
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Model Name: VIONTA Q10 Product Name: Qi2 Ultra Slim Power Bank Specification: Battery Capacity: 5000mAh / 7.74V / 38.7Wh Input Power: USB-C: 5V⎓3A, 9V⎓3A 12V⎓2.5A, 15V⎓2A, 20V⎓1.5A Output Power: Wireless: 5W / 7.5W / 10W / 15W USB-C: 5V⎓3A, 9V⎓3A 12V⎓2.5A, 15V⎓2A, 20V⎓1.5A Wireless + USB-C: 5V ⎓ 3A, 15W max. Operating Temperature: 0°C - 35°C Size: 114 x 67.5 x 14mm Weight: 202g 1 Year Limited Warranty Made in China The product can only be used to charge smartphones / earbuds. Please refer to the user manual for instructions and more product information. FCC Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications not expressly approved by the party responsible forcompliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. FCC Radiation Exposure Statement This device complies with FCC RF radiation exposure limits set forth for an uncontrolled environment for portable condition. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. RF warning statement The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction. Protective Function: 1. Multiple circuit protection 2. Over-current protection Magnetic Wireless Charger USB-C (Input/Output) Power Button LED Indicator 3. Short-circuit protection 4. Over-voltage protection 5. Flame retardant protection 6. Over-heat protection Attention: 1. Do not expose to liquids 2. Do not shake while charging 3. Unplug the device when fully charged 4. Do not disassemble, puncture, drop, bend or modify 5. Keep away from children 6. Avoid extreme temperatures 7. 1-Year Limited Warranty 8. Please scan the QR code on the packaging for the user manual 9. For the fastest and safest charge, use an ADAM cable, your deviceʼs original cable or a certified cable (such as MFi) FCC ID: 2ABY9VIONTA-Q10
Attestation Statements Date: 2025-09-29 TO: Federal Communications Commission Authorization and Evaluation Division 7435 Oa kland Mills Road Columbia, MD 21046, USA RE: Attestation Statements Part 2.911(d)(7) request for (FCC ID: 2ABY9VIONTA-Q10) Adam Elements International Co., LTD. the undersigned, hereby authorize HOPEK CORPORATION INC to act as our designated U.S. agent for service of process, Adam Elements International Co., LTD. accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. HOPEK CORPORATION INC accepts the responsibility to act as designated U.S. agent for service of process. Applicant Information: Company name: Adam Elements International Co., LTD. Contact Name: Alan Chang Address: 8F.-5, No. 148, Sec. 4, Zhongxiao E. Rd., Da’an Dist., Taipei City 106, Taiwan Telephone No: +886-2-27389900 Email: [email protected] FRN: 0023421845 Signature: Alan Chang U .S. Agent Information: Company Name: HOPEK CORPORATION INC Address: 16755 Coyote Bush Dr Unit 84, San Diego, CA 92127 United States FRN: 0034562900 Contact Name: Peter Davis Telephone No: 561-235-6113 Email: [email protected] Sig nature: Peter Davis
Rev 1/26/2023 Adam Elements International Co., LTD. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2025-9-29 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2ABY9VIONTA-Q10 Adam Elements International Co., LTD. certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Adam Elements International Co., LTD. certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Device is inherently compliant based on hardware limitations or software controls. or A Software Bill of Materials (SBOM) is provided to the TCB for review, and The end-user or third parties cannot install additional software on this device. Sincerely, (Applicant signature) (Alan Chang) Rev 1/26/2023 Adam Elements International Co., LTD. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2025-09-29 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: 2ABY9VIONTA-Q10 Adam Elements International Co., LTD. certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Alan Chang)
东莞市石碣阿美欧电子厂 Dongguan Shijie AMEIOU electronics factory 产 品 规 格 承 认 书 SPECIFICATION FOR APPROVAL ■产品形状和尺寸 Product Apperance & Dimensions (Unit: mm) ( Note: The pictures are for reference only. The actual product may vary. ) ■产品电气特性 Product Electrical characteristics 参数 (Parameter): 数值(Value) 产品名称(Product name) Wireless charging coil module 产品编号 (Product number): Q4208A11-45K3MTY+20(65P,8.1uh) 铁氧体型号 (Ferrite type): Φ42.5*Φ5*0.8mm(With bad stuff) 线材型号 (Coil type): Multi-strand enameled wire 0.08*65P 线圈匝数 (Coil Turns): 11TS 绕线方向(Coil direction): Clockwise (taking the outermost circle as the reference) 电感 (Inductance): 8.1 μH ±10% Q值(Q Value): 40(Min) 直流电阻 (DC Resistance): 85 mΩ (Max.) 测试仪器 (Testing Instrument): TH2816B @100kHz、1Vrms、TH2512B At 25°C 备注(Note): The back of the product is pasted with 3M9448A double-sided tape ■更多信息请咨询我们(Contact Us For More Information)。 Room 501, No. 19, South Liuwuzhou Tou Road, Shijie Town, Dongguan City, Guangdong Province Counting from the edge of the coil Exc luding the thickness of the centrifuged paper
Adam Elements International Co., LTD. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: September 29, 2025 Subject; Request for Confidentiality FCC ID: 2ABY9VIONTA-Q10 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Alan Chang Title: General Manager
Effective Date: April 2, 2020 QSF 7.6.4-8 – Agent Authorization Letter Template Page 1 of 1 Revision Date: Revision: 0 Adam Elements International Co., LTD. Date:29/09/2025 Product Model Number: VIONTA Q10 FCC ID:2ABY9VIONTA-Q10 To whom it may concern, Re: Product Certification Representative Authorization Letter We authorize QAI Laboratories Ltd. 3980 North Fraser Way, Burnaby B.C. Canada V5J 5K5 to act on our behalf on all matters concerning the above named equipment. This shall include the following: • Testing • Approval applications and procedures We declare that QAI Laboratories Ltd. is allowed to forward all information related to the approval project to the applied certification body and to the notification entities and to discuss any issues concerning the approval application. Any and all acts carried out by QAI Laboratories Ltd. on our behalf shall have the same effect as acts of our own. By: Alan Chang Contact Listed on FCC Wesbite Title: General Manager Email: [email protected] On behalf of: Adam Elements International Co., LTD.
Page 1 of 4 Report No.: FCS202509127 APPENDIX-PHOTOGRAPHS OF EUT CONSTRUCTIONAL DETAILS Model: VIONTA Q10 Photo 1 Photo 2 Page 2 of 4 Report No.: FCS202509127 Photo 3 Photo 4 Page 3 of 4 Report No.: FCS202509127 Photo 5 Photo 6 Page 4 of 4 Report No.: FCS202509127 Photo 7 Photo 8
Label Size: L20mm * W8mm 1. The label is silk-screen on the sample This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Page 1 of 5 Report No.: FCS202509127 APPENDIX-PHOTOGRAPHS OF EUT CONSTRUCTIONAL DETAILS Model: VIONTA Q10 Photo 1 Photo 2 Page 2 of 5 Report No.: FCS202509127 Photo 3 Photo 4 Page 3 of 5 Report No.: FCS202509127 Photo 5 Photo 6 Page 4 of 5 Report No.: FCS202509127 Photo 7 Photo 8 Page 5 of 5 Report No.: FCS202509127 Photo 9 Photo 10 coil antenna
FCC Test Report Report No: FCS202509127H01 Issued for Applicant: Adam Elements International Co., LTD. Address: 8 F.-5, No. 148, Sec. 4, Zhongxiao E. Rd., Da’an Dist., Taipei City 106, Taiwan Product Name: Qi2 Ultra Slim Power Bank Brand Name: Model Name: VIONTA Q10 Series Model: N/A FCC ID: 2ABY9VIONTA-Q10 Test Standard: FCC CFR 47 PART 1, § 1.1310 KDB 680106 D01 Wireless Power Transfer v04 Issued By: Flux Compliance Service Laboratory Add: Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Te c h Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Page 2 of 18 Report No.: FCS202509127H01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com TEST RESULT CERTIFICATION Applicant’s Name ................... : Adam Elements International Co., LTD. Address .................................. : 8 F.-5, No. 148, Sec. 4, Zhongxiao E. Rd., Da’an Dist., Taipei City 106, Taiwan Manufacture's Name .............. : Guangdong Yicheng Technology Co., Ltd Address .................................. : Room1001, No. 247 Huaide Road, Humen Town, Dongguan City, Guangdong Province Product Description Product Name ........................ : Qi2 Ultra Slim Power Bank Brand Name ......................... : Model Name ........................... : VIONTA Q10 Series Model .......................... : N/A Test Standards ....................... : FCC CFR 47 PART 1, § 1.1310 KDB 680106 D01 Wireless Power Transfer v04 This device described above has been tested FCS, the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of FCS, this document may be altered or revised by FCS, personal only, and shall be noted in the revision of the document.. Date of Test ................................ : Date (s) of performance of tests . : Sept. 05, 2025 ~ Sept. 11, 2025 Date of Issue .............................. : Sept. 11, 2025 Test Result .................................. : Pass Tested by : (Scott Shen) Reviewed by : (Duke Qian) Approved by : (Jack Wang) Page 3 of 18 Report No.: FCS202509127H01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Table of Contents Page 1. TEST FACTORY 5 2. GENERAL INFORMATION 6 2.1 GENERAL DESCRIPTION OF THE EUT 6 3 TEST METHODOLOGY 7 3.1 MEASURING STANDARD 7 3.2 REQUIREMENTS 7 3.1 LIMITS 7 3.2 TEST SETUP 8 3.3 TEST PROCEDURE 8 4 EQUIPMENT APPROVAL CONSIDERATIONS 10 4.1 DESCRIPTION OF THE TEST MODE 11 4.2 PERIPHERAL LIST 11 4.3 TEST INSTRUMENTS LIST 11 4.4 ANTENNA TO EUT SIDE 14 4.5 TEST RESULT 15 4.6 TEST SETUP PHOTO 16 Page 4 of 18 Report No.: FCS202509127H01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Revision History Rev. Issue Date Effect Page Contents 00 Sept. 11, 2025 ALL Initial Issue Page 5 of 18 Report No.: FCS202509127H01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com 1. TEST FACTORY Company Name: Flux Compliance Service Laboratory Address: Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Telephone: +86-769-27280901 Fax: +86-769-27280901 FCC Test Firm Registration Number: 514908 Designation number: CN0127 A2LA accreditation number:5545.01 CNAS: L15566 Page 6 of 18 Report No.: FCS202509127H01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF THE EUT Product Name Qi2 Ultra Slim Power Bank Trade Name Model Name VIONTA Q10 Series Model N/A Model Difference N/A Operation frequency 110.5kHz-205kHz, 360kHz Modulation Technology ASK Antenna Type Loop coil antenna Antenna gain 0dBi Power Supply Input: 5V⎓3A, 9V⎓3A, 12V⎓2.5A, 15V⎓2A, 20V⎓1.5A Output: Wireless: 5W / 7.5W / 10W / 15W USB-C : 5V⎓3A, 9V⎓3A, 12V⎓2.5A, 15V⎓2A, 20V⎓1.5A Wireless + USB-C: 5V⎓3A, 15W max Hardware version number V1.0 Software version number V1.0 Connecting I/O Port(s) Please refer to the User's Manual Page 7 of 18 Report No.: FCS202509127H01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com 3 TEST METHODOLOGY 3.1 Measuring Standard According to §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. According to §1.1310 and §2.1091 RF exposure is calculated. According KDB680106 D01: KDB 680106 D01 Wireless Power Transfer v04. 3.2 Requirements According to the item 3 of KDB 680106 D01v04: Inductive wireless power transfer applications that meet all of the following requirements are excluded from submitting an RF exposure evaluation. (1) Mobile Device and Portable Device Configurations (2) Equipment Authorization Procedures for Devices Operating at Frequencies Below 4 MHz (3) The EUT H-field strengths is tested 2cm increments from 0 ~ 20 cm for all sides. 3.1 Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposur…
Text truncated - open the document above for the full version.
FCC Test Report Report No: FCS202509127W01 Issued for Applicant: Adam Elements International Co., LTD. Address: 8 F.-5, No. 148, Sec. 4, Zhongxiao E. Rd., Da’an Dist., Taipei City 106, Taiwan Product Name: Qi2 Ultra Slim Power Bank Brand Name: Model Name: VIONTA Q10 Series Model: N/A FCC ID: 2ABY9VIONTA-Q10 Test Standard: FCC Part 15C Issued By: Flux Compliance Service Laboratory Add: Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Te c h Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Page 2 of 23 Report No.: FCS202509127W01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com EST RESULT CERTIFICATION Applicant’s Name ................... : Adam Elements International Co., LTD. Address .................................. : 8 F.-5, No. 148, Sec. 4, Zhongxiao E. Rd., Da’an Dist., Taipei City 106, Taiwan Manufacture's Name .............. : Guangdong Yicheng Technology Co., Ltd Address .................................. : Room1001, No. 247 Huaide Road, Humen Town, Dongguan City, Guangdong Province Product Description Product Name ........................ : Qi2 Ultra Slim Power Bank Brand Name ......................... : Model Name ........................... : VIONTA Q10 Series Model .......................... : N/A Test Standards ....................... : FCC Rules and Regulations Part 15 Subpart C Test Procedure ....................... : ANSI C63.10:2013 This device described above has been tested FCS, the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of FCS, this document may be altered or revised by FCS, personal only, and shall be noted in the revision of the document.. Date of Test ................................ : Date (s) of performance of tests . : Sept. 05, 2025 ~ Sept. 17, 2025 Date of Issue .............................. : Sept. 17, 2025 Test Result .................................. : Pass Tested by : (Scott Shen) Reviewed by : (Duke Qian) Approved by : (Jack Wang) Page 3 of 23 Report No.: FCS202509127W01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Table of Contents Page 1. SUMMARY OF TEST RESULTS 5 1.1 TEST FACTORY 6 1.2 MEASUREMENT UNCERTAINTY 6 2. GENERAL INFORMATION 7 2.1 GENERAL DESCRIPTION OF THE EUT 7 2.2 DESCRIPTION OF THE TEST MODES 8 2.3 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS 9 2.4 EQUIPMENTS LIST 10 3. CONDUCTED EMISSION MEASUREMENT 11 3.1 LIMIT 11 3.2 TEST PROCEDURE 11 3.3 TEST SETUP 12 3.4 TEST RESULTS 13 4. RADIATED EMISSION MEASUREMENT 15 4.1 LIMIT 15 4.2 TEST SETUP 16 4.4 TEST RESULTS 17 5. 20 DB BANDWIDTH TEST 23 5.1 TEST PROCEDURE 23 5.2 TEST SETUP 23 5.4 TEST RESULTS 24 6. ANTENNA REQUIREMENT 26 6.1 STANDARD REQUIREMENT 26 6.2 EUT ANTENNA 26 Page 4 of 23 Report No.: FCS202509127W01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Revision History Rev. Issue Date Effect Page Contents 00 Sept. 17, 2025 ALL Initial Issue Page 5 of 23 Report No.: FCS202509127W01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com 1. SUMMARY OF TEST RESULTS Test Item Section in CFR 47 Result Antenna requirement 15.203 Pass AC Power Line Conducted Emission 15.207 Pass Spurious Emission 15.209(a)(f) Pass 20dB Bandwidth 15.215 Pass NOTE: (1)” N/A” denotes test is not applicable in this Test Report (2) All tests are according to ANSI C63.10-2013 Page 6 of 23 Report No.: FCS202509127W01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com 1.1 TEST FACTORY Company Name: Flux Compliance Service Laboratory Address: Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Telephone: +86-769-27280901 Fax: +86-769-27280901 FCC Test Firm Registration Number: 514908 Designation number: CN0127 A2LA accreditation number:5545.01 CNAS: L15566 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ±U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. No. Item Uncertainty 1 Conducted Emission (9KHz-150KHz) ±4.13 dB 2 Conducted Emission (150KHz-30MHz) ±4.74 dB 3 All emissions, radiated 9kHz-30MHz ±3. 10 dB 4 All emissions, radiated 30MHz-1000MHz ±3.20 dB 5 Occupied Channel Bandwidth ±3.5% Page 7 of 23 Report No.: FCS202509127W01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF THE EUT Product Name Qi2 Ultra Slim Power Bank Trade Name Model Name VIONTA Q10 Series Model N/A Model Difference N/A Operation frequency 110.5kHz-205kHz, 360kHz Modulation Technology ASK Antenna Type Loop coil antenna Antenna gain 0dBi Power Supply Input: 5V⎓3A, 9V⎓3A, 12V⎓2.5A, 15V⎓2A, 20V⎓1.5A Output: Wireless: 5W / 7.5W / 10W / 15W USB-C: 5V⎓3A, 9V⎓3A, 12V⎓2.5A, 15V⎓2A, 20V⎓1.5A Wireless + USB-C: 5V⎓3A, 15W max Hardware version number V1.0 Software version number V1.0 Connecting I/O Port(s) Plea…
Text truncated - open the document above for the full version.
Page 1 of 2 Report No.: FCS202509127 Setup photo Model Number: VIONTA Q10 Radiation 9K – 30M Radiation 30M-1G Page 2 of 2 Report No.: FCS202509127 CE
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.1105 MHz - 0.205 MHz | - |
| 2 | 15C | 0.36 MHz - 0.36 MHz | - |
Magnetic Wireless Power Bank
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHzMagnetic Wireless Power Bank
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Qi2 Ultra Slim Power Bank
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Qi2 Power Bank with Built-In Cable
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Ultra Slim Magnetic Wireless Charging Power Bank
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz