 of 36 (61) EUT Photo (HL858A1-Z (type C)) (62) EUT Photo (HL858A1-Z (type C)) RF Chip Antenna Report No.: 2090889R-E3032110108 Page: 32 of 36 (63) EUT Photo (HL858A1-Z (type C)) (64) EUT Photo (HL858A1-Z (type C)) Report No.: 2090889R-E3032110108 Page: 33 of 36 (65) EUT Photo (HL858A1-Z (type C)) (66) EUT Photo (HL858A1-Z (type C)) Report No.: 2090889R-E3032110108 Page: 34 of 36 (67) EUT Photo (HL858A1-Z (type C)) (68) EUT Photo (HL858A1-Z (type C)) Report No.: 2090889R-E3032110108 Page: 35 of 36 (69) EUT Photo (HL858A1-Z (type C)) (70) EUT Photo (HL858A1-Z (type C)) Report No.: 2090889R-E3032110108 Page: 36 of 36 (71) EUT Photo (HL858A1-Z (type C)) (72) EUT Photo (HL858A1-Z (type C))

RF Exposure Info

Report No.: 2090889R-E3082100014 Page: 1 of 5 RF Exposure Evaluation Report Product Name : Automatic Upper Arm Blood Pressure Monitor Model No. : HL858A1-Z, HL858CB(HL858B1-BL,BU 580 Connect, BU 584 Connect) FCC ID : 2ABTAHNL85A1Z Applicant : Health & Life Co. Ltd. Address : 9F., No. 186, Jian Yi Road, Zhonghe District, New Taipei City, Taiwan Date of Receipt : Sep. 24, 2020 Date of Declaration : Dec. 16, 2020 Report No. : 2090889R-E3082100014 Report Version : V1.0 The test results relate only to the samples tested. The test results shown in the test report are traceable to the national/international standard through the calibration report of the equipment and evaluated measurement uncertainty herein. This report must not be used to claim product endorsement by TAF or any agency of the government. The test report shall not be reproduced without the written approval of DEKRA Testing and Certification Co., Ltd. Measurement uncertainties evaluated for each testing system and associated connections are given here to provide the system information for reference. Compliance determinations do not take into account measurement uncertainties for each testing system, but are based on the results of the compliance measurement. Report No.: 2090889R-E3082100014 Page: 2 of 5 Issued Date: Dec. 16, 2020 Report No.: 2090889R-E3082100014 Product Name Automatic Upper Arm Blood Pressure Monitor Applicant Health & Life Co. Ltd. Address 9F., No. 186, Jian Yi Road, Zhonghe District, New Taipei City, Taiwan Manufacturer Health & Life Co. Ltd. Model No. HL858A1-Z, HL858CB(HL858B1-BL,BU 580 Connect, BU 584 Connect) FCC ID. 2ABTAHNL85A1Z Trade Name Health & Life Applicable Standard KDB 447498 D01 v06 Minimum test separation distance ≥ 20 cm For low power devices Test Result Complied Documented By : ( Senior Adm. Specialist / Joanne Lin ) Tested By : ( Supervisor / Wen Lee ) Approved By : ( Director / Vincent Lin ) Report No.: 2090889R-E3082100014 Page: 3 of 5 Revision History Report No. Ve r s i o n Description Issued Date 2090889R-E3082100014 V1.0 Initial issue of report. Dec. 16, 2020 Report No.: 2090889R-E3082100014 Page: 4 of 5 1. GENERAL INFORMATION 1.1. EUT Description Product Name Automatic Upper Arm Blood Pressure Monitor Trade Name Health & Life Model No. HL858A1-Z, HL858CB(HL858B1-BL,BU 580 Connect, BU 584 Connect) FCC ID. 2ABTAHNL85A1Z Frequency Range 2402-2480MHz Channel Number V4.2: 40CH Type of Modulation V4.2: GFSK(1Mbps) Antenna Type PCB Antenna Antenna Gain Refer to the table “Antenna List” Antenna List No. Manufacturer Part No. Antenna Type Peak Gain 1 atl LB-BLE-005 PCB Antenna 2.23dBi for 2.4GHz Report No.: 2090889R-E3082100014 Page: 5 of 5 2. RF Exposure Evaluation 2.1. Standard Applicable According to 1.1307 (b)(1), systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commission’s guideline. 2.2. Measurement Result: According to KDB Publication 447498 D01, section 4.3.1, per the calculations of item 1 (Power(mW)/separation (mm)*sqrt(f(GHz)≤3.0), SAR is required as shown in the table below where calculated values are greater than 3.0: Operation frequency = 2450MHz and antenna separation distance = 5mm Body SAR Test Exclusion Threshold = 10mW Frequency Band (MHz) Maximum peak output power Peak Gain: 2.23dBi SAR Test Exclusion Threshold Calculated Threshold Value (≦3.0 SAR is not required) conducted (dBm) EIRP (dBm) EIRP (mW) (mW) 2402 -0.93 1.3 1.35 10 0.418 Note1: The SAR/MPE measurement is not necessary. Note2: The maximum peak output power is refer to report No.: 2090889R-E3032110108 from the DEKRA.

