FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Zeeva International Limited/
  3. 2ADM5-EP-0619

2ADM5-EP-0619BT TWS METER EARBUDS AST

Zeeva International Limited
BT TWS METER EARBUDS AST - FCC ID 2ADM5-EP-0619 - Zeeva International Limited
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Aug 23, 2020
Application Purpose
Original Equipment
Date of Application
Aug 23, 2020
Equipment Note
BT TWS METER EARBUDS AST
Frequency Range
2402.00000000 - 2480.00000000
Company
Zeeva International Limited
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Block Diagram

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

Schematics

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Thank you for purchasing the Meter True Wireless Earbuds. This manual provides more information about the wireless earbuds, please read the instructions before using. INSTRUCTION MANUAL Pair the wireless earbuds with your mobile device 1. Keep the distance between the earbuds and mobile device within 32.8 feet. 2. De-activate the Bluetooth function on your mobile device. 3. Power on both earbuds simultaneously by pressing the On/Off buttons for 3 seconds and wait for 3 to 5 seconds for auto pairing. The Left earbud has indicator blinking alternatively in Red and Blue. The Right earbud will be blinking in Blue slowly when auto pairing is done successfully on L/R earbuds.. 4. Activate the Bluetooth function on your mobile device and select “METER TWS” from the list shown. 5. After pairing is successful, both earbuds will start blinking slowly in blue. *Attention: If the auto pairing is not successful, manual pairing between earbuds is essential by following below procedures: 1. Make sure the earbuds are charged. 2. De-activate the Bluetooth function on your mobile device. (if you had been paired the earbuds to some other mobile device(s) nearby, please sure to de-activate those device(s) too). 3. Power on both earbuds simultaneously by pressing the On/Off buttons for 3 seconds and wait for 3 to 5 seconds for auto pairing. (Keep the Bluetooth function off on your mobile device before this operation.) 4. Activate the Bluetooth function on your mobile device and select “METER TWS” from the list shown. 5. After pairing successfully, both earbuds will start blinking slowly in blue. Reconnect the wireless earbuds to your mobile device Disconnect the wireless earbuds from your mobile device Power off the wireless earbuds; or Switch off the Bluetooth on your mobile phone; or Leave the earbuds 60ft away from your mobile phone or further. Answer / Reject a call When receive a call, press the On/Off Button once ( on either earbud) to accept the call, or answer the call normally via your moblie phone. Press and hold 2 seconds to reject it. End a call To end the call, just press On/Off button at any side of earbud with Beep sound to end it. Functions Pause / Play Music: Short Press on On/OFF Button Go back to previous song: Press Left On/Off Button for 1 second. Advance to next song: Press Right On/Off Button for 1 second. Volume up: Double click Right On/Off button to increase Volume down: Double click Left On/Off to reduce Recharge Charging Case 1. Open the charging case cover. 2. Insert the Dual Earbuds into the charging case. 3. The earbuds will start the charge automatically. 4. LED indicator light of the charging case will be turned to Blue when charging your earbuds. 5. Once fully charged, the LED will be off. Charging your Earbuds If the wireless earbuds cannot be paired with your device, please try the following: Ensure that your earbuds are in pairing mode or reconnection mode Ensure that Bluetooth search function of your mobile device is activated. If the wireless earbuds will not turn on: Make sure the earbuds are fully charged. Can I change the battery for the earbuds? The wireless earbuds use a built-in non-detachable battery which cannot be removed. If the wireless earbuds cannot be recharged: If you use a power outlet, ensure that the power supply is connected securely and the outlet works. If you use a computer, ensure that it is connected and the USB port is powered. FAQ Product OverviewPower On/Off Package Contents -The input voltage to the product is 5V 1A. -In order to charge the product in safe manner and reliable conditions, please only adopt certified appropriate charger/ adapter for charging the product. -Only charge the product at ambient temperatures between 10 deg °C/ 50 deg °F and 40 deg °C/104 deg °F. - Do not heat above 70 deg °C/158 deg °F, eg. Do not expose to sunlight or throw into fire. -Switch off the product after use. -Please note that we won’t take any responsibility for any wrong operation (eg. Voltage higher than 5V) as this may result in severe injury or loss of property, and we cannot control the operating process during the time the user using this product. -In extreme cases, abuse or misuse of Lithium battery pack can lead to explosion, heat generation, fire development or smoke development. Safety instructions for the lithium battery and charging the product 3 4 5 1. On/Off Button/ Play/Pause Music Answer/End Call 2. LED Indicator 3. On/Off Button 4. Battery Level LED Display 5. Micro USB Charging Port USB PlugMicro USB Plug Meter True Wireless Earbuds x 1 pair Portable Charging Case x 1 Power On Press and hold down the On/Off Button of earbuds for 3 seconds and the LED will flash. Power Off Press and hold down the On/Off Button of earbuds for 4 seconds and the LED will turn off. When powered on, the wireless earbuds will automatically connect with the last successfully paired device. Specifications Driver Diameter: 8 mm Impedance: 32 Ohms Frequency Response: 20 Hz – 20 KHz Sensitivity: 96 dB +/- 3 dB Power Supply: Li-ion Battery 3.7V 35 mAh (per Earbud) Li-ion Battery 3.7V 500 mAh (Charging Case) Play Time: Total 10 Hours (Earbuds playing time is 2 Hours and the Charging Case can provide 6 times for the earbuds charging) Charging Time: 2-2.5 Hours Bluetooth Range: 32.8 Feet Micro USB cable included Charging Case with Battery Level LED Display Instruction Manual Micro USB Charging Cable Instruction Manual FCC STATEMENT 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. 2. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 o…

