FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

ยฉ 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. TCL Communication Ltd./
  3. 2ACCJB248

2ACCJB248GSM Mobile phone

TCL Communication Ltd.

Application Details

Equipment Class
PCE - PCS Licensed Transmitter held to ear
Date of Grant
May 26, 2026
Application Purpose
Original Equipment
Equipment Note
GSM Mobile phone
Frequency Range
824.20000000 - 848.80000000
Company
TCL Communication Ltd.
Country
China

Documents & Files

Select a file to view

Attestation Statements

โ†—
โ†—

Cover Letter(s)

โ†—
โ†—

ID Label/Location Info

โ†—

RF Exposure Info

โ†—
โ†—
โ†—
โ†—
โ†—
โ†—
โ†—
โ†—
โ†—

Test Report

โ†—
โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

TCL Communication Ltd. To: Federal Communications Commission Date: 2026-05-18 7435 Oakland Mills Road Columbia, MD 21046 USA Attestation Section 2.911(d)(5)(i) and Section 2.911(d)(5)(ii) (KDB 986446 D01 Covered Equipment) Section 2.911(d)(5)(i) TCL Communication Ltd. (โ€œthe applicantโ€) certifies that the equipment for which authorization is sought is not โ€œcoveredโ€ equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Section 2.911(d)(5)(ii) TCL Communication Ltd. (โ€œthe applicantโ€) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing โ€œcoveredโ€ equipment. Type of Equipment subject to FCC Certification: GSM Mobile phone FCC ID: 2ACCJB248 If you have any questions, please feel free to contact me Contact Person: Ting Wanag Position in the Company: NA Date of Signature: 2026-05-18 ___________________________ Signatory (signature of the applicant)

Attestation Statements

Page 1 of 1 TO: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA ATTENTION: FCC Certification โ€“ Section 2.911(d)(7) Information Designated U.S. Agent Company Name: TCT Mobile (US) Inc. Contact Name: Yao Dai Street Address: 189 Technology Drive City/Province/Zip: Irvine, CA 92618 Telephone No: 1-855-368-0829 Email: [email protected] FRN #: 0033429465 This letter is to confirm that we (โ€œthe Designated U.S. Agent) have accepted the responsibility to act as the Designated U.S. Agent for Service of Process as required by section 47 CFR 2.911(d)(7) on behalf of the Applicant noted below. U.S. Agent Signature: Date: October 11, 2025 Signed by (Printed Name/Title): Yao Dai / Technical Acceptance Manager The Applicant acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information above changes. Applicant Company name: TCL Communication Ltd. Grantee Code: 2ACCJ FRN: 0031833205 Contact Name: Wang Ting Street Address: 5/F, Building 22E, 22 Science Park East Avenue, Hong Kong Science Park, Shatin, NT, Hong Kong City/Province/Zip: Hongkong Telephone No: +86 13502294537 Email: [email protected] Applicant Signature: Date: 2025-10-11 Signed by (Printed Name/Title): Wang Ting / Product Certification Manager

Cover Letter(s)

TCL Communication Ltd. Date: 2026-05-18 To: Federal Communications Commission, Authorization & Evaluation Division, 7435 Oakland Mills Road, Columbia, MD 21046 To Whom It May Concern: The TCL Communication Ltd. the undersigned, hereby authorizes Mrs. Wendy Zhan from Shenzhen Morlab Communications Technology Co., Ltd., to act on the behalf of the TCL Communication Ltd. solely in matters relating to the application for an FCC equipment authorization for FCC ID: 2ACCJB248 including the signing of documents in connection with this Application. Necessary acts carried out Shenzhen Morlab Communications Technology Co., Ltd. on our behalf of the TCL Communication Ltd. in connection with the Application shall have the same effect as acts of the TCL Communication Ltd. also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Thank you for your attention to this matter. Yours Sincerely, Signatory: Contact name: Ting Wang Tel: +8613502294537 Email: [email protected] Company name: TCL Communication Ltd.

Cover Letter(s)

TCL Communication Ltd. Date: 2026-05-18 To: Federal Communications Commission, Authorization & Evaluation Division, 7435 Oakland Mills Road, Columbia, MD 21046 Re: Request of Confidentiality for FCC ID: 2ACCJB248 To Whom it may concern: Pursuant to sections 0.457 and 0.459 of Commissionโ€™s Rules(CFR 47), and Section 552(b)(4) of the Freedom of Information Act, TCL Communication Ltd. hereby requests confidentiality and treatment of certain information accompanying this application. The materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. We are also hereby request Short-Term Confidentiality till date 05/18/2026 as outlined in Public Notice DA04-1705. This provision will give TCL Communication Ltd. temporary confidentiality of commercially sensitive information prior to product release. The requested Permanent and Short-Term Confidential exhibits are listed as follows: PERMANENT AND SHORT-TERM CONFIDENTIAL LIST Exhibit Description PERMANENT 1 Block Diagram 2 Operational Description 3 Schematics 4 BOM 5 Tune up SHORT-TERM 6 External Photos 7 Internal Photos 8 Test-Setup Photos 9 User Manual The Applicant understands that pursuant to Rule 0.457, disclosure of this application and all accompanying documentations, where applicable, will not be made public before the date of the Grant for this application. Signatory Contact name: Ting Wang Tel: +8613502294537 Email: [email protected] Company name: TCL Communication Ltd.

RF Exposure Info

MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.๏ผšSZ26040008S01 Annex C Plots of System Performance Check Test Laboratory: Shenzhen Morlab Communications Technology Co., Ltd. Date: 2026/4/17 System Check_900MHz Communication System: UID 0, CW (0); Frequency: 900 MHz;Duty Cycle: 1:1 Medium: HSL_900 Medium parameters used: f = 900 MHz; ฯƒ = 0.964 S/m; ฮต r = 40.752; ฯ = 1000 kg/m 3 Ambient Temperature๏ผš23.2 ยฐC; Liquid Temperature๏ผš22.1 ยฐC DASY5 Configuration: - Probe: EX3DV4 - SN3823; ConvF(9.01, 9.01, 9.01) @ 900 MHz; Calibrated: 2026/1/7 - Sensor-Surface: 2mm (Mechanical Surface Detection) - Electronics: DAE4 Sn480; Calibrated: 2026/1/7 - Phantom: SAM 2; Type: QD000P40CC; Serial: TP:1464 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) CW900/Area Scan (71x71x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 4.32 W/kg CW900/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 43.68 V/m; Power Drift = 0.03 dB Peak SAR (extrapolated) = 9.18 W/kg SAR(1 g) = 2.69 W/kg; SAR(10 g) = 1.7 W/kg Smallest distance from peaks to all points 3 dB below = 15.8 mm Ratio of SAR at M2 to SAR at M1 = 65.2% Maximum value of SAR (measured) = 4.59 W/kg 0 dB = 4.59 W/kg = 5.80 dBW/kg MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.๏ผšSZ26040008S01 Test Laboratory: Shenzhen Morlab Communications Technology Co., Ltd. Date: 2026/4/17 System Check_1800MHz Communication System: UID 0, CW (0); Frequency: 1800 MHz;Duty Cycle: 1:1 Medium: HSL_1800 Medium parameters used: f = 1800 MHz; ฯƒ = 1.365 S/m; ฮต r = 39.615; ฯ = 1000 kg/m 3 Ambient Temperature๏ผš23.2 ยฐC; Liquid Temperature๏ผš22.1 ยฐC DASY5 Configuration: - Probe: EX3DV4 - SN3823; ConvF(7.96, 7.96, 7.96) @ 1800 MHz; Calibrated: 2026/1/7 - Sensor-Surface: 2mm (M echanical Surface Detection) - Electronics: DAE4 Sn480; Calibrated: 2026/1/7 - Phantom: SAM 2; Type: QD000P40CC; Serial: TP:1464 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) CW1800/Area Scan (81x81x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 11.7 W/kg CW1800/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 89.4 V/m; Power Drift = -0.08 dB Peak SAR (extrapolated) = 18.8 W/kg SAR(1 g) = 9.94 W/kg; SAR(10 g) = 5.29 W/kg Smallest distance from peaks to all points 3 dB below = 9.6 mm Ratio of SAR at M2 to SAR at M1 = 54.7% Maximum value of SAR (measured) = 11.3 W/kg 0 dB = 11.3 W/kg = 10.25 dBW/kg MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.๏ผšSZ26040008S01 Test Laboratory: Shenzhen Morlab Communications Technology Co., Ltd. Date: 2026/4/17 System Check_2000MHz Communication System: UID 0, CW (0); Frequency: 2000 MHz;Duty Cycle: 1:1 Medium: HSL_2000 Medium parameters used: f = 2000 MHz; ฯƒ = 1.425 S/m; ฮต r = 39.425; ฯ = 1000 kg/m 3 Ambient Temperature๏ผš23.2 ยฐC; Liquid Temperature๏ผš22.1 ยฐC DASY5 Configuration: - Probe: EX3DV4 - SN3823; ConvF(7.63, 7.63, 7.63) @ 2000 MHz; Calibrated: 2026/1/7 - Sensor-Surface: 2mm (Mechanical Surface Detection) - Electronics: DAE4 Sn480; Calibrated: 2026/1/7 - Phantom: SAM 2; Type: QD000P40CC; Serial: TP:1464 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) CW2000/Area Scan (81x81x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 12.1 W/kg CW2000/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 91.11 V/m; Power Drift = -0.04 dB Peak SAR (extrapolated) = 19.8 W/kg SAR(1 g) = 10.34 W/kg; SAR(10 g) = 5.36 W/kg Smallest distance from peaks to all points 3 dB below = 11.2 mm Ratio of SAR at M2 to SAR at M1 = 54% Maximum value of SAR (measured) = 11.8 W/kg 0 dB = 11.8 W/kg = 10.63 dBW/kg MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.๏ผšSZ26040008S01