Test Report

Report No.: 2090889R-E3032110108 Page : 1 of 58 FCC Test Report Product Name Automatic Upper Arm Blood Pressure Monitor Model No. HL858A1-Z, HL858CB(HL858B1-BL,BU 580 Connect, BU 584 Connect) FCC ID. 2ABTAHNL85A1Z Applicant Health & Life Co. Ltd. Address 9F., No. 186, Jian Yi Road, Zhonghe District, New Taipei City, Taiwan Date of Receipt Sep. 24, 2020 Issued Date Dec. 16, 2020 Report No. 2090889R-E3032110108 Report Version V1.0 The test results relate only to the samples tested. The test results shown in the test report are traceable to the national/international standard through the calibration of the equipment and evaluated measurement uncertainty herein. This report must not be used to claim product endorsement by TAF or any agency of the government. The test report shall not be reproduced without the written approval of DEKRA Testing and Certification Co., Ltd. Measurement uncertainties evaluated for each testing system and associated connections are given here to provide the system information for reference. Compliance determinations do not take into account measurement uncertainties for each testing system, but are based on the results of the compliance measurement. Report No.: 2090889R-E3032110108 Page : 2 of 58 Test Report Issued Date: Dec. 16, 2020 Report No.: 2090889R-E3032110108 Product Name Automatic Upper Arm Blood Pressure Monitor Applicant Health & Life Co. Ltd. Address 9F., No. 186, Jian Yi Road, Zhonghe District, New Taipei City, Taiwan Manufacturer Health & Life Co. Ltd. Model No. HL858A1-Z, HL858CB(HL858B1-BL,BU 580 Connect, BU 584 Connect) FCC ID. 2ABTAHNL85A1Z EUT Rated Voltage AC 100-240V, 50-60Hz EUT Test Voltage AC 120V/60Hz Trade Name Health & Life Applicable Standard FCC CFR Title 47 Part 15 Subpart C ANSI C63.4: 2014, ANSI C63.10: 2013 Test Result Complied Documented By : ( Senior Adm. Specialist / Joanne Lin ) Tested By : ( Senior Engineer / Ivan Chuang ) Approved By : ( Director / Vincent Lin ) Report No.: 2090889R-E3032110108 Page : 3 of 58 TABLE OF CONTENTS Description Page 1. GENERAL INFORMATION ............................................................................................................... 5 1.1. EUT Description ...................................................................................................................................... 5 1.2. Tested System Details .............................................................................................................................. 7 1.3. Configuration of Tested System .............................................................................................................. 7 1.4. EUT Exercise Software ........................................................................................................................... 7 1.5. Test Facility ............................................................................................................................................. 8 1.6. List of Test Equipment ............................................................................................................................. 9 1.7. Uncertainty ............................................................................................................................................ 10 2. CONDUCTED EMISSION ................................................................................................................ 11 2.1. Test Setup .............................................................................................................................................. 11 2.2. Limits ..................................................................................................................................................... 11 2.3. Test Procedure ....................................................................................................................................... 12 2.4. Test Result of Conducted Emission ....................................................................................................... 13 3. PEAK POWER OUTPUT .................................................................................................................. 19 3.1. Test Setup .............................................................................................................................................. 19 3.2. Limit ...................................................................................................................................................... 19 3.3. Test Procedure ....................................................................................................................................... 19 3.4. Test Result of Peak Power Output ......................................................................................................... 20 4. RADIATED EMISSION ..................................................................................................................... 21 4.1. Test Setup .............................................................................................................................................. 21 4.2. Limits ..................................................................................................................................................... 22 4.3. Test Procedure ....................................................................................................................................... 23 4.4. Test Result of Radiated Emission .......................................................................................................... 25 5. RF ANTENNA CONDUCTED TEST ................................................................................................ 37 5.1. Test Setup .............................................................................................................................................. 37 5.2. Limits .........................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Report No.: 2090889R-E3032110108 Page : 1 of 3 Attachment 1: EUT Test Setup Photographs Front View of Conducted Test Back View of Conducted Test Report No.: 2090889R-E3032110108 Page : 2 of 3 Front View of Spurious Emission Test Back View of Spurious Emission Test Report No.: 2090889R-E3032110108 Page : 3 of 3 Front View of Spurious Emission Test (Horn) Back View of Spurious Emission Test (Horn)

Contact Information

Applicant

Albert Lee(President)
[email protected]+886-2-8227-1300Fax: +886-2-8227-1301

Test Firm

DEKRA TESTING AND CERTIFICATION Lin Kou Lab.Mirenda Liao
[email protected]886-2-2602-7968

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz800.00 µW
Confidentiality
Long Term
Grant Notes
Power listed is conducted.

Other Applications from Health & Life Co., Ltd.

Automatic Upper Arm Blood Pressure Monitor - FCC ID 2ABTAHNL85CE1 - Health & Life Co., Ltd.
2ABTAHNL85CE1

Automatic Upper Arm Blood Pressure Monitor

Aug 24, 2021

Equipment Class

DTS - Digital Transmission System
Automatic Upper Arm Blood Pressure Monitor - FCC ID 2ABTAHNL85DM - Health & Life Co., Ltd.
2ABTAHNL85DM

Automatic Upper Arm Blood Pressure Monitor

May 02, 2021

Equipment Class

DTS - Digital Transmission System
Automatic Upper Arm Blood Pressure Monitor - FCC ID 2ABTAHNL85CG1 - Health & Life Co., Ltd.
2ABTAHNL85CG1

Automatic Upper Arm Blood Pressure Monitor

Mar 09, 2021

Equipment Class

DTS - Digital Transmission System
Automatic Wrist Blood Pressure Monitor - FCC ID 2ABTAHNL15AU - Health & Life Co., Ltd.
2ABTAHNL15AU

Automatic Wrist Blood Pressure Monitor

Jun 15, 2020

Equipment Class

DTS - Digital Transmission System
Hearing Aid - FCC ID 2ABTAHNL203 - Health & Life Co., Ltd.
2ABTAHNL203

Hearing Aid

May 14, 2020

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter