FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. CLIQ LIMITED/
  3. 2ADODJ222324R

2ADODJ222324RMassage Device & Remote

CLIQ LIMITED
Massage Device & Remote - FCC ID 2ADODJ222324R - CLIQ LIMITED
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Sep 02, 2023
Application Purpose
Original Equipment
Date of Application
Sep 02, 2023
Equipment Note
Massage Device & Remote
Frequency Range
2402.00000000 - 2480.00000000
Company
CLIQ LIMITED
Country
United Kingdom

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

BUTT PLUGS Lubrication: We r ecommend usin g onl y water-based lu bricants wit h our toys. For cleaning: We r ecommend washing your toy wit h war m water and soa p. Je Joue has designed three butt plugs, each varying in size, shape and weight. Designed with pure pleasure in mind, these body-safe vibrating butt plugs is the luxury your butt deserves. The powerfully low-frequency rumbling vibrations will penetrate your pleasure spots from deep within. With the sizes varying, there is truly something for everyone interested in unlocking the joys of anal play. • To turn the toy on, hold the + button until the red light shows and it begins vibrating • To increase the vibration speed, use the + button • To decrease the vibration speed use the - button • To try out the various vibrations patterns, use the ~ middle button • To turn the toy off hold the - button until the red light goes off and the toy stops vibrating. • Remote control is bluetooth technology and will connect to the butt plug once turned on. • To use the travel lock please hold down the + and - for approx 5 seconds when in off mode. To unlock do the same. • Remote control is not waterproof • Once you have finished using your toy we recommend cleaning it with warm water and soap. • After your toy has dried, store in a cool, dry place • For all Je Joue products, use only water based lubricants • Remember to keep your toy charged. It takes 1.5hrs to charge which allows 1 hour of play on the highest setting. Instructions: Je Joue warrants your toy for a period of one year from the date of original purchase against any defects due to faulty materials or workmanship. If the product fails during the warranty period, Je Joue will repair or replace it free of charge. To obtain service under this warranty, return the defective product to the retailer from whom you purchased your toy, together with your sales receipt, address, and a daytime phone number. This warranty does not cover defects caused by accidental damage, misuse or other use not in accordance with this instructional manual and its safety warnings. Removing the battery from your toy or otherwise dismantling or tampering with your toy invalidates the warranty and may prevent your toy from being repaired. of non-defective products after the seal on the packaging has been broken. This warranty does not affect your statutory rights as a consumer in any way. Limited Warranty: Je Joue suppo rts your toy pur chased in the UK. If your toy was pur chased from els ewhere t hen Je Jo ue may attempt a repair but cannot guar an tee the outco me. Safety Information - IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USE. DO NOT DISCARD THESE INSTRUCTIONS. WARNING! WHEN USING ELECTRICAL PRODUCTS BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED. danger ous electric shock or injury: 1. DO NOT place or s tore your toy or t he char ger in an y liqui d (other t han water in accordan ce wit h t hese ins tr ucti ons). 2. DO NOT use your toy whilst it is char ging. 3. DO NOT char ge your toy whilst it is in, or n ear to, water or any other li qui d. 4. DO NOT use a power adapter other t han the char ger in clu ded wit h your toy or pur chased from Je Joue. If you need a replace ment part, plea se contact u s. 5. DO NOT plu g the char ger into an inco rrec t v olt age wall plu g labe l. 6. DO NOT use wit h volt age convert ers and plu g adapters. 7. DO NOT f orce the char ger plu g into an elec tr ical outl et. 8. DO NOT use t he char ger if the char ger or its wir e is damaged in any way. 9. DO NOT attach your toy to t he char ger when wet o r when your han ds are wet. 10. ALWAYS unplu g your toy from the char ger before cleaning (in accordan ce wit h t hese instr ucti ons). 11. ALWAYS ensure t hat y our toy is dry before conn ec tin g it t o t he char ger and plu gging the char ger into an elec tr ical outl et. 12 . ALWAYS conn ec t t he char ger t o a prope rly groun ded elec tr ical outl et. 13 . DO NOT char ge your toy outdoors. Je Joue Toys 14. DO NOT ope rate or c har ge your toy where aerosol administered . 15 . Whilst y our toy is water r esis tan t and is capa ble of saf e use both in the bath or shower, it shoul d not be su bmerged for prolonged periods of time and shoul d be dr ied completely after such use. (h ot o r cold) . danger ous electric shock or injury: 1. Use your toy onl y in accordan ce wit h t hese instr ucti on man uals. 2. DO NOT use your toy wit h accessories that are not recommended by Je Joue. 3. DO NOT attempt t o disman tl e or otherwis e t ampe r wit h your toy, its char ger or any of its compo nents . Doin g so may r esult in injur y and invali date your war ran ty. 4. DO NOT use t he char ger if the main cord or power supply is damaged , or if your toy is not f un cti oning prope rly. 5. NEVER ope rate your toy if it or any of its compo nents have been dropped, damaged , or are not working in any way (if you enco un ter any problems , plea se contact u s and 6. DO NOT dispo se of your toy or any of its compo nents 7. Kee p your toy and the char ger cord away f rom hea ted surface s. the product. 9. DO NOT use t he adaptor/char ger suppli ed wit h your toy wit h any other equipment. 10. DO NOT use other adaptors/char gers other t han those su ppli ed wit h your toy. 11. The char gers may become hot durin g use – tak e care when han dling, allow hea t t o dispe rse. 12 . Your toy may get h ot when char ging. DO NOT COVER. danger ous electric shock or injury during operation: 1. ALWAYS ope rate your toy in accordan ce wit h t hese ins tr ucti ons . 2. Your toy is not a chil toy. Plea se kee p away f rom chil dr en. 3. NEVER attempt t o remove t he f ascia. un damaged silico ne cover or f ascia. 5. DO NOT ope rate your toy if the outer l ayer of silico ne has been damaged . 6. DO NOT drop your toy. This coul d cause irreparable damage and may invali date t he war ran ty. 7. ALWAYS attach t he char ger t o your toy, then t o t he out- let. T o disco nn ec t, tur…

