Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Page 1 of 23 EMC Technologies Pty Ltd ABN 82 057 105 549 Unit 3/87 Station Road Seven Hills NSW 2147 Australia Telephone +61 2 9624 2777 Facsimile +61 2 9838 4050 Email [email protected] www.emctech.com.au Melbourne 176 Harrick Road Keilor Park, Vic 3042 Tel: +61 3 9365 1000 Fax: +61 3 9331 7455 Sydney Unit 3/87 Station Road Seven Hills NSW 2147 Tel: +61 2 9624 2777 Fax: +61 2 9838 4050 Auckland (NZ) 47 MacKelvie Street Grey Lynn Auckland Tel: +64 9 360 0862 Fax: +64 9 360 0861 APPENDIX I OF TEST REPORT T130919_F USER MANUAL FCC ID: 2ACNLGPSP-SPI-0001 Manufacturer: GPSports Systems Pty Ltd Test Sample: HPU (High Performance Unit) Model Number: SPI HPU Serial Number: SPI HPU 1206 Date: 18 th August 2014 SPI HPU User Guide GPSportsSystems QuickstartGuide www.gpsports.com ©2014GPSportsSystems SAFETYINSTRUCTIONS TheSPI HPUisnotamedicalinstrument.Itisatrainingaid that hasbeen d esignedtoindicate yourspeed,distance,heartrate, impactsandaccelerations during sport .BeforeyoubeginusingtheSPI HPU visityourdoctorandconsultthemastoyourspecificexercise requirements.Peoplewhohaveheartorcirculatoryproblems andwearersofheartpacemakersshouldconsulttheirdoctor beforeusingtheSPI HPU .DonotweartheSPI HPUforactivities whereinjuriesarelikelytooccur.Consultingorchangingthe operatingmodeoftheSPI HPU whilemovingisunsafeandcould resultincollisionorotherinjury. INFORMATION The SPI HPU uses Global Positioning Satellite (GPS) technology to measure speed and d istance.The SPI HPUis not intended for use where precise measurement of speed and distanceare required. The GPS system is operated by the government of the United States of America, which issolely responsiblefor its accuracy and continued operation. The GPS system issubject to changes that may alter the accuracy of any GPS based equipment including the SPI HPU. ThisQuickstartGuideis an introductionto the operationof the SPI HPU athlete tracking unit .For more detailed informationconsultthe GPSports Team AMS Frequently Asked Questions (FAQ’s) manualsprovided within the installation software package. The SPI HPUcaptures and streams realtimespeed, heart rate, d istance,positionand accelerationdata on a second by second b asis.Maximum,minimumand average statistics can be reviewed for post sessionanalysis.The SPI HPUisideallysuitedfor performanceanalysisin a widevarietyof outdoor sportingactivities includingteam sports, running,rowing,cyclingand orienteering.In additionthe SPI HPUcollectsdata on “accelerations”in 3 axes @ 100 timesper second. Thisdata can be used to examinetechnique, impactsand body loadto ensure that athletes can measure performance,planimprovement and planappropriaterecovery regimes. HowdoestheSPI HPUSystemwork? The GPSports Systems® SPI HPUSports PerformanceIndicator integratesGlobalPositioningSatellite(GPS), Accelerometer,Heart rate and Wirelesstransmissiontechnologies.The SPI HPUuses informationtransmittedfromsatellitesto determine an athlete’s speed, position,altitudeand distancetraveled.The SPI HPUmust be operated outdoors with a clearviewof the sky to operate correctly. The integratedaccelerometermeasures movement and impacts.A heart rate strap worn around the chest transmitsheart rate informationwirelesslyto the SPI HPU. TheSPI HPUSystemhasbeendesignedspecificallyto • ManageandAnalysetheinformationcollectedduring Team sportingevents • Thesystemincludesstickerswhichmaybelabeledto identifyparticularSPI HPUUnits. • EachSPI HPUcanbeelectronicallynamedtosimplify identificationwhendownloadingdata. We recommend that you label each unitwith a name or number and match that name or number withthe electronicassignedname of theSPI HPU. Where possibleSPI HPUunitsshould be assignedto individual playersto minimisethe potentialfor confusion. www.gpsports.com 7of24 SPI HPUSystemandAccessories ‐ SPI HPU Unit ‐ SPI HPU Smart Docking Station ‐ Travel Case ‐ Heart Rate Monitor set ‐ 19v Power Pack ‐ USB connection ‐ GPS Vest, otherwise known as a GPS “Bro”/ Vest www.gpsports.com 8of24 SPI HPUAccessoriesContinued ‘TheBro’ GPS Vest Type equation here. PuttingaSPI HPUintheBro (Ensureunitistrackingbefore puttingitintotheBro) www.gpsports.com 8of24 Charging Beforethe SPI HPUwilloperate,theSPI HPUmustbecharged.SPI HPUunitsare fullychargedwhentheyleaveourfactory,howeverpartialdischarge oftheunitscanbeexpectedduringshipping. TheSPI HPUSmart DockingStation shouldbeconnectedtomainspower, u singthesuppliedPowerSupply when charging.AllSPI HPUunits sitting in the Smart Docking Station cradles willbecharged alternatively, 15 minutes on and 15 minutes off for 4 hours. Eg. Cradles: 1,3,5,7,9,11,13,15 will charge, then cradles 2,4,6,8,10,12,14. TochargetheSPI HPUensureitisseatedcomfortablyintoaDocking StationCradle. HPU units do not need to be on for charging, but the Smart Docking Station must be. Initialchargingwilltake approximately4hours. Asinglechargewillprovidemore than 7hours ofloggingtime per SPI HPU unit. www.gpsports.com 9of24 ButtonFunctions TurningtheSPI HPUOn Note:TheSPI HPUcanonlytrack GPSoutdoors. Turning theSPI HPUonindoorsmaycausethedevicetotakelongerto determineitslocation. ToturntheSPI HPUOn Hold down theblue theOn/Offbutton for 3 seconds. • Theindicatorlight will flash solid Red until turning Green. • Thegreenindicatorlight will remainasteady green whiletheSPI HPU attemptstoestablishitslo cation. WhentheSPI HPUestablishesitslocationthegreenindicatorlight willflash.Thismaytakeupto oneminute.TheSPI HPUwilllogactivityinexcessof7hours. If a HR is detected within range of the SPI HPU unit, I will flashes alternately with the Green light Red. The range between the unit and the HRM is approximately 50cm. www.gpsports.com 10of24 TurningtheSPI HPUOff ToturntheSPI HPUOff • Pressandholdtheblue On/Offbutton, • TheSPI HPUwillstore informationtoitsmemorywhich can be later downloaded to the Smart Docking Station. Heart Rate Information Theheartratesensormustbeworndirectlyontheskin.Adjustthe elasticstrap sothesensorispressedfirmlyagainstyourchest.To achievebetterskincontac…
Text truncated - open the document above for the full version.
AUTHORITY TO ACT AS AGENT TO THE FEDERAL COMMUNICATIONS COMMISSION I appoint EMC Technologies Pty Ltd, Christian Kai to act as agent in the preparation of this application for equipment authorization, on our behalf to the Federal Communications Commission. I certify that the exhibits submitted properly describe the device or system for which equipment authorization is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Commission's regulations, will have affixed to it a label identical to that submitted for approval with this application. Dated this 18 day of September 2013. By (Print Name) Adrian Faccioni Title Managing Director Telephone: 02 6162 2060
Federal Communications Commission Equipment Authorization Division Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21045 Subject: Request for Confidentiality for FCC Certification Application Pursuant to Rule 47 CFR, Chapter 1, Section 0.457(d)(1)(ii), GPSPorts, requests that prior to the equipment authorization grant for the (test sample) the entire application be classified and deemed confidential by the Federal Communications Commission (FCC) and as such be withheld from public inspection. As per 47 CFR, Chapter 1, Section 0.457, the exhibits tendered for the purpose of this grant, contain details of trade secrets and technical data that is not made available to competitors and the general public. This information is treated in a confidential manner by GPSPorts and guarded from disclosure to our competitors. The exhibits outlined below are not routinely made available to GPSPorts, with such access granted only to those specifically involved with this particular project. They contain information detailing the unique technology and circuitry of the product that would be of significant benefit to our competitors. All employees treat this technical data in a confidential manner. The manufacture of this product has taken place after an extensive research and development process that has seen the company invest a considerable amount of time and money. The time and effort taken has enabled the product to meet the specific demands of the competitive market for which it is intended and it would be therefore detrimental to allow competitors easy access to design and development details. Apart from a limited number of employees, the information has previously only been disclosed to the Test House responsible for conducting testing and authorized to act as our agent during the certification process. Pursuant to 47CFR Chapter 1, Section 0.459, GPSPorts requests post-grant confidentiality for the following items, ensuring that this material continue to be withheld from public inspection following the grant. Exhibit Type File Name Block Diagram Schematics Operational Description CONF_T130919_APPENDIX E _(SPI HPU)_BlkDia.pdf CONF_T130919_APPENDIX F (SPI HPU)_Schem.pdf CONF_T130919_APPENDIX J (SPI HPU)_Op Descr.pdf Sincerely Yours, Adrian Faccioni GPSports Systems Pty Ltd
Page 1 of 3 EMC Technologies Pty Ltd ABN 82 057 105 549 Unit 3/87 Station Road Seven Hills NSW 2147 Australia Telephone +61 2 9624 2777 Facsimile +61 2 9838 4050 Email [email protected] www.emctech.com.au Melbourne 176 Harrick Road Keilor Park, Vic 3042 Tel: +61 3 9365 1000 Fax: +61 3 9331 7455 Sydney Unit 3/87 Station Road Seven Hills NSW 2147 Tel: +61 2 9624 2777 Fax: +61 2 9838 4050 Auckland (NZ) 47 MacKelvie Street Grey Lynn Auckland Tel: +64 9 360 0862 Fax: +64 9 360 0861 APPENDIX C OF TEST REPORT T130919_F PHOTOGRAPHS OF TEST SAMPLE (EXTERIOR) FCC ID: 2ACNL-GPSP-SPI-0001 Manufacturer: GPSports Systems Pty Ltd Test Sample: HPU (High Performance Unit) Model Number: SPI HPU Serial Number: SPI HPU 1206 Date: 18th August 2014 FCC ID:2ACNL-GPSP-SPI-0001 Report No. T130919_F Appendix C Page 2 of 3 EMC Technologies Pty Ltd Unit 3, 87 Station Road Seven Hills NSW 2147 Australia Tel: +61 2 9624 2777 Fax: +61 2 9838 4050 APPENDIX C1 PHOTOGRAPHS TEST SAMPLE (EXTERIOR) FCC ID:2ACNL-GPSP-SPI-0001 Report No. T130919_F Appendix C Page 3 of 3 EMC Technologies Pty Ltd Unit 3, 87 Station Road Seven Hills NSW 2147 Australia Tel: +61 2 9624 2777 Fax: +61 2 9838 4050 APPENDIX C2 PHOTOGRAPHS TEST SAMPLE (EXTERIOR)
Page 1 of 2 EMC Technologies Pty Ltd ABN 82 057 105 549 Unit 3/87 Station Road Seven Hills NSW 2147 Australia Telephone +61 2 9624 2777 Facsimile +61 2 9838 4050 Email [email protected] www.emctech.com.au Melbourne 176 Harrick Road Keilor Park, Vic 3042 Tel: +61 3 9365 1000 Fax: +61 3 9331 7455 Sydney Unit 3/87 Station Road Seven Hills NSW 2147 Tel: +61 2 9624 2777 Fax: +61 2 9838 4050 Auckland (NZ) 47 MacKelvie Street Grey Lynn Auckland Tel: +64 9 360 0862 Fax: +64 9 360 0861 APPENDIX G OF TEST REPORT T130919_F LABELLING - LOCATION FCC ID: 2ACNLGPSP-SPI-0001 Manufacturer: GPSports Systems Pty Ltd Test Sample: HPU (High Performance Unit) Model Number: SPI HPU Serial Number: SPI HPU 1206 Date: 18th August 2014
Page 1 of 4 EMC Technologies Pty Ltd ABN 82 057 105 549 Unit 3/87 Station Road Seven Hills NSW 2147 Australia Telephone +61 2 9624 2777 Facsimile +61 2 9838 4050 Email [email protected] www.emctech.com.au Melbourne 176 Harrick Road Keilor Park, Vic 3042 Tel: +61 3 9365 1000 Fax: +61 3 9331 7455 Sydney Unit 3/87 Station Road Seven Hills NSW 2147 Tel: +61 2 9624 2777 Fax: +61 2 9838 4050 Auckland (NZ) 47 MacKelvie Street Grey Lynn Auckland Tel: +64 9 360 0862 Fax: +64 9 360 0861 APPENDIX D OF TEST REPORT T130919_F PHOTOGRAPHS OF TEST SAMPLE (INTERIOR) FCC ID: 2ACNLGPSP-SPI-0001 Manufacturer: GPSports Systems Pty Ltd Test Sample: HPU (High Performance Unit) Model Number: SPI HPU Serial Number: SPI HPU 1206 Date: 18 th August 2014 FCC ID: 2ACNLGPSP-SPI-0001 Report No. T130919_F Appendix D Page 2 of 4 EMC Technologies Pty Ltd Unit 3, 87 Station Road Seven Hills NSW 2147 Australia Tel: +61 2 9624 2777 Fax: +61 2 9838 4050 APPENDIX D1 PHOTOGRAPHS TEST SAMPLE (INTERIOR) FCC ID: 2ACNLGPSP-SPI-0001 Report No. T130919_F Appendix D Page 3 of 4 EMC Technologies Pty Ltd Unit 3, 87 Station Road Seven Hills NSW 2147 Australia Tel: +61 2 9624 2777 Fax: +61 2 9838 4050 APPENDIX D2 PHOTOGRAPHS TEST SAMPLE (INTERIOR) FCC ID: 2ACNLGPSP-SPI-0001 Report No. T130919_F Appendix D Page 4 of 4 EMC Technologies Pty Ltd Unit 3, 87 Station Road Seven Hills NSW 2147 Australia Tel: +61 2 9624 2777 Fax: +61 2 9838 4050 APPENDIX D3 PHOTOGRAPHS TEST SAMPLE (INTERIOR)
Page 1 of 17 EMC Technologies Pty Ltd ABN 82 057 105 549 Unit 3/87 Station Road Seven Hills NSW 2147 Australia Telephone +61 2 9624 2777 Facsimile +61 2 9838 4050 Email [email protected] www.emctech.com.au Melbourne 176 Harrick Road Keilor Park, Vic 3042 Tel: +61 3 9365 1000 Fax: +61 3 9331 7455 Sydney Unit 3/87 Station Road Seven Hills NSW 2147 Tel: +61 2 9624 2777 Fax: +61 2 9838 4050 Auckland (NZ) 47 MacKelvie Street Grey Lynn Auckland Tel: +64 9 360 0862 Fax: +64 9 360 0861 EMI TEST REPORT for CERTIFICATION of FCC PART 15.249 & FCC PART 15.207 TRANSMITTER FCC ID: 2ACNLGPSP-SPI-0001 Manufacturer: GPSports Systems Pty Ltd Test Sample: HPU (High Performance Unit) Model Number: SPI HPU Serial Number: SPI HPU 1206 Date: 18 th August 2014 EMC Technologies Pty Ltd reports apply only to the specific samples tested under stated test conditions. All samples tested were in good operating condition throughout the entire test program. It is the manufacturer’s responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. EMC Technologies Pty Ltd shall have no liability for any deductions, interferences or generalisations drawn by the client or others from EMC Technologies Pty Ltd issued reports. This report shall not be used to claim, constitute or imply product endorsement by EMC Technologies Pty Ltd. Accredited for compliance with ISO/IEC 17025. The results of tests, calibration and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing and calibration reports. This document shall not be reproduced except in full. FCC ID: 2ACNLGPSP-SPI-0001 EMC Technologies Pty Ltd Report No. T130919 Page 2 of 17 EMC Technologies Pty Ltd Unit 3, 87 Station Road Seven Hills NSW 2147 Australia Tel: +61 2 9624 2777 Fax: +61 2 9838 4050 EMI TEST REPORT FOR CERTIFICATION FOR CERTIFICATION OF FCC Part 15.249 & FCC PART 15.207 TRANSMITTER FCC ID: 2ACNL-GPSP-SPI-0001 EMC Technologies Report No. T130919 Date: 18 th August 2014 CONTENTS 1. SUMMARY OF TEST RESULTS 2. GENERAL INFORMATION 3. CONDUCTED EMI RESULTS 4. RADIATED EMI RESULTS 5. UNCERTAINTIES 6. FREQUENCY TOLERANCE 7. CONCLUSION APPENDIX A. MEASUREMENT INSTRUMENTATION DETAILS APPENDIX B. PHOTOGRAPHS TEST SETUP APPENDIX C. PHOTOGRAPHS TEST SAMPLE (EXTERIOR) APPENDIX D. PHOTOGRAPHS TEST SAMPLE (INTERIOR) APPENDIX E. BLOCK DIAGRAM APPENDIX F. TEST SAMPLE SCHEMATICS APPENDIX G. LABELLING – LOCATION APPENDIX H. GRAPHS OF EMI MEASUREMENT APPENDIX I. USER MANUAL APPENDIX J. OPERATIONAL DESCRIPTION FCC ID: 2ACNLGPSP-SPI-0001 EMC Technologies Pty Ltd Report No. T130919 Page 3 of 17 EMC Technologies Pty Ltd Unit 3, 87 Station Road Seven Hills NSW 2147 Australia Tel: +61 2 9624 2777 Fax: +61 2 9838 4050 EMI TEST REPORT FOR CERTIFICATION OF FCC PART 15.249 & FCC PART 15.207 TRANSMITTER Report Number: T130919 Test Sample Name: HPU (High Performance Unit) Model Number: SPI-HPU Serial Number: SPI-HPU 1206 FCC ID: 2ACNLGPSP-SPI-0002 Manufacturer: GPSports Systems Pty Ltd Tested For: GPSports Systems Pty Ltd Address: Level 2, 18 Barrier Street Fyschwick, ACT, Phone Number: (02) 6162 2060 Fax Number: (02) 6162 2066 Responsible Party: Michael Reznik Test Standards: FCC Part 15.249 Intentional Radiators FCC Part 15.207 Conducted Limits ANSI C63.4:2009 Test Dates: 12 th September 2013 to 18 th October 2013 Testing Officer: Kumar Thambiaiah Attestation: I hereby certify that the device(s) described herein were tested as described in this report and that the data included is that which was obtained during such testing. Authorised Signature: Christian Kai Facility Manager EMC Technologies Pty Ltd Issued by EMC Technologies Pty Ltd, Unit 3/87 Station Road, Seven Hills, NSW, 2147, Australia. Phone: +61 2 9624 2777 Fax: +61 2 9838 4050 FCC ID: 2ACNLGPSP-SPI-0001 EMC Technologies Pty Ltd Report No. T130919 Page 4 of 17 EMC Technologies Pty Ltd Unit 3, 87 Station Road Seven Hills NSW 2147 Australia Tel: +61 2 9624 2777 Fax: +61 2 9838 4050 EMI TEST REPORT FOR CERTIFICATION of FCC PART 15.249 & FCC PART 15.207 TRANSMITTER on the HPU (High Performance Unit) 1.0 SUMMARY of RESULTS This report details the results of EMI tests and measurements performed on the HPU (High Performance Unit), Model: SPI-HPU, in accordance with the Federal Communications Commission (FCC) regulations as detailed in Title 47 CFR, Part 15 Rules for intentional radiators. All results are detailed in this report. Part 15.31e Amplitude stability with supply variation: Not applicable Part 15.207 Conducted Emissions: Not applicable Part 15.249 a &e Carrier Signal Field Strength 2400-2483.5MHz: Complied Part 15.249 d (15.209) Field Strength Outside 2400 – 2483.5MHz: Complied Part 15.249 e Frequency Tolerance: Complied 1.1 EUT – Voltage Power Conditions Testing was performed with a fully charged battery FCC ID: 2ACNLGPSP-SPI-0001 EMC Technologies Pty Ltd Report No. T130919 Page 5 of 17 EMC Technologies Pty Ltd Unit 3, 87 Station Road Seven Hills NSW 2147 Australia Tel: +61 2 9624 2777 Fax: +61 2 9838 4050 2.0 GENERAL INFORMATION 2.1 General Description of Test Sample Manufacturer : GPSports Systems Pty Ltd Test Sample : HPU (High Performance Unit) Model Number : SPI HPU Serial Number : SPI HPU 1206 Part Number : HPU-Rv1 FCC ID : 2ACNL-GPSP-SPI-0001 Equipment Type : Intentional Radiator 2.2 Test Sample Description The HPU (High Performance Unit) is worn by athletes during sport to track their movement, loading and heart rate response. Works in conjunction with GPsports receiver and PC with GPSports Team AMS application. 2.3 Technical Specifications and System Overview Clock Circuit Speed : 16MHz Microprocessor : AT86RF233, ATxmega256A3U Refer to Appendix I for User Manual. 2.4 EUT Configurations The EUT is to be tested as a table top unit along the guidelines contained in the relevant standards for…
Text truncated - open the document above for the full version.
