Wireless Charger 本产品 线 是一款智 线 电 ,设计简洁大 , 任何Qi标 的手机 设备兼 , 电设备 线插 ,超 附 电畅玩 戏, 便快捷。 为您提供唔舒服的生活体验, 受自由、 全 线 电体验。 产品介绍 产品 观 线 电 域 尺寸:80*60mm 配件清单 产品规格 线 电 1 说明书 1 名 颜 色 输 输 电 用设备 线 电 白色 12V--1.5A/9V--2A/5V--3A 5W/7.5W/10W/15W 5mm < 使用说明 电源输 。 USB-C Magnetic Suction Wireless Charging 线 电 使用说明书 材 质 ABS+PC The wireless charger of this product is a smart magnetic wireless charger with a simple and elegant design, which is compatible with any Qi standard.Compatible with standard mobile phones and devices, wireless plugging and unplugging of charging devices, super adsorption and charging, easy and fast to play games. Provide you with an uncomfortable life experience and enjoy a free and safe wireless charging experience. Product description Appearance Wireless charging area Parts List Product specifications Magnetic wireless charger 1 Manual 1 Parameter Name Colour Input Output Charging distance Applicable equipment Magnetic Suction Wireless Charging White 12V--1.5A/9V--2A/5V--3A 5W/7.5W/10W/15W 5mm < Instructions USB-C Material qualityABS+PC Magnetic &wireless Power input 1. For devices with wireless charging function. 2. Compared with the old model, the charging speed is 20% faster. 3. There is safety protection technology during charging. Magnetic &wireless Connect the USB charging cable to the power adapter This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. FCC Radiation Exposure Statement The equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. During the operation of device a distance of 15 cm surrounding the device and 20 cm above the top surface of the device must be respected. FCC ID:2ADDW-WIM10
Sincerely, Name/Title: Ou Liang/Manager Company: Shenzhen Topband Co., Ltd Address: Topband Industrial Park, Liyuan Industrial Zone, Tangtou, Shiyan, Bao’an, Shenzhen, 518108, Guangdong, China Phone: 0755-27651888 Fax: 0755-29833210 E-Mail: [email protected]
Page1of3FCCID:2ADDW-WIM10 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity EXTERIORPHOTOGRAPHS Fig.1 Fig.2 Page2of3FCCID:2ADDW-WIM10 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of3FCCID:2ADDW-WIM10 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6
Page1of1FCCID:2ADDW-WIM10 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LABELANDLOCATION (Size:L3.5cmx3.0cm) LabelLocation MagneticSuctionWirelessCharging Model:WIM10 FCCID:2ADDW-WIM10
Page1of3FCCID:2ADDW-WIM10 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity INTERIORPHOTOGRAPHS Fig.1 Fig.2 Page2of3FCCID:2ADDW-WIM10 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 CoilAntenna Page3of3FCCID:2ADDW-WIM10 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5
Page 1 of 10 FCCID:2ADDW-WIM10 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RFExposureEvaluationReport 1.ProductInformation FCCID:2ADDW-WIM10 Numberoftestedsamples2 SamplenumberA101122114-1(Engineersample),A101122114-2(Normalsample) ProductNameMagneticSuctionWirelessCharging ModelNumberWIM10 PowerSupply USB-CInput:5V3A,9V2A,12V1.5A WirelessOutput:15W(Max)/10W/7.5W/5W ModulationTypeContinuousWave FrequencyRange110.3~205.0KHz AntennaTypeCoilAntenna HardwareversionV1.0 SoftwareversionS00 Accessories/ ExposurecategoryGeneralpopulation/uncontrolledenvironment EUTTypeProductionUnit DeviceTypeMobileDevice 2.EvaluationMethod PerKDB680106D01Section3.RFExposureRequirements; 1)ConsumerwirelesspowertransferdevicesapprovedunderPart18in somecaseshavetodemonstratecompliancewithRFexposurerequirements.Thepotentialfor exposuremustbeassessedaccordingtotheoperatingconfigurationsofthewirelesssystemand theexposureconditionsofusersandbystanders.RFexposuremustbeevaluatedwiththeclient device(s)beingchargedbytheprimaryatmaximumoutputpower.TheRFexposurerequirements mustbedeterminedinconjunctionwiththedeviceoperatingcharacteristics,accordingtothe mobileandportableexposurerequirementsinSection2.1091andSection2.1093oftherules.SAR andMPElimitsdonotcoverthefrequencyrangeforwirelesspowertransferapplicationswhich operatebelow100kHzand300kHzrespectively;therefore,RFexposurecomplianceneedstobe determinedwithrespectto1.1307(c)and(d)oftheFCCrules. 2)Basedonthedesignandimplementationofthepowertransfer application,itmustbeclearlyidentifiedifmobileorportableRFexposureconditionsapply.Devices thatareinstalledtoprovideseparationofatleast20cmfromusersandbystandersmayqualifyfor mobileexposureconditions.Forsomeconditionswhereusersandbystandersmaybeexposedat closerthan20cm,section2.1091(d)(4)oftherulesmayapply. 3)Fordevicesdesignedfortypicaldesktopapplications,suchawireless chargingpads,RFexposureevaluationshouldbeconductedassumingauserseparationdistance of15cm.EandHfieldstrengthmeasurementsornumericalmodelingmaybeusedtodemonstrate compliance.Measurementsshouldbemadefromallsidesandthetopoftheprimary/clientpair, withthe15cmmeasuredfromthecenteroftheprobe(s)totheedgeofthedevice.Emissions between100kHzto300kHzshouldbeassessedversusthelimitsat300kHzinTable1ofSection 1.1310:614V/mand1.63A/m.AKDBinquiryisrequiredtodeterminetheapplicableexposure limitsbelow100kHz. Page 2 of 10 FCCID:2ADDW-WIM10 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 4)Portableexposureconditionsfrom100kHzto6GHzaredetermined withrespecttoSARrequirements.ExistingSARsystemsandtestproceduresaregenerally intendedformeasurementsabove100MHz.Whilenumericalmodelingcanbeanalternative,the constraintsofsubstantialcomputationalresourcesatlowfrequenciescouldintroducefurther limitations.Underthesecircumstances,includingoperationsbelow100kHz,theCommissionmay consideracombinationofanalyticalanalysis,fieldstrength,radiatedandconductedpower measurements,inconjunctionwithsomelimitednumericalmodelingtoassesscompliance. 5)Dependingontheoperatingfrequency,existingSARandMPE measurementproceduresmaybeadaptedtoevaluatewirelesspowertransferdevicesfor compliancewithrespecttomobileorportableexposureconditions.Ifthegranteeoritstestlabhave anyquestionsregardingRFexposureevaluationtheyshouldcontacttheFCCLaboratorywith sufficientsystemoperatingconfigurationdetailstodetermineifRFexposureevaluationis necessaryand,ifrequired,howtoapplyspecifictestprocedures.Below100MHz,whenSAR testingisrequiredandthedeviceisoperatingatcloseproximitytopersons,informationondevice design,implementation,operatingconfigurations,exposureconditionsofusersandbystandersare neededtodeterminetheevaluationandtestingrequirements.Inaddition,theinfluenceofnearby objectsmayalsoneedconsiderationaccordingtothewirelesspowertransfersystem implementation;forexample,theeffectsofplacingthedevice,itscoilsorradiatingelementsonor nearmetallicsurfaces 3.EvaluationLimit 3.1Referevaluationmethod ANSIC95.1–1999:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoRadio FrequencyElectromagneticFields,3kHzto300GHz. FCCKDBpublication680106D01RFExposureWirelessChargingAppsv03:RFExposure ConsiderationsforLowPowerConsumerWirelessPowerTransferApplications FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1091:Radiofrequencyradiationexposureevaluation:mobiledevices FCCCFR47part18.107:Indusial,Scientific,andMedicalEquipment Page 3 of 10 FCCID:2ADDW-WIM10 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 3.2Limit LimitsforMaximumPermissibleExposure(MPE)/ControlledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3-3.06141.63*1006 3.0-301842/f4.89/f*900/f 2 6 30-30061.40.1631.06 300-1,500//f/3006 1,500-100,000//56 LimitsforMaximumPermissibleExposure(MPE)/UncontrolledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforGeneralPopulation/UncontrolledExposure 0.3-1.346141.63*10030 1.34-30824/f2.19/f*180/f 2 30 30-30027.50.0730.230 300-1,500//f/150030 1,500-100,000//1.030 F=frequencyinMHz *=Plane-waveequivalentpowerdensity AccordingtoFCCKDB680106D01Section3.RFExposureRequirementsclause3the Emission-Limitsinthefrequencyrangefrom100KHzto300KHzshouldbeassessedversus thelimitsat300KHzinTable1ofCFR47–Section1.310asfollowing(m…
Text truncated - open the document above for the full version.
