Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Smart Thermostat LITE User manual MTR03-1 SmartHome Smart Compatible Download the App & Activate Product NOTE Before using this product, please read this manual carefully and keep it for future reference. The design and specifications are subject to change without prior notice for product improvement. Consult with your dealer or manufacturer for details. The diagram above is just for reference. Please take the appearance of the actual product as the standard. Using Your Smart Thermostat With SamrtHome App User GuideInstallation Guide Safety Precautions WARNING REMINDERS Please trust the distributor or a professional installer to install the device. Installation by non-professionals may result in improper installation, electric shock, or fire. Adhere to this installation manual. Improper installation may lead to electric shock or fire. Reinstallation or changes must be performed by professionals. Do not uninstall or make changes to the device randomly. Random changes may lead to abnormal operation, heating, or fire of the HAVC system, and cause damage to the smart thermostat. Do not install the device in a place vulnerable to leakage of flammable gases. Once flammable gases are leaked and left around the smart thermostat, fire may occur. Do not operate the device with wet hands. The presence of liquids may cause electric shock or damage the device. The wiring should be rated for the thermostat current and ensure that the power supply for the smart thermostat is securely isolated. Ensure the connected cables meet CL2 requirements and meet National and local electrical standards. Otherwise, electric leakage or heating may occur. Do not alter the terminals of this device. Before drilling through the wall, ensure that there are no electrical wires, water pipes, or gas pipes inside the wall. Please install the power supply unit according to the instructions in this manual. Do not alter the power supply unit or use non-specified power supply products. During installation and use of the thermostat, please prevent liquid (water, alcohol, etc.) from entering the device. Always disconnect the device from the power source before installation or maintenance to avoid equipment damage or potential electrical shock. Included In The Box: Smart Thermosta t Owner’s Manual M-base 2 Screws & 2 Anchors Quick Guide Click to change the mode & setpoint Indoor Temperature Indoor Humidity Current Mode BackHomeMenu Scroll down to see more information Model: MTR03-1 FCC ID: 2ADQOMDNA28 IC: 12575A-MDNA28 Product Information Software Class : Class A: Control functions which are not intended to be relied upon for the safety of the equipment. Overvoltage Category: I Pollution Degree: 2 Protection against electric shock class - Class III Environment: Enclosed Indoor use only, IP00 Operating ambient operating temperature: 32-95 °F (0-35 °C) Shipping and Storage temperature: -40-140 °F (-40-60 °C) Compatibility This unit works with specific communication systems by HA & HB. HA & HB: communication non-polarity R & C: 24Volts Power. Inputs: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Smart Thermostat LITE ConnectionTypeRatingTerminals 1 2 Supply Power Supply Power (non-polarity) 24Vac, 50/60Hz, Class 2 Max 24 Vdc, Class 2 AC24+:CAC24-:R HA, HB Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: --Reorient or relocate the receiving antenna. --Increase the separation between the equipment and receiver. --Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. --Consult the dealer or an experienced radio/TV technician for help. FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body. This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. IC Warning This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device. Smart Thermostat LITE Mode d'emploi MTR03-1 SmartHome Smart Compatible Download the App & Activate Product REMARQUE Avant d'utiliser ce produit, veuillez lire attentivement ce manuel et le conserver pour toute référence ultérieure. La conception et les spécifications sont susceptibles d'être modifiées sans préavis à des fins d'amélioration du produit. Consultez votre revendeur ou le fabricant pour plus de détails. Le schéma ci-dessus est fourni à titre de référence uniquement. Veuillez vous référer à l'…
Text truncated - open the document above for the full version.
GD Midea Air-Conditioning Equipment Co.,Ltd Declaration Letter of Model Difference Date: 2026-08-06 FCC ID: 2ADQOMDNA28 Tested Model Number: MTR03-1 Adding Model Number(s): TR03-1 All Adding Model Number(s) is/are same electrically identical as Tested Model Number. Only model name is different. Yours Sincerely, Applicant: GD Midea Air-Conditioning Equipment Co.,Ltd Address: Lingang Road, Beijiao, Shunde, FOSHAN, Guangdong 528311 Contact Person: Flora Wu Tel.: +86-757- 23606794 Email: [email protected] Sincerely, Signature:
Page 1 of 3 Report No.: LGT26H039 Appendix - External Photographs of EUT Constructional Details Photo 1 Photo 2 Page 2 of 3 Report No.: LGT26H039 Appendix - External Photographs of EUT Constructional Details Photo 3 Photo 4 Page 3 of 3 Report No.: LGT26H039 Appendix - External Photographs of EUT Constructional Details Photo 5 Photo 6
Label
Page 1 of 5 Report No.: LGT26H039 Appendix - Internal Photographs of EUT Constructional Details Photo 1 Photo 2 Page 2 of 5 Report No.: LGT26H039 Appendix - Internal Photographs of EUT Constructional Details Photo 3 Photo 4 Page 3 of 5 Report No.: LGT26H039 Appendix - Internal Photographs of EUT Constructional Details Photo 5 Photo 6 ANT Page 4 of 5 Report No.: LGT26H039 Appendix - Internal Photographs of EUT Constructional Details Photo 7 Photo 8 Page 5 of 5 Report No.: LGT26H039 Appendix - Internal Photographs of EUT Constructional Details Photo 9
The test report is effective only with both signature and specialized stamp. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report only apply to the tested sample. Shenzhen LGT Test Service Co., Ltd. Tel: 0755-89668180 E-mail:[email protected] Web: www.lgt-cert.com Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Page 1 of 8 EMF TEST REPORT Product Name: Smart Thermostat Model Number: MTR03-1, TR03-1 FCC ID: 2ADQOMDNA28 Issued For : GD Midea Air-Conditioning Equipment Co.,Ltd Lingang Road, Beijiao, Shunde, FOSHAN, Guangdong 528311 Issued By : Shenzhen LGT Test Service Co., Ltd. Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Report Number: LGT26H039HA01 Sample Received Date: Mar. 03, 2026 Date of Test: Mar. 09, 2026 ~ Apr. 02, 2026 Date of Issue: Aug. 06, 2026 Report No.: LGT26H039HA01 Page 2 of 8 TEST REPORT CERTIFICATION Applicant: GD Midea Air-Conditioning Equipment Co.,Ltd Address: Lingang Road, Beijiao, Shunde, FOSHAN, Guangdong 528311 Manufacturer: GD Midea Air-Conditioning Equipment Co.,Ltd Address: Lingang Road, Beijiao, Shunde, FOSHAN, Guangdong 528311 Product Name: Smart Thermostat Trademark: Midea Model Number: MTR03-1, TR03-1 Sample Status: Normal APPLICABLE STANDARDS STANDARD TEST RESULTS FCC 47 CFR §2.1091 KDB 447498 D01 General RF Exposure Guidance v06 PASS Prepared by: Approved by: Chris Chen Vita Li Engineer Technical Director Report No.: LGT26H039HA01 Page 3 of 8 TABLE OF CONTENTS 1 . GENERAL INFORMATION 5 1.1 GENERAL DESCRIPTION OF THE EUT 5 1.2 TEST LABORATORY 5 2 . FCC 47CFR §2.1091 REQUIREMENT 6 2.1 TEST STANDARDS 6 2.2 LIMIT 6 2.3 EUT OPERATION CONDITION 7 2.4 CLASSIFICATION 7 2.5 TEST RESULT 8 Report No.: LGT26H039HA01 Page 4 of 8 Revision History Rev. Issue Date Revisions 00 Aug. 06, 2026 Initial Issue Note: All test results are reported based on report LGT26C024HA01. The products are identical except for the addition of one series number: TR03-1. According to the Applicant Model Difference Statement, no further testing is required, so this report is issued accordingly. Report No.: LGT26H039HA01 Page 5 of 8 1. GENERAL INFORMATION 1.1 GENERAL DESCRIPTION OF THE EUT Product Name: Smart Thermostat Test Model Number: MTR03-1 Series Number: TR03-1 Model Difference: Only difference in model name. Frequency Bands: Bluetooth 2402-2480MHz 2.4G WLAN 802.11b/g/n/ax(20MHz): 2412~2462MHz Rating: Input: AC 24V 50/60Hz Hardware Version: V0.4 Software Version: N/A 1.2 TEST LABORATORY Company Name: Shenzhen LGT Test Service Co., Ltd. Address: Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Accreditation Certificate: FCC Registration No.: 746540 CAB ID: CN0136 Report No.: LGT26H039HA01 Page 6 of 8 2. FCC 47CFR §2.1091 REQUIREMENT 2.1 TEST STANDARDS The limit for Maximum Permissible Exposure (MPE) specified in FCC 1.1310 is followed. The gain of the antennas used in the product is extracted from the Antenna data sheets provided and also the maximum total power input to the antenna is measured. Through the Friis transmission formula and the maximum gain of the antenna, we can calculate the distance, away from the product, where the limit of MPE is reached. Although the Friis Transmission formula is far field assumption, the calculated result of that is an over-prediction for near field power density. It is taken as worst case to specify the safety range. 2.2 LIMIT According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environmental impact of the human exposure to radio-frequency (RF) radiation as specified in 1.1307 (b) Limits for Maximum Permissible Exposure (MPE) Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm²) Limits for Occupational / controlled Exposures 0.3-3.0 614 1.63 *(100) 3.0-30 1842/f 4.89/f *(900/f 2 ) 30-300 61.4 0.163 1.0 300 - 1500 -- -- F/300 1500 – 100000 -- -- 5.0 Limits for General population / Uncontrolled Exposure 0.3-1.34 614 1.63 *(100) 1.34-30 824/f 2.19/f *(180/f 2 ) 30-300 27.5 0.073 0.2 300 - 1500 -- -- F/1500 1500 – 100000 -- -- 1.0 F= Frequency in MHz * = Plane-wave equivalent power density. Friss Formula Friss Transmission Formula: Pd = (Pout * G) / (4*pi*r²) Where Pd = power density in mW/cm² Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = Distance between observation point and the center of radiator in cm If we know the maximum gain of the antenna and the total output power to the antenna, through calculation, we will know MPE value at distance 20cm. Report No.: LGT26H039HA01 Page 7 of 8 2.3 EUT OPERATION CONDITION EUT was enabled to transmit and receive at lowest, middle and highest channels. 2.4 CLASSIFICATION The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. Warning statement to the user for keeping at least 20cm or more separation distance from the antenna should be included in the User manual. So, this device is classified as Mobile device. Report No.: LGT26H039HA01 Page 8 of 8 2.5 TEST RESULT Turn up Result Mode Turn up Power BLE 1M-GFSK 4.5±1dBm BLE 2M-GFSK 4.5±1dBm 2.4G WIFI-802.11b 15±1dBm 2.4G WIFI-802.11g 14±1dBm 2.4G WIFI-802.11n(HT20) 14±1dBm 2.4G WIFI-802.11ax(HE20) 14.5±1dBm The MPE result of worst mode: RF Function Max Turn up Power (dBm) Max Turn up Power (mW) ANT Gain (dBi) ANT Gain (gain of antenna in linear scale) Power Density (mW/cm²) Limit (mW/cm²) Ratio Result BLE 5.50 3.55 1.42 1.39 0.001 1 0.001 Pass 2.4G WIFI 16.00 39.81 1.42 1.39 0.011 1 0.011 Pass Multiple transmission: BLE+2.4G WIFI=0.001+0.011=0.012<1 Note: 1. The RF Exposure is less than the limit, …
Text truncated - open the document above for the full version.
