FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Xwireless LLC/
  3. 2ADLJ-CB68

2ADLJ-CB68Mobile Phone

Xwireless LLC

Application Details

Equipment Class
PCE - PCS Licensed Transmitter held to ear
Date of Grant
Nov 28, 2024
Application Purpose
Original Equipment
Date of Application
Nov 28, 2024
Equipment Note
Mobile Phone
Frequency Range
670.50000000 - 690.50000000
Company
Xwireless LLC
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗
↗

Test Report

↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Xwireless LLC 2.911 (d)(5)(i) Equipment Type Attestation v1.2 Section 2.911(d)(5)(i) Certification – Equipment Type Company name: Xwireless LLC Address: 11565 Old Georgetown Road, Rockville, MD, USA Product Name: Mobile Phone FCC ID: 2ADLJ-CB68 Model(s): CB68 2.911(d)(5)(i) Equipment Type We, [Xwireless LLC ] (“the applicant”) certify that the equipment for which authorization is sought through certification is not:  Prohibited from receiving an equipment authorization pursuant to § 2.903; of the FCC rules.  Identified as an equipment type in the “Covered List” NOTE 1 Yours sincerely, Name: Paul Greene Date: 2024-11-26 Title and Company name: CEO NOTE 1 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the

Attestation Statements

Xwireless LLC 2.911 (d)(5)(ii) Applicant Attestation v1.2 Section 2.911(d)(5)(ii) Certification – Applicant (Covered List ) Company name: Xwireless LLC Address: 11565 Old Georgetown Road, Rockville, MD, USA Product Name: Mobile Phone FCC ID: 2ADLJ-CB68 Model(s): CB68 2.911(d)(5)(ii) Applicant filing We, [Xwireless LLC ] (“the applicant”) certify that, as of the date of the filing of the application, the applicant is not identified NOTE 1 on the “Covered List” NOTE 2 , established pursuant to § 1.50002 of this chapter, as an entity producing covered communications equipment. Yours sincerely, Name: Paul Greene Date: 2024-11-26 Title and Company name: CEO NOTE 1 Delete option not applicable to this application. NOTE 2 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the

Attestation Statements

Xwireless LLC 2.911 (d)(7)USA Agent v1.2 Section 2.911(d)(7) USA Agent for Service of Process Company name: Xwireless LLC Address: 11565 Old Georgetown Road, Rockville, MD, USA Product Name: Mobile Phone FCC ID: 2ADLJ-CB68 Model(s): CB68 2.911(d)(7) USA Designated Agent for Service of Process We, [Xwireless LLC ] (“the applicant”) designate [Xwireless LLC] NOTE1 for the purpose of accepting service of process on behalf of the applicant. Applicant consent: We Acknowledge our consent to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address of the designated agent and acknowledge our acceptance of our obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. Agent obligation: We Acknowledge our obligation to accept service of process in the United States for matters related to the applicable equipment at our physical U.S. address and email address for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. USA Agent Company name: Xwireless LLC Address: 11565 Old Georgetown Road, Rockville, MD, USA FRN: 0024077745 Contact Name: Paul Greene Telephone No: (301) 412-4412 Email: [email protected] Applicant Company name: Xwireless LLC Address: 11565 Old Georgetown Road, Rockville, MD, USA FRN: 0024077745 FCC Grantee Code: 2ADLJ Contact Name: Paul Greene Telephone No: (301) 412-4412 Email: [email protected] Signature: Title: CEO Signature: Title: CEO Date: 2024-11-26 Date: 2024-11-26 Xwireless LLC 2.911 (d)(7)USA Agent v1.2 NOTE 1: An applicant located in the United States may designate itself as the agent for service of process. Reference; Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-t o-the-communications-supply-chain-through-the

Cover Letter(s)

Xwireless LLC Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 2024-11-26 Subject; Request for Long Term Confidentiality FCC ID: 2ADLJ-CB68 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram BOM Operational Description Tune-up Procedure Pursuant to Public Notice DA 04-1705 of the Commission' s policy, in order to comply with the marketing regulations in 47 CFT §2.803 and the importation rules in 47 CFR §2.1204.while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Internal Photos User Manual 口 For45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Paul Greene Title: CEO

Cover Letter(s)

Letter of Authorization Company: Xwireless LLC Address: 11565 Old Georgetown Road, Rockville, MD, USA Product Name: Mobile Phone Model Number: CB68 FCC Identifier: 2ADLJ-CB68 We authorize MiCOM Labs Inc, 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the above named equipment. Any individual within MiCOM Labs is authorized to act on our behalf and take action on the application. We declare that MiCOM Labs Inc, 575 Boulder Court, Pleasanton, California 94566, USA, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Name: Paul Greene Date: 2024-11-26 Title: CEO

ID Label/Location Info

Label&Location Vortex MobilePhone Model:CB68 FCCID:2ADLJ-CB68

RF Exposure Info

Any reproduction of this document must be done in full. No single part of this document may be reproduced without permission from STS, All Test Data Presented in this report is only applicable to presented Test sample. ShenZhen STS Test Services Co.,Ltd. A 1/F, Building B, Zhuoke Science Park, No.190 Chongqing Road, HepingShequ, Fuyong Sub-District, Bao’an District, Shenzhen, Guang Dong, China TEL: +86-755 3688 6288 FAX: +86-755 3688 6277 E-mail:[email protected] S T L A B S Testing Engineer : (Xin.Liu) Technical Manager : (Shifan. Long) Authorized Signatory : (Bovey Yang) SAR Dipole Performance Measurement Report EUT Type: SAR Validation Dipole and Waveguide Model Name: DIP0G750, DIP0G835, DIP1G900, DIP2G450 Brand Name: SATIMO Test Conclusion: Pass Test Date: 01 July 2024 Date of Issue: 01 July 2024 ISSUED BY Shenzhen STS Test Services Co., Ltd. 1. Equipment List Kind of Equipment Manufacturer Type No. Serial No. Last Calibration Calibrated Until PC Acer N/A N/A N/A N/A E-Field Probe MVG SSE2 SN 07/21 EPGO352 2024.02.14 2025.02.13 Dielectric Probe Kit MVG SCLMP SN 32/14 OCPG67 2023.10.25 2024.10.24 Phantom1 MVG SAM SN 32/14 SAM115 N/A N/A Phantom3 MVG SAM SN 21/21 ELLI48 N/A N/A Attenuator Agilent 99899 DC-18GHz N/A N/A Directional coupler Narda 4226-20 3305 N/A N/A Network Analyzer Agilent E5071C MY46520378 2023-09-26 2024-09-25 Multi Meter Keithley Multi Meter 2000 4050073 2023-09-26 2024-09-25 Signal Generator Agilent ZHL-42W 9638 2023.10.07 2024.10.06 Power Amplifier DESAY NRP 100510 2023-09-26 2024-09-25 Power Meter R&S NRP-Z11 101919 2023-09-26 2024-09-25 Power Sensor R&S U2021XA MY56280002 2023-09-26 2024-09-25 Temperature hygrometer SuWei SW-108 N/A 2023.09.28 2024.09.27 Thermograph Elitech RC-4 S/N EF7176501537 2023.10.12 2024.10.11 ISSUED BY Shenzhen STS Test Services Co., Ltd. 2. <Justification of the extended calibration> Referring to KDB 865664 D01, if dipoles are verified in return loss<-20dB, (within 20% of prior calibration), and in impedance (within 5 ohm of prior calibration), the annual calibration is not necessary and the calibration interval can be extended. Head 750 MHz Date of Measurement Return Loss (dB) Delta (%) Impedance Delta(ohm) 2023.07.04 -25.47 - 55.2 - 2024.07.01 -24.06 -5.54 53.63 -1.57 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. <Dipole Verification Data> Head 750 MHz ISSUED BY Shenzhen STS Test Services Co., Ltd. Body 750 MHz Date of Measurement Return Loss (dB) Delta (%) Impedance Delta(ohm) 2023.07.04 -27.25 - 51.4 - 2024.07.01 -27.27 0.07 51.36 -0.04 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. <Dipole Verification Data> Body 750 MHz ISSUED BY Shenzhen STS Test Services Co., Ltd. Head 835 MHz Date of Measurement Return Loss (dB) Delta (%) Impedance Delta(ohm) 2023.07.04 -28.13 - 51.4 - 2024.07.01 -28.83 2.49 52.65 1.25 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. <Dipole Verification Data> Head 835MHz ISSUED BY Shenzhen STS Test Services Co., Ltd. Body 835 MHz Date of Measurement Return Loss (dB) Delta (%) Impedance Delta(ohm) 2023.07.04 -23.88 - 49.2 - 2024.07.01 -25.02 4.77 50.76 1.56 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. <Dipole Verification Data> Body 835MHz ISSUED BY Shenzhen STS Test Services Co., Ltd. Head 2000 MHz Date of Measurement Return Loss (dB) Delta (%) Impedance Delta(ohm) 2023.07.04 -23.66 - 51.4 - 2024.07.01 -23.89 0.97 51.23 -0.17 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. <Dipole Verification Data> Head 1900 MHz ISSUED BY Shenzhen STS Test Services Co., Ltd. Body 2000 MHz Date of Measurement Return Loss (dB) Delta (%) Impedance Delta(ohm) 2023.07.04 -20.20 - 48.7 - 2024.07.01 -21.93 8.56 47.91 -0.79 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. <Dipole Verification Data> Body 1900 MHz ISSUED BY Shenzhen STS Test Services Co., Ltd. Head 2450 MHz Date of Measurement Return Loss (dB) Delta (%) Impedance Delta(ohm) 2023.07.04 -26.03 - 46.3 - 2024.07.01 -26.91 3.38 47.40 1.1 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. <Dipole Verification Data> Head 2450 MHz ISSUED BY Shenzhen STS Test Services Co., Ltd. Body 2450 MHz Date of Measurement Return Loss (dB) Delta (%) Impedance Delta(ohm) 2023.07.04 -32.76 - 48.7 - 2024.07.01 -33.75 3.02 49.28 0.58 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. <Dipole Verification Data> Body 2450 MHz

RF Exposure Info

Ref : ACR.262.4.2.MVGB.A SHENZHEN STS TEST SERVICES CO., LTD. 1/F., BUILDING 2, ZHUOKE SCIENCE PARK,No.190, CHONGQING ROAD,FUYONG STREET, BAO’ AN DISTRICT, SHENZHEN,GUANGDONG,CHINA MVG COMOSAR REFERENCE DIPOLE FREQUENCY: 750 MHZ SERIAL NO.: SN 30/14 DIP0G750-331 SAR Reference Dipole Calibration Report Calibrated at MVG Z.I. de la pointe du diable Technopôle Brest Iroise - 295 avenue Alexis de Rochon 29280 PLOUZANE - FRANCE Calibration date: Summary: Page: 1/11 3 07/04/2023 Accreditations #2-6789 and #2-6814 Scope available on www.cofrac.fr This document presents the method and results from an accredited SAR reference dipole calibration performed in MVG using the COMOSAR test bench. All calibration results are traceable to national metrology institutions. SAR REFERENCE DIPOLE CALIBRATION REPORT Ref: ACR.262.4.2.MVGB.A Customer Name Distribution : Shenzhen STS Test Services Co., Ltd. Name Function Date Signature Prepared by : Jérôme LUC Technical Manager 7/0 /202 Checked by : Jérôme LUC Technical Manager Approved by : Yann Toutain Laboratory Director Issue Date Modifications A Initial release Name Jérôme LUC Page: 2/11 Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Dipole vH Th is document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. 3 4 7/0 /202 3 4 7/0 /202 3 4 7/0 /202 3 4 3 SAR REFERENCE DIPOLE CALIBRATION REPORT TABLE OF CONTENTS 1 Introduction ................................................................................................................ 4 2 Device Under Test ..................................................................................................... 4 3 Product Description ................................................................................................... 4 3.1 General Information _______________________________________________________ 4 4 Measurement Method ................................................................................................ 5 4.1 Return Loss Requirements __________________________________________________ 5 4.2 Mechanical Requirements ___________________________________________________ 5 5 Measurement Uncertainty .......................................................................................... 5 5.1 Return Loss ______________________________________________________________ 5 5.2 Dimension Measurement ___________________________________________________ 5 5.3 Validation Measurement ____________________________________________________ 5 6 Calibration Measurement Results .............................................................................. 6 6.1 Return Loss and Impedance In Head Liquid ____________________________________ 6 6.2 Return Loss and Impedance In Body Liquid ____________________________________ 6 6.3 Mechanical Dimensions ____________________________________________________ 6 7 Validation measurement ............................................................................................ 7 7.1 Head Liquid Measurement __________________________________________________ 7 7.2 SAR Measurement Result With Head Liquid ____________________________________ 8 7.3 Body Liquid Measurement __________________________________________________ 9 7.4 SAR Measurement Result With Body Liquid __________________________________ 10 8 List of Equipment .................................................................................................... 11 Page: 3/11 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Dipole vH Ref: ACR.262.4.2.MVGB.A 3 SAR REFERENCE DIPOLE CALIBRATION REPORT 1 INTRODUCTION This document contains a summary of the requirements set forth by the IEEE 1528, OET 65 Bulletin C and CEI/IEC 62209 standards for reference dipoles used for SAR measurement system validations and the measurements that were performed to verify that the product complies with the fore mentioned standards. 2 DEVICE UNDER TEST Device Under Test Device Type COMOSAR 750 MHz REFERENCE DIPOLE Manufacturer MVG Model SID750 Serial Number SN 30/14 DIP0G750-331 Product Condition (new / used) Used A yearly calibration interval is recommended. 3 PRODUCT DESCRIPTION 3.1 GENERAL INFORMATION MVG’s COMOSAR Validation Dipoles are built in accordance to the IEEE 1528, OET 65 Bulletin C and CEI/IEC 62209 standards. The product is designed for use with the COMOSAR test bench only. Figure 1 – MVG COMOSAR Validation Dipole Page: 4/11 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Dipole vH Ref: ACR.262.4.2.MVGB.A 3 SAR REFERENCE DIPOLE CALIBRATION REPORT 4 MEASUREMENT METHOD The IEEE 1528, OET 65 Bulletin C and CEI/IEC 62209 standards provide requirements for reference dipoles used for system validation measurements. The following measurements were performed to verify that the product complies with the fore mentioned standards. 4.1 RETURN LOSS REQUIREMENTS The dipole used for SAR system validation measurements and checks must have a return loss of -20 dB or better. The return loss measurement shall be performed against a liquid filled flat phantom, with the phantom constucted as outlined in the fore mentioned standards. 4.2 MECHANICAL REQUIREMENTS The IEEE Std. 1528 and CEI/IEC 62209 standards specify the mechanical components and dimensions of the validation dipoles, with the dimensions frequency and phanto…

Text truncated - open the document above for the full version.

Test Report

1.Effective(Isotropic)RadiatedPowerOutputData 1.1TestResult 1.1.1GSM850_ERP Band:GSM850 ENV Mode Frequency (MHz) ConductedPower (dBm) Gain (dBi) ERP(dBm) Verdict NetworkSubsetResultLimit NTNV GSMGSM 824.231.18-1.4327.60<=38.45Pass 836.631.09-1.4327.51<=38.45Pass 848.830.98-1.4327.40<=38.45Pass GPRS 1TXSlot824.231.20-1.4327.62<=38.45Pass 2TXSlots824.229.15-1.4325.57<=38.45Pass 3TXSlots824.227.27-1.4323.69<=38.45Pass 4TXSlots824.225.09-1.4321.51<=38.45Pass 1TXSlot836.631.06-1.4327.48<=38.45Pass 2TXSlots836.629.02-1.4325.44<=38.45Pass 3TXSlots836.627.17-1.4323.59<=38.45Pass 4TXSlots836.625.04-1.4321.46<=38.45Pass 1TXSlot848.830.94-1.4327.36<=38.45Pass 2TXSlots848.828.93-1.4325.35<=38.45Pass 3TXSlots848.827.09-1.4323.51<=38.45Pass 4TXSlots848.824.96-1.4321.38<=38.45Pass EGPRS 1TXSlot824.224.14-1.4320.56<=38.45Pass 2TXSlots824.223.76-1.4320.18<=38.45Pass 3TXSlots824.222.39-1.4318.81<=38.45Pass 4TXSlots824.219.83-1.4316.25<=38.45Pass 1TXSlot836.623.82-1.4320.24<=38.45Pass 2TXSlots836.623.57-1.4319.99<=38.45Pass 3TXSlots836.622.35-1.4318.77<=38.45Pass 4TXSlots836.619.70-1.4316.12<=38.45Pass 1TXSlot848.823.90-1.4320.32<=38.45Pass 2TXSlots848.823.54-1.4319.96<=38.45Pass 3TXSlots848.822.42-1.4318.84<=38.45Pass 4TXSlots848.819.85-1.4316.27<=38.45Pass Note1:ERP=ConductedPower+AntennaGain-2.15 2.FrequencyStability 2.1TestResult 2.1.1GSM850 Band:GSM850 Network Frequency (MHz) Temp. (°C) Voltage (VDC) Freq.Error (Hz) Freq.vs.Rated(ppm) Verdict ResultLimit GSM824.2 20 3.276.4570.0078-2.5to2.5Pass 3.85-1.033-0.0013-2.5to2.5Pass 4.43-5.069-0.0062-2.5to2.5Pass -303.852.3570.0029-2.5to2.5Pass -203.855.2950.0064-2.5to2.5Pass -103.85-1.550-0.0019-2.5to2.5Pass 03.85-1.485-0.0018-2.5to2.5Pass 103.855.9410.0072-2.5to2.5Pass 303.8513.4310.0163-2.5to2.5Pass 403.857.5550.0092-2.5to2.5Pass 503.855.4890.0067-2.5to2.5Pass 836.6 20 3.270.1940.0002-2.5to2.5Pass 3.85-4.843-0.0058-2.5to2.5Pass 4.43-7.652-0.0091-2.5to2.5Pass -303.85-2.873-0.0034-2.5to2.5Pass -203.85-4.229-0.0051-2.5to2.5Pass -103.852.4210.0029-2.5to2.5Pass 03.85-1.453-0.0017-2.5to2.5Pass 103.851.6790.0020-2.5to2.5Pass 303.850.5490.0007-2.5to2.5Pass 403.85-9.105-0.0109-2.5to2.5Pass 503.853.8420.0046-2.5to2.5Pass 848.8 20 3.275.0370.0059-2.5to2.5Pass 3.856.0050.0071-2.5to2.5Pass 4.434.7140.0056-2.5to2.5Pass -303.85-3.067-0.0036-2.5to2.5Pass -203.85-5.876-0.0069-2.5to2.5Pass -103.85-3.390-0.0040-2.5to2.5Pass 03.85-9.331-0.0110-2.5to2.5Pass 103.855.7150.0067-2.5to2.5Pass 303.856.4570.0076-2.5to2.5Pass 403.8512.7850.0151-2.5to2.5Pass 503.856.3930.0075-2.5to2.5Pass GPRS 824.2 20 3.2715.6260.0190-2.5to2.5Pass 3.8511.5580.0140-2.5to2.5Pass 4.4310.5570.0128-2.5to2.5Pass -303.8512.3330.0150-2.5to2.5Pass -203.8511.5260.0140-2.5to2.5Pass -103.859.9440.0121-2.5to2.5Pass 03.857.5230.0091-2.5to2.5Pass 103.858.3300.0101-2.5to2.5Pass 303.856.9740.0085-2.5to2.5Pass 403.858.0710.0098-2.5to2.5Pass 503.858.4910.0103-2.5to2.5Pass 836.6 20 3.273.6810.0044-2.5to2.5Pass 3.857.1670.0086-2.5to2.5Pass 4.436.9740.0083-2.5to2.5Pass -303.851.6470.0020-2.5to2.5Pass -203.850.7750.0009-2.5to2.5Pass -103.852.5510.0030-2.5to2.5Pass 03.857.2320.0086-2.5to2.5Pass 103.852.3570.0028-2.5to2.5Pass 303.858.5230.0102-2.5to2.5Pass 403.857.7810.0093-2.5to2.5Pass 503.854.9720.0059-2.5to2.5Pass 848.8 20 3.279.2660.0109-2.5to2.5Pass 3.857.7810.0092-2.5to2.5Pass 4.438.2970.0098-2.5to2.5Pass -303.858.9110.0105-2.5to2.5Pass -203.855.9080.0070-2.5to2.5Pass -103.857.2320.0085-2.5to2.5Pass 03.857.3610.0087-2.5to2.5Pass 103.853.6810.0043-2.5to2.5Pass 303.855.3920.0064-2.5to2.5Pass 403.857.9420.0094-2.5to2.5Pass 503.854.5850.0054-2.5to2.5Pass EGPRS824.2203.2716.3040.0198-2.5to2.5Pass 3.8510.0730.0122-2.5to2.5Pass 4.4312.9140.0157-2.5to2.5Pass -303.859.0400.0110-2.5to2.5Pass -203.8510.0410.0122-2.5to2.5Pass -103.8510.2350.0124-2.5to2.5Pass 03.857.7160.0094-2.5to2.5Pass 103.8513.1400.0159-2.5to2.5Pass 303.857.5230.0091-2.5to2.5Pass 403.8512.4620.0151-2.5to2.5Pass 503.8510.0410.0122-2.5to2.5Pass 836.6 20 3.277.6190.0091-2.5to2.5Pass 3.8512.5270.0150-2.5to2.5Pass 4.439.5570.0114-2.5to2.5Pass -303.856.3600.0076-2.5to2.5Pass -203.852.8410.0034-2.5to2.5Pass -103.853.5840.0043-2.5to2.5Pass 03.857.8450.0094-2.5to2.5Pass 103.857.8780.0094-2.5to2.5Pass 303.856.3600.0076-2.5to2.5Pass 403.859.1050.0109-2.5to2.5Pass 503.858.5230.0102-2.5to2.5Pass 848.8 20 3.274.8430.0057-2.5to2.5Pass 3.856.8770.0081-2.5to2.5Pass 4.4310.5900.0125-2.5to2.5Pass -303.856.1670.0073-2.5to2.5Pass -203.855.4240.0064-2.5to2.5Pass -103.857.4900.0088-2.5to2.5Pass 03.854.1650.0049-2.5to2.5Pass 103.856.0050.0071-2.5to2.5Pass 303.851.2270.0014-2.5to2.5Pass 403.853.2930.0039-2.5to2.5Pass 503.850.6460.0008-2.5to2.5Pass 3.ModulationCharacteristics 3.1TestResult 3.1.1GSM850 Band:GSM850 ENV Mode Frequency (MHz) ModulationCharacteristics Verdict NetworkSubsetResultLimit NTNV GSMGSM836.6ReferToTestGraphPass GPRS1TXSlot836.6ReferToTestGraphPass EGPRS1TXSlot836.6ReferToTestGraphPass 3.2TestGraph 3.2.1GSM850 GSM850_GSM_MCH_836.6MHz_GSM_NTNV GSM850_GPRS_MCH_836.6MHz_1TXSlot_NTNV GSM850_EGPRS_MCH_836.6MHz_1TXSlot_NTNV 4.99%&26dBBandwidth 4.1TestResult 4.1.1GSM850_OBW Band:GSM850 ENV Mode Frequency (MHz) 99%OccupiedBandwidth(MHz) Verdict NetworkSubsetResultLimit NTNV GSMGSM 824.20.243/Pass 836.60.244/Pass 848.80.241/Pass GPRS1TXSlot 824.20.243/Pass 836.60.247/Pass 848.80.242/Pass EGPRS1TXSlot 824.20.244/Pass 836.60.248/Pass 848.80.229/Pass 4.1.2GSM850_XDB Band:GSM850 ENV Mode Frequency (MHz) 26dBBandwidth(MHz) Verdict NetworkSubsetResultLimit NTNV GSMGSM 824.20.310/Pass 836.60.312/Pass 848.80.300/Pass GPRS1TXSlot 824.20.317/Pass 836.60.319/Pass 848.80.304/Pass EGPRS1TXSlot 824.20.312/Pass 836.60.293/Pass 848.80.288/Pass 4.2TestGraph 4.2.1GSM850_OBW GSM850_GSM_LCH_824.2MHz_GSM_NTNV GSM850_GSM_MCH_836.6MHz_GSM_NTNV GSM850_GSM_HCH_848.8MHz_GSM_NTNV GSM850_GPRS_LCH_824.2MHz_1TXSlot_NTNV GSM850_GPRS_MCH_836.6MHz_1TXSlot_NTNV GSM850_GPRS_HCH_848.8MHz_1TXSlot_NTNV GSM850_EGPRS_LCH_824.2MHz_1TXSlot_NTNV GSM850_EGPRS_MCH_836.6MHz_1TXSlot_NTNV GSM850_EGPRS_HCH_848.8MHz_1TXSlot_N…

Text truncated - open the document above for the full version.

Test Report

1.Effective(Isotropic)RadiatedPowerOutputData 1.1TestResult 1.1.1PCS1900_EIRP Band:PCS1900 ENV Mode Frequency (MHz) ConductedPower (dBm) Gain (dBi) EIRP(dBm) Verdict NetworkSubsetResultLimit NTNV GSMGSM 1850.228.53-0.9427.59<=33.01Pass 188028.16-0.9427.22<=33.01Pass 1909.827.79-0.9426.85<=33.01Pass GPRS 1TXSlot1850.228.47-0.9427.53<=33.01Pass 2TXSlots1850.225.71-0.9424.77<=33.01Pass 3TXSlots1850.224.09-0.9423.15<=33.01Pass 4TXSlots1850.222.09-0.9421.15<=33.01Pass 1TXSlot188028.12-0.9427.18<=33.01Pass 2TXSlots188025.21-0.9424.27<=33.01Pass 3TXSlots188023.60-0.9422.66<=33.01Pass 4TXSlots188021.56-0.9420.62<=33.01Pass 1TXSlot1909.827.80-0.9426.86<=33.01Pass 2TXSlots1909.824.70-0.9423.76<=33.01Pass 3TXSlots1909.823.07-0.9422.13<=33.01Pass 4TXSlots1909.821.08-0.9420.14<=33.01Pass EGPRS 1TXSlot1850.226.25-0.9425.31<=33.01Pass 2TXSlots1850.225.89-0.9424.95<=33.01Pass 3TXSlots1850.224.28-0.9423.34<=33.01Pass 4TXSlots1850.221.27-0.9420.33<=33.01Pass 1TXSlot188026.15-0.9425.21<=33.01Pass 2TXSlots188026.27-0.9425.33<=33.01Pass 3TXSlots188024.21-0.9423.27<=33.01Pass 4TXSlots188021.83-0.9420.89<=33.01Pass 1TXSlot1909.825.70-0.9424.76<=33.01Pass 2TXSlots1909.825.49-0.9424.55<=33.01Pass 3TXSlots1909.823.56-0.9422.62<=33.01Pass 4TXSlots1909.821.03-0.9420.09<=33.01Pass Note1:EIRP=ConductedPower+AntennaGain 2.FrequencyStability 2.1TestResult 2.1.1PCS1900 Band:PCS1900 Network Frequency (MHz) Temp. (°C) Voltage (VDC) Freq.Error (Hz) Freq.vs.Rated(ppm) Verdict ResultLimit GSM1850.2 20 3.271.2270.0007-2.5to2.5Pass 3.859.0080.0049-2.5to2.5Pass 4.43-5.069-0.0027-2.5to2.5Pass -303.85-7.458-0.0040-2.5to2.5Pass -203.85-5.682-0.0031-2.5to2.5Pass -103.85-6.780-0.0037-2.5to2.5Pass 03.855.1010.0028-2.5to2.5Pass 103.85-12.850-0.0069-2.5to2.5Pass 303.85-11.365-0.0061-2.5to2.5Pass 403.85-2.454-0.0013-2.5to2.5Pass 503.85-23.278-0.0126-2.5to2.5Pass 1880 20 3.27-15.626-0.0083-2.5to2.5Pass 3.85-1.485-0.0008-2.5to2.5Pass 4.43-3.842-0.0020-2.5to2.5Pass -303.853.9070.0021-2.5to2.5Pass -203.85-5.101-0.0027-2.5to2.5Pass -103.85-8.330-0.0044-2.5to2.5Pass 03.856.4570.0034-2.5to2.5Pass 103.85-14.464-0.0077-2.5to2.5Pass 303.853.0030.0016-2.5to2.5Pass 