Manufacturer:ShenzhenTopbandCo.,Ltd Model:WIM10 30mm 30mm
Page1of24FCCID:2ADDW-WIM10ReportNo.:LCSA101122114EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT For ShenzhenTopbandCo.,Ltd MagneticSuctionWirelessCharging TestModel:WIM10 Preparedfor:ShenzhenTopbandCo.,Ltd Address: TopbandIndustrialPark,LiyuanIndustrialZone,Tangtou, Shiyan,Bao’an,Shenzhen,518108,Guangdong,China Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address: 101,201BldgA&301BldgC,JujiIndustrialParkShajing Street,BaoanDistrict,Shenzhen,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:October18,2022 Numberoftestedsamples:2 Serialnumber:A101122114-1(Engineersample),A101122114-2(Normal sample) DateofTest:October18,2022~October24,2022 DateofReport:October25,2022 Page2of24FCCID:2ADDW-WIM10ReportNo.:LCSA101122114EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FCCCFR47PART15C ReportReferenceNo......................:LCSA101122114EA DateOfIssue......................................:October25,2022 TestingLaboratoryName..............:ShenzhenLCSComplianceTestingLaboratoryLtd. Address................................................: 101,201BldgA&301BldgC,JujiIndustrialParkShajingStreet, BaoanDistrict,Shenzhen,China TestingLocation/Procedure............ : FullapplicationofHarmonisedstandards■ PartialapplicationofHarmonisedstandards□ Otherstandardtestingmethod□ Applicant’sName.............................:ShenzhenTopbandCo.,Ltd Address................................................: TopbandIndustrialPark,LiyuanIndustrialZone,Tangtou,Shiyan, Bao’an,Shenzhen,518108,Guangdong,China TestSpecification Standard..............................................:FCCCFR47PART15C TestReportFormNo.........................:LCSEMC-1.0 TRFOriginator....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceof thematerial.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialdueto itsplacementandcontext. TestItemDescription.....................:MagneticSuctionWirelessCharging TradeMark..........................................:N/A TestModel...........................................:WIM10 PowerSupply......................................: USB-CInput:5V3A,9V2A,12V1.5A WirelessOutput:15W(Max)/10W/7.5W/5W Result..................................................: Positive Compiledby:Supervisedby:Approvedby: RoryHuang/AdministratorCaryLuo/Techniqueprincipal GavinLiang/Manager Page3of24FCCID:2ADDW-WIM10ReportNo.:LCSA101122114EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT TestResultPositive Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetest laboratory. TestReportNo.:LCSA101122114EA October25,2022 Dateofissue TestModel..............................:WIM10 EUT.........................................:MagneticSuctionWirelessCharging Applicant...............................:ShenzhenTopbandCo.,Ltd Address..................................: TopbandIndustrialPark,LiyuanIndustrialZone,Tangtou,Shiyan, Bao’an,Shenzhen,518108,Guangdong,China Telephone...............................:/ Fax..........................................:/ Manufacturer........................:ShenzhenTopbandCo.,Ltd Address...................................: TopbandIndustrialPark,LiyuanIndustrialZone,Tangtou,Shiyan, Bao’an,Shenzhen,518108,Guangdong,China Telephone...............................:/ Fax..........................................:/ Factory...................................:ShenzhenTopbandCo.,Ltd Address...................................: TopbandIndustrialPark,LiyuanIndustrialZone,Tangtou,Shiyan, Bao’an,Shenzhen,518108,Guangdong,China Telephone...............................:/ Fax..........................................:/ Page4of24FCCID:2ADDW-WIM10ReportNo.:LCSA101122114EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000October25,2022InitialIssue-- Page5of24FCCID:2ADDW-WIM10ReportNo.:LCSA101122114EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TABLEOFCONTENTS 1.GENERALINFORMATION........................................................................................................6 1.1DescriptionofDevice(EUT)...............................................................................................................6 1.2SupportequipmentList.......................................................................................................................6 1.3ExternalI/OCable..........................................................…
Text truncated - open the document above for the full version.
Page1of2FCCID:2ADDW-WIM10 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity PhotographsofTestSetup ConductedEmission-ACadapterchargemode RadiatedEmissionbelow30MHz-ACadapterchargemode Page2of2FCCID:2ADDW-WIM10 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RadiatedEmissionbelow1GHz-ACadapterchargemode
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.1103 MHz - 0.205 MHz | - |
Robotic Lawn Mower
Equipment Class
DTS - Digital Transmission System
Bluetooth wireless module
Equipment Class
DTS - Digital Transmission System
USB Charging Adapter
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
AERA LIGHT
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
2.4G WIFI-BLE Module
Equipment Class
DTS - Digital Transmission System