Text truncated - open the document above for the full version.

Attestation Statements

CLIO LIMITED U.S. Agent Designation for Service of Process (Applicant and U.S. Agent are Separate Parties) TO: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 ATTENTION: FCC Certification - Section 2.911(d)(7) Information D esiqnated U.S. Aqent Company Name: Unite d Consulting Technology Services Co., Ltd. FRN: 0033495714 Contact Name: David Wu Street Ad dress: 17800 CASTLETON ST STE 665 CITY OF INDUSTRY CA 91748 United States T elephone No: (626) 217-4022 Email: [email protected] Th is lette「 is to confi「m that we("the Designated U.S. Agent) have accepted the responsibility to act as the Designated U.S. Agent fo「 Service of Process as required by section 47 CFR 2.911 (d)(7) on behalf of the A pplicant noted below. U.S. Agent Signature: D ate: 2023/8/22 Si gned by (Printed NamefTitle): David Wu /CEO The Applicant acknowledges that th e y must maintain an agent for no less than one year after terminating all ma「keting and importation OR the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information above changes. Applicant Company name: CLIO LIMITED Grantee Code: 2ADOD FCC ID: 2ADODJ222324, 2ADODJ222324R Contact Name: Zhengyu Lin Street Address: 207 Record Hall, 16-16A Baldwin's Gardens City/Province/Zip: London, N/A, EC1 N ?RJ Telephone No: 4402078318707 Email: [email protected] A p p l i c a n t S i g n a t u r e : 功 纷 3 1 怀 伈 Date: 2023/8/22 Signed by (Printed Namemtle): Zhengyu Lin / Operation Manager

External Photos

SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.1 Page: 1 of 4 Appendix External Photos for GZCR2304000342HS Test Model No.: JJR1 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.1 Page: 2 of 4 EUT Constructional Details (EUT Photos) SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.1 Page: 3 of 4 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.1 Page: 4 of 4

Internal Photos

SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.1 Page: 1 of 2 Appendix Internal Photos for GZCR2304000342HS Test Model No.: JJR1 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.1 Page: 2 of 2 EUT Constructional Details (EUT Photos) Bluetooth ANT

RF Exposure Info

SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.1 Report No.: GZCR230400034207 Page: 1 of 9 FCC ID: 2ADODJ222324R Ricky Liu Manager RF EXPOSURE EVALUATION REPORT Application No.: GZCR2304000342HS Applicant:CliQ Limited Address of Applicant:207 Record Hall, 16-16A Baldwin's Gardens, London EC1N 7RJ Manufacturer:CliQ Limited Address of Manufacturer:207 Record Hall, 16-16A Baldwin's Gardens, London EC1N 7RJ Factory:CliQ Limited Address of Factory:207 Record Hall, 16-16A Baldwin's Gardens, London EC1N 7RJ Equipment Under Test (EUT): EUT Name:Massage Device & Remote Model No.: JJR1 Trade Mark:Je Joue Standard(s) : KDB447498D01 General RF Exposure Guidance v06 Date of Receipt: 2023-04-06 Date of Evaluation: 2023-04-24 Date of Issue: 2023-08-22 Evaluation Result: Pass* * In the configuration evaluated, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.1 Report No.: GZCR230400034207 Page: 2 of 9 Revision Record VersionReport No.DateRemark 01GZCR2304000342072023-08-22Original Authorized for issue by: Kevin Zhang/Project Engineer Vico Cui/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.1 Report No.: GZCR230400034207 Page: 3 of 9 2Evaluation Summary ItemStandardMethodRequirementResult RF Exposure KDB447498D01 General RF Exposure Guidance v06 KDB447498D01 General RF Exposure Guidance v06 KDB447498D01 General RF Exposure Guidance v06 Pass Note: E.U.T./EUT means Equipment Under Test. Pass means the test result passed the test standard requirement, please find the detailed decision rule in the report relative section. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.1 Report No.: GZCR230400034207 Page: 4 of 9 3Contents Page 1Cover Page...............................................................................................................................................1 2Evaluation Summary................................................................................................................................3 3Contents....................................................................................................................................................4 4General Information.................................................................................................................................5 4.1Details of E.U.T.................................................................................................................................5 4.2Evaluating Location...........................................................................................................................5 4.3Facility...............................................................................................................................................6 4.4Deviation from Standards..................................................................................................................6 4.5Abnormalities from Standard Conditions...........................................................................................6 5Technical Requirements Specification..................................................................................................7 5.1RF Exposure Evaluation....................................................................................................................7 5.1.1Limit & Test Method......................................................................................................................7 5.1.2Conclusion....................................................................................................................................7 6EUT Constructional Details (EUT Photos).............................................................................................9 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.1 Report No.: GZCR230400034207 Page: 5 of 9 4General Information 4.1Details of E.U.T. Power supply:DC 3V (CR2032 button cell) Cable(s):N/A For BLE Operation Frequency:2402MHz to 2480MHz Bluetooth Version:V5.1 dual mode Modulation Type:GFSK, pi/4DQPSK, 8DPSK Number of Channels:79 Channel Spacing:1MHz Spectrum Spread Technology: Frequency Hopping Spread Spectrum(FHSS) Antenna Type:Chip Antenna Antenna Gain:-0.68 dBi For BT Classic Operation Frequency:2402MHz to 2480MHz Bluetooth Version:V5.1 dual mode Modulation Type:GFSK Number of Channels:40 Channel Spacing:2MHz Antenna Type:Chip Antenna Antenna Gain:-0.68 dBi 4.2Evaluating Location All tests were performed at: SGS-CSTC Standards Technical Services Co., Ltd., Guangzhou Branch EMC Laboratory, 198 Kezhu Road, Scientech Park, Guangzhou Economic & Technology Development District, Guangzhou, China 510663 Tel: +86 20 82155555Fax: +86 20 82075059 No tests were sub-contracted. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.1 Report No.: GZCR230400034207 Page: 6 of 9 4.3Facility The facility is recognized, certified, or accredited by the following organizations: ● ACMA SGS-CSTC Standards Technical Services Co., Ltd., EMC Laboratory can also perform testing for the Australian/New Zealand Regulatory Compliance Mark (RCM). ● SGS UK(Certificate No.: 32), SGS-TUV SAARLAND and SGS-FIMKO Have approved SGS-CSTC Standards Technical Services Co., Ltd., EMC Laboratory as a supplier of EMC TESTING SERVICES and SAFETY TESTING SERVICES. ● FCC Recognized Accredited Test Firm(Registration No.: 486818) SGS-CSTC Standards Technical Services Co., Ltd., EMC Laboratory has been accredited and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. Designation Number: CN5016, Test Firm Registration Number: 486818. ● ISED (Registration No.: 4620B, CAB identifier: CN0052) SGS-CSTC Standards Technical Services Co., Ltd., has been registered by Innovation Sci…

