Product Specification 1. Current comsumption: 1.35mA av. 2. Amount of constant test time: 220 hours. 3. Work Environment: temperature: between 5°C and 40 °C. Humidity: <70% 4. Moisture content range: 20%-60% 5. Error: <1% 6. Size: 27mm*22mm*63mm 7. Working together with Application: MeiJia Product Function As a small-size and stylish-design one, our product is convenient to use and carry. Basing on the technology of detecting Biological impedance, accompanied with data mining technology in our App “MeiJia”, our product manages to test out moisture content of human’s skin and then give out deep analysis. The whole test process takes about 5 seconds, whose result then will be sent to Smart Phone through Bluetooth Low Energy and shown in our App. Besides, according to the real-time value of your skin moisture content and your personal body message, we will provide the accurate and exclusive skin care advice. Instructions 1 st .take away the cap. 2 nd .Press the button on the bottom of product. Then the blinking green led means the device is waiting for connection. 3 rd .Run the MeiJia APP on your mobile phone, led will turn constant green if connection is successful. 4 th .Chose one position of your body in App, then put the sonde of product on the position correctly(the sonde must be pressed wholly), the test will begin automatically. 5 th .While testing, led will turn constant blue, do not move away the sonde until test finishes when the led will turn back constant green. 6 th .Redo step 4&5 if you want to retest. 7 th .Press the button on the bottom of product again to turn it off. 8 th .Wipe the sonde with alcohol drenched cloth and replace the cap. 9 th .For an accurate result, please wipe the test position cleanly, in case of the sweat and other materials affect the result. Common questions 1 st .If led keeps blinking green, it means product and app do not connect. 2 nd .If led keeps constant green, it means product and app connect successfully. Test can begin now. 3 rd .If led keeps constant blue, please do not move away the sonde until the test finishes when led will turn back constant green. 4 th .If led keeps constant red, it means wrong operations have been done. Wait until led turn back constant green and test again. guarantee 1 st .Keep the sonde of product clean. 2 nd .Plsase do not dismounting the product. 3 rd .Please prevent product from high-temperature and high-humidity environment. 4 th .Please put back product into box after use. 5 th .Be aware of water and liquid entering into product. Wiping product with acid and alkaline liquid is forbidden. 6 th .If the battery’s electric quantity is insufficient, we will give you a new one for free. Using steps: 1 st .Open the Bluetooth on your phone, run our App “MeiJia”. 2 nd .Press the button on the bottom of product, the blinking green led will turn constant green if BLE connection is successful. 3 rd .Put the sonde of product on test position, press slightly then test will begin while led will keep constant blue. *If led turns constant red means wrong operations have been done. 4 th .After analysis within 5 seconds, the result will be shown in our App “MeiJia”. Moisture content at Spring&Autumn(normal value) Orbital(35%~50%) Forehead(30%~43%) Cheek(32%~47%) *At summer the moisture content varies about 3% while at winter varies about 5% Supported phone’s system and type Iphone4s,Iphone5,Iphone5s,Iphone5c The ones which support Bluetooth 4.0 and are assembled with IOS 5/6/7: Iphone4s,Iphone5,Iphone5s,Iphone5c Samsung Galaxy S3/S4、Samsung Note 3 and so on; The most ones which support Bluetooth 4.0 and are assembled with System of Android 4.3 or upgrade from System below Android 4.3 Notes: *Before using, please read carefully and follow the operation instruction. *For an accurate result, please wipe the test position cleanly, in case of the cosmetic、oil and other materials affect the result. *Although the design of product has controlled the pressing strength in a specific range, its value will still affect the result a little bit. So please mind the strength while pressing, better at the level when transparent shell touches the skin. *Keep snode in touch with skin without shaking in 5 seconds in order to decrease error probability and increase reliability. *Keep snode of product clean. *Metal allergies should use with caution. *Do not use while the skin has wound or inflammation. *This product is not waterproof. Please do not soak it in water. *If the instruction led does not work, please contact our company and do not dismounting the product. Guarantee Shenzhen Mlizhi Science and Technology Limited Company obeies strictly <Product Quality Law of The People's Republic of China> and <Law of the PRC on the Protection of the Rights and Interests of Consumers> ,also gives out Three Guarantees For Products to customers. If our Terms of Service is not compatible with Three Guarantees For Products, refer the rules and content of latter one. For those of regions that execute special directory of Three Guarantees of Products, Shenzhen Mlizhi Science and Technology Llimited Company will obey local relative rules. Please note: Any situation mentioned below does not belong to the range of Three Guarantees For Products. 1 st .Product that out of date. 2 nd .Damage caused by using/maintaining/keeping product that have not followed the product operation instruction. 3 rd .Danage caused by dismount by the ones who do not undertake the Three Guarantees of Products. 4 th .Without the Three Guarantees of Products certificate or effective invoice(except the ones that can prove the product is within the date). 5 th .Unauthorized alter of Three Guarantees of Products certificate. 6 th .The type or number of product in Three Guarantees of Products is not compatible with product in kind. 7 th .Without manufacturer’s name、manufacturer’s address、manufacture date or manufacturer’s certificate. 8 th .Cause by unpreventable strength. Contact us directly if y…
Text truncated - open the document above for the full version.
External Photos of EUT Sample
FCC ID:2ACXE-MLZ001
Internal Photos of EUT Sample
RF Exposure evaluation According to KDB 447498 D01 General RF Exposure Guidance v05 The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison eirp = pt x gt = (EXd) 2 /30 where: pt = transmitter output power in watts, gt = numeric gain of the transmitting antenna (unitless), E = electric field strength in V/m, --- 10 ((dBuV/m)/20) /10 6 d = measurement distance in meters (m)---3m So pt = (EXd) 2 /30 x gt Field strength = 98.24 dBuV/m @3m Ant gain 0dBi; so Ant numeric gain=1 So pt={ [10 ( 98.24 /20) /10 6 x3] 2 /30x1 }x1000 mW = 2 mW So ( 2 mW/5mm)x √2.480 GHz = 0.632 <3 Then SAR evaluation is not required
Shenzhen EBO T echnology Co., Ltd . 1-4F, Huafeng Science Park, Xin’an Sixth Road, 82 th District, Bao’an, Shenzhen, China. Telephone: +86-755-29451282, Fax: +86-755-22639141 Report No.: EBO1408001-E098 Page 1 of 25 Authorized Signature: Kevin Yu Laboratory Manager This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product and does not permit the use of the EBO product certification mark. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. Any mention of EBO International Electrical Approvals or testing done by EBO International Electrical Approvals in connection with, distribution or use of the product described in this report must be approved by EBO International Electrical Approvals in writing. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.” FCC REPORT Applicant: SHENZHEN MLIZHI TECHNOLOGY CO., LTD. Address of Applicant: Sangtai Building, University-town Business Park, Xili, Nanshan, Shenzhen Equipment Under Test (EUT) Product Name: SKIN MOISTURE DETECTOR Brand Name: Mlizhi Model No.: the first version FCC ID: 2ACXE-MLZ001 Applicable standards: FCC CFR Title 47 Part 15 Subpart C Section 15.249:2013 Date of sample receipt: August 1, 2014 Date of Test: August 1, 2014 To August 12, 2014 Date of report issued: August 12, 2014 Test Result : PASS * * In the configuration tested, the EUT complied with the standards specified above Shenzhen EBO Technology Co., Ltd . Report No.: EBO1408001-E098 Page 2 of 25 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.ebotek.cn 2 Version Version No. Date Description 00 August 12, 2014 Original Prepared By: Date: August 12, 2014 Project Engineer Check By: Date: August 12, 2014 Reviewer and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.ebotek.cn . Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.” Shenzhen EBO Technology Co., Ltd . Report No.: EBO1408001-E098 Page 3 of 25 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.ebotek.cn and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.ebotek.cn . Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.” 3 Contents Page 1 COVER PAGE............................................................................................................................................ 1 2 VERSION..................................................................................................................................................2 3 CONTENTS..............................................................................................................................................3 4 TEST SUMMARY.....................................................................................................................................4 5 GENERAL INFORMATION...................................................................................................................... 5 5.1 CLIENT INFORMATION......................................................................................................................... 5 5.2 GENERAL DESCRIPTION OF EUT......................................................................................................... 5 5.3 TEST MODE.............................................…
Text truncated - open the document above for the full version.
TEST SETUP PHOTOGRAPHS 1. Radiated Emission Test Setup
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | - |