FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. DigiLife Technologies Co., Ltd./
  3. 2ACFI485WM

2ACFI485WMCar Camcorder

DigiLife Technologies Co., Ltd.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Dec 18, 2025
Application Purpose
Original Equipment
Equipment Note
Car Camcorder
Frequency Range
2412.00000000 - 2462.00000000
Company
DigiLife Technologies Co., Ltd.
Country
Taiwan

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Rev 1/26/2023 Digilife Technologies Co., Ltd. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2025-10-14 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID: 2ACFI485WM Applicant FRN: 0023645351 [Digilife Technologies Co., Ltd.] (“the applicant”) certifies that, as of the date of the filing of the application, [FCC US Agent, LLC]is our designated U.S. agent for service of process for the above referenced FCC ID. [Digilife Technologies Co., Ltd.] accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. [FCC US Agent, LLC] accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Name: [FCC US Agent, LLC] U.S. Agent FRN: [0033402884] Address: [3722 Illinois Avenue, Saint Charles, IL, 60174, USA] Contact Person: [Tim Payne] Tel.: [708-571-3148] Email: [[email protected]] Sincerely, Digilife Technologies Co., Ltd. [FCC US Agent, LLC] Joan Chao [Tim Payne] [Insert Applicant signature] [U.S. Agent signature]

Attestation Statements

Rev 1/26/2023 Digilife Technologies Co.,LTD Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: Sep.08,2025 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2ACFI485WM [Digilife Technologies Co.,LTD.] (“the applicant”) certifies that the equipment for which authorization is sought is not“covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. [Digilife Technologies Co.,LTD] (“the applicant”) certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus softwarepursuant toDA-24-886 andKDB 986446D01 Covered Equipment Guidancesection B(2a). Device is inherently compliant based on hardware limitations or software controls. or A Software Bill of Materials (SBOM) is provided to the TCB for review, and The end-user or third parties cannot install additional software on this device. Sincerely, (Applicantsignature) Joan Chao (Applicant printed name) Rev 1/26/2023 Digilife Technologies Co.,LTD Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 09-05-2025 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID:2ACFI485WM [Digilife Technologies Co.,LTD.] (“the applicant”) certifies that, as of the date of the filing of theapplication, the applicant is not identified on the Covered List (as a specificallynamed entity or any of its subsidiaries or affiliates) as an entity producing “covered”equipment. Sincerely, (Applicantsignature) Joan Chao

Cover Letter(s)

C:\Users\tp00186\Desktop\f485s pro FCC\FCC POA Letter.docx Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Date: 2025/9/5 SUBJECT: FCC Application for 2ACFI485WM To Whom It May Concern: We, the undersigned, hereby authorize ___ Sunny Lu ___ at __Audix Technology(Shenzhen) Co., Ltd.___ on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by __Sunny Lu______ on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti- Drug Abuse Act. We, the applicant, are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Regards, (signature) Joan Chao

Cover Letter(s)

Rev 11/20/07 Digilife Technologies Co.,LTD. Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: 2ACFI485WM Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type Block Diagram, Schematics, Operational Description, Parts List, PCB Layout The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Pursuant to DA04-1705 June 15, 2004 of the Commission’s public notice, we also request 180 days temporary confidential treatment of information accompanying this application as outlined below: Exhibit Type External Photos, Internal Photos, Test Setup Photos, Manual Sincerely, Joan Chao

RF Exposure Info

AUDIX Technology (Shenzhen) Co., Ltd. Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25207 Page 1 of 3 Maximum Permissive Exposure FOR CERTIFICATION On Behalf of Digilife Technologies Co., Ltd. Car Camcorder f485s pro; f480u; f480u plus; f485s; f485s plus FCC ID: 2ACFI485WM Brand : HP Prepared for : Digilife Technologies Co., Ltd. 13F., No.7, Dexing W.Rd., Shilin Dist., Taipei City 11158, Taiwan Prepared By : Audix Technology (Shenzhen) Co., Ltd. No. 6, Kefeng Road, Science & Technology Park, Nanshan District , Shenzhen, Guangdong, China Tel: (0755) 26639496 Report Number : ACS-F25207 Date of Test : Aug.26, 2025 Date of Report : Sep.02, 2025 AUDIX Technology (Shenzhen) Co., Ltd. Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25207 Page 2 of 3 1.According to FCC CFR 47 §1.1310, the criteria listed in the following table shall be used to evaluate the environmental impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b). Table 1 Limits for Maximum Permissible Exposure Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Average Time (Minutes) (A)Limits for Occupational / Control Exposures (f = frequency) 30-30061.4 0.163 1.0 6 300-1500--- --- f/300 6 1500-100,000 --- --- 5.0 6 (B)Limits for General Population / Uncontrolled Exposures (f = frequency) 30-30027.5 0.073 0.2 30 300-1500--- --- f/1500 30 1500-100,000 --- --- 1.0 30 2.MPE Calculation APTIV Services Deutschland GmbH declares that the product described above has been evaluated and found to comply with the RF exposure limits for humans, as specified based on ANSI/FCC recommendation. RF Exposure Calculations: S = (P * G) / (4* π * r^2) or r = √(P * G) / (4 * π * S) AUDIX Technology (Shenzhen) Co., Ltd. Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25207 Page 3 of 3 3.MPE Result Based on safety distance (r) 20cm, the antenna gain (G) numerical as below: EUT: Car Camcorder M/N: f485s pro Test date: 2025-08-26 Pressure: 102.6±1.0 kpa Humidity: 54.4±3.0% Tested by: Epoch Test site: RF site Temperature: 23.6±0.6°C Test Mode Output Power (dBm) Output Power (mW) Antenna Gain (dBi) Antenna Gain (Linear) MPE (mW/cm2) WIFI2.4G 3.40 2.19 2.00 1.58 0.00069 Conclusion:Pass