Text truncated - open the document above for the full version.

Attestation Statements

Zeeva International Limited Suite 1007B, 10th Floor, Exchange Tower, 33 Wang Chiu Road,Kowloon Bay, Hong Kong Tel: +852-2868 0511 | Fax: +852-2524 1986 E-mail: [email protected] Date: 08/13/2020 To: FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 We, Zeeva International Limited hereby declare that: Product Name: BT TWS METER EARBUDS AST Model No: EP-0619 FCC ID: 2ADM5-EP-0619 For BT Mode: BLE are disable by software For Below are activated: Bluetooth BDR(GFSK) , EDR(π/4‐DQPSK), EDR(8DPSK) Except for the manufacturer, the end user does not have any capability to modify/change the RF parameters. We acknowledge that it is the manufacturer’s responsibility to provide the radio configurations to ensure compliance with Commission’s rules. Sincerely Yours, Signature: Printed Name: Akshay P Butani Tiltle: Vice President

Block Diagram

BlockDiagram SPEAKER DAC OSCILLATOR FLASH ANT XTAL 24M AC6969 2402-2480MHz

Cover Letter(s)

202 FE D Aut 743 Col u Su b To w We , Com app to t h our We , that 21 U Thi s Sin c Sig n Prin Titl QA-F 20/08/13 DERAL CO thorization a 5 Oakland M umbia, MD bject: Agent whom it ma , Zeeva Inte mpliance La lication for hese matters behalf shal , the unders t includes FC U.S.C. 862. s authorizat cerely Your nature: nted Name: e: Vice P r FR-170-B OMMUNICA and Evaluat Mills Road D 21046 t Authorizat ay concern: ernational L aboratories Equipmen t s. All acts c l have the s signed, here CC benefits tion is valid rs, Akshay P B resident FCC ATIONS C tion Divisio tion Limited the u Corporation t authorizati carried out b same effect eby certify th s, pursuant t d until furthe Butani Zeeva Int Suite 100 Road, Ko Tel: +852 E-mail: a C Author COMMISSIO on undersigned n to act on i ion, includin by Bay Area as our own hat we are n to Section 5 er written n ternational Lim 07B, 10th Floo owloon Bay, H 2-2868 0511 | akshay.butan rization ONS d, hereby au its behalf in ng the signi a Complian action. not subject t 5301 of the otice from t mited or, Exchange T Hong Kong Fax: +852-2 5 [email protected] uthorize Bay n all matters ing of all do nce Laborato to a denial o Anti-Drug the applican Tower, 33 Wa 524 1986 com y Area relating to ocuments re ory Corpora of federal b Abuse Act nt. ang Chiu elating ation on enefits, of 1988,

Cover Letter(s)

We BT wa tha inf con Si nc Si gn Prin Titl e, Zeeva Int TWS MET as tested by at the produ formation ab ntact me if cerely Your nature: nted Name: e : Vice Pr ternational L TER EARBU BACL ,wh uct has two u bove is true you have an rs, Ak shay P B resident Limited her UDS AST hich has left units which e, and we’ll ny question Butani Zeeva Int Suite 100 Road, Ko Tel: +852 E-mail: a reby declare (FCC ID:2A t earbud and h are electric be responsi n. ternational Lim 07B, 10th Floo owloon Bay, H 2-2868 0511 | akshay.butan Declaration e that we ha ADM5-EP- d right earbu cally identic ible for all t mited or, Exchange T Hong Kong Fax: +852-2 5 [email protected] ave a produc -0619 ; Mod ud. we wou cal.We conf the consequ Tower, 33 Wa 524 1986 com ct named as del: EP-061 ld like to de firm that all uences. Plea ang Chiu s 9 ) eclare l ase

Cover Letter(s)

Zeeva International Limited Suite 1007B, 10th Floor, Exchange Tower, 33 Wang Chiu Road, Kowloon Bay, Hong Kong Tel: +852-2868 0511 | Fax: +852-2524 1986 E-mail: [email protected] FCC ID Cover Letter The Zeeva International Limited here by submits justification for placing the FCC ID in the Associated User Manual. According to the FCC Regulation and Guidance (KDB Publication 784748 D01 v09r01) allows for the FCC ID to be moved to the User’s manual if the device is unquestionably too small for the FCC ID to be printed. Referring to the above quote, as the device is too small (FCC ID:2ADM5-EP-0619 ) to be printed. The FCC ID will be moved to the last page of user’s manual and charging case. The details are as below: A. Side surface (A): The curvature shape of the silicone sleeve back cover is not flat, so it’s hard to affix thelabel on the surface of the earbuds. B. Top cover (B): The plastic logo of the top cover does not provide enough physical space to fit the printing of the FCC ID according to below reference picture. Conclusion: Based on the above description of area A to B, we conclude that the device is unquestionably too samll for enabling the FCC ID to be printed onto any surface, We therefore request to move the FCC ID to the User manual and charging case Sincerely Yours, Signature: Printed Name: Akshay P Butani Title: Vice President

External Photos

Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ200715832-RF Page 1 of 8 EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ200715832-RF Page 2 of 8 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ200715832-RF Page 3 of 8 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ200715832-RF Page 4 of 8 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ200715832-RF Page 5 of 8 Charging Box and Cable Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ200715832-RF Page 6 of 8 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ200715832-RF Page 7 of 8 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ200715832-RF Page 8 of 8

ID Label/Location Info

Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ200715832-RF EXHIBIT A - FCC ID LABEL AND LOCATION FCC ID Label FCC ID Label Location Information The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase (Labeling requirements per 2.925)

Internal Photos

Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ200715832-RF Page 1 of 6 EXHIBIT C - EUT INTERNAL PHOTOGRAPHS Left Earbud Antenna Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ200715832-RF Page 2 of 6 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ200715832-RF Page 3 of 6 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ200715832-RF Page 4 of 6 Right Earbud Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ200715832-RF Page 5 of 6 Antenna Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ200715832-RF Page 6 of 6

Operational Description

Circuit Description The 24MHZ crystal oscillator drives the base of Y1. The modulation provided by AC6969(U1). The output of AC6969 module (U1)has the matching network consisting that limit the harmonic content and effect the proper coupling of the antenna to the output stage. Antenna, Ground and Power Source The antenna consists of a 2.4GHz PCBantenna There is no external ground connection. The ground is only that of the printed circuit board. Electric current is supplied by a 3.7 Volt primary battery Feature: Frequency Range: 2402MHz-2480MHz Modulation Type: GFSK, π /4-DQPSK, 8DPSK Antenna Type: PCBA ntenna Crystal: 24MHz

Schematics

AC6969 MCU PowerKEY、LED C3222/16V AGND BT_OSCO BT_OSCI +3.3V VBAT GND C1105 C2NC/10V C8 2.7P BT_ANT L1 NC L2 NC BT_RF BT_ANT DC5V D1 BLUE D2 RED VDDIO 1 VBAT 2 PB1/ADC5 6 DACVSS 15 ADC1/MIC/PA1 16 ADC14/USBDM 11 MIC_BIAS/PA2/PA3/USBDP 12 BT_OSCI 9 BT_OSCO 10 BT_RF 7 VSSIO 8 PB3/ADC6 5 DACL 14 LDO_IN/PB5 3 BT_AVDD 4 DACR 13 U1 S2 PREV/V+ S3 NEXT/V- S1 P/P/POWER/TALK P/P/POWER BT_OSCOBT_OSCI Y124M J1 Earphone DACL DACR BAT 3.4V~4.2V VBAT DC5V +5V 1 DM 2 DP 3 ID 4 6 GND 6 6 66 J2 USB(MICRO) DACL DACR MIC P/P/POWER S1 P/P/POWER/TALK P/P/POWER KEY0 LED_B/R KEY0 C4105 BT_AVDD +3.3V LED_B/R R1 2.7R +5V (0603封装) + M1 MIC4013 C6 NC MIC P/P/POWERKEY0 T1VBAT T2DM T3DP T4GND T5VDDIO VBAT +3.3V USBDP USBDM GND Earphone、MIC USBDP USBDM

Test Report

Note: This report must not be used by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of the Federal Government. This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “★”. BACL is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with an asterisk ’*’. Customer model name, addresses, names, trademarks etc. are not considered data. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. FCC PART 15.247 TEST REPORT For Zeeva International Limited Suite 1007B, 10th Floor, Exchange Tower, 33 Wang Chiu Road, Kowloon Bay, Hong Kong, China FCC ID: 2ADM5-EP-0619 Report Type: Original Report Product Type: BT TWS METER EARBUDS AST Re port Number: RSZ200715832-00 Re port Date: 2020-08-07 Reviewed B y: Jimmy Xiao RF Engineer Prepared By: Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road, Futian Free Trade Zone, Shenzhen, Guangdong, China Tel: +86-755-33320018 Fax: +86-755-33320008 www.baclcorp.com.cn Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200715832-00 FCC Part 15.247 Page 2 of 53 TABLE OF CONTENTS GENERAL INFORMATION ....................................................................................................................................... 4 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 4 OBJECTIVE ................................................................................................................................................................... 4 RELATED SUBMITTAL(S)/GRANT(S) ............................................................................................................................. 4 TEST METHODOLOGY .................................................................................................................................................. 4 MEASUREMENT UNCERTAINTY .................................................................................................................................... 5 TEST FACILITY ............................................................................................................................................................. 5 SYSTEM TEST CONFIGURATION .......................................................................................................................... 6 DESCRIPTION OF TEST CONFIGURATION ...................................................................................................................... 6 EUT EXERCISE SOFTWARE .......................................................................................................................................... 6 SPECIAL ACCESSORIES ................................................................................................................................................. 6 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 6 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................... 6 EXTERNAL I/O CABLE .................................................................................................................................................. 6 BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................ 6 SUMMARY OF TEST RESULTS ............................................................................................................................... 7 TEST EQUIPMENT LIST ........................................................................................................................................... 8 FCC§15.247 (i), §1.1307 (b) (1) &§2.1093 – RF EXPOSURE ........................................................................................ 9 APPLICABLE STANDARD .............................................................................................................................................. 9 FCC §15.203 – ANTENNA REQUIREMENT .......................................................................................................... 10 APPLICABLE STANDARD ............................................................................................................................................ 10 ANTENNA CONNECTOR CONSTRUCTION .................................................................................................................... 10 FCC §15.207 (a) – AC LINE CONDUCTED EMISSIONS ..................................................................................... 11 APPLICABLE STANDARD ............................................................................................................................................ 11 EUT SETUP ................................................................................................................................................................ 11 EMI TEST RECEIVER SETUP ....................................................................................................................................... 11 TEST PROCEDURE ...................................................................................................................................................... 11 CORRECTED FACTOR & MARGIN CALCULATION .............................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ200715832-RF Page 1 of 2 EXHIBIT D - TEST SETUP PHOTOGRAPHS Conducted Emissions - Front View Conducted Emissions - Side View Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: RSZ200715832-RF Page 2 of 2 Radiated Emissions View (Below 1 GHz) Radiated Emissions View (Above 1 GHz)

Contact Information

Applicant

Kevin Tso(Engineering & Compliance Manager)
[email protected]852-2868 0511Fax: 852-2524 1986

Test Firm

Bay Area Compliance Laboratories Corp. (Shenzhen)Well Wang
[email protected]+86 (0) 755 33320018

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz700.00 µW
Grant Notes
Output power listed is conducted.

Other Applications from Zeeva International Limited

2ADM5-HP-0022

DJ STYLE BT HP F26

Aug 27, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
DISNEY MICKEY DOME SPKR - FCC ID 2ADM5-SP-0774 - Zeeva Int Limited
2ADM5-SP-0774

DISNEY MICKEY DOME SPKR

Jul 15, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
RC STUNT CAR F26 - FCC ID 2ADM5-ET-0973-27 - Zeeva Int Limited
2ADM5-ET-0973-27

RC STUNT CAR F26

Jun 04, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
LANAS LIFE VGA MOUSE - FCC ID 2ADM5-GA-0541 - Zeeva Int Limited
2ADM5-GA-0541

LANAS LIFE VGA MOUSE

Apr 16, 2026

Equipment Class

DTS - Digital Transmission System
TRANSLATION OWS - FCC ID 2ADM5-EP-0739 - Zeeva Int Limited
2ADM5-EP-0739

TRANSLATION OWS

Jan 04, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter