Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Sep 20, 2020
Application Purpose
Original Equipment
Date of Application
Sep 20, 2020
Equipment Note
Wireless Presentation System
Frequency Range
5745.00000000 - 5825.00000000
Company
Winner Wave Limited
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

2SHUDWLQJ,QVWUXFWLRQV %DVLF*XLGH :LUHOHVV3UHVHQWDWLRQ6\VWHP  For business use Model No. 7<:36WPS Basic Set 7<:3%WPS Transmitter 7<:3%& WPS USB-C Transmitter 7<:3%WPS Transmitter Set 7<:3%& WPS USB-C Transmitter Set * WPS is an abbreviation of ìWireless Presentation Systemî. 77 Thank you for purchasing the Panasonic product. ï Please read these instructions before operating this product and retain them for future reference.  ï %HVXUHWRUHDG³6DIHW\3UHFDXWLRQV ́ SDJHWR EHIRUHXVH ï These Operating Instructions are shared by TY-WPS1, TY-WP2B1, TY-WPB1, TY-WP2BC1 and TY-WPBC1. DPQX1530ZA/X1 DA0920TS0 -PB $FFHVVRULHV 5 6DIHW\3UHFDXWLRQV 2 3DUW1DPHV 6 )L[LQJWKH7UDQVPLWWHU&RQQHFWLRQ 12 &RQQHFWLRQ 8 %DVLF8VH 10 7UDQVPLWWHU([WHQVLRQ0HWKRG 3DLULQJ  13 ,QVWDOOLQJWKH5HFHLYHU 15 1RWHVRQ8VLQJ:LUHOHVV/$1 17 5HTXHVW5HJDUGLQJ6HFXULW\ 19 6SHFLILFDWLRQV 21 (QJOLVK WPS USB-C Transmitter SetWPS USB-C Transmitter SetWPS USB-C Transmitter SetWPS USB-C Transmitter SetWPS USB-C Transmitter Set 2 English 6DIHW\3UHFDXWLRQV:$51,1*6WRSXVLQJWKHSURGXFWLPPHGLDWHO\ZKHQDQDEQRUPDOLW\RUPDOIXQFWLRQRFFXUV5HPRYHWKHSRZHUSOXJLQWKHFDVHRIDQDEQRUPDOLW\ ï Smoke is emitted, or abnormal smell or sound occurs. ï Video or audio is not reproduced in some cases. ï Liquid such as water or a foreign object has entered inside the product. ï The product is deformed or damaged. Using the product in such states may cause a fire or electric shock. ï Remove the power plug from the outlet and request repair to the dealer where you purchased the product. ï It is necessary to remove the power plug to completely turn off the power of this product. ï Do not repair the product by the customer since it is dangerous. ï Use an outlet located at a position where the hand can reach easily so that the power plug can be removed quickly. 'RQRWLQVHUWIRUHLJQREMHFWVLQWRWKHSURGXFWDo not insert or drop metals or flammable items into the inside the product from the vent hole, etc.Smoke is emitted, or abnormal smell or sound occurs. ï Keep an eye on children in particular.  Ŷ $ERXW$&DGDSWRU 'RQRWXVHDQ$&DGDSWRURU$&DGDSWRUFDEOHRWKHUWKDQWKRVHVXSSOLHGZLWKWKLVSURGXFWUsing an AC adaptor or AC adaptor cable other than those supplied may cause an electric shock or fire due to short circuit or heat generation.&OHDQWKHSRZHUSOXJSHULRGLFDOO\WRSUHYHQWGXVWIURPDFFXPXODWLQJFailure to do so may cause a fire or electric shock due to moisture. ï Remove the power plug and wipe it with dry cloth. 'RQRWLQVHUWRUUHPRYHWKHSRZHUSOXJZLWKZHWKDQGDoing so may cause an electric shock.'RQRWXVHWKHRXWOHWRUZLULQJGHYLFHVH[FHHGLQJUDWHGYDOXHVRUZLWKFXUUHQWVRWKHUWKDQ௅9$&Using them exceeding rated values by connecting too many plugs in one outlet may cause a fire due to heat generation.,QVHUWWKHSRZHUSOXJVHFXUHO\WRWKHHQGInsufficient insertion may cause a fire due to an electric shock or heat generation. ï Do not use the product with a damaged plug or loose outlet. 