FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Beijing Polycon Medical Engineering Company/
  3. 2ACCSRC2200

2ACCSRC2200XAE Remote controller

Beijing Polycon Medical Engineering Company
XAE Remote controller - FCC ID 2ACCSRC2200 - Beijing Polycon Medical Engineering Company
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Jun 05, 2014
Application Purpose
Original Equipment
Date of Application
Jun 05, 2014
Equipment Note
XAE Remote controller
Frequency Range
433.90000000 - 433.90000000
Company
Beijing Polycon Medical Engineering Company
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

XAE Remote Controller User Manual 1、Product Introduction RC 2200 remote controller easy to operate, suitable for Motorized Ceiling Suspension Tube Stand (C2200) and Motorized Wall Stand (S1800) motion control,Example as follows: Model Number: RC 2200 3、Wireless Control Pad Button Functions No. Picture Function description 1 Emergency STOP Key: by pressing the STOP key all movement will be stopped. Once pressed, STOP icon on touch screen will flash. Press again STOP icon will stop flashing and operate in normal mode. 2 Extensionkey 3 API control key (option) 4 Extensionkey 5、6 Detector up / down movement - pressing and hold, the detector move up or down, release the key to stop motion. Touch the key when the key was red . 7、8 Press and hold, X-ray tube rotates in direction of counterclockwise or clockwise. 9 Table position Key B‐‐ Press and hold, the tubewill be automaticallymoved to thepre‐setposition , runninga redflashingkey to resumenormalposition is reached. 10 Chest positionKey 1 -- Press and hold , the tube will be automatically moved to the pre-set position at SID=1m. 11 Table position Key A‐ Press and hold ,the tubewill automaticallymoves to thepre‐setposition, runninga redflashingkey to resumenormalposition is reached. 12 Chest positionKey 2 -- Press and hold , the tube will be automatically moved to the pre-set position at SID=1.8m. 4、Battery requirements The remote controller battery specification is A23 Size E23A +12V The RC 1600 remote controller to make uc arm to position up/down, rotation, SID adjustment and rotation of detector., Example as follows: Model Number: RC 1600 Wireless Control Pad Button Functions No. Picture Function description 1 Emergency stop switch : press stop switch will be stop any movement. Once touch switch and the picture will be flash. Touch it again picture will stable and operate in normal situation. 2 Speed key. Fast speed and lower speed. 3 Arm movement in up/down direction. Stop in max. top and min. bottom. 4 U arm rotation key, arm move to 0 º and 90 º will stop once and if you keep to press key the movement will be continue. The u arm will move up when arm rotate to close floor. U arm rotate from 0 º to+ 120 º /-30 º. Attention : The over rotation will be mangle the cables in the arm. 5 The press keys for rotation detector. Move in clockwise +2 5 º and anticlockwise -45 º. It will be stop at 0 ºposition . It will stop once when move to 0 º, if keep press key the movement will be continue. 6 SID movement control. The movement stop when the key release.It will stop at 1 m and 1.8 m position. 7 The keep touch key for chest position (1 m stand position). 8 Keep touch key for table position. Any time loosen the key the movement will be stop. The high of detector position may re-set through the setting program. Battery requirements The remote controller battery specification is A23 Size E23A +12V Declaration of Conformity This device complies with Part 15 of the FCC Rules. Its operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note: This product has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This product generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this product does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help.

Cover Letter(s)

北京宝利康医学工程公司 北京海淀区阜外亮甲店一号九号楼 Tel:(010)88110881 Beijing Polycon Medical #9,No.1 Fu Wai Liang Jia Dian Str. Fax:(010)88148957 1 *WE (Beijing Polycon Medical Engineering Company. ) HEREBY DECLARED THAT Our product Product Description XAE Remote controller Manufacturer’s Name Beijing Polycon Medical Engineering Company. Manufacturer’s Address No. 1 Fu Wai Liang Jia Dian Str.,Hai Dian Qu, Beijing P. R. China Model Numbers: RC2200 (Test Model) and RC1600 Note: The definition of identical should be “electrically identical”. A device will be considered to be electrically identical if no changes are made to the devices’ schematics, board layouts, component layouts, chip sets, resistors and all other electrical aspects of the device are identical. Differences and similarities between RC2200 and RC1600 Mode RC2200 RC1600 Block Diagram same same Schematic Diagram same same Circuit Description same same BOM List same same Key-press icon different different Signature (签字): Printed Name (姓名): Meng Zhang Position/Title (职位): Vice Manager Contact Number (联系电话): 01088110881

Cover Letter(s)

2014-05-08 Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: 2ACCSRC2200 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Block Diagram Block Diagram.pdf Schematic Diagram Schematic.pdf Circuit Description Operation Description.pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Yours Sincerely, Company Name: Beijing Polycon Medical Engineering Company. Contact name: Meng Zhang Signature of applicant:

Cover Letter(s)

FCC ID: 2ACCSRC2200 POWER OF ATTORNEY (2014-05-08) Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 To Whom It May Concern: We, the undersigned, hereby authorize _Eddy Zong from SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by Eddy Zong from SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd on our behalf shall have the same effect as acts of our own. This authorization expires on (2015-05-07). This is to advise that we are in full compliance with the Anti-Drug Abuse Act. We, (Beijing Polycon Medical Engineering Company), are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section.

External Photos

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. Page: 1 of 4 Page 1 of 4 RC2200 _External Photos-FCC Application No.: SHEM1311002298RF Applicant: Beijing Polycon Medical Engineering Company. Address of Applicant: No. 1 Fu Wai Liang Jia Dian Str., Hai Dian Qu, Beijing P. R. China Equipment Under Test (EUT): Product Name: XAE Remote controller Model No.: RC2200 Add Model No.: RC1600 FCC ID: 2ACCSRC2200 SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. Page: 2 of 4 Page 2 of 4 1 Contents Page 1 CONTENTS.......................................................................................................... 2 2 EXTERNAL PHOTOS ........................................................................................ 3 SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. Page: 3 of 4 Page 3 of 4 2 External Photos SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. Page: 4 of 4 Page 4 of 4 End

Internal Photos

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. Page: 1 of 4 Page 1 of 4 RC2200 _Internal Photos-FCC Application No.: SHEM1311002298RF Applicant: Beijing Polycon Medical Engineering Company. Address of Applicant: No. 1 Fu Wai Liang Jia Dian Str., Hai Dian Qu, Beijing P. R. China Equipment Under Test (EUT): Product Name: XAE Remote controller Model No.: RC2200 Add Model No.: RC1600 FCC ID: 2ACCSRC2200 SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. Page: 2 of 4 Page 2 of 4 1 Contents Page 1 CONTENTS .............................................................................................. 2 2 INTERNAL PHOTOS ............................................................................... 3 SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. Page: 3 of 4 Page 3 of 4 2 Internal Photos SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. Page: 4 of 4 Page 4 of 4 E EE En nn nd dd d

Test Report

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. 588 West Jindu Road,Songjiang District,Shanghai,China Telephone: +86 (0) 21 6191 5666 Fax: +86 (0) 21 6191 5678 [email protected] Report No.: SHEM131100229801 Page: 1 of 20 Tony Wu E&E Section Manager SGS-CSTC (Shanghai) Co., Ltd. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. All test results in this report can be traceable to National or International Standards. This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only 1 Cover Page FCC REPORT Application No.: SHEM1311002298RF Applicant: Beijing Polycon Medical Engineering Company. FCC ID: 2ACCSRC2200 Equipment Under Test (EUT): NOTE: The following sample(s) submitted was/were identified on behalf of the client as Product Name: XAE Remote controller Model No.: RC2200 Added Model: RC1600 Standards: FCC PART 15 Subpart C: 2013 Date of Receipt: November 19, 2013 Date of Test: March 24, 2014 to April 23, 2014 Date of Issue: May 26, 2014 Test Result : PASS * *In the configuration tested, the EUT detailed in this report complied with the standards specified above. SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. Report No.: SHEM131100229801 Page: 2 of 20 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 2 Version Revision Record Version Chapter Date Modifier Remark 00 May 26, 2014 Original Authorized for issue by: Engineer Eddy Zong Print Name Clerk Susie Liu Print Name Reviewer Keny Xu Print Name SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. Report No.: SHEM131100229801 Page: 3 of 20 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 3 Test Summary Test Item Test Requirement Test method Result Antenna Requirement 47 CFR Part 15, Subpart C Section 15.203 ANSI C63.10(2009) PASS AC Power Line Conducted Emission 47 CFR Part 15, Subpart C Section 15.207 ANSI C63.10(2009) N/A Field Strength of the Fundamental Signal 47 CFR Part 15, Subpart C Section 15.231 (e) ANSI C63.10(2009) PASS Spurious Emissions 47 CFR Part 15, Subpart C Section 15.231 (e)/15.209 ANSI C63.10(2009) PASS 2…

Text truncated - open the document above for the full version.

Test Setup Photos

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. Page: 1 of 3 Page 1 of 3 RC2200 _Test Setup Photos-FCC Application No.: SHEM1311002298RF Applicant: Beijing Polycon Medical Engineering Company. Address of Applicant: No. 1 Fu Wai Liang Jia Dian Str., Hai Dian Qu, Beijing P. R. China Equipment Under Test (EUT): Product Name: XAE Remote controller Model No.: RC2200 Add Model No.: RC1600 FCC ID: 2ACCSRC2200 SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. Page: 2 of 3 Page 2 of 3 1 Contents Page 1 CONTENTS............................................................................................................... 2 2 EQUIPMENT UNDER TEST PICTURES ............................................................. 3 2.1 Radiated Emission Test Setup .......................................................................... 3 SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. Page: 3 of 3 Page 3 of 3 2 EQUIPMENT UNDER TEST PICTURES 2.1 Radiated Emission Test Setup Below 1GHz: Above 1GHz: End

Contact Information

Applicant

Meng Zhang
[email protected]861088110881Fax: 861088148957

Test Firm

SGS-CSTC Standards Technical Services Co.,Ltd.Zenger Zhang
[email protected]86(0)2161915654Fax: 8602161915655

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.9 MHz - 433.9 MHz-
Confidentiality
Long Term