RF Exposure Info

MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.๏ผšSZ26040008S01 Annex D Plots of Maximum SAR Test Results Test Laboratory: Shenzhen Morlab Communications Technology Co., Ltd. Date: 2026/4/17 GSM850_GPRS(2 TX slots)_Left Cheek_Ch251 Communication System: UID 0, GSM850(class 10) (0); Frequency: 848.8 MHz;Duty Cycle: 1:4.15 Medium: HSL_900 Medium parameters used: f = 849 MHz; ฯƒ = 0.911 S/m; ฮต r = 40.658; ฯ = 1000 kg/m 3 Ambient Temperature๏ผš23.2 ยฐC; Liquid Temperature๏ผš22.1 ยฐC DASY5 Configuration: - Probe: EX3DV4 - SN3823; ConvF(9.43, 9.43, 9.43) @ 848.8 MHz; Calibrated: 2026/1/7 - Sensor-Surface: 2mm (Mechanical Surface Detection) - Electronics: DAE4 Sn480; Calibrated: 2026/1/7 - Phantom: SAM 2; Type: QD000P40CC; Serial: TP:1464 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Ch251/Area Scan (61x81x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 1.39 W/kg Ch251/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 10.45 V/m; Power Drift = -0.03 dB Peak SAR (extrapolated) = 1.48 W/kg SAR(1 g) = 1.1 W/kg; SAR(10 g) = 0.792 W/kg Smallest distance from peaks to all points 3 dB below: Larger than measurement grid (> 16 mm) Ratio of SAR at M2 to SAR at M1 = 76.2% Maximum value of SAR (measured) = 1.31 W/kg 0 dB = 1.31 W/kg = 1.17 dBW/kg MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.๏ผšSZ26040008S01 Test Laboratory: Shenzhen Morlab Communications Technology Co., Ltd. Date: 2026/4/17 GSM1900_GPRS(2 TX slots)_Right Cheek_Ch661 Communication System: UID 0, GSM1900(Class 10) (0); Frequency: 1880 MHz;Duty Cycle: 1:4.15 Medium: HSL_2000 Medium parameters used: f = 1880 MHz; ฯƒ = 1.335 S/m; ฮต r = 39.828; ฯ = 1000 kg/m 3 Ambient Temperature๏ผš23.2 ยฐC; Liquid Temperature๏ผš22.1 ยฐC DASY5 Configuration: - Probe: EX3DV4 - SN3823; ConvF(7.61, 7.61, 7.61) @ 1880 MHz; Calibrated: 2026/1/7 - Sensor-Surface: 2mm (Mechanical Surface Detection) - Electronics: DAE4 Sn480; Calibrated: 2026/1/7 - Phantom: SAM 2; Type: QD000P40CC; Serial: TP:1464 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Ch661/Area Scan (61x81x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 0.115 W/kg Ch661/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 3.075 V/m; Power Drift = 0.11 dB Peak SAR (extrapolated) = 0.148 W/kg SAR(1 g) = 0.096 W/kg; SAR(10 g) = 0.058 W/kg Smallest distance from peaks to all points 3 dB below = 12.9 mm Ratio of SAR at M2 to SAR at M1 = 68.4% Maximum value of SAR (measured) = 0.104 W/kg 0 dB = 0.104 W/kg = -9.83 dBW/kg MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.๏ผšSZ26040008S01 Test Laboratory: Shenzhen Morlab Communications Technology Co., Ltd. Date: 2026/4/17 GSM850_GPRS(2 TX slots)_Back Side_10mm_Ch251 Communication System: UID 0, GSM850(class 10) (0); Frequency: 848.8 MHz;Duty Cycle: 1:4.15 Medium: HSL_900 Medium parameters used: f = 849 MHz; ฯƒ = 0.911 S/m; ฮต r = 40.658; ฯ = 1000 kg/m 3 Ambient Temperature๏ผš23.2 ยฐC; Liquid Temperature๏ผš22.1 ยฐC DASY5 Configuration: - Probe: EX3DV4 - SN3823; ConvF(9.43, 9.43, 9.43) @ 848.8 MHz; Calibrated: 2026/1/7 - Sensor-Surface: 2mm (Mechanical Surface Detection) - Electronics: DAE4 Sn480; Calibrated: 2026/1/7 - Phantom: SAM 2; Type: QD000P40CC; Serial: TP:1464 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Ch251/Area Scan (61x91x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 1.27 W/kg Ch251/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 36.96 V/m; Power Drift = -0.17 dB Peak SAR (extrapolated) = 1.32 W/kg SAR(1 g) = 1.01 W/kg; SAR(10 g) = 0.744 W/kg Smallest distance from peaks to all points 3 dB below: Larger than measurement grid (> 16 mm) Ratio of SAR at M2 to SAR at M1 = 76.5% Maximum value of SAR (measured) = 1.19 W/kg 0 dB = 1.19 W/kg = 0.76 dBW/kg MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.๏ผšSZ26040008S01 Test Laboratory: Shenzhen Morlab Communications Technology Co., Ltd. Date: 2026/4/17 GSM1900_GPRS(2 TX slots)_Back Side_10mm_Ch661 Communication System: UID 0, GSM1900(Class 10) (0); Frequency: 1880 MHz;Duty Cycle: 1:4.15 Medium: HSL_1800 Medium parameters used: f = 1880 MHz; ฯƒ = 1.335 S/m; ฮต r = 39.828; ฯ = 1000 kg/m 3 Ambient Temperature๏ผš23.2 ยฐC; Liquid Temperature๏ผš22.1 ยฐC DASY5 Configuration: - Probe: EX3DV4 - SN3823; ConvF(7.61, 7.61, 7.61) @ 1880 MHz; Calibrated: 2026/1/7 - Sensor-Surface: 2mm (Mechanical Surface Detection) - Electronics: DAE4 Sn480; Calibrated: 2026/1/7 - Phantom: SAM 2; Type: QD000P40CC; Serial: TP:1464 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Ch661/Area Scan (61x81x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 0.355 W/kg Ch661/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 6.195 V/m; Power Drift = -0.05 dB Peak SAR (extrapolated) = 0.527 W/kg SAR(1 g) = 0.300 W/kg; SAR(10 g) = 0.169 W/kg Smalโ€ฆ

Text truncated - open the document above for the full version.

RF Exposure Info

MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.๏ผšSZ26040008S01 Annex E Conducted Power Note: Conducted power unit: dBm The target power was recorded in the manufacturer's document. 128189251128189251 824.2 836.4 848.8824.2 836.4 848.8 32.28 32.25 32.26 33.00 23.28 23.25 23.26 24.00 32.33 32.35 32.30 33.00 23.33 23.35 23.30 24.00 30.48 30.51 30.50 31.50 24.48 24.51 24.5025.50 28.74 28.75 28.73 29.50 24.48 24.49 24.47 25.24 26.83 26.86 26.83 27.50 23.83 23.86 23.83 24.50 Max. 32.35Max. 24.51 512661810512661810 1850.2 1880 1909.81850.2 1880 1909.8 29.09 29.05 29.09 30.00 20.09 20.05 20.09 21.00 29.12 29.15 29.11 30.00 20.12 20.15 20.11 21.00 27.10 27.12 26.99 28.00 21.10 21.12 20.9922.00 25.21 25.24 25.14 26.00 20.95 20.98 20.88 21.74 23.25 23.27 23.15 24.00 20.25 20.27 20.15 21.00 Max. 29.15Max. 21.12 GSM850Burst Average Power (dBm)Frame-Average Power (dBm) TX Channel Frequency (MHz) GSM 1 Tx slot GPRS 1 Tx slot GPRS 2 Tx slots Tune-up Limit (dBm) Tune-up Limit (dBm) GPRS 3 Tx slots GPRS 4 Tx slots Mode AttenuatorCable Loss : 0.6 Date4/15 GSM1900Burst Average Power (dBm)Frame-Average Power (dBm) TX Channel Frequency (MHz) GSM 1 Tx slot GPRS 1 Tx slot Tune-up Limit (dBm) GPRS 2 Tx slots GPRS 3 Tx slots GPRS 4 Tx slots Mode AttenuatorCable Loss : 0.8 Date4/17 Tune-up Limit (dBm) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.๏ผšSZ26040008S01 Average power (dBm) Tune-up Limit Average power (dBm) Tune-up Limit Average power (dBm) Tune-up Limit CH 002402-2.23-3.00-4.10-5.00-5.91-6.50 CH 392441-2.71-3.50-6.06-7.00-6.41-7.50 CH 782480-3.21-3.00-5.65-6.50-5.44-6.50 BR / EDR Duty Cycle % 1Mbps2Mbps3Mbps 77.9546.846.77 ModeChannel Frequency (MHz) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.๏ผšSZ26040008S01

RF Exposure Info

MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.๏ผšSZ26040008S01 Annex F DASY Calibration Certificate

RF Exposure Info

Annual validation for test lab. Appendix Annual validation for Test Lab. General calibration information Date 2025.09.25 Test Laboratory ShenZhen Morlab Communications Technology Co., Ltd. Antenna serial No. D900V2-SN: 1d064 Antenna Parameters with Head TSL Impedance, transformed to feed point 48.82ฮฉ-2.61jฮฉ Return Loss -52.75dB General Antenna Parameters and Design Electrical Delay (one direction) 1.276 ns After long term use with 100W radiated power๏ผŒonly a slight warming of the dipole near the feed point can be measured The dipole is made of standard semirigid coaxial cable. The center conductor of the feeding line is directly connected to the second arm of the dipole. The antenna is therefore short-circuited for DC-signals. On some of the dipoles, small end caps are added to the dipole arms in order to improve matching when loaded according to the position as explained in the "Measurement Conditions" paragraph. The SAR data are not affected by this change. The overall dipole length is still according to the Standard No excessive force must be applied to the dipole arm๏ผŒ because they might bend or the soldered connections near the feed point may be damaged . Annual validation for test lab. Annual validation for test lab. Appendix Impedance Measurement Plot for Head TSL

RF Exposure Info

Annual validation for test lab. Appendix Annual validation for Test Lab. General calibration information Date 2025.09.25 Test Laboratory ShenZhen Morlab Communications Technology Co., Ltd. Antenna serial No. D1800V2-SN: 2d158 Antenna Parameters with Head TSL Impedance, transformed to feed point 50.74ฮฉ-9.14jฮฉ Return Loss -20.86dB General Antenna Parameters and Design Electrical Delay (one direction) 1.276 ns After long term use with 100W radiated power๏ผŒonly a slight warming of the dipole near the feed point can be measured The dipole is made of standard semirigid coaxial cable. The center conductor of the feeding line is directly connected to the second arm of the dipole. The antenna is therefore short-circuited for DC-signals. On some of the dipoles, small end caps are added to the dipole arms in order to improve matching when loaded according to the position as explained in the "Measurement Conditions" paragraph. The SAR data are not affected by this change. The overall dipole length is still according to the Standard No excessive force must be applied to the dipole arm๏ผŒ because they might bend or the soldered connections near the feed point may be damaged . Annual validation for test lab. Annual validation for test lab. Appendix Impedance Measurement Plot for Head TSL

RF Exposure Info

Annual validation for test lab. Appendix Annual validation for Test Lab. General calibration information Date 2025.09.25 Test Laboratory ShenZhen Morlab Communications Technology Co., Ltd. Antenna serial No. D2000V2-SN: 1050 Antenna Parameters with Head TSL Impedance, transformed to feed point 49.575ฮฉ+0.869jฮฉ Return Loss -40.252dB General Antenna Parameters and Design Electrical Delay (one direction) 1.276 ns After long term use with 100W radiated power๏ผŒonly a slight warming of the dipole near the feed point can be measured The dipole is made of standard semirigid coaxial cable. The center conductor of the feeding line is directly connected to the second arm of the dipole. The antenna is therefore short-circuited for DC-signals. On some of the dipoles, small end caps are added to the dipole arms in order to improve matching when loaded according to the position as explained in the "Measurement Conditions" paragraph. The SAR data are not affected by this change. The overall dipole length is still according to the Standard No excessive force must be applied to the dipole arm๏ผŒ because they might bend or the soldered connections near the feed point may be damaged . Annual validation for test lab. Annual validation for test lab. Appendix Impedance Measurement Plot for Head TSL

RF Exposure Info

NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.๏ผšSZ26040008S01 Page 1 of 46 TEST REPORT APPLICANT : TCL Communication Ltd. PRODUCT NAME : GSM Mobile phone MODEL NAME : A323E BRAND NAME : Alcatel FCC ID : 2ACCJB248 STANDARD(S) : FCC 47 CFR Part 2 (2.1093) IEEE 1528-2013 RECEIPT DATE : 2026-04-02 TEST DATE : 2026-04-17 ISSUE DATE : 2026-05-15 Edited by: Pang Siyu (Rapporteur) Approved by: Shen Junsheng (Supervisor) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.๏ผšSZ26040008S01 Page 2 of 46 DIRECTORY 1. Statement of Complianceยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 5 2. Technical Information ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 6 2.1. Applicant and Manufacturer Information ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 6 2.2. Equipment under Test (EUT) Description ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 6 2.3. Environment of Test Site/Conditions ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 7 3. Specific Absorption Rate (SAR) ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 8 3.1. Introductionยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 8 3.2. SAR Definition ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 8 4. RF Exposure Limits ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 9 4.1. Uncontrolled Environment ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 9 4.2. Controlled Environment ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 9 5. Applied Reference Documents ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 10 6. SAR Measurement System ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 11 6.1. E-Field Probe ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 12 6.2. Data Acquisition Electronics (DAE) ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 13 6.3. Robot ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 13 6.4. Measurement Server ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 14 6.5. Light Beam Unit ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 14 6.6. Phantom ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 14 6.7. Device Holder ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 15 6.8. Data Storage and Evaluation ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 16 6.9. Test Equipment List ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 18 7. Tissue Simulating Liquids ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 19 8. SAR System Verification ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 21 8.1. Purpose of System Performance Check ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 21 8.2. System Setup ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 21 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.๏ผšSZ26040008S01 Page 3 of 46 8.3. Validation Results ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 22 9. EUT Testing Position ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 24 9.1. Handset Reference Points ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 24 9.2. Positioning for Cheek / Touch ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 25 9.3. Positioning for Ear / 15ยบ Tilt ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 26 9.4. SAR Evaluation near the Mouth/Jaw Regions of the Phantom ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 26 9.5. Body-worn Configurations ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 27 10. Measurement Procedures ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 28 10.1. Spatโ€ฆ

