Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Mar 11, 2015
Application Purpose
Original Equipment
Date of Application
Mar 11, 2015
Equipment Note
Ankle Bracelet Transmitter
Frequency Range
916.50000000 - 916.50000000
Company
PGS Medical Research & Electronic Design, LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 TrackViews_ID tm USER MANUAL for: RECEIVER Model # REC‐103 ANKLE TRANSMITTER Model# XTMR 103 DATE: 01‐30‐15 2 DESCRIPTION: The Trackview ID system is designed to monitor individuals wirelessly. Two components are utilized for this monitoring: REC‐103 Receiver XTMR 103 Transmitter ankle bracelet The system provides data as to the wearers physical activity level, heart rate, and approximate location within the monitored area. This information is highly useful in institutional settings where numerous individuals must be accounted for both in location and in health status. The REC‐103 receivers may be connected via the internal USB output to any compliant infrastructure such as a WIFI, Ethernet, or USB network. The information is processed and displayed at a remote server running the companies Graphical User Interface and Display software. Up to 200 receivers may be connected via the network at any one time. The accuracy of the location feature of the system is directly related to the number AND density of the receivers‐ 3 receivers within a 25 foot circumference being optimal. A linear spacing of 30 feet also gives good location data providing localization down to 15 feet. SET UP: This manual addresses only the hardware installation and use of the equipment. Setup is simple and straight forward provided these basic instructions and suggested installation precautions are followed. Please refer to the Unintentional Interference section at the end of this manual. Please Refer to Figures Below: 3 RECEIVER INSTALLATION‐ 1. The REC‐103 must be connected to its Wall converter which is plugged into any standard 120 Volt AC Mains outlet. 2. Remove the bottom Battery compartment cover and install a 9 volt Battery. 3. Take the supplied Antenna and screw it into the F type connector jack on the side of the REC‐103 4. Using the USB cable supplied, plug the cable into the REC‐103. Plug the other end of this cable into any existing network using an appropriate converter. For example a serial to Ethernet converter will allow the data to enter the network and be supplied to the server running the GUI (Graphic User Interface). 5. Locate the receivers as high as possible with 8 ft being a nominal height. It is important to make sure that there are no obstructions immediately in front of the REC‐103 as this may cause attenuation of the received signals from the XTMR 103 Ankle Bracelet’s transmitter. ANKLE TRANSMITTER XTMR 103 SET UP XTMR 103 Application‐ 1. Activate the XTMR 103 by removing the tab on the side of the unit. 2. Apply the ankle bracelet and bring it to a slightly snug position on the ankle. 3. Use the locking mechanism provided to secure the XTMR 103 to the individual. 4 The system is fully operational at this point and is transmitting data to the server every 30 seconds. End of Installation Instructions General Specifications: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1).this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation XTMR 103 Transmitter Photo Transducer – Wireless RFID Frequency of Operation Power Requirements 4 emitters / receivers 916.5 MHz( ISM Band) 3 volt Lithium 1000 ma/hr High Output Infrared 915 nm RFID Range 60 ft indoor/ 140 ft outdoor RFID (# Unique IDs) 1 million Battery Life 2800 Hrs ( 120 days) Modulation OOK ( on off Key) REC-103 Display Receiver Size 6 x 4 x 1.5” Frequency of Operation Power Requirement Outputs 916.5 MHz.( ISM Band) 5 Volt wall adapter or 4 AA ( 5 Days continuous) USB DATA Channels Heart Rate Motion REC Battery XTMR Battery REC ID XTMR ID Tamper RSSI ( Signal Strength) 5 CAUTION: Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment. RADIO AND TELEVISION INTERFERENCE This equipment has been tested and found to comply with the limits, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ‐ Reorient or relocate the receiving antenna. ‐ Increase the separation between the equipment and the receiver. ‐ Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ‐ Consult the dealer or an experienced radio/TV technician for help. You may also find helpful the following booklet, prepared by the FCC: ʺHow to Identify and Resolve Radio‐TV Interference Problems.ʺ This booklet is available from the U.S. Government Printing Office, Washington D.C. 20402. Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission’s rules.

Cover Letter(s)

PGS MEDICAL RESEARCH & ELECTRONIC DESIGN, LLC 55 COVE ROAD NORTH, SOUTHAMPTON, NY TEL: 631-283-8131 1 Email: [email protected] WEB: www.pgselectronics.com Nemko Canada Inc 303 River Road Ottawa, Ontario, Canada K1V 1H2 Attn: Director of Certification Authority to Act as Agent- FCC On our behalf, I authorize Nemko-CCL, Inc. at 1940 W. Alexander Street, Salt Lake City, UT 84119, USA, to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. In signing this letter, Applicant certifies that neither the applicant nor any party to the application is subject to a denial of Federal benefits, that include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. § 862 because of a conviction for possession or distribution of a controlled substance. See 47 CFR 1.2002(b) for the definition of a "party" for these purposes. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Nemko Canada Inc. still resides with PGS Medical Research & Electronic Design, LLC, 55 Cove Road North, Southampton, New York, 11968, USA. Dated this 25 Day of February 20 15 Agency agreement expiration date: December 31, 2015 By: Michael J. Sciarra Signature Printed Title: President On behalf of : PGS Medical Research & Electronic Design, LLC Telephone: 631-283-8131

Cover Letter(s)

PGS MEDICAL RESEARCH & ELECTRONIC DESIGN, LLC 55 COVE ROAD NORTH, SOUTHAMPTON, NY TEL: 631-283-8131 1 Email: [email protected] WEB: www.pgselectronics.com Date: February 13, 2015 Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: 2ADQ5-103. Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type Block Diagram Schematics Operational Description Parts List The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Signed: Name: Michael Sciarra Title: President

External Photos

External Photographs Top View of the XTMR103 Back View of the XTMR103

ID Label/Location Info

PGS MEDICAL RESEARCH & ELECTRONIC DESIGN, LLC 55 COVE ROAD NORTH, SOUTHAMPTON, NY TEL: 631-283-8131 1 Email: [email protected] WEB: www.pgselectronics.com SUBJECT: FCC Label Format and Locations XTMR 103 Model# 2ADQ5 XTMR 103 (Area too small for verbiage) In the User manual This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation On the bottom of the 2ADQ5‐XTMR‐103

Internal Photos

Internal Photographs View of the Battery Side View of the Component Side View of the Inner Side of the Flex Band View of the Outer Side of the Flex Band and Antenna

RF Exposure Info

The XTMR 103 is an ankle band transmitter that operates at 916.5 MHz and has an EIRP of 0.24 mW and a duty cycle less than 1%. FCC KDB 447498 states a 5 mm distance is to be used in calculations and that rounding should be done to the nearest mW and mm. Rounding 0.24 mW will produce a 0 mW transmitter. Rounding up produces a 1 mW transmitter. Without considering duty cycle and rounding up to 1 mW, using the equation from 4.3.1, 1 mW/5 mm x .96 = 0.192 which is less than the stated 7.5 threshold for a device to be worn on an extremity. When a higher than actual duty cycle of 1% is applied, the results indicate even greater compliance. Result The EUT meets the requirements for SAR exclusion. Signed: Printed: Michael J. Sciarra

Test Report

Nemko-CCL, Inc. 1940 West Alexander Street Salt Lake City, UT 84119 801-972-6146 Test Report Certification Test Of: XTMR 103 FCC ID: 2ADQ5-103 Test Specifications: FCC PART 15, Subpart C Test Report Serial No: 273691-4.2 Applicant: PGS Medical Research & Electronic Design, LLC 55 Cove Road North Southampton, NY 11968 U.S.A Dates of Test: November 12-13, and 24, 2014 Report Issue Date: December 16, 2014 Accredited Testing Laboratory By: NVLAP Lab Code 100272-0 Nemko-CCL, Inc. TEST REPORT: 273691-4.2 REPORT ISSUE DATE 12/16/2014 Page 2 of 29 TRF-15.249SUBC Issue 2 Oct. 2014 CERTIFICATION OF ENGINEERING REPORT This report has been prepared by Nemko-CCL, Inc. to document compliance of the device described below with the requirements of Federal Communications Commission (FCC) Part 15, Subpart C. This report may be reproduced in full, partial reproduction may only be made with the written consent of the laboratory. The results in this report apply only to the sample tested. - Applicant: PGS Medical Research & Electronic Design, LLC - Manufacturer: PGS Medical Research & Electronic Design, LLC - Brand Name: TrackViewsID - Model Number: XTMR103 - FCC ID: 2ADQ5-103 On this 16 th day of December 2014, I, individually and for Nemko-CCL, Inc., certify that the statements made in this engineering report are true, complete, and correct to the best of my knowledge, and are made in good faith. Although NVLAP has recognized that the Nemko-CCL, Inc. EMC testing facilities are in good standing, this report must not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. Nemko-CCL, Inc. Tested by: Norman P. Hansen Test Technician Reviewed by: Thomas C. Jackson Certification Manager Nemko-CCL, Inc. TEST REPORT: 273691-4.2 REPORT ISSUE DATE 12/16/2014 Page 3 of 29 TRF-15.249SUBC Issue 2 Oct. 2014 TABLE OF CONTENTS PAGE SECTION 1.0 CLIENT INFORMATION .................................................................................4 SECTION 2.0 EQUIPMENT UNDER TEST (EUT)..................................................................5 SECTION 3.0 TEST SPECIFICATION, METHODS & PROCEDURES .............................6 SECTION 4.0 OPERATION OF EUT DURING TESTING....................................................9 SECTION 5.0 SUMMARY OF TEST RESULTS ...................................................................10 SECTION 6.0 MEASUREMENTS AND RESULTS ...............................................................11 APPENDIX 1 TEST PROCEDURES AND TEST EQUIPMENT .........................................16 APPENDIX 2 PHOTOGRAPHS ................................................................................................19 Nemko-CCL, Inc. TEST REPORT: 273691-4.2 REPORT ISSUE DATE 12/16/2014 Page 4 of 29 TRF-15.249SUBC Issue 2 Oct. 2014 SECTION 1.0 CLIENT INFORMATION 1.1 Applicant: Company Name: PGS Medical Research & Electronic Design, LLC 55 Cove Road North Southampton, NY 11968 U.S.A Contact Name: Michael Sciarra Title: President 1.2 Manufacturer: Company Name: PGS Medical Research & Electronic Design, LLC 55 Cove Road North Southampton, NY 11968 U.S.A Contact Name: Michael Sciarra Title: President Nemko-CCL, Inc. TEST REPORT: 273691-4.2 REPORT ISSUE DATE 12/16/2014 Page 5 of 29 TRF-15.249SUBC Issue 2 Oct. 2014 SECTION 2.0 EQUIPMENT UNDER TEST (EUT) 2.1 Identification of EUT: Brand Name: TrackViewsID Model Number: XTMR103 Serial Number: None Dimensions: Ankle Band Flex: 15.25 cm x 2.25 cm Main Housing: 6.67 cm x 5.0 cm x 1.6 cm 2.2 Description of EUT: The XTMR103 is an ankle bracelet transmitter used in a system with a REC 103 receiver in correctional institutions for monitoring inmates. The XTMR103 transmits OOK modulated at 916.5 MHz. The XTMR103 has a trace antenna and is powered by a CR2477 lithium, 3V at 1000 mA/hr battery. This report covers the transmitter circuitry of the device subject to FCC Part 15, Subpart C. The circuitry of the device, subject to FCC Part 15, Subpart B is covered in Nemko-CCL, Inc. report 273961-3. 2.3 EUT and Support Equipment: The FCC ID numbers for all the EUT and support equipment used during the test are listed below: Brand Name Model Number Serial Number FCC ID Number or Compliance Description Name of Interface Ports / Interface Cables BN: TrackViewsID MN: XTMR103 (Note 1) SN: None 2ADQ5-103 Transmitter See Section 2.4 Note: (1) EUT 2.4 Interface Ports on EUT: There are no interface ports on the EUT. All interfacing is via the transmitter. 2.5 Modification Incorporated/Special Accessories on EUT: There were no modifications or special accessories required to comply with the specification. Nemko-CCL, Inc. TEST REPORT: 273691-4.2 REPORT ISSUE DATE 12/16/2014 Page 6 of 29 TRF-15.249SUBC Issue 2 Oct. 2014 SECTION 3.0 TEST SPECIFICATION, METHODS & PROCEDURES 3.1 Test Specification: Title: FCC PART 15, Subpart C (47 CFR 15) 15.203, 15.207, and 15.249 Limits and methods of measurement of radio interference characteristics of radio frequency devices Purpose of Test: The tests were performed to demonstrate initial compliance 3.2 Methods & Procedures: 3.2.1 §15.203 Antenna Requirement An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this Section. The manufacturer may design the unit so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector is prohibited. This requirement does not apply to carrier current devices or to devices operated under the provisions of Sections 15.211, 15.213, 15.217, 15.219, or 15.221. Further, this requirement does not apply to intentional radiators that must be professionally installed, such as perimeter protection systems and some field disturbance sensor…

Text truncated - open the document above for the full version.

Test Setup Photos

Front View - Radiated Disturbance Worst Case Configuration Back View - Radiated Disturbance Worst Case Configuration Front View - Conducted Disturbance Worst Case Configuration Back View - Conducted Disturbance Worst Case Configuration

Contact Information

Applicant

Michael j Sciarra(President)
[email protected]631 283 8131Fax: 203 254 2340

Test Firm

VPI TechnologyJason Stewart
[email protected]801-495-2310

Technical Specifications

#Rule PartsFrequency RangePower Output
115C916.5 MHz - 916.5 MHz-
Confidentiality
Long Term