Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
9900 3 4 11 10 9 8 12 5 6 7 1 2 1 English 5 Español 43 Français (Canada) 85 English 5 English Congratulations on your new Next-Generation Philips Sonicare power toothbrush! Superior plaque removal, whiter teeth, and healthier gums are at your fingertips. Using Sonicare’s combination of gentle sonic technology and clinically developed and proven features, you can be confident that you’re getting the very best clean, every time. Welcome to the Philips Sonicare family! IMPORTANT SAFETY INSTRUCTIONS Only use the product for its intended purpose. Read this information carefully before you use the product and its batteries and accessories, and save it for future reference. Misuse can lead to hazards or serious injuries. WARNINGS -Keep the charging cables, charging travel cases, and wall adapters away from water. -After cleaning, make sure charging cables, charging travel cases, and wall adapters are completely dry before connecting to power. -This appliance can be used by children and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Cleaning and user maintenance shall not be made by children without supervision. -Children should be supervised to ensure that they do not play with the product. -Do not clean any part of the product in the dishwasher unless otherwise instructed in the Cleaning section. -Do not use charging cables, charging travel cases, and wall adapters outdoors or near heated surfaces. -Only use original Philips accessories or consumables, If supplied, only use the original USB cable, USB power supply unit, or non-USB power supply unit. -If the charging cable, charging travel cases or wall adapters is damaged, stop using it. -Replace the brush head every 3 months or sooner if signs of wear appear. Stop using a brush head with crushed or bent bristles. -The maximum altitude of use is 4500 meters. -Rinse the handle, especially the brush head connection. Gently clean around the rubber seal. -Make sure brush head and toothbrush are dry before storing in travel case. -Avoid direct contact with products that contain essential oils or coconut oil. Contact may result in bristles dislodging. 6 English -This appliance contains no user-serviceable parts. If the appliance is damaged, stop using it and contact the Consumer Care Center in your country. -The Real Time Coverage feature is intended to support your full-mouth brushing. Users are advised to refrain from brushing beyond the touch-up session to avoid overbrushing. Always follow the advice of a Dental Professional. -This appliance has only been designed for cleaning teeth and gums. MEDICAL WARNINGS -Stop using the appliance and consult your dentist/doctor if excessive or prolonged bleeding occurs after use, or if you experience discomfort or pain during use. -If you have a pacemaker or other implanted device, contact your doctor or the manufacturer of the implanted device prior to use. -This appliance is a personal care device and is not intended for use on multiple patients in a dental practice or institution. BATTERY SAFETY INSTRUCTIONS -This appliance contains non-replaceable batteries that are only to be removed by skilled persons. -Accessories supplied may vary for different products. -Only use original Philips accessories and consumables. -Charge only with Philips WAA1001 or WAA2001, and HYTCxx or CBA62xx. For the list of approved adapters, please see philips.com/support. -Keep product and batteries away from fire and do not expose them to direct sunlight or high temperatures. -If the product becomes abnormally hot or smelly, changes color or if charging takes longer than usual, stop using and charging the product and contact Philips. -Do not place products and their batteries in microwave ovens or on induction cookers. -Do not open, modify, pierce, damage or dismantle the product or battery to prevent batteries from heating up or releasing toxic or hazardous substances. Do not short-circuit, overcharge or reverse charge batteries. -This appliance contains batteries that are non-replaceable. When the battery is at end of life, the appliance shall be properly disposed of, see section on Recycling. -Charge and use the product at a temperature between 0 °C and 40 °C (32 °F and 104 °F). 7 English -If batteries are damaged or leaking, avoid contact with the skin or eyes. If this occurs, immediately rinse well with water and seek medical care. -When you handle batteries, make sure that your hands, the product and the batteries are dry. -To avoid accidental short-circuiting of batteries after removal, do not let battery terminals come into contact with metal object (e.g. coins, hairpins, rings). Do not wrap batteries in aluminum foil. Tape battery terminals or put batteries in a plastic bag before you discard them. -This appliance contains a Lithium-ion rechargeable cell. MUST BE RECYCLED OR DISPOSED OF PROPERLY. -The built-in rechargeable battery must be removed by a qualified professional when the product is discarded. Instructions for removal of built-in rechargeable batteries can be found on www.philips.com/support. Storage and transportation conditions Temperature (Transport and Storage) between -20°C to 60°C (-4°F and 140 °F) Electromagnetic fields (EMF) This Philips appliance complies with all applicable standards and regulations regarding exposure to electromagnetic fields. FCC Compliance Changes or modifications not expressly approved by Philips could void the user's FCC authorization to operate the toothbrush. This device complies with Part 15 of FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits fo…
Text truncated - open the document above for the full version.
Form: RFT-AMER-TCB-OP-19o Revision: 1 Page 1 of 1 Date: 1/25/2023 Attention: Application Examiner Re: Certification designating a U.S. agent for service of process pursuant to 47 CFR part §2.911(d)(7) of the FCC rules To whom it may concern, This letter is to certify that Philips Oral Healthcare, LLC (“Applicant”) accepts responsibilities to act as its own agent pursuant to 47 CFR part §2.911(d)(7) of the FCC rules for service of process. I consent to the obligation to accept service of process on behalf of the applicant in regard to the FCC ID designated below. I HEREBY CERTIFY THAT I am authorized to make the representations above on behalf of the Applicant. I further acknowledge the requirement to maintain an agent extends for no less than one year after the termination of all marketing and importation or the conclusion of and commission-related proceeding involving the equipment and agree to immediately notify the FCC and Intertek if there is any change in the status identified above. Applicant Company Name : Philips Oral Healthcare, LLC Contact Name : Matthew Vasa Address : 22100 Bothell Everett Hwy, Bothell, WA, 98021-3003 Telephone No : 425-482-8367 Email : [email protected] FCC ID : 2ADZNHX988 Applicant FRN : 0024216830 Signature: ____________________________________ Date: 2026-04-01 Matt Vasa Electronically signed by: Matt Vasa Reason: "I Approve" Date: Apr 1, 2026 10:17:32 PDT Intertek-FCC-Applicant-as-Agent-Attestation - Mykonos Final Audit Report2026-04-01 Created:2026-04-01 By:Patrick Erickson ([email protected]) Status:Signed Transaction ID:CBJCHBCAABAADxHNGV6ftlUW-YjWYQB_wN2e7seKRp9O "Intertek-FCC-Applicant-as-Agent-Attestation - Mykonos" History Document created by Patrick Erickson ([email protected]) 2026-04-01 - 5:07:44 PM GMT- IP address: 146.112.55.206 Document emailed to Matt Vasa ([email protected]) for signature 2026-04-01 - 5:09:00 PM GMT Email viewed by Matt Vasa ([email protected]) 2026-04-01 - 5:17:10 PM GMT- IP address: 52.102.18.21 Agreement viewed by Matt Vasa ([email protected]) 2026-04-01 - 5:17:12 PM GMT- IP address: 146.112.55.70 Document e-signed by Matt Vasa ([email protected]) Signing reason: "I Approve" Signature Date: 2026-04-01 - 5:17:32 PM GMT - Time Source: server- IP address: 146.112.247.251 Agreement completed. 2026-04-01 - 5:17:32 PM GMT
Form: RFT-AMER-TCB-OP-19n Revision: 1 Page 1 of 1 Date: 1/25/2023 Attention: Application Examiner Re: Covered List, located at https://www.fcc.gov/supplychain/coveredlist and 47 CFR parts §2.903 and §2.911(d)(5)(ii) of the FCC rules Applicant: Philips Oral Healthcare, LLC FCC ID: 2ADZNHX988 To whom it may concern, Philips Oral Healthcare LLC (“Applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to 47 CFR part §2.903 of the FCC rules and does not originate directly or indirectly from any company named on the covered list located in the link above or any subsidiary or affiliate thereof. Applicant further certifies that, as of the date of the filing of the application, the Applicant is not identified on the Covered List as an entity producing “covered” equipment and is not a subsidiary or affiliate of any such entity pursuant to 47 CFR part §1.50002 and required by 47 CFR part §2.911(d)(5)(ii) of the FCC rules. Applicant further certifies that no Cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software is installed in the equipment being certified. I HEREBY CERTIFY THAT I am authorized to make the representations above on behalf of the Applicant and agree to immediately notify Intertek if there is any change in the status identified above. Matthew Vasa Team Lead Regulatory Compliance Philips Oral Healthcare, LLC 2026-04-01 Matt Vasa Electronically signed by: Matt Vasa Reason: "I Approve" Date: Apr 1, 2026 14:07:54 PDT Intertek-FCC-Covered-List-Attestation - Mykonos Final Audit Report2026-04-01 Created:2026-04-01 By:Patrick Erickson ([email protected]) Status:Signed Transaction ID:CBJCHBCAABAAiZf1mpXo_20J6JcPW3A13X-vVycBxsgc "Intertek-FCC-Covered-List-Attestation - Mykonos" History Document created by Patrick Erickson ([email protected]) 2026-04-01 - 8:59:15 PM GMT- IP address: 146.112.55.4 Document emailed to Matt Vasa ([email protected]) for signature 2026-04-01 - 8:59:39 PM GMT Email viewed by Matt Vasa ([email protected]) 2026-04-01 - 9:02:50 PM GMT- IP address: 52.102.17.69 Agreement viewed by Matt Vasa ([email protected]) 2026-04-01 - 9:02:51 PM GMT- IP address: 146.112.55.234 Document e-signed by Matt Vasa ([email protected]) Signing reason: "I Approve" Signature Date: 2026-04-01 - 9:07:54 PM GMT - Time Source: server- IP address: 146.112.55.17 Agreement completed. 2026-04-01 - 9:07:54 PM GMT
Attention: Application Examiner 2026-04-01 Re: Request for confidentiality Applicant: Philips Oral Healthcare, LLC FCC ID: 2ADZNHX988 To whom it may concern, Permanent Confidentiality Request is hereby submitted by Philips Oral Healthcare, LLC to withhold permanently from public review certain portions of the application for equipment certification for the referenced FCC identifiers. This request for confidentiality is made pursuant to 47 CFR 0.457(d) and 0.459 of the FCC Rules. In particular, the following sections of the application are to be kept permanently confidential: • Schematics • Detailed Block diagrams • Detailed Operational/Functional Description Rationale for request for confidentiality: Philips Oral Healthcare, LLC has invested considerable time and materials in research and development to produce the referenced product. Disclosure of the permanently confidential portions of this application to competitors would not only give them significant competitive advantages in developing similar products, but would also disclose successful implementation of unpublished, leading edge technology developed by us. The fee for confidentiality has been submitted along with the fee for certification. If you have questions or need further information, please contact the undersigned. Sincerely, Matthew Vasa Team Leader Regulatory Compliance Philips Oral Healthcare, LLC Matt Vasa Electronically signed by: Matt Vasa Reason: "I Approve" Date: Apr 1, 2026 10:27:44 PDT Intertek-FCC-Confidentiality-Request-Letter - Mykonos Final Audit Report2026-04-01 Created:2026-04-01 By:Patrick Erickson ([email protected]) Status:Signed Transaction ID:CBJCHBCAABAA_5xbuiU7Xg2hy0O_ux_YUCaFZT6nu129 "Intertek-FCC-Confidentiality-Request-Letter - Mykonos" History Document created by Patrick Erickson ([email protected]) 2026-04-01 - 5:26:23 PM GMT- IP address: 146.112.55.114 Document emailed to Matt Vasa ([email protected]) for signature 2026-04-01 - 5:26:53 PM GMT Email viewed by Matt Vasa ([email protected]) 2026-04-01 - 5:27:22 PM GMT- IP address: 52.102.16.181 Agreement viewed by Matt Vasa ([email protected]) 2026-04-01 - 5:27:23 PM GMT- IP address: 146.112.55.219 Document e-signed by Matt Vasa ([email protected]) Signing reason: "I Approve" Signature Date: 2026-04-01 - 5:27:44 PM GMT - Time Source: server- IP address: 146.112.55.236 Agreement completed. 2026-04-01 - 5:27:44 PM GMT
IC:20109-HX988 HX855B IC:20109-HX988 HX855G IC:20109-HX988 HX855L IC:20109-HX988 HX855P IC:20109-HX988 HX855W IC:20109-HX988 HX856B IC:20109-HX988 HX856G IC:20109-HX988 HX856L IC:20109-HX988 HX856P IC:20109-HX988 HX856W IC:20109-HX988 HX987L IC:20109-HX988 HX987W IC:20109-HX988 HX988B IC:20109-HX988 HX988M IC:20109-HX988 HX988W
*** Confidential *** THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION THAT IS THE SOLE PROPERTY OF PHILIPS. DISTRIBUTION, REPRODUCTION OR USE BY OTHERS IS NOT PERMITTED WITHOUT THE WRITTEN PERMISSION OF PHILIPS. 2026 PHILIPS ELECTRONICS NORTH AMERICA CORPORATION DESCRIPTION: ARTWORK_ENDCAP_MYKONOS_US/CA_COO-CN PREPARED: DATE: SIZE: N/A DOCUMENT NO: NOISREV MLP APPROVED: DATE: DMR GROUP NUMBER: SHEET: 1 OF 1 SCALE 3:1 GREEN=SCR TBD US,CA HX988B
Philips Oral Healthcare LLC RF Exposure Exemption Report SCOPE OF WORK RF Exposure Exemption Evaluation – Rechargeable Electric Toothbrush Handle, Model: HX856W and HX856B REPORT NUMBER 106398251MPK-014 ISSUE DATE February 24, 2026 REVISED DATE April 21, 2026 PAGES 15 DOCUMENT CONTROL NUMBER Non-Specific Radio Report Shell Rev. December 2017 © 2017 INTERTEK Non-Specific Radio Report Shell Rev. December 2017 Page 2 of 15 EMC Report for Philips Oral Healthcare LLC on the Rechargeable Electric Toothbrush Handle, model HX856W and HX856B RF Exposure Exemption Evaluation Report Report Number: 106398251MPK-014 Project Number: G106398251 Report Issue Date: February 24, 2026 Revision Date: April 21, 2026 Product Designation: Model: Rechargeable Electric Toothbrush Handle HX856W and HX856B Standards: 47CFR 1.1307(b)(3) RSS-102 Issue 6 for Philips Oral Healthcare LLC Tested by: Client: Intertek 1365 Adams Court Menlo Park, CA 94025 USA Philips Oral Healthcare LLC 22100 Bothell Everett Highway Bothell, WA 98021 USA Report prepared by: Report reviewed by: Arjun Mukherjea / EMC Engineer Aaron Chang / EMC Team Leader This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Report Number: 106398251MPK-014 Issued: February 24, 2026 Non-Specific Radio Report Shell Rev. December 2017 Page 3 of 15 EMC Report for Philips Oral Healthcare LLC on the Rechargeable Electric Toothbrush Handle, model HX856W and HX856B Table of Contents Philips Oral Healthcare LLC ........................................................................................................................................ 1 1 Introduction and Conclusion ..................................................................................................................... 4 2 Evaluation Summary ................................................................................................................................ 4 3 Client Information .................................................................................................................................... 4 4 Description of Equipment Under Test and Variant Models ......................................................................... 5 5 RF Exposure Exemption Evaluation (FCC) ................................................................................................... 7 6 RF Exposure Exemption Evaluation (ISED)................................................................................................ 10 7 Revision History ..................................................................................................................................... 15 Intertek Report Number: 106398251MPK-014 Issued: February 24, 2026 Non-Specific Radio Report Shell Rev. December 2017 Page 4 of 15 EMC Report for Philips Oral Healthcare LLC on the Rechargeable Electric Toothbrush Handle, model HX856W and HX856B 1 Introduction and Conclusion The evaluation indicated in section 2.0 were performed on the product constructed as described in section 4.0. The remaining sections are the verbatim text from the actual evaluation during the investigation. These sections include the evaluation name, the specified Method, and Results. No additions, deviations, or exclusions have been made from the standard(s) unless specifically noted. Based on the results of our investigation, we have concluded the product evaluated complies with the requirements of the standard(s) indicated. The results obtained in this report pertain only to the item(s) evaluated. Intertek does not make any claims of compliance for samples or variants which were not evaluated. 2 Evaluation Summary Section Test full name Result 3 Client Information - 4 Description of Equipment Under Evaluation and Variant Models - 5 FCC SAR Test Exclusion Compliant 6 ISED Canada SAR Test Exclusion Compliant 7 Revision History - 3 Client Information This EUT was evaluated at the request of: Client: Philips Oral Healthcare LLC 22100 Bothell Everett Highway Bothell, WA 98021 USA Contact: Patrick Erickson Telephone: 1 (425) 487-7000 Email: [email protected] Intertek Report Number: 106398251MPK-014 Issued: February 24, 2026 Non-Specific Radio Report Shell Rev. December 2017 Page 5 of 15 EMC Report for Philips Oral Healthcare LLC on the Rechargeable Electric Toothbrush Handle, model HX856W and HX856B 4 Description of Equipment Under Test and Variant Models 4.1 Description of Equipment Under Test (provided by client) Philips Oral Healthcare LLC supplied the following description of the EUT: The Philips HX856W and HX856B are rechargeable electric toothbrushes that is inductively charged. Bluetooth connectivity allows the toothbrush to be connected to an app which provides real-time guidance on pressure, motion, position, duration and frequency of brushing. The toothbrush also tracks the brush head usage through RFID to alert the user when the heads need to be replaced. Intertek Report Number: 106398251MPK-014 Issued: February 24, 2026 Non-Specific Radio Report Shell Rev. December 2017 Page 6 of 15 EMC Report for Philips Oral Healthcare LLC on the Rechargeable Electric Toothbrush Handle, …
Text truncated - open the document above for the full version.
Sunlord Specifications for Chip Antenna Page 1 of 8 Preliminary [ New Released, Revised] SPEC No.: SLDA01170000 Shenzhen Sunlord Electronics Co., Ltd. Customer Product Name Chip Antenna Sunlord Part Number SLDA31-2R400G-S2TF Customer Part Number Approved By Checked By Issued By 【For Customer approval Only】 Date: Qualification Status: Full Restricted Rejected Approved By Verified By Re-checked By Checked By Comments: 【This SPEC is total 8 pages including specifications and appendix.】 【ROHS Compliant Parts】 Address: Sunlord Industrial Park, Dafuyuan Industrial Zone, Baoan, Shenzhen, China 518110 Tel: 0086-755-29832660 Fax: 0086-755-82269029 E-Mail: [email protected] SPECIFICATIONS Sunlord Specifications for Chip Antenna Page 2 of 8 【Version change history】 Rev. Effective Date Changed Contents Change reasons Approved By 01 / New Release / Hai Guo Sunlord Specifications for Chip Antenna Page 3 of 8 1. Scope This specification applies to SLDA31-2R400G-S2TF of Multi-layer Chip Antenna. 2. Product Description and Identification (Part Number) 1) Description :Multi-layer Chip Antenna 2) Product Identification (Part Number) SLDA 31 -2R400G -S2 T F ① ② ③ ④ ⑤⑥ 3. Electrical Characteristics Band Width Peak Gain Average Gain VSWR Impedance Power Capacity Part Number MHz In BW Ω W SLDA31-2R400G-S2TF ≥100 2.5 dBi @( XZ-total) 0.5 dBi @( XZ-total) < 2 50 2 W max 1) Operating and storage temperature range (individual chip without packing): -40 ~ +85°C°C. 2) Storage temperature range (packaging conditions): -10 ~ +40 and RH 70% (Max.).°C°C 3) Test equipment: Network Analyzer: E5071C. 4) Measuring diagram. 4. Shape and Dimensions Dimensions and recommended PCB pattern for reflow soldering: A B D C (1) (2) Unit: mm Item A B C D. SLDA31 3.2±0.21.6±0.20.5±0.10.5±0.2 ① Type SLDA Multilayer Chip Antenna ④ Series Code S2 ② External Dimensions (L×W) (mm) 31 3.2×1.6 ③ Center Frequency 2R400G 2400.0MHz ⑤ Packing T Tape Carrier Package ⑥ Hazardous Substance Free Products F Sunlord Specifications for Chip Antenna Page 4 of 8 Demo‐board: To p view Detail view Bottom view 1) Terminal Configuration: 5. Test and Measurement Procedures 5.1 Test Conditions No. Terminal Name No. Terminal Name (1) Feeding Point (2) Soldering terminal (2) (1) 50Ω trace GND via Unit: mm Sunlord Specifications for Chip Antenna Page 5 of 8 Unless otherwise specified, the standard atmospheric conditions for measurement/test as: a. Ambient Temperature: 20±15°C b. Relative Humidity: 65±20% c. Air Pressure: 86 Pa to 106KPa If any doubt on the results, measurements/tests should be made within the following limits: a. Ambient Temperature: 20±2°C b. Relative Humidity: 65±5% c. Air Pressure: 86KPa to 106KPa 5.2 Visual Examination a. Inspection Equipment: 20 X magnifier 5.3 Reliability Test Items Requirements Test Methods and Remarks 5.3.1 Terminal Strength No visible mechanical damage.① Solder the Antenna to the testing jig (glass epoxy board shown as the following figure) using leadfree solder. Then apply a force in the direction of the arrow. ② 10N force for 3216 series. ③ Keep time: 10±1sec. No visible mechanical damage.① Solder the chip to the test jig (glass epoxy board) using a leadfree solder. Then apply a force in the direction shown as the following figure. Solder the chip to the test jig (glass epoxy board) using leadfree solder. Then apply a force in the direction. ② Flexure: 2mm ③ Pressurizing Speed: 0.5mm/sec ④ Keep time: ≥30 sec 5.3.2 Resistance to Flexure 5.3.3 Dropping No visible mechanical damage.SLDA series: Drop the chip 5 times on a wood floor from a height of 50 cm. 5.3.4 Solderability ① No visible mechanical damage. ② Wetting shall be exceeded 75% coverage. ① Solder temperature: 240±2°C ② Duration: 3sec ③ Solder: Sn/3.0Ag/0.5Cu ④ Flux: 25% Resin and 75% ethanol in weight 5.3.5 Resistance to Soldering Heat No visible mechanical damage.① Solder temperature: 260±5°C ② Duration: 5 sec ③ Solder: Sn/3.0Ag/0.5Cu ④ Flux: 25% Resin and 75% ethanol in weight ⑤ The chip shall be stabilized at normal condition for 1~2 hours before measuring. 20 45 45 R10 Flexure: 2 10 Unit: mm 10N/10±1s Speed: 1.0mm/s Glass Epoxy Board Chip Mounting Pad Sunlord Specifications for Chip Antenna Page 6 of 8 5.3.6 Thermal Shock ① No visible mechanical damage. ② Satisfy electrical Characteristic. ① Temperature and time: -40 for 30±3 min→85 for °C°C 30±3min ② Transforming interval: Max. 20 sec. ③ Tested cycle: 10 cycles ④ The chip shall be stabilized at normal condition for 1~2 hours before measuring. 5.3.7 Damp Heat (Steady States) ① No visible mechanical damage. ② Satisfy electrical Characteristic. ① Temperature: 60±2°C ② Humidity: 90% to 95% RH ③ Duration: 96 +24 hours ④ The chip shall be stabilized at normal condition for 1~2 hours before measuring. 5.3.8 Resistance to High temperature ① No visible mechanical damage. ② Satisfy electrical Characteristic. ① Temperature: 85±2°C ② Duration: 96 +24 hours ③ The chip shall be stabilized at normal condition for 1~2 hours before measuring. 6. Packaging and Storage 6.1 Packaging There is one type of packaging for the Multi-layer Chip Antennas. Please specify the packing code when ordering. 6.1.1 Tape Carrier Packaging: Packaging code: T a. Tape carrier packaging are specified in attached figure Fig. 6.1-1~3 b. Tape carrier packaging quantity please see the following table: (1) Taping Drawings (Unit: mm) Type 3216[1206] Tape Paper Tape Quantity 3K -40°C Ambient Temperature 85°C 30 min. 30 min. 30 min. 20sec. (max.) Remark: The sprocket holes are to the right as the tape is pulled toward the user. Fig. 6.1-1 Sprocket Hole Chip Cavity Bottom Tape Paper Tape Top Tape Paper Tape Sunlord Specifications for Chip Antenna Page 7 of 8 (2) Taping Dimensions (Unit: mm) (3)Reel Dimensions (Unit: mm) 6.2 Storage a. The solderability of the external electrode may be deteriorated if packages are stored where they are exposed to high humidity. Package must be stored at 40 or less and 70% RH or less.°C b. The solderability of the exter…
Text truncated - open the document above for the full version.
EMC Report for Philips Oral Healthcare LLC on the Rechargeable Toothbrush Handle, model HX856W and HX856B File: 106398251MPK-001 Page 1 of 68 TEST REPORT Report Number: 106398251MPK-001 Project Number: G106398251 Issue Date: February 25, 2026 Revision Date: April 21, 2026 ISED Designation Number: US0039 Testing performed on Rechargeable Toothbrush Handle Model Number: HX856W and HX856B to FCC Part 15 Subpart C (15.247) ISED RSS-247 Issue 4 For Philips Oral Healthcare LLC Test Performed by: Test Authorized by: Intertek 1365 Adams Court Menlo Park, CA 94025 USA Philips Oral Healthcare LLC 22100 Bothell Everett Highway Bothell, WA 98021 USA Prepared by: Date: February 25, 2026 Arjun Mukherjea Reviewed by: Date: February 25, 2026 Aaron Chang This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. This report must not be used to claim product endorsement by A2LA, NIST nor any other agency of the U.S. Government. EMC Report for Philips Oral Healthcare LLC on the Rechargeable Toothbrush Handle, model HX856W and HX856B File: 106398251MPK-001 Page 2 of 68 Report No. 106398251MPK-001 Equipment Under Test: Rechargeable Toothbrush Handle Model Number: HX856W and HX856B Applicant: Philips Oral Healthcare LLC Contact: Patrick Erickson Address: Philips Oral Healthcare LLC 22100 Bothell Everett Highway Bothell, WA 98021 USA Country: USA Tel. Number: (425) 487-7000 Email: [email protected] Applicable Regulation: FCC Part 15 Subpart C (15.247) ISED RSS-247 Issue 4 Date of Test: January 27 – February 25, 2026 We attest to the accuracy of this report: Arjun Mukherjea EMC Engineer Aaron Chang EMC Team Leader EMC Report for Philips Oral Healthcare LLC on the Rechargeable Toothbrush Handle, model HX856W and HX856B File: 106398251MPK-001 Page 3 of 68 TABLE OF CONTENTS 1.0 Summary of Tests .......................................................................................................................... 4 2.0 General Information ...................................................................................................................... 5 2.1 Product Description ............................................................................................................ 5 2.2 Related Submittal(s) Grants ................................................................................................ 6 2.3 Test Facility ........................................................................................................................ 6 2.4 Test Methodology ............................................................................................................... 6 2.5 Measurement Uncertainty ................................................................................................... 6 3.0 System Test Configuration ......................................................................................…
Text truncated - open the document above for the full version.
22100 Bothell Everett Hwy · Bothell, Washington, 98021 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 436.00 µW |