Text truncated - open the document above for the full version.

Test Report

Antenna Test Data Repor Customer: Zeolite Project: F22428TCL Band๏ผšB2/B3/B5/B8 Engineer๏ผšYiLong Chen(15014546468) Date๏ผš2026-05-13 Shenzhen Ruixinda Communication Equipment Co., Ltd Address: Room 503, Building 211, Tairan Ninth Road, Tairan Industrial Zone, Chegongmiao, Futian District, Shenzhen 1. Test Project 2.Test Equipment Agilent 5071B ๏ผˆS Parameter๏ผˆRL/VSWR๏ผ‰Test Equipment๏ผ‰ Test Project Equipment 1. S Parameter 1. Return Loss(RL) 2. VSWR Network Analyzer๏ผš Agilent 5071B 2. RF Test ๏ผˆ2/3/4/5G๏ผ‰ 1. power 2. level 3.TRP/TIS Comprehensive Test๏ผš SP9500/CMW500/8960 Test Environment๏ผš Anechoic Chamber SP9500 ๏ผˆ5GTest Equipment๏ผ‰ Agilent 8960 ๏ผˆ2G/3G Test Equipment๏ผ‰ CMW 500 ๏ผˆ2G/3G/4GTest Equipment๏ผ‰ 3.TestEnvironment Microwave Anechoic Chamber 4.Test Steps Passive VSWR/RL Test Steps: 50ฮฉ Coaxial Cable 100mm Length Copper Pipe 5071B Network Analyzer Test Fixture Active TRP/TIS Test Steps๏ผš Open Computer OTA Test Software Open Turntable Switch And Reset To zero Open 8960/CMW500 Test Equipment Test mobile phone insert test SIM card and Put into the microwave darkroom to connect OTA Software automatic testing Output Data 5.Antenna Gain Frequency Max Gain Frequency Max Gain 824Mhz -0.08 2400Mhz -3.97 852Mhz 0.17 2450Mhz -3.47 880Mhz 0.28 2500Mhz -4.11 908Mhz -0.โ€ฆ

Text truncated - open the document above for the full version.

Contact Information

Applicant

Ting Wang
[email protected]Fax: +8675536612000-81722

Technical Contact

TCT Mobile (US) Inc.Yao Dai
[email protected]

189 Technology Dr. ยท Irvine, 92618 ยท United States

Test Firm

Shenzhen Morlab Communications Technology Co. Ltd.Mr. Su Feng
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
122H824.2 MHz - 848.8 MHz1.117 W247KGXW0.027ppm
224E1.85 GHz - 1.91 GHz760.00 mW248KGXW0.011ppm
Confidentiality
Long Term
Grant Notes
Output power listed for GSM850 is maximum ERP. <br> Output power listed for PCS1900 is maximum EIRP. <br> This device contains functions that are not operational in U.S. Territories; this filing is only applicable for U.S. operations. <br> This device has integrated DSS and PCE transmitters certified under the same FCC ID. <br> SAR compliance for body-worn operating configurations is limited to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for Head, body-worn accessory and simultaneous transmission use conditions are 1.39 W/kg, 1.27 W/kg and 1.28 W/kg, respectively.