Test Report

Approval sheet Page 1 of 9 ASC_RFANT5220110A2T_V03 May. 2013 RFANT Series – RoHS Compliance MULTILAYER CERAMIC ANTENNA Halogens Free Product 2.4 GHz ISM Band Working Frequency P/N: RFANT5220110A2T *Contents in this sheet are subject to change without prior notice. Approval sheet Page 2 of 9 ASC_RFANT5220110A2T_V03 May. 2013 FEATURES 1. Surface Mounted Devices with a small dimension of 5.2 x 2.0 x 1.1 mm 3 meet future miniaturization trend. 2. Embedded and LTCC (Low Temperature Co-fired Ceramic) technology is able to future integrate with system design as well as beautifying the housing of final product. 3. High Stability in Temperature / Humidity Change APPLICATIONS 1. Bluetooth 2. Wireless LAN 3. HormRF 4. ISM band 2.4GHz wireless applications CONSTRUCTION Figure Symbol Dimension (mm) L 5.20 ± 0.20 W 2.00 ± 0.20 T 1.15 ± 0.10 A 0.40 ± 0.25 PIN Connection 1 Feeding 2 Identification Mark 3 Soldering terminal P1 P3 P2 Approval sheet Page 3 of 9 ASC_RFANT5220110A2T_V03 May. 2013 ELECTRICAL CHARACTERISTICS RFANT5220110A2T Specification Working Frequency Range 2.4 GHz ~ 2.5GHz Gain 2 dBi (Typical) VSWR 2 max. Polarization Linear Azimuth Beamwidth Omni-directional Impedance 50Ω Rated Power (max.) 3 Watts Maximum Input Power 5 Watts for 5 minutes Operation Temperature -40 ̊C ~ +85 ̊C Remark: The specification is defined based on the test board dimension as in below SOLDER LAND PATTERN DESIGN Figure To 50Ω RF I/O GROUND 6.4 1.0 1.0 4.4 2.0 Ground Soldering Pad 50 ΩTransmission Line Unit : mm 1.0 To 50Ω RF I/O GROUND 6.46.4 1.0 1.0 4.4 2.0 Ground Soldering Pad 50 ΩTransmission Line Unit : mm 1.0 Approval sheet Page 4 of 9 ASC_RFANT5220110A2T_V03 May. 2013 Antenna on Test Board ( FR4 Thickness 0.8mm) Antenna S11 on Test Board Empty Area 50Ω ΩΩ ΩFeed line GROUND 30x18 mm 2.0mm 2.5mm 18mm WTC B Empty Area 18x9 mm 1mm Empty Area 50Ω ΩΩ ΩFeed line GROUND 30x18 mm 2.0mm 2.5mm 18mm WTC B WTC B Empty Area 18x9 mm 1mm -14.96 dB @ 2.40 GHz -22.21 dB @ 2.45 GHz -10.26 dB @ 2.50 GHz Approval sheet Page 5 of 9 ASC_RFANT5220110A2T_V03 May. 2013 RADIATION PATTERN Radiation Pattern and Gain were dependent on measurement board design. The specification of RFANT5220110A2T antenna was measured based on the PCB size and installation position as shown in the below figure Test Board Vertical Horizontal Y - Z Plane Average Gain= 1.01 dBi -40 -30 -20 -10 0 0 30 60 90 120 150 180 210 240 270 300 330 Peak Gain = 3.12dBi Average Gain = 0.29dBi -40 -30 -20 -10 0 0 30 60 90 120 150 180 210 240 270 300 330 Peak Gain=-0.33dBi Average Gain=-7.21dBi X - Z Plane Average Gain= -1.737 dBi -40 -30 -20 -10 0 0 30 60 90 120 150 180 210 240 270 300 330 Peak Gain= -2.91 dBi Average Gain= -9.27dBi X Cut -40 -30 -20 -10 0 0 30 60 90 120 150 180 210 240 270 300 330 Peak Gain= 2.88 dBi Average Gain= -2.58 dBi X - Y Plane Average Gain= -2.799 dBi -40 -30 -20 -10 0 0 30 60 90 120 150 180 210 240 270 300 330 Peak Gain= -1.73 dBi Average Gain= -8.07 dBi -40 -30 -20 -10 0 0 30 60 90 120 150 180 210 240 270 300 330 Peak Gain= 0.85 dBi Average Gain= -4.33 dBi x Y Z x Y x Y Z Y Z Y Z X Z X Approval sheet Page 6 of 9 ASC_RFANT5220110A2T_V03 May. 2013 RELIABILITY TEST Test item Test condition / Test method Specification Solderability JIS C 0050-4.6 JESD22-B102D *Solder bath temperature:235 ± 5°C *Immersion time:2 ± 0.5 sec Solder:Sn3Ag0.5Cu for lead-free At least 95% of a surface of each terminal electrode must be covered by fresh solder. Leaching (Resistance to dissolution of metallization) IEC 60068-2-58 *Solder bath temperature:260 ± 5°C *Leaching immersion time:30 ± 0.5 sec Solder : SN63A Loss of metallization on the edges of each electrode shall not exceed 25%. Resistance to soldering heat JIS C 0050-5.4 *Preheating temperature:120~150°C, 1 minute. *Solder temperature:270±5°C *Immersion time:10±1 sec Solder:Sn3Ag0.5Cu for lead-free Measurement to be made after keeping at room temperature for 24±2 hrs No mechanical damage. Electrical specification shall satisfy the descriptions in electrical characteristics under the operational temperature range within -40 ~ 85°C. Loss of metallization on the edges of each electrode shall not exceed 25%. Drop Test JIS C 0044 Customer’s specification. *Height:75 cm *Test Surface:Rigid surface of concrete or steel. *Times:6 surfaces for each units; 2 times for each side. No mechanical damage. Electrical specification shall satisfy the descriptions in electrical characteristics under the operational temperature range within -40 ~ 85°C. Vibration JIS C 0040 *Frequency:10Hz~55Hz~10Hz(1min) *Total amplitude:1.5mm *Test times:6hrs.(Two hrs each in three mutually perpendicular directions) No mechanical damage. Electrical specification shall satisfy the descriptions in electrical characteristics under the operational temperature range within -40 ~ 85°C. Adhesive Strength of Termination JIS C 0051- 7.4.3 *Pressurizing force: 5N(≦0603);10N(>0603) *Test time:10±1 sec No remarkable damage or removal of the termination. Approval sheet Page 7 of 9 ASC_RFANT5220110A2T_V03 May. 2013 Bending test JIS C 0051- 7.4.1 The middle part of substrate shall be pressurized by means of the pressurizing rod at a rate of about 1 mm/s per second until the deflection becomes 1mm/s and then pressure shall be maintained for 5±1 sec. Measurement to be made after keeping at room temperature for 24±2 hours No mechanical damage. Electrical specification shall satisfy the descriptions in electrical characteristics under the operational temperature range within -40 ~ 85°C. Temperature cycle JIS C 0025 1. 30±3 minutes at -40°C±3°C, 2. 10~15 minutes at room temperature, 3. 30±3 minutes at +85°C±3°C, 4. 10~15 minutes at room temperature, Total 100 continuous cycles Measurement to be made after keeping at room temperature for 24±2 hrs No mechanical damage. Electrical specification shall satisfy the descriptions in electrical characteristics under the operational temperature range within -40 ~ 85°C. High temperature JIS C 0021 *Temperature:85°C±2°C *Test du…

Text truncated - open the document above for the full version.