The test report is effective only with both signature and specialized stamp. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report only apply to the tested sample. Shenzhen LGT Test Service Co., Ltd. Tel: 0755-89668180 E-mail:[email protected] Web: www.lgt-cert.com Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Page 1 of 57 RF TEST REPORT Product Name: Smart Thermostat Model Number: MTR03-1, TR03-1 FCC ID: 2ADQOMDNA28 Issued For : GD Midea Air-Conditioning Equipment Co.,Ltd Lingang Road, Beijiao, Shunde, FOSHAN, Guangdong 528311 Issued By : Shenzhen LGT Test Service Co., Ltd. Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Report Number: LGT26H039RF01 Sample Received Date: Mar. 03, 2026 Date of Test: Mar. 09, 2026 ~ Apr. 02, 2026 Date of Issue: Aug. 06, 2026 Report No.: LGT26H039RF01 Page 2 of 57 TEST REPORT CERTIFICATION Applicant: GD Midea Air-Conditioning Equipment Co.,Ltd Address: Lingang Road, Beijiao, Shunde, FOSHAN, Guangdong 528311 Manufacturer: GD Midea Air-Conditioning Equipment Co.,Ltd Address: Lingang Road, Beijiao, Shunde, FOSHAN, Guangdong 528311 Product Name: Smart Thermostat Trademark: Midea Model Number: MTR03-1, TR03-1 Sample Status: Normal APPLICABLE STANDARDS STANDARD TEST RESULTS FCC Part 15.247, Subpart C ANSI C63.10-2020+COR. 1-2023+C63.10A-2024 + ERRATA TO C63.10A-2024 PASS Prepared by: Approved by: Chris Chen Vita Li Engineer Technical Director Report No.: LGT26H039RF01 Page 3 of 57 Table of Contents Page 1. SUMMARY OF TEST RESULTS 6 1.1 TEST LABORATORY 7 1.2 MEASUREMENT UNCERTAINTY 7 2. GENERAL INFORMATION 8 2.1 GENERAL DESCRIPTION OF THE EUT 8 2.2 DESCRIPTION OF THE TEST MODES 9 2.3 TEST SOFTWARE AND POWER LEVEL 9 2.4 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS 10 2.5 EQUIPMENTS LIST 11 3. EMC EMISSION TEST 13 3.1 CONDUCTED EMISSION MEASUREMENT 13 3.2 TEST PROCEDURE 14 3.3 TEST SETUP 14 3.4 EUT OPERATING CONDITIONS 14 3.5 TEST RESULTS 15 4. RADIATED EMISSION MEASUREMENT 17 4.1 RADIATED EMISSION LIMITS 17 4.2 TEST PROCEDURE 19 4.3 TEST SETUP 19 4.4 EUT OPERATING CONDITIONS 20 4.5 FIELD STRENGTH CALCULATION 20 4.6 TEST RESULTS (BAND EDGE REQUIREMENTS) 26 5. CONDUCTED SPURIOUS & BAND EDGE EMISSION 28 5.1 LIMIT 28 5.2 TEST PROCEDURE 28 5.3 TEST SETUP 28 5.4 EUT OPERATION CONDITIONS 28 5.5 TEST RESULTS 28 6. POWER SPECTRAL DENSITY TEST 29 6.1 LIMIT 29 6.2 TEST PROCEDURE 29 6.3 TEST SETUP 29 6.4 EUT OPERATION CONDITIONS 29 Report No.: LGT26H039RF01 Page 4 of 57 6.5 TEST RESULTS 29 7. BANDWIDTH TEST 30 7.1 LIMIT 30 7.2 TEST PROCEDURE 30 7.3 TEST SETUP 30 7.4 EUT OPERATION CONDITIONS 30 7.5 TEST RESULTS 30 8. PEAK OUTPUT POWER TEST 31 8.1 LIMIT 31 8.2 TEST PROCEDURE 31 8.3 TEST SETUP 31 8.4 EUT OPERATION CONDITIONS 31 8.5 TEST RESULTS 31 9. ANTENNA REQUIREMENT 32 9.1 STANDARD REQUIREMENT 32 9.2 EUT ANTENNA 32 APPENDIX I - TEST RESULTS 33 DUTY CYCLE 33 MAXIMUM PEAK CONDUCTED OUTPUT POWER 36 -6DB BANDWIDTH 39 OCCUPIED CHANNEL BANDWIDTH 42 MAXIMUM POWER SPECTRAL DENSITY LEVEL 45 BAND EDGE 48 CONDUCTED RF SPURIOUS EMISSION 52 APPENDIX II - MEASUREMENT PHOTOS 57 Report No.: LGT26H039RF01 Page 5 of 57 Revision History Rev. Issue Date Revisions 00 Aug. 06, 2026 Initial Issue Note: All test results are reported based on report LGT26C024RF01. The products are identical except for the addition of one series number: TR03-1. According to the Applicant Model Difference Statement, no further testing is required, so this report is issued accordingly. Report No.: LGT26H039RF01 Page 6 of 57 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: KDB 558074 D01 Part 15.247 Meas Guidance v05r02. FCC Part 15.247, Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission PASS -- 15.247 (a)(2) 6dB Bandwidth PASS -- 15.247 (b)(3) Output Power PASS -- 15.209 Radiated Spurious Emission PASS -- 15.247 (d) Conducted Spurious & Band Edge Emission PASS -- 15.247 (e) Power Spectral Density PASS -- 15.205 Restricted Band Edge Emission PASS -- Part 15.247(d)/ Part 15.209(a) Band Edge Emission PASS -- 15.203 Antenna Requirement PASS -- NOTE: (1) ‘N/A’ denotes test is not applicable in this Test Report. (2) All tests are according to ANSI C63.10-2020+COR. 1-2023+C63.10A-2024 + ERRATA TO C63.10A-2024. Report No.: LGT26H039RF01 Page 7 of 57 1.1 TEST LABORATORY Company Name: Shenzhen LGT Test Service Co., Ltd. Address: Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Accreditation Certificate: FCC Registration No.: 746540 CAB ID: CN0136 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. No. Item Uncertainty 1 Occupied Channel Bandwidth ±0.46% 2 RF Output Power, Conducted ±0.71dB 3 Power Spectral Density, Conducted ±1.57dB 4 Unwanted Emission, Conducted ±0.63dB 5 Conducted emission ±2.80dB 6 All Emissions, Radiated (0.009-30MHz) ±2.16dB 7 All Emissions, Radiated (30MHz-1GHz) ±4.61dB 8 All Emissions, Radiated (1GHz-18GHz) ±5.49dB 9 Temperature ±0.5°C 10 Humidity ±2% 11 Duty Cycle ±2.3% Note: The measurement uncertainty is not included in the test result. Report No.: LGT26H039RF01 Page 8 of 57 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF THE EUT Product Name: Smart Thermostat Test Model Number: MTR03-1 Series Number: TR03-1 Model Difference: Only difference in model name. Product Description: Operation Frequency: 2402~2480 MHz Modulation Type: GFSK Radio Technology: BLE Bluetooth Configuration: BLE (1M PHY, 2M PHY) Number Of Channel: 40 Antenna Designation: PCB Antenna Gain (dBi) 1.42 Chan…
Text truncated - open the document above for the full version.
The test report is effective only with both signature and specialized stamp. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report only apply to the tested sample. Shenzhen LGT Test Service Co., Ltd. Tel: 0755-89668180 E-mail:[email protected] Web: www.lgt-cert.com Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Page 1 of 71 RF TEST REPORT Product Name: Smart Thermostat Model Number: MTR03-1, TR03-1 FCC ID: 2ADQOMDNA28 Issued For : GD Midea Air-Conditioning Equipment Co.,Ltd Lingang Road, Beijiao, Shunde, FOSHAN, Guangdong 528311 Issued By : Shenzhen LGT Test Service Co., Ltd. Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Report Number: LGT26H039RF02 Sample Received Date: Mar. 03, 2026 Date of Test: Mar. 09, 2026 ~ Apr. 02, 2026 Date of Issue: Aug. 10, 2026 Report No.: LGT26H039RF02 Page 2 of 71 TEST REPORT CERTIFICATION Applicant: GD Midea Air-Conditioning Equipment Co.,Ltd Address: Lingang Road, Beijiao, Shunde, FOSHAN, Guangdong 528311 Manufacturer: GD Midea Air-Conditioning Equipment Co.,Ltd Address: Lingang Road, Beijiao, Shunde, FOSHAN, Guangdong 528311 Product Name: Smart Thermostat Trademark: Midea Model Number: MTR03-1, TR03-1 Sample Status: Normal APPLICABLE STANDARDS STANDARD TEST RESULTS FCC Part 15.247, Subpart C ANSI C63.10-2020+COR. 1-2023+C63.10A-2024 + ERRATA TO C63.10A-2024 PASS Prepared by: Approved by: Chris Chen Vita Li Engineer Technical Director Report No.: LGT26H039RF02 Page 3 of 71 Table of Contents Page 1. SUMMARY OF TEST RESULTS 6 1.1 TEST LABORATORY 7 1.2 MEASUREMENT UNCERTAINTY 7 2. GENERAL INFORMATION 8 2.1 GENERAL DESCRIPTION OF THE EUT 8 2.2 DESCRIPTION OF THE TEST MODES 10 2.3 TEST SOFTWARE AND POWER LEVEL 10 2.4 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS 11 2.5 EQUIPMENTS LIST FOR ALL TEST ITEMS 12 3. EMC EMISSION TEST 14 3.1 CONDUCTED