3 English 'RQRWGDPDJHWKH$&DGDSWRUDQGSRZHUSOXJ by damaging, modifying, forcibly bending, twisting, pulling or bundling them, bringing them close to heat appliances, placing heavy items on them, etc. Doing so may cause a fire or electric shock due to short circuit or disconnection. ï Request the dealer for repair of the AC adaptor or power plug. 8VHWKHSURGXFWFPRUPRUHDZD\IURPDORFDWLRQZKHUHDFDUGLDFSDFHPDNHULVHPEHGGHGRadio waves may affect the operation of the pacemaker.'RQRWXVHWKHSURGXFWLQDQDLUSODQHThe operational safety may be impaired.'RQRWXVHWKHSURGXFWQHDUDQDXWRPDWLFGRRUILUHDODUPRURWKHUDXWRPDWLFFRQWUROGHYLFHVRadio waves from this product may affect automatic control devices, which may cause an operational error, resulting in an accident.'RQRWXVHWKHSURGXFWLQKRVSLWDORUDORFDWLRQZLWKPHGLFDOHTXLSPHQWRadio waves from this product may affect medical equipment, which may cause an operational error, resulting in an accident.'RQRWXVHWKHSURGXFWZKLOHWRXFKLQJLWIRUDORQJWLPHTouching the hot parts of the product and AC adaptor for a long time may cause a low-temperature burn*. * Persons with poor bloodstream (due to vascular impairment, poor blood circulation, diabetes or strong compression) or poor skin sensitivity (elderly persons) tend to get a low-temperature burn. 'RQRWWRXFKWKHSURGXFWDQG$&DGDSWRULILWEHJLQVWRWKXQGHUDoing so may cause an electric shock.'RQRWZHWWKHSURGXFWDoing so may cause a fire or electric shock.'RQRWSODFHWKHSURGXFWRQXQVWDEOHORFDWLRQVPlacing the product on a shaky table or an inclined location may cause an injury due to falling over or dropping.'RQRWUHPRYHRUPRGLI\WKHEDFNFRYHU FDELQHW .HHSWKHVFUHZVVXSSOLHGZLWKWKHUHFHLYHURXWRIUHDFKRILQIDQWVThe screws may be accidentally swallowed. ï In the event this occurs, consult a doctor immediately. )RULQVWDOODWLRQSOHDVHDVNDTXDOLILHGWHFKQLFLDQRUDGHDOHUIf installation is not carried out and secured correctly, it can cause falling accidents. 4 English 6DIHW\3UHFDXWLRQV &RQWLQXHG &$87,21 'RQRWEORFNWKHYHQWKROHRIWKLVSURGXFW'RQRWSXVKWKHSURGXFWLQWRDQDUURZDQGSRRUO\YHQWLODWHGVSDFHDoing so may cause heat to accumulate inside, resulting in a fire or malfunction.'RQRWSODFHDKHDY\LWHPRQWKHSURGXFWDoing so may cause a fire or malfunction.'RQRWSODFHWKHSURGXFWDWDKLJKWHPSHUDWXUHORFDWLRQKXPLGRUGXVW\ORFDWLRQRUORFDWLRQVXEMHFWWRRLOVPRNHRUVWHDP VXFKDVDFRRNLQJWDEOHDQGKXPLGLILHU Doing so may cause a fire or electric shock.:KHQUHPRYLQJWKHFRQQHFWLRQFDEOHVEHVXUHWRKROGWKHFRQQHFWRUDQGSXOOLWPulling the cord may damage the cord, resulting in a fire due to an electric shock or short circuit. :KHQWUDQVIHUULQJWKHSURGXFWUHPRYHWKHFRQQHFWLRQFDEOHVRIHTXLSPHQWEHIRUHKDQGFailure to do so may damage the cord or product, resulting in a fire or electric shock.:KHQ…

Text truncated - open the document above for the full version.

Attestation Statements

Winner Wave Limited Address: 4F-5, No.736, Jhongjheng Road, Jhonghe Dist., New Taipei City, Taiwan Tel: +886-2-82269979; Fax: +886-2-82269672 Email: [email protected] Attestation Letter 2020-08-05 Dear Sir or Madam, The Main chip, model: RTL8822BU, installed in our product Wireless Presentation System, model: TY-WPR1, FCC ID: 2ADFSTYWPR1, this chip supports BT, all 2.4G & 5G WIFI bands. But for marketing purpose, this chip in this product only supports BT & 5G Wi-Fi (5150-5250 MHz, 5725-5850 MHz) band. The other 2.4G & 5G WIFI bands was disabled to use by manufacture in the software, the end user has no capability to activate it. Sincerely Yours, Signature: Stan Chen Product Director

Cover Letter(s)

Winner Wave Limited Address: 4F-5, No.736, Jhongjheng Road, Jhonghe Dist., New Taipei City, Taiwan Tel: +886-2-82269979; Fax: +886-2-82269672 Email: [email protected] QA-FR-170-B 7/29/2014 FCC Authorization Date: 2020-08-03 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We Winner Wave Limited, the undersigned, hereby authorizes Bay Area Compliance Laboratories Corporation to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratories Corporation on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Signature: STAN CHEN PRODUCT DIRECTOR

External Photos

Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ200717003-RF Page 1 of 5 EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ200717003-RF Page 2 of 5 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ200717003-RF Page 3 of 5 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ200717003-RF Page 4 of 5 Adapter Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ200717003-RF Page 5 of 5 Cable

ID Label/Location Info

Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ200717003-RF EXHIBIT A - FCC ID LABEL AND LOCATION FCC ID Label FCC ID Label Location Information The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase (Labeling requirements per 2.925)

Internal Photos

Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ200717003-RF Page 1 of 4 EXHIBIT C - EUT INTERNAL PHOTOGRAPHS 5G Antenna 1 BT Antenna 5G Antenna 2 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ200717003-RF Page 2 of 4 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ200717003-RF Page 3 of 4 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ200717003-RF Page 4 of 4 BT Antrnna

RF Exposure Info

Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200717003-00C FCC Part 15.407 Page 13 of 111 §1.1307 (b) (1) & §2.1091- MAXIMUM PERMISSIBLE EXPOSURE (MPE) Applicable Standard According to subpart 15.247 (i) and subpart 1.1307 (b)(1), 2.1091 systems operating under the provisions of this section shall be operated in a manner that ensures the public is not exposed to RF energy level in excess of the communication guidelines. Limits for General Population/Uncontrolled Exposure Limits for General Population/Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Averaging Time (Minutes) 0.3-1.34 614 1.63 *(100) 30 1.34-30 824/f 2.19/f *(180/f 2 ) 30 30-300 27.5 0.073 0.2 30 300-1500 / / f/1500 30 1500-100,000 / / 1.0 30 f = frequency in MHz * = Plane-wave equivalent power density Result Calculated Formulary: Predication of MPE limit at a given distance S = 2 4R PG  S = power density (in appropriate units, e.g. mW/cm2) P = power input to the antenna (in appropriate units, e.g., mW). G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain factor, is normally numeric gain. R = distance to the center of radiation of the antenna (appropriate units, e.g., cm) Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200717003-00C FCC Part 15.407 Page 14 of 111 Frequency (MHz) Antenna Gain Tune up conducted power Evaluation Distance (cm) Power Density (mW/cm 2 ) MPE Limit (mW/cm 2 ) (dBi) (numeric) (dBm)(mW) 2402-2480(BT) 3.05 2.02 6.5 4.47 20 0.002 1 2402-2480(BLE) 3.05 2.02 4.5 2.82 20 0.001 1 5150-5250 4.42 2.77 12.0 15.85 20 0.009 1 5725-5850 4.42 2.77 12.5 17.78 20 0.010 1 Note: 1) To maintain compliance with the FCC’s RF exposure guidelines, place the equipment at least 20cm from nearby persons. 2) Bluetooth and 5GHz Wi-Fi can transmit simultaneously for this device. 3) Simultaneous transmitting consideration: The ratio=MPE DSS /limit+MPE NII /limit=0.002+0.010=0.012<1.0, so simultaneous exposure is not required. Result: Pass

Test Report

Note: This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “★”. BACL is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with an asterisk ’*’. Customer model name, addresses, names, trademarks etc. are not considered data. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. FCC PART 15.407 TEST REPORT For Winner Wave Limited 4F-5, No.736, Jhongjheng Road, Jhonghe Dist., New Taipei City, Taiwan FCC ID: 2ADFSTYWPR1 Report Type: Original Report Product Type: Wireless Presentation System Re port Number: RSZ200717003-00C Re port Date: 2020-09-11 Reviewed B y: Nancy Wang RF En gineer Prepared By: Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road, Futian Free Trade Zone, Shenzhen, Guangdong, China Tel: +86-755-33320018 Fax: +86-755-33320008 www.baclcorp.com.cn Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200717003-00C FCC Part 15.407 Page 2 of 111 TABLE OF CONTENTS GENERAL INFORMATION ....................................................................................................................................... 4 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 4 OBJECTIVE ................................................................................................................................................................... 4 TEST METHODOLOGY .................................................................................................................................................. 4 MEASUREMENT UNCERTAINTY .................................................................................................................................... 5 TEST FACILITY ............................................................................................................................................................. 5 SYSTEM TEST CONFIGURATION .......................................................................................................................... 6 DESCRIPTION OF TEST CONFIGURATION ...................................................................................................................... 6 EUT EXERCISE SOFTWARE .......................................................................................................................................... 7 DUTY CYCLE ................................................................................................................................................................ 7 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 8 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................... 8 EXTERNAL I/O CABLE .................................................................................................................................................. 8 BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................ 9 SUMMARY OF TEST RESULTS ............................................................................................................................. 10 TEST EQUIPMENT LIST ......................................................................................................................................... 11 §1.1307 (b) (1) & §2.1091- MAXIMUM PERMISSIBLE EXPOSURE (MPE) .......................................................... 13 APPLICABLE STANDARD ............................................................................................................................................ 13 RESULT ...................................................................................................................................................................... 13 FCC §15.203 – ANTENNA REQUIREMENT .......................................................................................................... 15 APPLICABLE STANDARD ............................................................................................................................................ 15 ANTENNA CONNECTOR CONSTRUCTION .................................................................................................................... 15 FCC §15.407 (b) (6) §15.207 (a) – CONDUCTED EMISSIONS ............................................................................. 16 APPLICABLE STANDARD ............................................................................................................................................ 16 EUT SETUP ................................................................................................................................................................ 16 EMI TEST RECEIVER SETUP ....................................................................................................................................... 16 TEST PROCEDURE ...................................................................................................................................................... 16 TEST DATA ................................................................................................................................................................ 17 §15.205 & §15.209 & §15.407(B) (1), (4), (6), (7) – UNDESIRABLE EMISSION ..........................................…

Text truncated - open the document above for the full version.

Test Report

Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200717003-00C FCC Part 15.407 Page 73 of 111 Appendix A3: Min emission bandwidth Test Result TestMode Antenna Channel 6db EBW [MHz] Limit[MHz] Verdict 11AMIMO Ant1 574516.3600.5 PASS Ant2 574516.4000.5 PASS Ant1 578516.4000.5 PASS Ant2 578516.4000.5 PASS Ant1 582516.4000.5 PASS Ant2 582516.4000.5 PASS 11N20MIMO Ant1 574517.0000.5 PASS Ant2 574516.6400.5 PASS Ant1 578516.6400.5 PASS Ant2 578516.6400.5 PASS Ant1 582517.0000.5 PASS Ant2 582516.6400.5 PASS 11N40MIMO Ant1 575536.2400.5 PASS Ant2 575536.0000.5 PASS Ant1 579536.0000.5 PASS Ant2 579536.2400.5 PASS 11AC20MIMO Ant1 574517.0000.5 PASS Ant2 574516.9600.5 PASS Ant1 578517.0000.5 PASS Ant2 578516.6400.5 PASS Ant1 582517.0000.5 PASS Ant2 582516.6400.5 PASS 11AC40MIMO Ant1 575536.2400.5 PASS Ant2 575536.0000.5 PASS Ant1 579536.2400.5 PASS Ant2 579536.0000.5 PASS 11AC80MIMO Ant1 577575.5200.5 PASS Ant2 577575.5200.5 PASS Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200717003-00C FCC Part 15.407 Page 74 of 111 Test Graphs 11AMIMO_Ant1_5745 11AMIMO_Ant2_5745 11AMIMO_Ant1_5785 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200717003-00C FCC Part 15.407 Page 75 of 111 11AMIMO_Ant2_5785 11AMIMO_Ant1_5825 11AMIMO_Ant2_5825 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200717003-00C FCC Part 15.407 Page 76 of 111 11N20MIMO_Ant1_5745 11N20MIMO_Ant2_5745 11N20MIMO_Ant1_5785 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200717003-00C FCC Part 15.407 Page 77 of 111 11N20MIMO_Ant2_5785 11N20MIMO_Ant1_5825 11N20MIMO_Ant2_5825 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200717003-00C FCC Part 15.407 Page 78 of 111 11N40MIMO_Ant1_5755 11N40MIMO_Ant2_5755 11N40MIMO_Ant1_5795 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200717003-00C FCC Part 15.407 Page 79 of 111 11N40MIMO_Ant2_5795 11AC20MIMO_Ant1_5745 11AC20MIMO_Ant2_5745 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200717003-00C FCC Part 15.407 Page 80 of 111 11AC20MIMO_Ant1_5785 11AC20MIMO_Ant2_5785 11AC20MIMO_Ant1_5825 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200717003-00C FCC Part 15.407 Page 81 of 111 11AC20MIMO_Ant2_5825 11AC40MIMO_Ant1_5755 11AC40MIMO_Ant2_5755 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200717003-00C FCC Part 15.407 Page 82 of 111 11AC40MIMO_Ant1_5795 11AC40MIMO_Ant2_5795 11AC80MIMO_Ant1_5775 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200717003-00C FCC Part 15.407 Page 83 of 111 11AC80MIMO_Ant2_5775 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200717003-00C FCC Part 15.407 Page 84 of 111 Appendix B: Maximum conducted output power Test Result TestMode Antenna Channel Result[dBm] Limit[dBm] Verdict 11AMIMO Ant1 51808.74<=30 PASS Ant2 51807.69<=30 PASS total518011.25<=30 PASS Ant1 52009.01<=30 PASS Ant2 52007.59<=30 PASS total520011.37<=30 PASS Ant1 52409.18<=30 PASS Ant2 52407.25<=30 PASS total524011.33<=30 PASS Ant1 57459.65<=30 PASS Ant2 57457.27<=30 PASS total574511.63<=30 PASS Ant1 57859.63<=30 PASS Ant2 57857.50<=30 PASS total578511.70<=30 PASS Ant1 58259.46<=30 PASS Ant2 58257.03<=30 PASS total582511.42<=30 PASS 11N20MIMO Ant1 51808.78<=30 PASS Ant2 51807.71<=30 PASS total518011.29<=30 PASS Ant1 52009.04<=30 PASS Ant2 52007.72<=30 PASS total520011.44<=30 PASS Ant1 52409.17<=30 PASS Ant2 52407.38<=30 PASS total524011.38<=30 PASS Ant1 57459.50<=30 PASS Ant2 57457.50<=30 PASS total574511.62<=30 PASS Ant1 57859.59<=30 PASS Ant2 57857.45<=30 PASS total578511.66<=30 PASS Ant1 58259.44<=30 PASS Ant2 58256.87<=30 PASS total582511.35<=30 PASS 11N40MIMO Ant1 51909.27<=30 PASS Ant2 51908.17<=30 PASS total519011.77<=30 PASS Ant1 52309.59<=30 PASS Ant2 52307.97<=30 PASS total523011.87<=30 PASS Ant1 575510.06<=30 PASS Ant2 57558.09<=30 PASS total575512.20<=30 PASS Ant1 57959.99<=30 PASS Ant2 57957.69<=30 PASS total579512.00<=30 PASS Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200717003-00C FCC Part 15.407 Page 85 of 111 11AC20MIMO Ant151808.81<=30 PASS Ant251807.70<=30 PASS total518011.30<=30 PASS Ant152009.06<=30 PASS Ant252007.70<=30 PASS total520011.44<=30 PASS Ant152409.14<=30 PASS Ant252407.38<=30 PASS total524011.36<=30 PASS Ant157459.55<=30 PASS Ant257457.44<=30 PASS total574511.63<=30 PASS Ant157859.60<=30 PASS Ant257857.50<=30 PASS total578511.69<=30 PASS Ant158259.37<=30 PASS Ant258257.19<=30 PASS total582511.43<=30 PASS 11AC40MIMO Ant151909.35<=30 PASS Ant251908.36<=30 PASS total519011.89<=30 PASS Ant152309.57<=30 PASS Ant252307.95<=30 PASS total523011.85<=30 PASS Ant1575510.07<=30 PASS Ant257558.17<=30 PASS total575512.23<=30 PASS Ant157959.96<=30 PASS Ant257957.74<=30 PASS total579512.00<=30 PASS 11AC80MIMO Ant152109.08<=30 PASS Ant252107.59<=30 PASS total521011.41<=30 PASS Ant157759.85<=30 PASS Ant257757.63<=30 PASS total577511.89<=30 PASS Note: The Duty Cycle Factor is compensated in the final result. Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200717003-00C FCC Part 15.407 Page 86 of 111 Appendix C: Maximum power spectral density Test Result TestMode Antenna Channel Result [dBm/MHz] Limit[dBm/MHz] Verdict 11AMIMO Ant1 51802.78<=17 PASS Ant2 51801.65<=17 PASS total51805.26<=17 PASS Ant1 52002.8<=17 PASS Ant2 52001.26<=17 PASS total52005.11<=17 PASS Ant1 52402.95<=17 PASS Ant2 52400.81<=17 PASS total52405.02<=17 PASS Ant1 57451.54<=30 PASS Ant2 5745-0.4<=30 PASS total57453.69<=30 PASS Ant1 57851.51<=30 PASS Ant2 5785-0.41<=30 PASS total57853.67<=30 PASS Ant1 58251.37<=30 PASS Ant2 5825-0.65<=30 PASS total58253.49<=30 PASS 11N20MIMO Ant1 51801.53<=17 PASS Ant2 51800.48<=17 PASS total51804.05<=17 PASS Ant1 52001.45<=17 PASS Ant2 52000.69<=17 PASS total52004.10<=17 PASS Ant1 52401.91<=17 PASS Ant2 52400.72<=17 PASS total52404.37<=17 PASS Ant1 57450.64<=30 PASS Ant2 5745-1.1<=30 PASS total57452.87<=30 PASS Ant1 57850.54<=30 PASS Ant2 5785-1.16<=30 PASS…

Text truncated - open the document above for the full version.

Test Setup Photos

Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ200717003-RF Page 1 of 2 EXHIBIT D - TEST SETUP PHOTOGRAPHS Conducted Emissions - Front View Conducted Emissions - Side View Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ200717003-RF Page 2 of 2 Radiated Emissions – Front View (Below 1 GHz) Radiated Emissions View (Above 1 GHz)

Contact Information

Applicant

Rock Huang(Technical Manager)
[email protected]+886-2-82269979Fax: +886-2-82269672

Test Firm

Bay Area Compliance Laboratories Corp. (Shenzhen)Well Wang
[email protected]+86 (0) 755 33320018

Technical Specifications

#Rule PartsFrequency RangePower Output
215E5.75 GHz - 5.83 GHz17.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device supports 20 MHz, 40 MHz and 80 MHz bandwidth modes.

Other Applications from Winner Wave Limited

2ADFS-POCKET-R-1D

Pocket

Jan 28, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
2ADFS-CAMCAST-CT1

CamCast

Dec 23, 2025

Equipment Class

NII - Unlicensed National Information Infrastructure TX
2ADFS-MINIPOCKET-H1

Mini Pocket

Dec 02, 2024

Equipment Class

NII - Unlicensed National Information Infrastructure TX
2ADFS-ULTRA-U2

Ultra

Oct 10, 2024

Equipment Class

DTS - Digital Transmission System
2ADFS-POCKET-RC-1

Pocket

Sep 05, 2024

Equipment Class

NII - Unlicensed National Information Infrastructure TX