Test Report

AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2ACFI485WM Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25206 Page 1 of 127 FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of Digilife Technologies Co., Ltd. Car Camcorder f485s pro; f480u; f480u plus; f485s; f485s plus FCC ID: 2ACFI485WM Brand : HP Prepared for : Digilife Technologies Co., Ltd. 13F., No.7, Dexing W.Rd., Shilin Dist., Taipei City 11158, Taiwan Prepared By : Audix Technology (Shenzhen) Co., Ltd. No. 6, Kefeng Road, Science & Technology Park, Nanshan District , Shenzhen, Guangdong, China Tel: (0755) 26639496 Report Number : ACS-F25206 Date of Test : Aug.18~29, 2025 Date of Report : Sep.02, 2025 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2ACFI485WM Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25206 Page 2 of 127 TABLE OF CONTENTS Description Page 1. SUMMARY OF STANDARDS AND RESULTS ............................................................. 5 1.1. Description of Standards and Results ..................................................................................... 5 2. GENERAL INFORMATION ............................................................................................. 6 2.1. Description of Equipment Under Test .................................................................................... 6 2.2. Feature of Equipment Under Test ........................................................................................... 7 2.3. Tested Supporting System Details .......................................................................................... 8 2.4. Block diagram of connection between the EUT and simulators ............................................. 8 2.5. Test Equipments ...................................................................................................................... 9 2.6. Test Information .................................................................................................................... 10 2.7. Test Facility ........................................................................................................................... 11 2.8. Measurement Uncertainty (95% confidence levels, k=2) ..................................................... 11 3. POWER LINE CONDUCTED EMISSION TEST ........................................................ 12 3.1. Block Diagram of Test Setup ................................................................................................ 12 3.2. Power Line Conducted Emission Test Limits ....................................................................... 12 3.3. Configuration of EUT on Test .............................................................................................. 12 3.4. Operating Condition of EUT ................................................................................................. 13 3.5. Test Procedure ....................................................................................................................... 13 3.6. Power Line Conducted Emission Test Results ..................................................................... 13 4. RADIATED EMISSION TEST ........................................................................................ 16 4.1. Block Diagram of Test Setup ................................................................................................ 16 4.2. Radiated Emission Limits ..................................................................................................... 17 4.3. EUT Configuration on Test ................................................................................................... 17 4.4. Operating Condition of EUT ................................................................................................. 18 4.5. Test Procedure ....................................................................................................................... 18 4.6. Radiated Emission Test Results ............................................................................................ 18 5. CONDUCTED SPURIOUS EMISSIONS ....................................................................... 77 5.1. Limit ...................................................................................................................................... 77 5.2. Test Procedure ....................................................................................................................... 77 5.3. Test result .............................................................................................................................. 77 6. BAND EDGE COMPLIANCE TEST .............................................................................. 87 6.1. Limit ...................................................................................................................................... 87 6.2. Test Procedure ....................................................................................................................... 87 6.3. Test Results ........................................................................................................................... 87 7. 6dB & 99% Bandwidth Test ........................................................................................... 112 7.1. Limit .................................................................................................................................... 112 7.2. Test Procedure ..................................................................................................................... 112 7.3. Test Results ......................................................................................................................... 113 8. OUTPUT POWER TEST ............................................................................................... 119 8.1. Limit (FCC Part 15C 15.247 b(3)) ...................................................................................... 119 8.2. Test Procedure ............................…

Text truncated - open the document above for the full version.

Test Report

AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2ACFI485WM Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25206 Page 84 of 127 Test Mode: IEEE 802.11n HT20 Test CH1: 2412MHz --- --- AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2ACFI485WM Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25206 Page 85 of 127 Test CH6: 2437MHz AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2ACFI485WM Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25206 Page 86 of 127 Test CH11: 2462MHz --- AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2ACFI485WM Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25206 Page 87 of 127 6. BAND EDGE COMPLIANCE TEST 6.1. Limit All the lower and upper band-edges emissions appearing within 2310MHz to 2390MHz and 2483.5MHz to 2500MHz restricted frequency bands shall not exceed the limits shown in 15.209, all the other emissions outside operation frequency band 2400MHz to 2483.5MHz shall be at least 20dB below the fundamental emissions, or comply with 15.209 limits. 6.2. Test Procedure 1. The EUT is placed on a turntable, which is 1.5m above the ground plane and worked at highest radiated power. 2. The turntable was rotated for 360 degrees to determine the position of maximum emission level. 3. EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m to find out the highest emission. 4. Set the spectrum analyzer in the following setting in order to capture the lower and upper band-edges of the emission: (a) PEAK: RBW=1MHz; VBW=3MHz; Sweep=AUTO (b) AVERAGE: RBW=1MHz; VBW=10Hz; Sweep=AUTO 6.3. Test Results Pass (The testing data was attached in the next pages.) AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2ACFI485WM Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25206 Page 88 of 127 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2ACFI485WM Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25206 Page 89 of 127 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2ACFI485WM Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25206 Page 90 of 127 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2ACFI485WM Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25206 Page 91 of 127 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2ACFI485WM Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25206 Page 92 of 127 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2ACFI485WM Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25206 Page 93 of 127 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2ACFI485WM Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25206 Page 94 of 127 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2ACFI485WM Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25206 Page 95 of 127 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2ACFI485WM Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25206 Page 96 of 127 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2ACFI485WM Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25206 Page 97 of 127 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2ACFI485WM Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25206 Page 98 of 127 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2ACFI485WM Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25206 Page 99 of 127 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2ACFI485WM Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25206 Page 100 of 127 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2ACFI485WM Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25206 Page 101 of 127 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2ACFI485WM Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25206 Page 102 of 127 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2ACFI485WM Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25206 Page 103 of 127 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2ACFI485WM Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25206 Page 104 of 127 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2ACFI485WM Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25206 Page 105 of 127 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2ACFI485WM Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25206 Page 106 of 127 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2ACFI485WM Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25206 Page 107 of 127 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2ACFI485WM Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25206 Page 108 of 127 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2ACFI485WM Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25206 Page 109 of 127 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2ACFI485WM Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25206 Page 110 of 127 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2ACFI485WM Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25206 Page 111 of 127 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2ACFI485WM Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25206 Page 112 of 127 7. 6dB & 99% Bandwidth Test 7.1. Limit For direct sequence systems, the minimum 6dB bandwidth shall be at least 500kHz 7.2. Test Procedure Use the test method descried in ANSI C63.10 Section 11.8: The automatic bandwidth measurement capability of an instrument may be employed using the X dB bandwidth mode with X set to 6 dB, if the functionality described in 11.8.1 (i.e., RBW = 100 kHz, VBW ≥ 3 × RBW, and peak detector with maximum hold) is implemented by the instrumentation function. When using this capability, care shall be taken so that the bandwidth measurement is not influenced by any intermediate power nulls in the fundamental emission that might be ≥6 dB. Use the test method descried in ANSI C63.10 Section 6.9.2: The occupied bandwidth is the frequency bandwidth such that, below its lower and above its upper frequency limits, the mean powers are each equal to 0.5% of the total mean power of the given emission. The following procedure shall be used for measuring 99% power bandwidth: a) The instrument center frequency is set to the nom…

Text truncated - open the document above for the full version.

Test Report

AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2ACFI485WM Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25206 Page 126 of 127 Test Mode: IEEE 802.11n HT20 Test CH1: 2412MHz Test CH6: 2437MHz Test CH11: 2462MHz AUDIX Technology (Shenzhen) Co., Ltd. FCC ID: 2ACFI485WM Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25206 Page 127 of 127 10. ANTENNA REQUIREMENT 10.1. Standard Applicable For intentional device, according to FCC 47 CFR Section 15.203, an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. And according to FCC 47 CFR Section 15.247 (b), if transmitting antennas of directional gain greater than 6dBi are used, the power shall be reduced by the amount in dB that the directional gain of the antenna exceeds 6dBi. 10.2. Antenna Connected Construction The antennas used for this product are Chip ceramic antenna that no antenna other than that furnished by the responsible party shall be used with the device, the maximum peak gain of the transmit antenna is 2 dBi . AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:2ACFI485WM Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F25206 Page 128 of 1 11. DEVIATION TO TEST SPECIFICATIONS [NONE] THE END

Contact Information

Applicant

Joan Chao(Product Administrator)
[email protected]Fax: 886-2-27993099

Technical Contact

FCC US Agent, LLCTim Payne
[email protected]

3722 Illinois Avenue · Saint Charles, Illinois, 60174 · United States

Test Firm

AUDIX Technology (Shenzhen) Co., Ltd.Amelia Peng
[email protected]Fax: 86-75526632877

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz2.19 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is the maximum conducted output power. The antenna(s) used for this transmitter must be installed and operated so as to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. End-users must be informed of operating requirements for satisfying RF exposure compliance. This device supports 20 MHz bandwidth modes.