FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. RV LIGHTING INC./
  3. 2AE2PMODEL-NO-WS-01

2AE2PMODEL-NO-WS-01Remote

RV LIGHTING INC.
Remote - FCC ID 2AE2PMODEL-NO-WS-01 - RV LIGHTING INC.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Sep 27, 2015
Application Purpose
Original Equipment
Date of Application
Sep 27, 2015
Equipment Note
Remote
Frequency Range
433.92000000 - 433.92000000
Company
RV LIGHTING INC.
Country
Canada

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

2 Thank you for purchasing our product. R217 series LED dimmer is designed to drive constant voltage LED products in voltage range of DC5V-24V. It contains a main control unit and a RF wireless remote controller. User can turn on/off or adjust LED brightness conveniently via the remote controller. 5. Power Supply The controller unit can work from DC 5V to 24V. The red power cable should be connected to power positive and black to negative. Please make sure the power supply voltage is same as the LED load and the power is capable for the load wattage. LED Dimmer User’s Manual R217 / R217-S RF Remote Operation Full Protection Multi Remote Option Waterproof Option Easy Remote Pairing Compact Design Introduction Installing 6. LED Output The controller unit supports constant voltage driving LED products. The red cable should be connected to LED positive and black cable to negative. The red cable is internal connected to power supply positive in controller unit. The controller unit has output overload protection function, please check whether the output is short circuit or over loaded if the controller stop working. 1 2 Functions 1. Turn on/off Press this key to switch on or off the controller. Press and hold this key will force to switch off the controller. The controller will memorize the on/off status and restore the on/off status and brightness level on each power on moment. 2. Increase Brightness Press this key to increase the output LED brightness. Press and hold this key will continuously increase the brightness. 4. Remote Controller Indicator This indicator will blink when remote controller works. Single Color Smooth Change Effect 7. Status Indicator This is a full color status indicator. It displays all working status of the controller. It indicates different events as following: Blue: normal working. Short single white flash: new command received. Long single yellow flash: reach brightness limit. Red flash: overload protected. Yellow flash: overheat protected. Operation 567 3 RM07 (Optional) 1 2 3 4 4 3. Decrease Brightness Press this key to decrease the output LED brightness. Press and hold this key will continuously decrease the brightness. When controller is off, hold press this key will turn on the controller and jump to minimum brightness. 5 8. Using Remote Please pull out the battery insulating tape before using. The remote controller use CR2032 cell battery, it can last for 2 years for regular usage. For proper receiving remote signal, please do not install the controller in closed metal parts. 9. Pairing New Remote The remote and main unit is 1 to 1 paired as default. Further more, one main unit can be paired to 5 remote controllers and every remote can be paired to any main unit. Please do following steps to pair a new remote: 1. Plug off the power of main unit and plug in again after more than 5 seconds. 2. Press remote ‘on/off’ and ‘decreasing brightness’ key together in 5 seconds after main unit powered on. After this operation, the controller’s indicator will flash white for 3 times to display the new remote is accepted. The latest paired 5 remote controllers can be recognized. 6 Advanced Features 11. Waterproof R217 model is standard version which can be used in dry environment. R217-S is a IP68 waterproof version, which can be used in wet environment or under water within depth of 30 meters. Note: The remote receiving sensitivity will decrease when controller installed in wet place or under water, please setup the controller when the main unit is dry. 12. Protection R217 series led dimmer has full protection function for output short circuit, overload, and overheat. The indicator will flash red at overload or short circuit protection and flash yellow at over heat. The controller will automatically recover from protection when working status is good. Please ensure the LED load is in rated range, not shorted and the controller unit is in a good heat dissipation environment to avoid protection. 10. Optional Wall Switch Remote The controller can also work with the optional wall switch type remote controller RM07. This remote controller has the same function and usage as the default hand hold remote controller. It can be sticked on the wall for fixed place operation. Specification Model R217 R217-S Brightness Grade7 levels PWM Grade256 levels Min. Brightness ShortcutYes On/off status memorizeYes Overload protectionYes Overheat protectionYes Working VoltageDC 5-24V Remote frequency 433.92MHz Remote control distance >15m at open area Rated Output Current 15A IP Grade IP-63 IP-68