Text truncated - open the document above for the full version.

Test Report

Inverted F Antenna Specification Summary ITEMANT SPEC Model Name 2.4G ANT HorizontalVertical 2400MHz 2441MHz 2500MHz2400MHz 2441MHz 2500MHz Center Frequency -1.73-0.84-0.68-6.15-3.70-2.32 MAX. Gain -0.68dBi PolarizationHorizontal and Vertical Azimuth Beam Pattern Omni-directional Impedance50 Ohm Antenna Length 38.20mm Manufacture ZHUHAI JIELI TECHNOLOGY CO.,LTD Antenna Photo & Length (mm) Address:No.333, Kexing Road, Xiangzhou, ZhuHai, Guangdong, China Horizontal: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -40 Scale: 5/div Gain (dB) Frequency (MHz) MaxMinAvg 2400-1.73178-30.0815-8.48713 2450-0.845801-38.5605-7.88012 2500-0.685586-24.0318-6.79139 Vertical: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -30 Scale: 5/div Gain (dB) Frequency (MHz) MaxMinAvg 2400-6.1530-24.1420-13.0295 2450-3.7054-26.5836-10.6700 2500-2.32122-30.4301-9.70536 ANT Test Labs:Attestation of Global Compliance Co., Ltd.

Test Report

SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-01 Rev 1.1 Report No.: GZCR230400034205 Page: 1 of 65 FCC ID: 2ADODJ222324R Ricky Liu Manager TEST REPORT Application No.: GZCR2304000342HS Applicant: CliQ Limited Address of Applicant: 207 Record Hall, 16-16A Baldwin's Gardens, London EC1N 7RJ Manufacturer: CliQ Limited Address of Manufacturer: 207 Record Hall, 16-16A Baldwin's Gardens, London EC1N 7RJ Factory: CliQ Limited Address of Factory: 207 Record Hall, 16-16A Baldwin's Gardens, London EC1N 7RJ Equipment Under Test (EUT): EUT Name: Massage Device & Remote Model No.: JJR1 Trade Mark: Je Joue Standard(s) : 47 CFR Part 15, Subpart C 15.247 Date of Receipt: 2023-04-06 Date of Test: 2023-04-17 to 2023-04-24 Date of Issue: 2023-08-22 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-01 Rev 1.1 Report No.: GZCR230400034205 Page: 2 of 65 Revision Record Version Report No. Date Remark 01 GZCR230400034205 2023-08-22 Original Aut horized for issue by: Kevin Zhang/Project Engineer Vico Cui/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-01 Rev 1.1 Report No.: GZCR230400034205 Page: 3 of 65 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C 15.247 N/A 47 CFR Part 15, Subpart C 15.203 & 15.247(b)(4) Pass Radio Spectrum Matter Part Item Standard Method Requirement Result Conducted Peak Output Power 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.9.1 47 CFR Part 15, Subpart C 15.247(b)(3) Pass Minimum 6dB Bandwidth ANSI C63.10 (2013) Section 11.8.1 47 CFR Part 15, Subpart C 15.247a(2) Pass Power Spectrum Density ANSI C63.10 (2013) Section 11.10.2 47 CFR Part 15, Subpart C 15.247(e) Pass Conducted Band Edges Measurement ANSI C63.10 (2013) Section 11.13.3.2 47 CFR Part 15, Subpart C 15.247(d) Pass Conducted Spurious Emissions ANSI C63.10 (2013) Section 11.11 47 CFR Part 15, Subpart C 15.247(d) Pass Radiated Emissions which fall in the restricted bands ANSI C63.10 (2013) Section 11.12 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Below 1GHz ANSI C63.10 (2013) Section 6.4,6.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Above 1GHz ANSI C63.10 (2013) Section 6.6 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Note: E.U.T./EUT means Equipment Under Test. Pass means the test result passed the test standard requirement, please find the detailed decision rule in the report relative section. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-01 Rev 1.1 Report No.: GZCR230400034205 Page: 4 of 65 3 Contents Page 1 Cover Page ......................................................................................................................................... 1 2 Test Summary ..................................................................................................................................... 3 3 Contents ............................................................................................................................................. 4 4 General Information............................................................................................................................ 6 4.1 Details of E.U.T. ........................................................................................................................... 6 4.2 Description of Support Units ......................................................................................................... 6 4.3 Measurement Uncertainty ............................................................................................................ 6 4.4 Test Location ............................................................................................................................... 6 4.5 Test Facility .................................................................................................................................. 7 4.6 Deviation from Standards ............................................................................................................. 7 4.7 Abnormalities from Standard Conditions ....................................................................................... 7 5 Equipment List ................................................................................................................................... 8 6 Radio Spectrum Technical Requirement ..........................................................................................11 6.1 Antenna Requirement .................................................................................................................11 6.1.1 Test Requirement: ..................................................................................................................11 6.1.2 Conclusion ..............................................................................................................................11 7 Radio Spectrum Matter Test Results ................................................................................................12 7.1 Conducted Peak Output Power ...................................................................................................12 7.1.1 E.U.T. Operation .....................................................................................................................12 7.1.2 Test Mode Description ............................................................................................................12 7.1.3 Test Setup Diagram ................................................................................................................12 7.1.4 Measurement Procedure and Data .........................................................................................13 7.2 Minimum 6dB Bandwidth ...................................…

Text truncated - open the document above for the full version.

Test Report

SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-01 Rev 1.1 Report No.: GZCR230400034206 Page: 1 of 88 FCC ID: 2ADODJ222324R Ricky Liu Manager TEST REPORT Application No.: GZCR2304000342HS Applicant: CliQ Limited Address of Applicant: 207 Record Hall, 16-16A Baldwin's Gardens, London EC1N 7RJ Manufacturer: CliQ Limited Address of Manufacturer: 207 Record Hall, 16-16A Baldwin's Gardens, London EC1N 7RJ Factory: CliQ Limited Address of Factory: 207 Record Hall, 16-16A Baldwin's Gardens, London EC1N 7RJ Equipment Under Test (EUT): EUT Name: Massage Device & Remote Model No.: JJR1 Trade Mark: Je Joue Standard(s) : 47 CFR Part 15, Subpart C 15.247 Date of Receipt: 2023-04-06 Date of Test: 2023-04-17 to 2023-04-24 Date of Issue: 2023-08-22 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-01 Rev 1.1 Report No.: GZCR230400034206 Page: 2 of 88 Revision Record Version Report No. Date Remark 01 GZCR230400034206 2023-08-22 Original Authorized for issue by: Kevin Zhang/Project Engineer Vico Cui/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-01 Rev 1.1 Report No.: GZCR230400034206 Page: 3 of 88 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C 15.247 N/A 47 CFR Part 15, Subpart C 15.203 & 15.247(b)(4) Pass Other requirements Frequency Hopping Spread Spectrum System Hopping Sequence N/A 47 CFR Part 15, Subpart C 15.247(a)(1),(g),(h) Pass Radio Spectrum Matter Part Item Standard Method Requirement Result Conducted Peak Output Power 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 7.8.5 47 CFR Part 15, Subpart C 15.247(b)(1) Pass 20dB Bandwidth ANSI C63.10 (2013) Section 7.8.7 47 CFR Part 15, Subpart C 15.247(a)(1) Pass Carrier Frequencies Separation ANSI C63.10 (2013) Section 7.8.2 47 CFR Part 15, Subpart C 15.247a(1) Pass Hopping Channel Number ANSI C63.10 (2013) Section 7.8.3 47 CFR Part 15, Subpart C 15.247a(1)(iii) Pass Dwell Time ANSI C63.10 (2013) Section 7.8.4 47 CFR Part 15, Subpart C 15.247a(1)(iii) Pass Conducted Band Edges Measurement ANSI C63.10 (2013) Section 7.8.6 47 CFR Part 15, Subpart C 15.247(d) Pass Conducted Spurious Emissions ANSI C63.10 (2013) Section 7.8.8 47 CFR Part 15, Subpart C 15.247(d) Pass Radiated Emissions which fall in the restricted bands ANSI C63.10 (2013) Section 6.10.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Below 1GHz ANSI C63.10 (2013) Section 6.4,6.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Above 1GHz ANSI C63.10 (2013) Section 6.6 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Note: E.U.T./EUT means Equipment Under Test. Pass means the test result passed the test standard requirement, please find the detailed decision rule in the report relative section. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-01 Rev 1.1 Report No.: GZCR230400034206 Page: 4 of 88 3 Contents Page 1 Cover Page ......................................................................................................................................... 1 2 Test Summary ..................................................................................................................................... 3 3 Contents ............................................................................................................................................. 4 4 General Information............................................................................................................................ 6 4.1 Details of E.U.T. ........................................................................................................................... 6 4.2 Description of Support Units ......................................................................................................... 6 4.3 Measurement Uncertainty ............................................................................................................ 6 4.4 Test Location ............................................................................................................................... 7 4.5 Test Facility .................................................................................................................................. 7 4.6 Deviation from Standards ............................................................................................................. 7 4.7 Abnormalities from Standard Conditions ....................................................................................... 7 5 Equipment List ................................................................................................................................... 8 6 Radio Spectrum Technical Requirement ..........................................................................................11 6.1 Antenna Requirement .................................................................................................................11 6.1.1 Test Requirement: ..................................................................................................................11 6.1.2 Conclusion ..............................................................................................................................11 6.2 Other requirements Frequency Hopping Spread Spectrum System Hopping Sequence ...............12 6.2.1 Test Requirement: ..................................................................................................................12 6.2.2 Conclusion ..............................................................................................................................12 7 Radio Spectrum Matter Test Results ................................................................................................13 7.1 Conducted Peak Output Power .....…

Text truncated - open the document above for the full version.

Test Setup Photos

SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-04 Rev 1.1 Page: 1 of 2 Appendix Test Setup Photo for GZCR230400034205 & GZCR230400034206 Test Model No.: JJR1 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-04 Rev 1.1 Page: 2 of 2 Test Setup Photo Radiated Emissions which fall in the restricted bands & Radiated Spurious Emissions

Contact Information

Applicant

Zhengyu Lin(Operation Manager)
[email protected]4402078318707Fax: 4402071830791

Technical Contact

SGS-CSTC Standards Technical Services Co., LtdBonnie Liao
[email protected]+862082155379

No.198 Kezhu Road, Science City Economic & · Guangzhou, Guangdong · China

Non-Technical Contact

SGS-CSTC Standards Technical Services Co., LtdBonnie Liao
[email protected]+862082155379

Test Firm

SGS-CSTC Standards Technical Services Co., Ltd.Bonnie Liao
[email protected]02082155379

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.40 mW
Confidentiality
Long Term
Grant Notes
Power Output listed is conducted.

Other Applications from CLIQ LIMITED

Massage Device & Remote - FCC ID 2ADODJ222324 - CLIQ LIMITED
2ADODJ222324

Massage Device & Remote

Sep 02, 2023

Equipment Class

DTS - Digital Transmission System
Massage Device - FCC ID 2ADODJ1213R - CLIQ LIMITED
2ADODJ1213R

Massage Device

Feb 08, 2015

Equipment Class

DTS - Digital Transmission System
Massage Device - FCC ID 2ADODJ12J13 - CLIQ LIMITED
2ADODJ12J13

Massage Device

Feb 08, 2015

Equipment Class

DTS - Digital Transmission System