FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Cannice Technology Co., Ltd./
  3. 2ADTV-A992

2ADTV-A992ENACFIRE Wireless Earbuds

Shenzhen Cannice Technology Co., Ltd.
ENACFIRE Wireless Earbuds - FCC ID 2ADTV-A992 - Shenzhen Cannice Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Feb 01, 2021
Application Purpose
Original Equipment
Date of Application
Feb 01, 2021
Equipment Note
ENACFIRE Wireless Earbuds
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Cannice Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

ShenZhen Cannice Technology Co.,Ltd. Statement Product Name: ENACFIRE Wireless Earbuds Model No.: A992 , Forte We( ShenZhen Cannice Technology Co., Ltd.; 20/ F, Tower A, Building 7, Baoneng Science and Technology Park, Qingxiang Road #1, Longhua New District, Shenzhen, China ) All the model are the same circuit and RF module, except the model No.. Signature: Name / title: Ankey Wu / Manager Tel: +86-0755-82815261 Date: 2021/01/20

Cover Letter(s)

C5266091_X8_Ed.1 1/1 Letter of Authorization Company: ShenZhen Cannice Technology Co., Ltd. Address: 20/F, Tower A, Building 7, Baoneng Science and Technology Park, Qingxiang Road #1, Longhua New District, Shenzhen, China Product Name: ENACFIRE Wireless Earbuds Model Number: A992, Forte FCC Identifier: 2ADTV-A992 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Ankey Wu Date: 1/30/2021 Title: Manager Signature of applicant:

Cover Letter(s)

C5266091_X10_Ed.1 1/1 ShenZhen Cannice Technology Co., Ltd. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 1/30/2021 Subject: Request for Confidentiality FCC ID: 2ADTV-A992 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality ID Label/Location No No Attestation Statement No No External Photos No Block Diagram Schematics Test Report No No Test Setup Photos No User’s Manual Internal Photos Parts List / Tune Up RF Exposure Info Operational Description Cover Letter(s) No No SDR Software / Security Info No Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Ankey Wu Date: 1/30/2021 Title: Manager

External Photos

1 - Page 1 of 6 - Report No.: MTi20101629-7E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. APPENDIX 1: EUT PHOTO Photo 1 (For model A992) Photo 2 1 - Page 2 of 6 - Report No.: MTi20101629-7E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 3 Photo 4 1 - Page 3 of 6 - Report No.: MTi20101629-7E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 5 Photo 6 1 - Page 4 of 6 - Report No.: MTi20101629-7E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 7 Photo 8 1 - Page 5 of 6 - Report No.: MTi20101629-7E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 9 Photo 10 1 - Page 6 of 6 - Report No.: MTi20101629-7E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 11 Photo 12 ----END OF REPORT----

ID Label/Location Info

28.92 mm 15.06 m m 镭雕字迹清晰。 A992-01充电盒上壳镭雕 2021/01/19 V03 will A992-01充电盒上壳镭雕(认证专用) V01,初版发行 V02,耳机电流参数更新 V03,增加FCC ID    A992

Internal Photos

1 - Page 1 of 6 - Report No.: MTi20101629-7E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. APPENDIX 1: EUT PHOTO Photo 1 (For model A992) Photo 2 1 - Page 2 of 6 - Report No.: MTi20101629-7E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 3 Photo 4 1 - Page 3 of 6 - Report No.: MTi20101629-7E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 5 Photo 6 FPC antenna 1 - Page 4 of 6 - Report No.: MTi20101629-7E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 7 Photo 8 1 - Page 5 of 6 - Report No.: MTi20101629-7E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 9 Photo 10 1 - Page 6 of 6 - Report No.: MTi20101629-7E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 11 ----END OF REPORT----

RF Exposure Info

This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen Microtest Co., Ltd. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. RF EXPOSURE REPORT FCC ID: 2ADTV-A992 Date of issue: Jan. 20, 2021 Report Number: MTi20101629-7E2 Sample Description: ENACFIRE Wireless Earbuds Mo d e l( s ) : A992, Forte Applicant: ShenZhen Cannice Technology Co., Ltd. Address: 20/F, Tower A, Building 7, Baoneng Science and Technology Park, Qingxiang Road #1, Longhua New District, Shenzhen, China Date of Test: Nov. 05, 2020 to Dec. 09, 2020 Shenzhen Microtest Co., Ltd. http://www.mtitest.com - Page 2 of 4- Report No.: MTi20101629-7E2 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. TEST RESULT CERTIFICATION Applicant’s name: ShenZhen Cannice Technology Co., Ltd. Address: 20/F, Tower A, Building 7, Baoneng Science and Technology Park, Qingxiang Road #1, Longhua New District, Shenzhen, China Manufacture's name: ShenZhen Cannice Technology Co., Ltd. Address: 20/F, Tower A, Building 7, Baoneng Science and Technology Park, Qingxiang Road #1, Longhua New District, Shenzhen, China Factory: Dongguan Cannice Precision Manufacturing Co., Ltd. Address: Buiding 2, No.21, Nange West Road Daojiao Town Dongguan Guangdong 523750 China Factory: Shenzhen Cannice Technology Co., Ltd. Dongguan Branch Address: 4F, Office Building, N.o 70 Puxinhu Pulong Village, Tangxia Town, Dongguan City, Guangdong Province, P.R.China Product name: ENACFIRE Wireless Earbuds Model and/or type reference: A992, Forte Serial Model: N/A RF Exposure Procedures: KDB 447498 D01 v06 This device described above has been tested by Shenzhen Microtest Co., Ltd and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. Tested by: Demi Mu Dec. 09, 2020 Reviewed by: Leo Su Jan. 20, 2021 Approved by: Tom Xue Jan. 20, 2021 - Page 3 of 4- Report No.: MTi20101629-7E2 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. 1. Standalone SAR test exclusion considerations Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition(s), listed below, is (are) satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions. The minimum test separation distance defined in 4.1 f) is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander. To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified, typically in the SAR measurement or SAR analysis report, by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting are required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions. a) For 100 MHz to 6 GHz and test separation distances ≤ 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following: [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR, and ≤ 7.5 for 10-g extremity SAR, where  f (GHz) is the RF channel transmit frequency in GHz  Power and distance are rounded to the nearest mW and mm before calculation  The result is rounded to one decimal place for comparison  The values 3.0 and 7.5 are referred to as numeric thresholds in step b) below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm, and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 4.1 f) is applied to determine SAR test exclusion. b) For 100 MHz to 6 GHz and test separation distances > 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following (also illustrated in Appendix B): 1) {[Power allowed at numeric threshold for 50 mm in step a)] + [(test separation distance – 50 mm)·(f(MHz)/150)]} mW, for 100 MHz to 1500 MHz 2) {[Power allowed at numeric threshold for 50 mm in step a)] + [(test separation distance – 50 mm)·10]} mW, for > 1500 MHz and ≤ 6 GHz c) For frequencies below 100 MHz, the following may be considered for SAR test exclusion (also illustrated in Appendix C): 1) For test separation distances > 50 mm and < 200 mm, the power threshold at the corresponding test separation distance at 100 MHz in step b) is multiplied by [1 + log(100/f(MHz))] - Page 4 of 4- Report No.: MTi20101629-7E2 T…

Text truncated - open the document above for the full version.

Test Report

This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen Microtest Co., Ltd. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Test Report FCC ID: 2ADTV-A992 Date of issue: Jan. 20, 2021 Report number: MTi20101629-7E1 Sample description: ENACFIRE Wireless Earbuds Mo d e l( s ) : A992, Forte Applicant: ShenZhen Cannice Technology Co., Ltd. Address: 20/F, Tower A, Building 7, Baoneng Science and Technology Park, Qingxiang Road #1, Longhua New District, Shenzhen, China Date of test: Nov. 05, 2020 to Dec. 09, 2020 Shenzhen Microtest Co., Ltd. http://www.mtitest.com - Page 2 of 63 - Report No.: MTi20101629-7E1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Table of Contents 1 GENERAL INFORMATION .......................................................................................................................................... 5 1.1 DESCRIPTION OF EUT ................................................................................................................................................... 5 1.2 OPERATION CHANNEL LIST .............................................................................................................................................. 5 1.3 TEST CHANNEL LIST ....................................................................................................................................................... 6 1.4 ANCILLARY EQUIPMENT LIST ........................................................................................................................................... 6 1.5 DESCRIPTION OF SUPPORT UNITS .................................................................................................................................... 6 2 SUMMARY OF TEST RESULTS .................................................................................................................................... 7 3 TEST FACILITIES AND ACCREDITATIONS ..................................................................................................................... 8 3.1 TEST LABORATORY ........................................................................................................................................................ 8 3.2 ENVIRONMENTAL CONDITIONS ........................................................................................................................................ 8 3.3 MEASUREMENT UNCERTAINTY ........................................................................................................................................ 8 3.4 TEST SOFTWARE ........................................................................................................................................................... 8 4 EQUIPMENT LIST ...................................................................................................................................................... 9 5 TEST RESULT ........................................................................................................................................................... 10 5.1 ANTENNA REQUIREMENT ............................................................................................................................................. 10 5.1.1 Standard requirement ....................................................................................................................................... 10 5.1.2 EUT antenna ..................................................................................................................................................... 10 5.2 PEAK OUTPUT POWER ................................................................................................................................................. 11 5.2.1 Limit .................................................................................................................................................................. 11 5.2.2 Test setup .......................................................................................................................................................... 11 5.2.3 Test procedure ................................................................................................................................................... 11 5.2.4 Test results......................................................................................................................................................... 11 5.3 CONDUCTED EMISSION ................................................................................................................................................ 18 5.3.1 Limits ................................................................................................................................................................. 18 5.3.2 Test setup .......................................................................................................................................................... 18 5.3.3 Test procedure ................................................................................................................................................... 19 5.3.4 Test results......................................................................................................................................................... 19 5.4 RADIATED SPURIOUS EMISSION ...................................................................................................................................... 20 5.4.1 Limits ..............................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Model: A992 Radiated emission

Contact Information

Applicant

Ankey Wu
[email protected]0755-82815261Fax: 0755-82815261

Technical Contact

Shenzhen Microtest Co., LtdSmith Chen
[email protected]86-755 88850135

Shenzhen · China

Test Firm

Shenzhen Microtest Co., Ltd.Selby Liao
[email protected]0755-88850135-1193

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz3.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.

Other Applications from Shenzhen Cannice Technology Co., Ltd.

OTC Intelligent Hearing Aids - FCC ID 2ADTV-NANO2 - Shenzhen Cannice Technology Co., Ltd.
2ADTV-NANO2

OTC Intelligent Hearing Aids

Jul 09, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
TRUE WIRELESS EARBUDS - FCC ID 2ADTV-13535 - Shenzhen Cannice Technology Co., Ltd.
2ADTV-13535

TRUE WIRELESS EARBUDS

Mar 27, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
WIRELESS OPEN-EAR EARPHONES - FCC ID 2ADTV-30685A - Shenzhen Cannice Technology Co., Ltd.
2ADTV-30685A

WIRELESS OPEN-EAR EARPHONES

Sep 08, 2025

Equipment Class

DTS - Digital Transmission System
OTC Intelligent Hearing Aids - FCC ID 2ADTV-NANO - Shenzhen Cannice Technology Co., Ltd.
2ADTV-NANO

OTC Intelligent Hearing Aids

Sep 08, 2025

Equipment Class

DTS - Digital Transmission System
OTC Intelligent Hearing Aids - FCC ID 2ADTV-CVX1 - Shenzhen Cannice Technology Co., Ltd.
2ADTV-CVX1

OTC Intelligent Hearing Aids

Aug 25, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter