FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Metek Industrial Co. Ltd./
  3. 2ABWXWA700

2ABWXWA700WATER ALARM SYSTEM

Metek Industrial Co. Ltd.
WATER ALARM SYSTEM - FCC ID 2ABWXWA700 - Metek Industrial Co. Ltd.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Mar 16, 2014
Application Purpose
Original Equipment
Date of Application
Mar 16, 2014
Equipment Note
WATER ALARM SYSTEM
Frequency Range
433.92000000 - 433.92000000
Company
Metek Industrial Co. Ltd.
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

GENERAi: WATER ALARM SYSTEM USER ’S MANUAL WA 7 0 0 Pieαse reαd this mαnual cαrefully αnd thoroughly before using this product. TABLE OF CONTENTS Introduction 3 Key Features 3 Safety Instruction 4 ·What’s in the Package .. 4-5 etup lnstruct1ons . . . . . . . . . . . . . . . . . . . . . . . . . . 5-7 Setting the Zone on the Transmitter (Water Sensor) 5 Installing the Transmitter . . . . . . . · · · · · · 5 Setting up the Receiver .. 6-7 Testing .. 7-8 υperating instructions . . . . . ····························· 8-9 Deploy the Unit · . 8 Alert System . 9 Specifications . . . . . . . . . . · · · · · · · · · · · · · · · · · .......... 9 Maintenance Instructions . . . . . . . . . . . . . . . . . . . . . . . . 1O Changing the Battery . . . . . . . . . . . . . . . . . . . . . . . 1O Warranty Information .. 11 Return for Repair Policy 11 INTRODUCTION Thank you for purchasing General Tools & Instruments ’ WA700 Water Alarm System. Please read this user ’s manual carefully and thoroughly before using the instrument. The WA700 is a low-cost, two part water alarm system. It consists of a sensor-transmitter that is to be located in areas of high water usage, and a receiver which should be placed in a commonly used area in the house. It is ideal for detecting leaks from water heaters, washing machines, plumbing and HVAC/R systems. KEY FEATURES • Sounds alarm at sensor-transmitter and receiver when water is detected • 120-foot range enables placement of sensor-transmitter in basement and receiver in upstairs bedroom • Receiver can sound and display alarms from up to four sensor-transmitters deployed in different zones. Units can be paired on any of six channels to avoid interference. • Standard package includes one receiver with AC adaptor and one sensor-transmitter with "9V” battery. Optional package of three additional sensor-transmitters and batteries (WA700 SEN) is available. • Sensor with suction cup is at the end of 23-in. long cord, increasing placement options. Transmitter unit includes battery test button/LED on side. • Long battery life (up to one year) • One-year limited waηanty SAFETY INSTRUCTION Do not use the WA700 in the presence of flammable or explosive gases. 明1HAT’S IN THE PACKAGE The WA700 comes in a blister pack containing: • Receiver with 1lOVAC Adapter Zone Setting Z l Z2 Z3 Z4 A B 。。 • Sensor-transmitter with battery • A hard copy of this user ’s manual (inside the fold-over card) SETUP INSTRUCTIONS SETTING THE ZONE ON THE TRANSMITTER (WATER SENSOR) The following chart indicates the 4-zone setting parameters and the picture shows a setting of Zone 1 (Z 1). 。 。 Note: The transmitter comes factory preset for Zone 1(Z 1) . INSTALLING THE TRANSMITTER • Remove the battery compartment cover on the back of the transmitter. • Connect a fresh 9V battery (PP3 or equivalent) and place the cover back on. • To check the battery condition, press the “TEST/LO认T BATT.” button located on right size of the transmitter . The red LED indicator on the front of the transmitter will light up which represents a good battery is being used. Otherwise, replace with a fresh battery immediately. •Mount the transmitter to the appropriate location. The transmitter is now ready to arm. ,、 ( 面 写 SETTIN G UP THE RECEIVER • Place the receiver in a convenient location, no further than 120 feet from the transmitter. Please note that walls, metallic objects, etc. may reduce the range. • Plug-in the adaptor to the receiver. - m - m · a · n · u • Set the ON/OFF switch in the 'on’ position and the green LED indicator will light up. The receiver is now armed and ready. TESTING The Alarm System should be tested after installation. •Test for the water sensor: Place the tips of the water sensor in water and observe the receiver. If the zone indicator lights up and the transmitter sounds, the system is operating properly. •Test for RF signal: Press the “ TEST/LO认r BATT.” button for 5 seconds to emit the RF signal. The zone indicator will light up solid and the transmitter will sound which represents the system is operating properly. •The zone indicator will change to flashing if another zone has been triggered. OPERATING INSTRUCTIONS DEPLOY THE UNIT The receiver should be placed in a convenient location in the house that is commonly occupied. This will allow for quick reaction times in case of an emergency. Each of the sensors should be placed in close proximity to areas of high water usage (i.e. Hot Water Heater, Washing Machine, Sinks, etc.) and can be mounted with a suction cup on the bottom. Doing so will offer the most accurate readings and fast alert times in the event of a water buildup. The transmitter should be mounted at least 5 in. or higher above the ground to keep it out of the way of a rising water level. ALERT SYSTEM The receiver will activate when water reaches both of the copper contacts located in the transmitter. The receiver will emit a continuous beeping sound until it is turned off by the user. To reset the unit and shut off the sound, tum the power switch on the receiver to OFF and then to ON. The system will not arm again until this process is completed. SPECIFICATIONS Wireless Range 120 ft. (37m), max Operating Frequency 432.92 MHz Alarm Volume 88dBA at Receiver Receiver Zone Alarm Indicators LEDs Sensor Dimensions 1.57 x 1.18 x 0.55 in. (40 x 30 x 14mm) Tr ansmitter Dimensions 2.76 x 2.36 x 1.14 in. (70 x 60 x 29mrn) Receiver Dimensions 3.70 x 3.31x 1.46 in. (94 x 84 x 37mrn) Length of Sensor Cord 23 in. (584mrn) Weight of Standard Package 6.0 oz. (170g) Weight of Optional Package of Three Sensors and Batteries (WA700 SEN) 9.4 oz. (267g) Power Source 9V AC adaptor for receiver; “9V” battery for transmitter Battery Life (typical) in Standby Mode 1 year MAINTENANCE INSTRUCTIONS CHANGING THE BATTERY Plug the included "9V” battery into the wired socket inside the compartment. The terminals of the battery and the socket mate in only one way, with the smaller male terminal plugging into the larger fema…

Text truncated - open the document above for the full version.

Cover Letter(s)

Federal Communications Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 Date: 2014.3.11 SUBJECT: FCC Application for 2ABWXWA700 To Whom It May Concern: I, the undersigned, hereby attest to the fact that I will apply the Declaration of Conformity procedure to the receiver of this system device. I understand the following FCC requirements: 1. Devices subject to the DoC procedure are required to be tested to show compliance with the FCC technical regulations by a recognized accredited testing laboratory. The testing laboratory must be accredited by a Commission approved accreditation body or designated under the terms of a government-to-government Mutual Recognition Agreement (MRA). A listing of those accredited testing laboratories that have been recognized by the Commission is published on the FCC Webpage: https://apps.fcc.gov/oetcf/eas/reports/TestFirmSearch.cfm (Select the "accredited" option to search for FCC recognized accredited test firms.) 2. Test facilities located in countries, where the U.S. does not have an operational Telcom MRA are not recognized by the FCC to test for the DoC procedure. 3. Pt 2.1077 contains the list of information that must be included in the Declaration of Conformity, which must be supplied with each product sold. The DoC compliance info shall be included in the User’s Manual or as a separate sheet. The info must contain the name, address, and phone number of the responsible party, which must be located within the United States. According to 2.909(c)(2), the responsible party is either the Manufacturer or if the product is imported the Importer. Regards, Signature: Typed name and title: Ye Jizhong Applicant: Metek Industrial Co. Ltd. Address: Unit7,17/F Grandtech Centre,8 On Ping Street,Shatin,N.T.,Hong Kong.

External Photos

Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn WA700 - Appearance View Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn

ID Label/Location Info

FCC Label Location for model: WA700 The Label must not be a stick-on paper. The Label on these products must be permanently affixed to the product and readily visible at the time of purchase and must last the expected lifetime of the equipment not be readily detachable. FCC ID: 2ABWXWA700 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

ID Label/Location Info

FCC Label Sample for model: WA700 FCC ID: 2ABWXWA700 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

Internal Photos

Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn WA700- Internal View Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Monopole antenna Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn

Test Report

TEST REPORT Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Page 1 of 25 Reference No. .................... : WTD14S0111065E FCC ID ................................ : 2ABWXWA700 Applicant ............................ : Metek Industrial Co. Ltd. Address .............................. : Unit7,17/F Grandtech Centre,8 On Ping Street,Shatin,N.T.,Hong Kong. Manufacturer .................... : Dongguan Metek Electronics Co. Ltd. Address .............................. : 86 Diao Lang Road, Diao Lang Village, Huang Jiang Town, Dongguan, China Product Name .................... : WATER ALARM SYSTEM Model No. ........................... : WA700 Standards ........................... : FCC CFR47 Part 15 Section 15.231: 2012 Date of Receipt sample .... : Jan.21, 2014 Date of Test ........................ : Jan.26~Feb.12, 2014 Date of Issue ...................... : Mar.11, 2014 Test Result ......................... : Pass * Remarks: The results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company.The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Prepared By: Waltek Services (Shenzhen) Co., Ltd. Address: 1/F., Fukangtai Building, West Baima Road, Songgang Street, Baoan District, Shenzhen, Guangdong, China Testing location: 1/F., Fukangtai Building, West Baima Road, Songgang Street, Baoan District, Shenzhen, Guangdong, China Tel :+86-755-83551033 Fax:+86-755-83552400 Compiled by: Approved by: Zero Zhou / Project Engineer Philo Zhong / Manager Reference No.: WTD14S0111065E Page 2 of 25 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn 2 Test Summary Test Items Test Requirement Result Conducted Emissions 15.207 PASS Radiated Spurious Emissions 15.205(a) 15.209 15.231(b) PASS Periodic Operation 15.231(a) PASS 20dB Bandwidth 15.231(c) PASS Antenna Requirement 15.203 PASS Reference No.: WTD14S0111065E Page 3 of 25 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn 3 Contents Page 1 COVER PAGE ............................................................................................................................................ 1 2 TEST SUMMARY .................................................................................................................................................... 2 3 CONTENTS .............................................................................................................................................................. 3 4 GENERAL INFORMATION ................................................................................................................................... 4 4.1 GENERAL DESCRIPTION OF E.U.T. ............................................................................................................. 4 4.2 DETAILS OF E.U.T........................................................................................................................................ 4 4.3 TEST FACILITY .............................................................................................................................................. 4 4.4 TEST LOCATION ............................................................................................................................................ 4 5 EQUIPMENT USED DURING TEST .................................................................................................................... 5 5.1 EQUIPMENTS LIST ........................................................................................................................................ 5 5.2 MEASUREMENT UNCERTAINTY .................................................................................................................... 5 5.3 TEST EQUIPMENT CALIBRATION .................................................................................................................. 5 6 CONDUCTED EMISSION TEST ........................................................................................................................... 6 6.1 E.U.T. OPERATION ...................................................................................................................................... 6 6.2 EUT SETUP .................................................................................................................................................. 6 6.3 CONDUCTED EMISSION TEST RESULT ......................................................................................................... 7 7 RADIATION EMISSION TEST .............................................................................................................................. 9 7.1 EUT OPERATION: ........................................................................................................................................ 9 7.2 TEST SETUP ................................................................................................................................................. 9 7.3 SPECTRUM ANALYZER SETUP ................................................................................................................... 10 7.4 TEST PROCEDURE ..................................................................................................................................... 10 7.5 CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................. 10 7.6 SUMMARY OF TEST RESULTS .................................................................................................................... 11 8 PERIODIC OPERATION ...................................................................................................................................... 12 9 20DB BANDWIDTH .............................................................................................................................................. 14 9.1 TEST PROCEDURE .....…

Text truncated - open the document above for the full version.

Test Setup Photos

Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn WA700-Photograph Conducted Emission Test Setup Radiation Emission Test Setup From 30MHz to 1GHz Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Above 1GHz

Contact Information

Applicant

Jizhong Ye(Engineer)
[email protected](86) 769-83364575Fax: (86) 769-83635392

Test Firm

Waltek Services(Shenzhen) Co., Ltd.Philo zhong
[email protected]0086-755-27553488Fax: 0086-755-27553868

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term