Attestation Statements

Date: 2015-07-07 To: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD FCC ID: 2AE2PMODEL-NO-WS-01 To Whom It May Concern: This letter is to ascertain that RV LIGHTING inc. Product Remote has been the units used for conducting FCC compliance testing, the DoC part will be tested by FCC recognized test lab. If you have any question or concerns, pls. contact us. Sincerely, Client’s signature: Client’s name / title: FRANK GAUTHIER Contact information / address Address: 2327 VERSANT NORD SUITE 111, QUEBEC, quebec, G1N4C2, Canada E-mail: [email protected] Fax: (418) 5270657 Tel: (418) 614 3742

Cover Letter(s)

Differences Declaration To whom concern, We company RV LIGHTING inc. hereby declares: The product model(s): WSB-01, WSB-02, WS-02, WS-02dc, WSI-01, WS-01DC, WSI-02 is identical in the same PCB layout, interior structure and electrical circuits with the model WS-01 which tested in Shenzhen Huatongwei International Inspection Co., Ltd, the only differences are the model name for commercial purpose. Sincerely yours, Name: FRANK GAUTHIER Position: Company Address: 2327 VERSANT NORD SUITE 111, QUEBEC, quebec, G1N4C2, Canada Te l / F a x : (418) 614-3742 / (418) 527-0657 E-Mail: [email protected]

External Photos

Report No: TRE15060180 Page: 17 of 20 Issued: 2015-08-28 6. External and Internal Photos of the EUT External Photos Report No: TRE15060180 Page: 18 of 20 Issued: 2015-08-28

ID Label/Location Info

Label location

Internal Photos

Report No: TRE15060180 Page: 19 of 20 Issued: 2015-08-28 Internal Photos Report No: TRE15060180 Page: 20 of 20 Issued: 2015-08-28 .......................End of Report.........................

Test Report

The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. TEST REPORT Report Reference No. .................... : TRE15060180 R/C..........:80133 FCC ID ............................................. : 2AE2PMODEL-NO-WS-01 Applicant’s name ........................... : RV LIGHTING inc. Address ............................................ : 2327, Versant Nord Blvd, suite 111, Quebec, QC, Canada, G1N 4C2. Manufacturer......................................: Rayrun Technology CO., LTD Address...............................................: 3Floor Est, G building, HengChangRong XingHui Industry Park, HuaNing W Road, Dalang, Bao'an District, ShenZhen, China Test item description ..................... : Remote Trade Mark ....................................... : ECO-LED, ECO-DEL Model/Type reference ...................... : WS-01 Listed Model(s)................................. : WSB-01, WSB-02, WS-02, WS-02dc, WSI-01, WS-01DC, WSI-02 Standard .......................................... : FCC CFR Title 47 Part 15 Subpart C Section 15.231 Date of receipt of test sample...........: June 29, 2015 Date of testing..............................: June 29, 2015- Sep 2, 2015 Date of issue.................................: Sep 2, 2015 Result .................. ........................: PASS Compiled by ( position+printed name+signature) . : File administrators Shayne Zhu Supervised by ( position+printed name+signature) . : Project Engineer Cary Luo Approved by ( position+printed name+signature) . : RF Manager Hans Hu Testing Laboratory Name .............. : Shenzhen Huatongwei International Inspection Co., Ltd Address ............................................ : Keji Nan No.12 Road, Hi-tech Park, Shenzhen, China Shenzhen Huatongwei International Inspection Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen Huatongwei International Inspection Co., Ltd is acknowledged as copyright owner and source of the material. Shenzhen Huatongwei International Inspection Co., Ltd takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Report No: TRE15060180 Page: 2 of 20 Issued: 2015-08-28 Contents 1. TEST STANDARDS AND TEST DESCRIPTION 3 1.1. Test Standards 3 1.2. Test Description 3 2. SUMMARY 4 2.1. Client Information 4 2.2. Product Description 4 2.3. EUT operation mode 4 2.4. EUT configuration 4 2.5. Modifications 4 3. TEST ENVIRONMENT 5 3.1. Address of the test laboratory 5 3.2. Test Facility 5 3.3. Environmental conditions 6 3.4. Statement of the measurement uncertainty 6 3.5. Equipments Used during the Test 7 4. TEST CONDITIONS AND RESULTS 8 4.1. Antenna requirement 8 4.2. AC Power Conducted Emission(Not Applicable) 9 4.3. Radiated Emission 10 4.4. Occpied Bandwidth 14 4.5. Deactivation Time 15 5. TEST SETUP PHOTOS OF THE EUT 16 6. EXTERNAL AND INTERNAL PHOTOS OF THE EUT 17 Report No: TRE15060180 Page: 3 of 20 Issued: 2015-08-28 1. TEST STANDARDS AND TEST DESCRIPTION 1.1. Test Standards The tests were performed according to following standards: FCC Rules Part 15.231: Periodic operation in the band 40.66–40.70 MHz and above 70 MHz. ANSI C63.10-2009: American National Standard for Testing Unlicensed Wireless Devices. 1.2. Test Description Test Item Section in CFR 47 Result Conducted Emissions 15.207 N/A Unintentional Radiated Emissions 15.109 PASS Radiated & Spurious Emissions 15.205/15.209(a)/15.231(b/15.35(c)PASS Deactivation Time 15.231(a)(1) PASS Duty Cycle 15.231 PASS Occpied Bandwidth 15.231(c) PASS Remark: The measurement uncertainty is not included in the test result. Report No: TRE15060180 Page: 4 of 20 Issued: 2015-08-28 2. SUMMARY 2.1. Client Information Applicant: RV LIGHTING inc. Address: 2327, Versant Nord Blvd, suite 111, Quebec, QC, Canada, G1N 4C2 Manufacturer: Rayrun Technology CO., LTD Address: 3Floor Est, G building, HengChangRong XingHui Industry Park, HuaNing W Road, Dalang, Bao'an District, ShenZhen, China 2.2. Product Description Name of EUT Remote Trade Mark: ECO-LED, ECO-DEL Model No.: WS-01 Listed Model(s): WSB-01, WSB-02, WS-02, WS-02dc, WSI-01, WS-01DC, WSI-02 Power supply: DC3.0V from battery Adapter information: / Operation frequency: 433.92MHz Channel number: 1 Antenna type: Intergral Antenna Antenna gain: 0dBi 2.3. EUT operation mode The EUT has been tested under typical operating condition. The Applicant provides software to control the EUT for staying in continous transmitting mode for testing. 2.4. EUT configuration The following peripheral devices and interface cables were connected during the measurement: ● - supplied by the manufacturer ○ - supplied by the lab ○ Power Cable Length (m) : / Shield : / Detachable : / ○ Multimeter Manufacturer : / Model No. : / 2.5. Modifications No modifications were implemented to meet testing criteria. Report No: TRE15060180 Page: 5 of 20 Issued: 2015-08-28 3. TEST ENVIRONMENT 3.1. Address of the test laboratory Shenzhen Huatongwei International Inspection Co., Ltd. Keji Nan No.12 Road, Hi-tech Park, Shenzhen, China Phone: 86-755-26748019 Fax: 86-755-26748089 3.2. Test Facility The test facility is recognized, certified, or accredited by the following organizations: CNAS-Lab Code: L1225 Shenzhen Huatongwei International Inspection Co., Ltd. has been assessed and proved to be in compliance with CNAS-CL01 Accreditation Criteria for Testing and Calibration Laboratories (identical to ISO/IEC 17025: 2005 General Requirements) for the Competence of Testing and Calibration Laboratories, Date of Registration: February 28, 2015. Valid time is until February 27, 2018. A2LA-Lab Cert. No. 2243.01 Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory has been accredited by A2LA for technical competence in the field of electrical test…

Text truncated - open the document above for the full version.

Test Setup Photos

Report No: TRE15060180 Page: 16 of 20 Issued: 2015-08-28 5. Test Setup Photos of the EUT

Contact Information

Applicant

FRANK GAUTHIER(TECHNICIAN)
[email protected]4186143742Fax: 4185270657

Test Firm

Shenzhen Huatongwei International Insp. Co., LtdMoffy Yu
[email protected]86-755-26748078Fax: 86-755-26748089

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term