
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Specifications Name of each part LED lamp consumes power 80% less than incandescent lamp and 50% less than fluorescent lamp. Use high quality PC lampshade.Strengthen the flexible refraction of light.And its function of anti-ultraviolet makes the shade not easy to turn yellow and be broken. IQ-4455MB Microwave Sensor Light Instruction Lampshade fixed hole Lampshade fixed hole Lampshade fixed hole PC lampshade Lampshade fixed hole Threading hole 2835 Knob Switch LUX SENS TIME Lampshade fixed hole Lampshade fixed hole Adjust button of percentage brightness Summary IP 65 Microwave Sensor Light 1X Instruction Screw stopper 1X 3X 3X 3X Quantity Packing list in Φ6 Plastic Expansion 4x30 Screw This is a newly designed intelligent ceiling mount microwave sensor LED light, with the extra function of power supply in emergency. The lighting is auto-managed by AC direct power or battery backup, that is, when power failure, the battery backup will be responsible for the power supply of 3.5 watt. When light on, the luminous flux will be more than 1680 lm, equivalent to four times that of 60 watt incandescent lamp(≈400lm). The battery backup can continuously supply power for more than 3 hours or even more in the sensor energy-saving mode. It is widely applied in the corridor, washing room, elevator lobby etc. This product is designed with two configurations: one is the sensor lamp with the function of supplying power in emergency and the other one is the intelligent sensor lamp without the emergency function. You can make purchase according to the practical need. But in most cases, it is necessary and wise to choose the former one, for that the occasional power outage will cause trouble, or even danger. Battery Power source: 120-277V/AC, 60Hz Rated LED: 23W Max.(AC) 3.5W Max.(DC) Charging power: <4W Max.(light off & light on) Slaving capacity100W Max. Working temperature: -20~+55 HF system: 5.8GHz Battery: 7.4V / 2000mAH lithium battery Continuous illumination time: ≥180min Transmission power: <0.2mW Time setting: 10sec to 30min (adjustable) Detection range: 2-10m (radii.) (adjustable) Light-control: 10-2000LUX(adjustable) Detection angle: 360° Power factor0.9 Luminous flux: 1680lm(AC) 350lm(DC) Installation height: 2.5-3.5m (ceiling mount) Lamp part LED quantity: 144PCS LEDS 144PCS Information sensor Sensing distance adjustment range Sensing angle adjustment range Height of installation2.5~3.5M 2.5-3.5m Min:2mMin:2m Max:10m Max:10m 360º Fig.1 Emergency function * Installed in the elevator, when power fails, it still supports lighting for the trapped. 123123 安全出口 EXIT 安全出口 EXIT In case of sudden blackout, our products can still work properly In case of sudden blackout and there is nobody in the surroundingAfter the blackout, people evacuate from the elevator Fig.1 Function Percentage brightness mode As per the right-hand instruction, through the dial switch you can choose the LUX standard (<100LUX or <200LUX ) to trigger the percentage brightness. When the ambient brightness is less than about 100LUX or 200LUX , if no signal detected within the preset delay time, the lamp will enter 0%-30% brightness mode, and maintains until signal detected.You can adjust the percentage brightness through the button, press the button once,it will increase 10% brightness with operating indicator flicker once. when it becomes 30% brightness, press the button once,it will return to 0% brightness. In semi-brightness mode,when the environment light is up to the ligt-control value to exit,it will finish the semi-brightness mode automatically. Optical sensor AC power indicator Charging indicator Full-charged indicator Operating indicator 200 LUX 100 LUX Switch Adjust button of percentage brightness Fig.2 LUX SENS TIME Spectrogram IQ-4455MB (1680lm) 60 watt incandescent lamp(≈400lm) When light on, the luminous flux will be more than 1680 lm, equivalent to four times that of 60 watt incandescent lamp(≈400lm). Indicator function Red indicator—— AC power indicator: When connected to the AC power, the indicator lights. Orange indicator—— Charging indicator : Indicator lights when charging and be off when full charged. Green indicator—— Full-charged indicator : Full battery, the indicator lights. Fault instruction: Charging indicator constantly on ; Full-charged indicator flickering, that is, there is no battery or the battery breaks down. Setting manner one:potentiometer It may take times to adjust values before they satisfy your need. (1)Detection range setting (sensitivity) Detection range is the term used to describe the radii of the more or less circular detection zone produced on the ground after mounting the sensor light at a height of 2.5m, turn the reach control fully anticlockwise to select minimum reach (approx.2m radii), and fully clockwise to select maximum reach (approx. 10m radii). SENS NOTE: the above detection distance is gained in the case of a person who is between 1.6m~1.7m tall with middle figure and moves at a speed of 1.0~1.5m/sec. if person’s stature, figure and moving speed change, the detection distance will also change. In different cases, the sensitivity of the lights has certain deviation. Notice: when using this product, please adjust the sensitivity (detection range) to an appropriate value but the maximum to avoid the abnormal reaction caused by the easy detection of the wrong motion by the blowing leaves & curtains, small animals or the interference of power grid & electrical equipment. All the above mentioned will lead to the error reaction. When the product does not work normally, please try to lower the sensitivity appropriately, and then test it. (3)Light-control setting The chosen light response threshold can be infinitely from approx.10- 2000LUX. Turn it fully anti-clockwise to select dusk- to-dawn operation at about 10 lux. Turn it fully clockwise to select daylight operation at about 2000lux. The knob must be turned fully clockwise when adjusting the detection zone and performing the walk te…
Text truncated - open the document above for the full version.
SCS-F18: Project and Product Certification Representative Authorization Letter Page 1 of 2 Rev 5.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Project and Product Certification Representative Authorization Letter Reason for Amendment (current / obsolete) Revision History Approved Date From To Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Revised wording (obsolete) 1.0 2.0 Sept–25-2007 Updated company template (obsolete) 2.0 3.0 Jan-31-2012 Updated letter information (obsolete) 3.0 4.0 May-23-2014 Added FCC ID field (current) 4.0 5.0 Sept 16 2014 SCS-F18: Project and Product Certification Representative Authorization Letter Page 2 of 2 Rev 5.0 Aura Light International AB December 25, 2014 To: SIEMIC, INC. 775 Montague Expressway, Milpitas, CA 95035 USA Dear Sir/Madam, Re: Product Certification Representative Authorization Letter We, Aura Light International AB hereby authorize SIEMIC, Inc. to act as a Certification Body for certifying for the following project(s): LED Lamp Model name: IQ-4455MB, IQ-4455M FCC ID: 2ADVW-IQ4455MB Sincerely, Mikael Severinsson/ Quality Manager Aura Light International AB Address: Lumavagen 1, Karlskrona, Sweden Telephone: +46 45578626 Fax: +46 45526717 E-mail: [email protected]
SCS-F19: Confidentiality Request Letter Page 1 of 2 Rev 3.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Confidentiality Request Letter Reason for Amendment (current / obsolete) Revision History Approved Date From To Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Adding CFR 2.459 (obsolete) 1.0 2.0 August – 11 - 2008 Updated company template & Added text box (current) 2.0 3.0 Jan-31-2012 SCS-F19: Confidentiality Request Letter Page 2 of 2 Rev 3.0 Aura Light International AB December 25, 2014 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Subject: Permanent Confidentiality Request for FCC ID: 2ADVW-IQ4455MB We hereby request confidential treatment of information accompanying this application as outlined below: - Block Diagram - Schematics - Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Mikael Severinsson/ Quality Manager Aura Light International AB Address: Lumavagen 1, Karlskrona, Sweden Telephone: +46 45578626 Fax: +46 45526717 E-mail: [email protected]
December 25, 2014 To: SIEMIC, INC. 775 Montague Expressway, Milpitas, CA 95035 USA We, Aura Light International AB hereby declare LED Lamp (FCC ID: 2ADVW-IQ4455MB): Models IQ-4455MB, IQ-4455M are identical in driver aspect, and both models have the same RF module and antenna; the only difference is model IQ-4455MB has built-in Li-ion battery while model IQ-4455M has no built-in battery. Mikael Severinsson/ Quality Manager Aura Light International AB Address: Lumavagen 1, Karlskrona, Sweden Telephone: +46 45578626 Fax: +46 45526717 E-mail: [email protected]
External photos: ---The End---
Internal photos: ---The End---
TRF NO: FCC 15.249/A Page 1 of 25 Report No.: ES141231426E ELECTROMAGNETIC EMISSIONS COMPLIANCE REPORT INTENTIONAL RADIATOR CERTIFICATION TO FCC PART 15 SUBPART B &C REQUIREMENT OF LED Lamp MODEL No.: IQ-4455MB, IQ-4455M FCC ID: 2ADVW-IQ4455MB REPORT NO: ES141231426E ISSUE DATE: December 31, 2014 Prepared for AURA LIGHT INTERNATIONAL AB Lumavagen 1, Karlskrona, Sweden Prepared by SHENZHEN EMTEK CO., LTD. Building 69, Majialong Industry Zone, Nanshan District, Shenzhen, Guangdong, China Tel: +86-755-26954280 Fax: +86-755-26954282 TRF NO: FCC 15.249/A Page 3 of 25 Report No.: ES141231426E TABLE OF CONTENTS 1. GENERAL INFORMATION ........................................................................................................... 4 1.1. Product Description...................................................................................................................... 4 1.2. Related Submittal(s) / Grant (s) ................................................................................................... 4 1.3. Test Methodology ........................................................................................................................ 4 1.4. Special Accessories ...................................................................................................................... 4 1.5. Equipment Modifications ............................................................................................................. 4 1.6. Test Facility .................................................................................................................................. 5 1.7. Measurement Uncertainty ............................................................................................................ 5 2. SYSTEM TEST CONFIGURATION ............................................................................................. 6 2.1. EUT Configuration ...................................................................................................................... 6 2.2. EUT Exercise ............................................................................................................................... 6 2.3. Requirement for Compliance ....................................................................................................... 6 2.4. Configuration of Tested System ................................................................................................... 8 2.5. Description of support units ......................................................................................................... 8 3. SUMMARY OF TEST RESULTS ................................................................................................... 9 4. DESCRIPTION OF TEST MODES ................................................................................................ 9 5. CONDUCTED EMISSIONS TEST .............................................................................................. 10 5.1. Measurement Procedure ............................................................................................................. 10 5.2. Measurement Equipment Used: ................................................................................................. 10 5.3. Measurement Equipment Used .................................................................................................. 10 5.4. Measurement Equipment Used .................................................................................................. 10 6. RADIATED EMISSION TEST ..................................................................................................... 15 6.1. Measurement Procedure ............................................................................................................. 15 6.2. Measurement Equipment Used: ................................................................................................. 15 6.3. Test SET-UP ............................................................................................................................... 16 6.4. Radiated Measurement Result ................................................................................................... 16 7. BAND EDGES MEASUREMENT ................................................................................................ 22 7.1. Standard Applicable ................................................................................................................... 22 7.2. Measurement Procedure ............................................................................................................. 22 7.3. Measurement Equipment ........................................................................................................... 22 7.4. Test Setup ................................................................................................................................... 22 7.5. Test Results ................................................................................................................................ 22 8. ANTENNA APPLICATION ........................................................................................................... 25 8.1. Standard Applicable ................................................................................................................... 25 8.2. Antenna Construction ................................................................................................................ 25 TRF NO: FCC 15.249/A Page 4 of 25 Report No.: ES141231426E 1. GENERAL INFORMATION 1.1. Product Description The EUT is a short range, lower power, Details of technical specification, refers to the description in follows: a. Operation Frequency: 5830.471MHz b. Number of Channel: 1 c. Antenna Designation: Permanently integrated antenna d. Modulation: Un-modulated Carrier e. Rated RF Output Power: -2.87dbm f. Power Supply: 120-277V/AC, 60Hz 1.2. Related Submittal(s) / Grant (s) This submittal(s) (test report) is intended for F…
Text truncated - open the document above for the full version.
Radiated 30M~1000MHz: Above 1000MHz: Conducted: ---The End---
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 5.83 GHz - 5.83 GHz | - |