403.8510.8160.0058-2.5to2.5Pass 503.85-4.617-0.0025-2.5to2.5Pass 1909.8 20 3.27-15.433-0.0081-2.5to2.5Pass 3.85-8.975-0.0047-2.5to2.5Pass 4.434.5200.0024-2.5to2.5Pass -303.85-0.420-0.0002-2.5to2.5Pass -203.85-8.007-0.0042-2.5to2.5Pass -103.854.1970.0022-2.5to2.5Pass 03.8513.4950.0071-2.5to2.5Pass 103.85-10.783-0.0056-2.5to2.5Pass 303.85-2.938-0.0015-2.5to2.5Pass 403.85-2.131-0.0011-2.5to2.5Pass 503.852.3570.0012-2.5to2.5Pass GPRS 1850.2 20 3.277.4580.0040-2.5to2.5Pass 3.85-0.420-0.0002-2.5to2.5Pass 4.43-2.195-0.0012-2.5to2.5Pass -303.859.6210.0052-2.5to2.5Pass -203.85-1.873-0.0010-2.5to2.5Pass -103.859.6860.0052-2.5to2.5Pass 03.8515.3030.0083-2.5to2.5Pass 103.857.3290.0040-2.5to2.5Pass 303.854.1650.0023-2.5to2.5Pass 403.85-0.194-0.0001-2.5to2.5Pass 503.8511.0420.0060-2.5to2.5Pass 1880 20 3.2720.5660.0109-2.5to2.5Pass 3.8511.4610.0061-2.5to2.5Pass 4.4319.4360.0103-2.5to2.5Pass -303.8519.1780.0102-2.5to2.5Pass -203.853.0990.0016-2.5to2.5Pass -103.8519.0160.0101-2.5to2.5Pass 03.8513.7210.0073-2.5to2.5Pass 103.858.5880.0046-2.5to2.5Pass 303.856.9410.0037-2.5to2.5Pass 403.859.9760.0053-2.5to2.5Pass 503.85-1.485-0.0008-2.5to2.5Pass 1909.8 20 3.2718.0800.0095-2.5to2.5Pass 3.8517.5310.0092-2.5to2.5Pass 4.4311.0740.0058-2.5to2.5Pass -303.8515.1100.0079-2.5to2.5Pass -203.8524.3440.0127-2.5to2.5Pass -103.8515.8200.0083-2.5to2.5Pass 03.8521.0180.0110-2.5to2.5Pass 103.85-6.360-0.0033-2.5to2.5Pass 303.854.1000.0021-2.5to2.5Pass 403.8519.0160.0100-2.5to2.5Pass 503.8512.9790.0068-2.5to2.5Pass EGPRS1850.2203.2714.6580.0079-2.5to2.5Pass 3.8524.9250.0135-2.5to2.5Pass 4.438.7490.0047-2.5to2.5Pass -303.857.2000.0039-2.5to2.5Pass -203.85-1.195-0.0006-2.5to2.5Pass -103.858.6200.0047-2.5to2.5Pass 03.851.0650.0006-2.5to2.5Pass 103.854.8430.0026-2.5to2.5Pass 303.8511.9130.0064-2.5to2.5Pass 403.851.8400.0010-2.5to2.5Pass 503.852.1310.0012-2.5to2.5Pass 1880 20 3.277.9100.0042-2.5to2.5Pass 3.851.6470.0009-2.5to2.5Pass 4.436.7800.0036-2.5to2.5Pass -303.8518.8230.0100-2.5to2.5Pass -203.8515.0450.0080-2.5to2.5Pass -103.8517.1760.0091-2.5to2.5Pass 03.8517.7250.0094-2.5to2.5Pass 103.8511.5910.0062-2.5to2.5Pass 303.8513.3020.0071-2.5to2.5Pass 403.854.0360.0021-2.5to2.5Pass 503.851.8730.0010-2.5to2.5Pass 1909.8 20 3.279.2980.0049-2.5to2.5Pass 3.8527.1520.0142-2.5to2.5Pass 4.43-3.293-0.0017-2.5to2.5Pass -303.857.5550.0040-2.5to2.5Pass -203.8512.7850.0067-2.5to2.5Pass -103.8515.3680.0080-2.5to2.5Pass 03.8512.1070.0063-2.5to2.5Pass 103.8515.5620.0081-2.5to2.5Pass 303.856.5540.0034-2.5to2.5Pass 403.855.0690.0027-2.5to2.5Pass 503.8513.4950.0071-2.5to2.5Pass 3.ModulationCharacteristics 3.1TestResult 3.1.1PCS1900 Band:PCS1900 ENV Mode Frequency (MHz) ModulationCharacteristics Verdict NetworkSubsetResultLimit NTNV GSMGSM1880ReferToTestGraphPass GPRS1TXSlot1880ReferToTestGraphPass EGPRS1TXSlot1880ReferToTestGraphPass 3.2TestGraph 3.2.1PCS1900 PCS1900_GSM_MCH_1880MHz_GSM_NTNV PCS1900_GPRS_MCH_1880MHz_1TXSlot_NTNV PCS1900_EGPRS_MCH_1880MHz_1TXSlot_NTNV 4.99%&26dBBandwidth 4.1TestResult 4.1.1PCS1900_OBW Band:PCS1900 ENV Mode Frequency (MHz) 99%OccupiedBandwidth(MHz) Verdict Network…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Paul Greene(CEO)
[email protected]001-3014124412Fax: 001-3014124412

Technical Contact

Xwireless LLC
[email protected]

United States

Test Firm

Shenzhen PSI Testing Co., Ltd.Simple Guan
[email protected]+86 0755-23019820

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
3927670.5 MHz - 690.5 MHz36.90 mW13M7W7D0.0722 ppm
Confidentiality
Long Term
Grant Notes
Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, product specific (wireless router), and simultaneous transmission use conditions is 0.36W/kg, 1.39W/kg, 1.39W/kg and 1.50W/kg respectively. This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations.

Other Applications from Xwireless LLC

2ADLJ-PG65

Mobile Phone

Jun 27, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2ADLJ-ZG55

Mobile Phone

Apr 15, 2024

Equipment Class

DTS - Digital Transmission System
Smartphone - FCC ID 2ADLJ-HD68 - Xwireless LLC
2ADLJ-HD68

Smartphone

Feb 20, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Mobile Phone - FCC ID 2ADLJ-HD67 - Xwireless LLC
2ADLJ-HD67

Mobile Phone

Feb 04, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Smartphone - FCC ID 2ADLJ-HD65CHOICE - Xwireless LLC
2ADLJ-HD65CHOICE

Smartphone

Dec 03, 2023

Equipment Class

PCE - PCS Licensed Transmitter held to ear