Page 1 of 2 EMC Technologies Pty Ltd ABN 82 057 105 549 Unit 3/87 Station Road Seven Hills NSW 2147 Australia Telephone +61 2 9624 2777 Facsimile +61 2 9838 4050 Email [email protected] www.emctech.com.au Melbourne 176 Harrick Road Keilor Park, Vic 3042 Tel: +61 3 9365 1000 Fax: +61 3 9331 7455 Sydney Unit 3/87 Station Road Seven Hills NSW 2147 Tel: +61 2 9624 2777 Fax: +61 2 9838 4050 Auckland (NZ) 47 MacKelvie Street Grey Lynn Auckland Tel: +64 9 360 0862 Fax: +64 9 360 0861 APPENDIX A OF TEST REPORT T130919_F MEASUREMENT INSTRUMENTATION DETAILS FCC ID: 2ACNLGPSP-SPI-0001 Manufacturer: GPSports Systems Pty Ltd Test Sample: HPU (High Performance Unit) Model Number: SPI HPU Serial Number: SPI HPU 1206 Date: 18 th August 2014 FCC ID: 2ACNLGPSP-SPI-0001 Report No. T130919_F Appendix A Page 2 of 2 EMC Technologies Pty Ltd Unit 3, 87 Station Road Seven Hills NSW 2147 Australia Tel: +61 2 9624 2777 Fax: +61 2 9838 4050 APPENDIX A MEASUREMENT INSTRUMENTATION CALIBRATION DETAILS Equipment Type Make/Model Serial Number Last Cal. DD/MM/YY Due Date DD/MM/YY EMI Receiver ESCI Rohde Schwarz, 9kHz – 3GHz, S/N: 100012 07/03/12 07/03/14 *4 EMI Receiver ESCI Rohde Schwarz, 20Hz – 40GHz, S/N: 100183 24/01/13 24/01/14 *4 LISN Single Phase: EMCO 3825/2 SN 94112274 02/02/12 02/02/14 *3 Transient Limiter HP11947A, S/N: 3107A00857 10/07/13 10/07/14 *3 Antenna EMCO 6502 Active Loop S/N 9108-2660, 9 kHz – 30 MHz 29/11/14 29/11/15 *1 Antenna EMCO 3110B Biconical S/N 9603-2350, 20-300 MHz 12/01/12 12/01/14 *3 Antenna EMCO 3146 Log Periodic S/N 9603-4415, 300-1000MHz 15/02/13 15/02/14 *3 Antenna EMCO 3115 Horn Antenna S/N: 3823, 1-18GHz 16/01/12 16/01/15 *3 Preamplifier HP 8449B S/N: 3008A01113, 1GHz to26.5GHz 21/03/13 21/03/14 *3 Note *1 : National Measurements Laboratory calibration Note *2 : NATA Calibration by VMS Note *3 : In-house calibration. Traceable to Australian National Standards. Note *4: NATA Calibration by Rohde & Schwarz TEST SITES Equipment Type Make/Model Serial Number Last Cal. DD/MM/YY Due Date DD/MM/YY Shielded Room/ Test Laboratory 7.23m × 4.83m × 2.45m N/A N/A Indoor Open Area Test Site (iOATS) RFI Industries S800 Serial Number: 876, 3 metres iOATS situated at Seven Hills, NSW 22/02/13 22/02/14 *3
Page 1 of 20 EMC Technologies Pty Ltd ABN 82 057 105 549 Unit 3/87 Station Road Seven Hills NSW 2147 Australia Telephone +61 2 9624 2777 Facsimile +61 2 9838 4050 Email [email protected] www.emctech.com.au Melbourne 176 Harrick Road Keilor Park, Vic 3042 Tel: +61 3 9365 1000 Fax: +61 3 9331 7455 Sydney Unit 3/87 Station Road Seven Hills NSW 2147 Tel: +61 2 9624 2777 Fax: +61 2 9838 4050 Auckland (NZ) 47 MacKelvie Street Grey Lynn Auckland Tel: +64 9 360 0862 Fax: +64 9 360 0861 APPENDIX H OF TEST REPORT T130919_F GRAPHS OF EMI MEASUREMENT FCC ID: 2ACNLGPSP-SPI-001 Manufacturer: GPSports Systems Pty Ltd Test Sample: HPU (High Performance Unit) Model Number: SPI HPU Serial Number: SPI HPU 1206 Date: 18th August 2014 FCC ID:2ACNLGPSP-SPI-0001 Report No. T130919 _F Appendix H Page 2 of 20 EMC Technologies Pty Ltd Unit 3, 87 Station Road Seven Hills NSW 2147 Australia Tel: +61 2 9624 2777 Fax: +61 2 9838 4050 APPENDIX H GRAPHS OF EMI MEASUREMENT RADIATED EMI Graph 1: Loop Antenna, 0 Degrees 9 kHz to 30 MHz Graph 2: Loop Antenna, 90 Degrees 9 kHz to 30 MHz Graph 3: Vertical Antenna Polarisation 29 to 1000 MHz Graph 4: Horizontal Antenna Polarisation 29 to 1000 MHz Graph 5: Low Channel 2405 MHz Peak 2400 to 2410 MHz Graph 6: Mid Channel 2440 MHz Peak 2435 to 2445 MHz Graph 7: High Channel 2480 MHz Peak 2477 to 2483 MHz Graph 8: Low Band edge Average 2390 to 2410 MHz Graph 9: High Band edge Average 2475 to 2495 MHz Graph 10: Vertical Polarisation Average 1000 to 3950 MHz Graph 11: Horizontal Polarisation Average 1000 to 3950 MHz Graph 12: Vertical Polarisation Average 1000 to 3950 MHz Graph 13: Horizontal Polarisation Average 1000 to 3950 MHz Graph 14: Vertical Polarisation Average 3950 to 12400 MHz Graph 15: Horizontal Polarisation Average 3950 to 12400 MHz Graph 16: Horizontal Polarisation, Peak 2600 to 3950 MHz Graph 17: Vertical Polarisation, Peak 4500 to 5850 MHz Graph 18: Horizontal Polarisation, Peak 4500 to 5850 MHz EMC Technologies Pty. Ltd. - Global Product CertificationFCC Class B Job No:T130919 Test Date: 18-10-2013 GRAPH No. 1 p:\PCF\T130919T_1.PCF EMC Technologies (Sydney) 3/87 Station Rd, Seven Hills, NSW, 2147, NSW, Australia Phone +(612) 9624 2777 Fax+(612) 9838 4050 GP Sports Systems Pty Ltd HPU (High Performance Unit) Model: SPI HPU Serial Number: SPI HPU 1206 Tested with SPI Pro X (Spx01955) and SPI HPU 1025 Transmitte r Radiated Emissions (dBuV/m) T130919T # = Ambient Limits: Legend: Source: _ FCC-B3 FCC CLASS B RAD 3M LIMITS __ 0deg Emissions 1 , 2 , 10 , 4 Ver 5.5 Build 160Radiated setup for Rm 3 with Loop Antenna t:A0080414E c1:C0280714 c2:NONE p:NONE a:NONESite ID: Syd Room#3,3/87 Station Rd, Seven Hills, NSW Test Officer:Kumar Thambiaiah Peaks:No Freq Peak QP Val FCC-B3 dL1 (MHz) (dBuV/m) (dBuV/m) (dB) 1 4.509 32.6 26.7 69.5 -42.8 Frequency (MHz) .1 1 10 .009 30 10 20 30 40 50 60 70 80 90 100 110 120 130 140 v ^ 1 ~ EMC Technologies Pty. Ltd. - Global Product CertificationFCC Class B Job No:T130919 Test Date: 18-10-2013 GRAPH No. 2 p:\PCF\T130919T_2.PCF EMC Technologies (Sydney) 3/87 Station Rd, Seven Hills, NSW, 2147, NSW, Australia Phone +(612) 9624 2777 Fax+(612) 9838 4050 GP Sports Systems Pty Ltd HPU (High Performance Unit) Model: SPI HPU Serial Number: SPI HPU 1206 Tested with SPI Pro X (Spx01955) and SPI HPU 1025 Transmitte r Radiated Emissions (dBuV/m) T130919T # = Ambient Limits: Legend: Source: _ FCC-B3 FCC CLASS B RAD 3M LIMITS __ 90deg Emissions 5 , 6 , 9 , 8 Ver 5.5 Build 160Radiated setup for Rm 3 with Loop Antenna t:A0080414E c1:C0280714 c2:NONE p:NONE a:NONESite ID: Syd Room#3,3/87 Station Rd, Seven Hills, NSW Test Officer:Kumar Thambiaiah Peaks:No Freq Peak QP Val FCC-B3 dL1 (MHz) (dBuV/m) (dBuV/m) (dB) 1 4.475 36.9 30.9 69.5 -38.6 Frequency (MHz) .1 1 10 .009 30 10 20 30 40 50 60 70 80 90 100 110 120 130 140 v ^ 1 ~ EMC Technologies Pty. Ltd. - Global Product CertificationFCC Class B Job No:T130919 Test Date: 18-10-2013 GRAPH No. 3 p:\PCF\T130919T_3.PCF EMC Technologies (Sydney) 3/87 Station Rd, Seven Hills, NSW, 2147, NSW, Australia Phone +(612) 9624 2777 Fax+(612) 9838 4050 GP Sports Systems Pty Ltd HPU (High Performance Unit) Model: SPI HPU Serial Number: SPI HPU 1206 Tested with SPI Pro X (Spx01955) and SPI HPU 1025 Transmitte r Radiated Emissions (dBuV/m) T130919T # = Ambient Limits: Legend: Source: _ FCC-B3 FCC CLASS B RAD 3M LIMITS __ Vertical Emissions 11 , 12 , 13 , 17 , 18 Ver 5.5 Build 160Room 3 with HP Bicon t:A2230214 c1:C0280714 c2:NONE p:NONE a:NONESite ID: Syd Room#3,3/87 Station Rd, Seven Hills, NSW Test Officer:Kumar Thambiaiah Peaks:No Freq Peak QP Val FCC-B3 dL1 (MHz) (dBuV/m) (dBuV/m) (dB) 1 705.09 30.5 25.2 46.0 -20.8 2 206.08 21.0 15.8 43.5 -27.7 Frequency (MHz) 100 29 1000 0 10 20 30 40 50 60 70 80 v ^ 1 ~ v ^ 2 ~ EMC Technologies Pty. Ltd. - Global Product CertificationFCC Class B Job No:T130919 Test Date: 18-10-2013 GRAPH No. 4 p:\PCF\T130919T_4.PCF EMC Technologies (Sydney) 3/87 Station Rd, Seven Hills, NSW, 2147, NSW, Australia Phone +(612) 9624 2777 Fax+(612) 9838 4050 GP Sports Systems Pty Ltd HPU (High Performance Unit) Model: SPI HPU Serial Number: SPI HPU 1206 Tested with SPI Pro X (Spx01955) and SPI HPU 1025 Transmitte r Radiated Emissions (dBuV/m) T130919T # = Ambient Limits: Legend: Source: _ FCC-B3 FCC CLASS B RAD 3M LIMITS __ Horizontal Emissions 14 , 15 , 16 , 19 , 20 Ver 5.5 Build 160Room 3 with HP Bicon t:A2230214 c1:C0280714 c2:NONE p:NONE a:NONESite ID: Syd Room#3,3/87 Station Rd, Seven Hills, NSW Test Officer:Kumar Thambiaiah Peaks:No Freq Peak QP Val FCC-B3 dL1 (MHz) (dBuV/m) (dBuV/m) (dB) 1 703.29 30.3 25.3 46.0 -20.7 2 79.83 14.0 7.7 40.0 -32.3 Frequency (MHz) 100 29 1000 0 10 20 30 40 50 60 70 80 v ^ 1 ~ v ^ 2 ~ EMC Technologies Pty. Ltd. - Global Product CertificationFCC Class B Job No:T130919 Test Date: 03-10-2013 GRAPH No. 5 p:\PCF\T130919G_1.PCF EMC Technologies (Sydney) 3/87 Station Rd, Seven Hills, NSW, 2147, NSW, Australia Phone +(612) 9624 2777 Fax+(612) 9838 4050 GP Sports Systems Pty Ltd HPU (H…
Text truncated - open the document above for the full version.
Page 1 of 3 EMC Technologies Pty Ltd ABN 82 057 105 549 Unit 3/87 Station Road Seven Hills NSW 2147 Australia Telephone +61 2 9624 2777 Facsimile +61 2 9838 4050 Email [email protected] www.emctech.com.au Melbourne 176 Harrick Road Keilor Park, Vic 3042 Tel: +61 3 9365 1000 Fax: +61 3 9331 7455 Sydney Unit 3/87 Station Road Seven Hills NSW 2147 Tel: +61 2 9624 2777 Fax: +61 2 9838 4050 Auckland (NZ) 47 MacKelvie Street Grey Lynn Auckland Tel: +64 9 360 0862 Fax: +64 9 360 0861 APPENDIX B OF TEST REPORT T130919_F PHOTOGRAPHS OF TEST SET UP FCC ID: 2ACNLGPSP-SPI-0001 Manufacturer: GPSports Systems Pty Ltd Test Sample: HPU (High Performance Unit) Model Number: SPI HPU Serial Number: SPI HPU 1206 Date: 18th August 2014 FCC ID: 2ACNLGPSP-SPI-0001 Report No. T130919_F Appendix B Page 2 of 3 EMC Technologies Pty Ltd Unit 3, 87 Station Road Seven Hills NSW 2147 Australia Tel: +61 2 9624 2777 Fax: +61 2 9838 4050 APPENDIX B1 TEST SETUP PHOTOS Radiated Emissions FCC ID: 2ACNLGPSP-SPI-0001 Report No. T130919_F Appendix B Page 3 of 3 EMC Technologies Pty Ltd Unit 3, 87 Station Road Seven Hills NSW 2147 Australia Tel: +61 2 9624 2777 Fax: +61 2 9838 4050 APPENDIX B2 TEST SETUP PHOTOS Radiated Emissions
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.404 MHz - 2.479 MHz | - |