EMISSION MEASUREMENT 14 3.2 RADIATED EMISSION MEASUREMENT 18 4. CONDUCTED SPURIOUS & BAND EDGE EMISSION 29 4.1 LIMIT 29 4.2 TEST PROCEDURE 29 4.3 DEVIATION FROM STANDARD 29 4.4 TEST SETUP 29 4.5 EUT OPERATION CONDITIONS 29 4.6 TEST RESULTS 29 5. POWER SPECTRAL DENSITY TEST 30 5.1 LIMIT 30 5.2 TEST PROCEDURE 30 5.3 DEVIATION FROM STANDARD 30 5.4 TEST SETUP 30 5.5 EUT OPERATION CONDITIONS 30 5.6 TEST RESULTS 30 6. BANDWIDTH TEST 31 6.1 LIMIT 31 6.2 TEST PROCEDURE 31 6.3 DEVIATION FROM STANDARD 31 6.4 TEST SETUP 31 6.5 EUT OPERATION CONDITIONS 31 6.6 TEST RESULTS 31 Report No.: LGT26H039RF02 Page 4 of 71 7. PEAK OUTPUT POWER TEST 32 7.1 LIMIT 32 7.2 TEST PROCEDURE 32 7.3 DEVIATION FROM STANDARD 32 7.4 TEST SETUP 32 7.5 EUT OPERATION CONDITIONS 32 7.6 TEST RESULTS 32 8. ANTENNA REQUIREMENT 33 8.1 STANDARD REQUIREMENT 33 8.2 EUT ANTENNA 33 APPENDIX I - TEST RESULTS 34 DUTY CYCLE 34 MAXIMUM PEAK CONDUCTED OUTPUT POWER 39 -6DB BANDWIDTH 40 OCCUPIED CHANNEL BANDWIDTH 45 MAXIMUM POWER SPECTRAL DENSITY LEVEL 50 BAND EDGE 55 CONDUCTED RF SPURIOUS EMISSION 62 APPENDIX II - MEASUREMENT PHOTOS 71 Report No.: LGT26H039RF02 Page 5 of 71 Revision History Rev. Issue Date Revisions 00 Aug. 10, 2026 Initial Issue Note: All test results are reported based on report LGT26C024RF02. The products are identical except for the addition of one series number: TR03-1. According to the Applicant Model Difference Statement, no further testing is required, so this report is issued accordingly. Report No.: LGT26H039RF02 Page 6 of 71 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: KDB 558074 D01 15.247 Meas Guidance v05r02. FCC Part 15.247,Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission PASS -- 15.247 (a)(2) 6dB Bandwidth PASS -- 15.247 (b)(3) Output Power PASS -- 15.209 Radiated Spurious Emission PASS -- 15.247 (d) Conducted Spurious & Band Edge Emission PASS -- 15.247 (e) Power Spectral Density PASS -- 15.205 Restricted Band Edge Emission PASS -- Part 15.247(d)/ Part 15.209(a) Band Edge Emission PASS -- 15.203 Antenna Requirement PASS -- NOTE: (1) ‘N/A’ denotes test is not applicable in this Test Report. (2) All tests are according to ANSI C63.10-2020+COR. 1-2023+C63.10A-2024 + ERRATA TO C63.10A-2024. (3) The 802.11ax mode is investigated among different tones(26/52/106/242-tone RU channel), full resource units (RU), partial resourceunits. The partial RU has no higher power than full RU's, thus the full RU is chosen as main testconfiguration. Report No.: LGT26H039RF02 Page 7 of 71 1.1 TEST LABORATORY Company Name: Shenzhen LGT Test Service Co., Ltd. Address: Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Accreditation Certificate: FCC Registration No.: 746540 CAB ID: CN0136 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. Occupied Channel Bandwidth ±0.46% RF Output Power, Conducted ±0.71dB Power Spectral Density, Conducted ±1.57dB Unwanted Emission, Conducted ±0.63dB Conducted emission ±2.80dB All Emissions, Radiated (0.009-30MHz) ±2.16dB All Emissions, Radiated (30MHz-1GHz) ±4.61dB All Emissions, Radiated (1GHz-18GHz) ±5.49dB Temperature ±0.5°C Humidity ±2% Duty Cycle ±2.3% Note: The measurement uncertainty is not included in the test result. Report No.: LGT26H039RF02 Page 8 of 71 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF THE EUT Product Name: Smart Thermostat Test Model Number: MTR03-1 Series Number: TR03-1 Model Difference: Only difference in model name. Product Description: Operation Frequency: 802.11b/g/n/ax(20MHz): 2412~2462MHz Modulation Type: 802.11b(DSSS):CCK,DQPSK,DBPSK 802.11g(OFDM):BPSK,QPSK,16-QAM…
Text truncated - open the document above for the full version.
Report No.: LGT26H039RF02 Page 49 of 71 OBW NVNT ax20 2412MHz OBW NVNT ax20 2437MHz OBW NVNT ax20 2462MHz Report No.: LGT26H039RF02 Page 50 of 71 Maximum Power Spectral Density Level Condition Mode Frequency (MHz) Conducted PSD (dBm/3kHz) Limit (dBm/3kHz) Verdict NVNT b 2412 -7.97 8 Pass NVNT b 2437 -7.27 8 Pass NVNT b 2462 -6.74 8 Pass NVNT g 2412 -11.01 8 Pass NVNT g 2437 -10.38 8 Pass NVNT g 2462 -10.15 8 Pass NVNT n20 2412 -10.51 8 Pass NVNT n20 2437 -10.03 8 Pass NVNT n20 2462 -10.16 8 Pass NVNT ax20 2412 -9.5 8 Pass NVNT ax20 2437 -9.39 8 Pass NVNT ax20 2462 -8.95 8 Pass Report No.: LGT26H039RF02 Page 51 of 71 Test Graphs PSD NVNT b 2412MHz PSD NVNT b 2437MHz PSD NVNT b 2462MHz Report No.: LGT26H039RF02 Page 52 of 71 PSD NVNT g 2412MHz PSD NVNT g 2437MHz PSD NVNT g 2462MHz Report No.: LGT26H039RF02 Page 53 of 71 PSD NVNT n20 2412MHz PSD NVNT n20 2437MHz PSD NVNT n20 2462MHz Report No.: LGT26H039RF02 Page 54 of 71 PSD NVNT ax20 2412MHz PSD NVNT ax20 2437MHz PSD NVNT ax20 2462MHz Report No.: LGT26H039RF02 Page 55 of 71 Band Edge Condition Mode Frequency (MHz) Max Value (dBc) Limit (dBc) Verdict NVNT b 2412 -46.03 -20 Pass NVNT b 2462 -53.87 -20 Pass NVNT g 2412 -38.01 -20 Pass NVNT g 2462 -51.1 -20 Pass NVNT n20 2412 -38.75 -20 Pass NVNT n20 2462 -51.42 -20 Pass NVNT ax20 2412 -33.68 -20 Pass NVNT ax20 2462 -47.27 -20 Pass Report No.: LGT26H039RF02 Page 56 of 71 Test Graphs Band Edge NVNT b 2412MHz Ref Band Edge NVNT b 2412MHz Emission Band Edge NVNT b 2462MHz Ref Report No.: LGT26H039RF02 Page 57 of 71 Band Edge NVNT b 2462MHz Emission Band Edge NVNT g 2412MHz Ref Band Edge NVNT g 2412MHz Emission Report No.: LGT26H039RF02 Page 58 of 71 Band Edge NVNT g 2462MHz Ref Band Edge NVNT g 2462MHz Emission Band Edge NVNT n20 2412MHz Ref Report No.: LGT26H039RF02 Page 59 of 71 Band Edge NVNT n20 2412MHz Emission Band Edge NVNT n20 2462MHz Ref Band Edge NVNT n20 2462MHz Emission Report No.: LGT26H039RF02 Page 60 of 71 Band Edge NVNT ax20 2412MHz Ref Band Edge NVNT ax20 2412MHz Emission Report No.: LGT26H039RF02 Page 61 of 71 Band Edge NVNT ax20 2462MHz Ref Band Edge NVNT ax20 2462MHz Emission Report No.: LGT26H039RF02 Page 62 of 71 Conducted RF Spurious Emission Condition Mode Frequency (MHz) Max Value (dBc) Limit (dBc) Verdict NVNT b 2412 -53.46 -20 Pass NVNT b 2437 -53.8 -20 Pass NVNT b 2462 -55.27 -20 Pass NVNT g 2412 -50.82 -20 Pass NVNT g 2437 -52.24 -20 Pass NVNT g 2462 -52.26 -20 Pass NVNT n20 2412 -51.46 -20 Pass NVNT n20 2437 -52.22 -20 Pass NVNT n20 2462 -45.85 -20 Pass NVNT ax20 2412 -50.82 -20 Pass NVNT ax20 2437 -51.31 -20 Pass NVNT ax20 2462 -51.79 -20 Pass Report No.: LGT26H039RF02 Page 63 of 71 Test Graphs Tx. Spurious NVNT b 2412MHz Ref Tx. Spurious NVNT b 2412MHz Emission Tx. Spurious NVNT b 2437MHz Ref Report No.: LGT26H039RF02 Page 64 of 71 Tx. Spurious NVNT b 2437MHz Emission Tx. Spurious NVNT b 2462MHz Ref Tx. Spurious NVNT b 2462MHz Emission Report No.: LGT26H039RF02 Page 65 of 71 Tx. Spurious NVNT g 2412MHz Ref Tx. Spurious NVNT g 2412MHz Emission Tx. Spurious NVNT g 2437MHz Ref Report No.: LGT26H039RF02 Page 66 of 71 Tx. Spurious NVNT g 2437MHz Emission Tx. Spurious NVNT g 2462MHz Ref Tx. Spurious NVNT g 2462MHz Emission Report No.: LGT26H039RF02 Page 67 of 71 Tx. Spurious NVNT n20 2412MHz Ref Tx. Spurious NVNT n20 2412MHz Emission Tx. Spurious NVNT n20 2437MHz Ref Report No.: LGT26H039RF02 Page 68 of 71 Tx. Spurious NVNT n20 2437MHz Emission Tx. Spurious NVNT n20 2462MHz Ref Tx. Spurious NVNT n20 2462MHz Emission Report No.: LGT26H039RF02 Page 69 of 71 Tx. Spurious NVNT ax20 2412MHz Ref Tx. Spurious NVNT ax20 2412MHz Emission Tx. Spurious NVNT ax20 2437MHz Ref Report No.: LGT26H039RF02 Page 70 of 71 Tx. Spurious NVNT ax20 2437MHz Emission Tx. Spurious NVNT ax20 2462MHz Ref Tx. Spurious NVNT ax20 2462MHz Emission Report No.: LGT26H039RF02 Page 71 of 71 APPENDIX II - MEASUREMENT PHOTOS Note: Please see the attached RF_Test Setup photos for FCC ID & IC. ※※※※※END OF THE REPORT※※※※※
Antenna Specification Antenna ElementValue E1(0402) E2(0402) E3(0402) 28# Antenna RF Module E1E3 Antenna E2 Length 20*6mm 28# WIFI Antenna Test Data Frequency bandChannelTRP(dBm)TIS (dBm) Frequency bandChannelTRP (dBm)TIS (dBm) 11b Low 17.2-85.7 Mid 17.1-85.5 Hig 17.1-85.4 28# Antenna Standing Wave Pattern 28# Antenna Efficiency Freqency(MHz)Gain(dBi)Efficiency(dB)Efficiency(%) 24001.31-3.3746.03 24101.42-3.3546.21 24201.4-3.3346.49 24301.37-3.3146.63 24401.33-3.2547.33 24501.33-3.2347.51 24601.25-3.247.89 24701.1-3.1648.29 24800.88-3.1648.31 24900.68-3.1448.51 25000.51-3.1248.74 28# 2D Picture 28# …
Text truncated - open the document above for the full version.
2700 Chestnut Station Ct. Louisville, · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 3.20 mW |
| 2 | 15C | 2.41 GHz - 2.46 GHz | 39.40 mW |