Rhythmedix, LLC Date: 2014-05-06 Federal Communications Commission Authorization and Evaluation Division FCC ID: 2ACA9-10002 ATTESTATION FCC ID: 2ACA9-10002 Product: RhythmStar Model: RS-10002 We don't provide any controls or software to allow operation outside the USA frequency band when we sell this product in USA. Sincerely, Stan Biletsky/Certification Manager Rhythmedix, LLC
RF_160, Issue 02 Rhythmedix, LLC We Name: Rhythmedix, LLC Address: 5000 Atrium Way, Ste. 1, Mt. Laurel, NJ 08054, USA City: Mt. Laurel . Country: United States . Declare that: Name Representative of agent: Gene Chang (1) Agent Company name: QuieTek Corp. Address: Fl.2, No.345, Xin-hu 2 nd Rd., Nei-hu District City: Taipei Country Taiwan is authorized to apply for Certification of the following product(s): Product description: RhythmStar ............ Type designation: RS-10002 Trademark: Rhythmedix, RhythmStar on our behalf. Date: 2014-05-06.. City: Mt. Laurel.. Name: Stan Biletsky.. Function: ...... Certification Manager ............................ Signature: ............................................. Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent.
Rhythmedix, LLC DATE Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID:___ 2ACA9-10002 _________ Product Name:____ RhythmStar _______ Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commission’s rules, we hereby request that the following documents be held confidential: (List here the documents for which you are seeking confidentiality – for example ...) Schematics Block diagram Operation description & Tune up These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. Date this 2014-05-06 By: Stan Biletsky Signature Printed Title: Certification Manager On behalf of : Rhythmedix, LLC (Company Name) Telephone: 856 282 1080-223
Rhythmedix, LLC DATE Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID:____ 2ACA9-10002 ________ Product Name:___ RhythmStar ________ Request for Short-Term Confidentiality Pursuant to Sections 0.457 and 0.459 of the commission rules, and in accordance with the FCC Public notice dated June 15, 2004 (DA 04-1705), we hereby request short-term confidentiality for the following items prior to marketing the device.: Test Setup Photos External Photos Internal Photos User Manual These documents contain detailed system and equipment description and related information about the product which Rhythmedix, LLC considers to be proprietary, confidential, and a custom design and, otherwise would not release to the general public. Since this design is a basis from which future technological products will evolve, Rhythmedix, LLC considers this information to be of benefit to its competitors, and that the disclosure of information in these documents would give competitors an unfair advantage in the market. This request is being made retroactively due to an over site on our part. We understand that the information has been publicly available 180 days after date of grant. Date this 2014-05-06 By: Stan Biletsky Signature Printed Title: Certification Manager On behalf of : Rhythmedix, LLC (Company Name) Telephone: 856 282 1080-223
(1) EUT Photo (2) EUT Photo (3) EUT Photo (4) EUT Photo (5) EUT Photo (6) EUT Photo (7) EUT Photo (Battery) (8) EUT Photo (Battery) (9) EUT Photo (10) EUT Photo
(1) EUT Photo (2) EUT Photo (3) EUT Photo (4) EUT Photo(Single SIM Slot) (5) EUT Photo(Single SIM Slot) (6) EUT Photo(Single SIM Slot) (7) EUT Photo(Single SIM Slot) (8) EUT Photo(Single SIM Slot)
SAR Test Report Product Name : RhythmStar Model No. : RS-10002 FCC ID : 2ACA9-10002 Applicant : Rhythmedix, LLC Address : 5000 Atrium Way, Ste. 1, Mt. Laurel, NJ 08054, USA Date of Receipt : Apr. 10, 2014 Date of Test : Apr. 10, 2014 Issued Date : Apr. 25, 2014 Report No. : 1440261R-HP-US-P03V01 Report Version : V1.0 The test results relate only to the samples tested. The test report shall not be reproduced except in full without the written approval of QuieTek Corporation. Report No.: 1440261R-HP-US-P03V01 Page: 2 of 96 Test Report Certification Issued Date: Apr. 25, 2014 Report No.: 1440261R-HP-US-P03V01 Product Name : RhythmStar Applicant : Rhythmedix, LLC Address : 5000 Atrium Way, Ste. 1, Mt. Laurel, NJ 08054, USA Manufacturer : Rhythmedix, LLC Address : 5000 Atrium Way, Ste. 1, Mt. Laurel, NJ 08054, USA Model No. : RS-10002 FCC ID : 2ACA9-10002 Brand Name : RhythMedix, RhythmStar EUT Voltage : DC 3.7V Applicable Standard : FCC KDB Publication 447498 D01v05r02 FCC KDB Publication 648474 D04v01r02 FCC KDB Publication 865664 D01v01r03 FCC KDB Publication 941225 D01~D06 Test Result : Max. SAR Measurement (1g) Body-worn: 1.44 W/kg Performed Location : Suzhou EMC Laboratory No.99 Hongye Rd., Suzhou Industrial Park Loufeng Hi-TechDevelopment Zone., Suzhou, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 FCC Registration Number: 800392 Documented By : Reviewed By : Approved By : Report No.: 1440261R-HP-US-P03V01 Page: 3 of 96 Laboratory Information We, QuieTek Corporation, are an independent EMC and safety consultancy that was established the whole facility in our laboratories. The test facility has been accredited/accepted(audited or listed) by the following related bodies in compliance with ISO 17025, EN 45001 and specified testing scope: The related certificate for our laboratories about the test site and management system can be downloaded from QuieTek Corporation’s Web Site :http://www.quietek.com/tw/ctg/cts/accreditations.htm The address and introduction of QuieTek Corporation’s laboratories can be founded in our Web site : http://www.quietek.com/ If you have any comments, Please don’t hesitate to contact us. Our contact information is as below: HsinChu Testing Laboratory : No.75-2, 3rd Lin, Wangye Keng, Yonghxing Tsuen, Qionglin Shiang, Hsinchu County 307, Taiwan, R.O.C. TEL:+886-3-592-8858 / FAX:+886-3-592-8859 E-Mail : [email protected] LinKou Testing Laboratory : No.5-22, Ruishukeng, Linkou Dist., New Taipei City 24451, Taiwan, R.O.C. TEL : 886-2-8601-3788 / FAX : 886-2-8601-3789 E-Mail : [email protected] Suzhou Testing Laboratory : No.99 Hongye Rd., Suzhou Industrial Park Loufeng Hi-Tech Development Zone., SuZhou, China TEL : +86-512-6251-5088 / FAX : 86-512-6251-5098 E-Mail : [email protected] Taiwan R.O.C. : BSMI, NCC, TAF Germany : TUV Rheinland Norway : Nemko, DNV USA : FCC Japan : VCCI China : CNAS Report No.: 1440261R-HP-US-P03V01 Page: 4 of 96 TABLE OF CONTENTS Description Page 1. General Information ................................................................................................. 6 1.1. EUT Description .................................................................................................. 6 1.2. Test Environment ................................................................................................. 7 1.3. EUT Antenna Locations ....................................................................................... 7 1.4. SAR Test Exclusions Applied ............................................................................... 8 1.5. Power Reduction for SAR .................................................................................... 8 1.6. Guidance Documents .......................................................................................... 8 2. SAR Measurement System ...................................................................................... 9 2.1. DASY5 System Description ................................................................................. 9 2.1.1. Applications ................................................................................................... 10 2.1.2. Area Scans .................................................................................................... 10 2.1.3. Zoom Scan (Cube Scan Averaging) .............................................................. 10 2.1.4. Uncertainty of Inter-/Extrapolation and Averaging ......................................... 10 2.2. DASY5 E-Field Probe ........................................................................................ 11 2.2.1. Isotropic E-Field Probe Specification ............................................................. 11 2.3. Boundary Detection Unit and Probe Mounting Device ...................................... 12 2.4. DATA Acquisition Electronics (DAE) and Measurement Server ........................ 12 2.5. Robot ................................................................................................................. 13 2.6. Light Beam Unit ................................................................................................. 13 2.7. Device Holder .................................................................................................... 14 2.8. SAM Twin Phantom ........................................................................................... 14 3. Tissue Simulating Liquid ....................................................................................... 15 3.1. The composition of the tissue simulating liquid ................................................. 15 3.2. Tissue Calibration Result ................................................................................... 16 3.3. Tissue Dielectric Parameters for Head and Body Phantoms ............................. 17 4. SAR Measurement Procedure ............................................................................... 18 4.1. SAR System Validation ..............................................…
Text truncated - open the document above for the full version.
FCC Part22H&24E Test Report Product Name : RhythmStar Model No. : RS-10002 FCC ID : 2ACA9-10002 IC : 11948A-10002 Applicant : Rhythmedix, LLC Address : 5000 Atrium Way, Ste. 1, Mt. Laurel, NJ 08054, USA Date of Receipt : Apr. 10, 2014 Test Date : Apr. 10, 2014~ Apr. 24, 2014 Issued Date : Apr. 25, 2014 Report No. : 1440261R-HP-US-P07V01 Report Version : V 1.0 The test results relate only to the samples tested. The test results shown in the test report are traceable to the national/international standard through the calibration of the equipment and evaluated measurement uncertainty herein. This report must not be used to claim product endorsement by TAF, CNAS or any agency of the government. The test report shall not be reproduced without the written approval of QuieTek Corporation. Report No.: 1440261R-HP-US-P07V01 Page: 2 of 80 Test Report Certification Issued Date : Apr. 25, 2014 Report No. : 1440261R-HP-US-P07V01 Product Name : RhythmStar Applicant : Rhythmedix, LLC Address : 5000 Atrium Way, Ste. 1, Mt. Laurel, NJ 08054, USA Manufacturer : Rhythmedix, LLC Address : 5000 Atrium Way, Ste. 1, Mt. Laurel, NJ 08054, USA Model No. : RS-10002 FCC ID : 2ACA9-10002 IC : 11948A-10002 EUT Voltage : DC 3.7V Brand Name : RhythMedix, RhythmStar Applicable Standard : FCC CFR Title 47 Part 2,TIA/EIA 603-C FCC Part22 Subpart H, FCC Part24 Subpart E Industry Canada RSS-132, Issue 2 Clause 4.5&4.6 Industry Canada RSS-133, Issue 5 Clause 6.5&6.6 Test Result : Complied Performed Location : Suzhou EMC Laboratory No.99 Hongye Rd., Suzhou Industrial Park Loufeng Hi-Tech Development Zone., Suzhou, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 FCC Registration Number: 800392; IC Lab Code: 4075B Documented By : Reviewed By : Approved By : Report No.: 1440261R-HP-US-P07V01 Page: 3 of 80 Laboratory Information We, QuieTek Corporation, are an independent EMC and safety consultancy that was established the whole facility in our laboratories. The test facility has been accredited/accepted(audited or listed) by the following related bodies in compliance with ISO 17025, EN 45001 and specified testing scope: The related certificate for our laboratories about the test site and management system can be downloaded from QuieTek Corporation’s Web Site :http://www.quietek.com/tw/ctg/cts/accreditations.htm The address and introduction of QuieTek Corporation’s laboratories can be founded in our Web site : http://www.quietek.com/ If you have any comments, Please don’t hesitate to contact us. Our contact information is as below: HsinChu Testing Laboratory : No.75-2, 3rd Lin, Wangye Keng, Yonghxing Tsuen, Qionglin Shiang, Hsinchu County 307, Taiwan, R.O.C. TEL:+886-3-592-8858 / FAX:+886-3-592-8859 E-Mail : [email protected] LinKou Testing Laboratory : No.5-22, Ruishukeng, Linkou Dist., New Taipei City 24451, Taiwan, R.O.C. TEL : 886-2-8601-3788 / FAX : 886-2-8601-3789 E-Mail : [email protected] Suzhou Testing Laboratory : No.99 Hongye Rd., Suzhou Industrial Park Loufeng Hi-Tech Development Zone., SuZhou, China TEL : +86-512-6251-5088 / FAX : 86-512-6251-5098 E-Mail : [email protected] Taiwan R.O.C. :BSMI, NCC, TAF Germany :TUV Rheinland Norway :Nemko, DNV USA :FCC Japan :VCCI China :CNAS Report No.: 1440261R-HP-US-P07V01 Page: 4 of 80 TABLE OF CONTENTS Description Page 1. General Information .................................................................................................... 6 1.1. EUT Description ......................................................................................................... 6 1.2. Mode of Operation ...................................................................................................... 7 1.3. Tested System Details ................................................................................................ 8 1.4. Configuration of Tested System .................................................................................. 9 1.5. EUT Exercise Software ............................................................................................. 10 2. Technical Test ........................................................................................................... 11 2.1. Summary of Test Result ............................................................................................ 11 2.2. Test Environment ...................................................................................................... 12 3. Peak Output Power .................................................................................................. 13 3.1. Test Equipment ......................................................................................................... 13 3.2. Test Setup................................................................................................................. 14 3.3. Limit .......................................................................................................................... 14 3.4. Test Procedure ......................................................................................................... 14 3.5. Uncertainty ............................................................................................................... 16 3.6. Test Result ................................................................................................................ 17 4. Modulation Characteristic ......................................................................................... 22 4.1. Test Equipment ......................................................................................................... 22 4.2. Test Setup................................................................................................................. 22 4.3. Limit .......................................................................................................................... 22 4.4. Uncertainty ...............................................................................................................…
Text truncated - open the document above for the full version.
Test Photograph for 22&24 Description: ERP Test Setup Description: Substitution Antenna for ERP Test Description: EIRP Test Setup Description: Substitution Antenna for EIRP Test Test Setup Photograph for SAR Test Setup Photographs Body SAR Back 15mm Body SAR Front 15mm Body SAR Front 15mm with ECG cable Depth of the liquid in the phantom – Zoom in Note: The position used in the measurements were according to IEEE 1528 – 2003
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 6 | 24E | 1.85 GHz - 1.91 GHz | 295.00 mW | 4M23F9W | 64 Hz |