Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
SENSEON PLUS PROGRAMMING GUIDE TECHNICAL SPECIFICATIONS senseonsecure.com 2 SENSEON PLUS PROGRAMMING GUIDE TABLE OF CONTENTS 1. Card Types ........................................................................................................3 2. Card Organization Checklist ...........................................................................3 3. Before Programming.......................................................................................4 A. Programming Tips .......................................................................................4 B. Beep Indicators............................................................................................4 C. LED Color Indicators ...................................................................................4 4. System Set-Up ..................................................................................................4 5. Adding Cards ....................................................................................................4 A. New Administrator Cards ...........................................................................5 B. New User Cards ...........................................................................................5 6. Deleting Cards ..................................................................................................6 C. Deleting All User Cards ...............................................................................6 D. Deleting Individual User Cards ..................................................................6 E. Deleting a Lost/Stolen Card........................................................................6 7. System Adjustments........................................................................................7 F. Changing Between Auto-Relock + Manual Lock Mode ...........................7 G. Adjusting the Auto-Relock Time ................................................................7 H. Adjusting Sound Setting .............................................................................7 I. Adjusting Reader Light Control ...................................................................8 J. Adjusting Controller Light Control ..............................................................8 K. Removing the Admin Card .........................................................................8 8. System Reset .....................................................................................................9 9. Specifi cations ....................................................................................................9 PROGRAMMING GUIDE Programming Instructions & Technical Specifi cations 10. FCC Statement ................................................................................................10 SENSEON PLUS PROGRAMMING GUIDE 3 Administrator Cards have programming rights, but can't unlock cabinets, drawers and doors. At this access level, you can add or delete User Cards and make changes to operational setings. Master Admin Card is the primary card for your Senseon system. It is the fi rst card you will activate with your reader and the one that initiates the set up of other cards. User Cards can access secured cabinets but can't change any of your system's settings. Blank Cards can be programmed as either additional Administrator Cards or User Cards. MASTER ADMIN CARD Note: Each Proximity Reader can remember up to 1,000 Cards. Please mark or indicate the confi gured access type on a card after programming it. Card Organization Checklist Card Types Whether your Senseon Plus system includes a single Proximity Reader or multiple readers operating in a common area, the following steps are recommended before you begin programming. Identify and label the location of each Proximity Reader. Determine who will require Administrator Cards and for which Proximity Readers. Organize and label the Administrator Card(s) accordingly. Organize, and label the User Cards according to their corresponding Proximity Reader(s). Be sure to record all of this information for future reference in case any cards are lost or stolen. Note: We highly recommend that you Signal Test the Proximity Reader before fi nalizing its placements and depth within your cabinet. Your Proximity Reader is designed for two types of card access, Administrators and Users: 4 SENSEON PLUS PROGRAMMING GUIDE WAIT TAP TAPEXIT Before Programming Proximity Reader Beep Indicators Programming Tips Tap an Administrator Card to your reader the number of times required for each task. Positive Beep: The tone of the beep rises. Negative Beep: The tone of the beep falls. Wait 3 seconds and listen for the reader to beep the same number of times you tapped your Administrator Card. Tap the card for your programming task, if needed, and listen for the specifi ed number of beeps to signal programming success. Complete your task by tapping an Administrator Card or wait 15 seconds Note: 1. The number of taps and beeps will vary according to each task! 2. Listen for 2 initial beeps after the fi rst tapping of an Administrator Card. 3. Tap access cards as close as possible to your Proximity Reader. System Set-Up To set up your system for programming, make sure all systems components are properly connected, then plug in the Power Supply. When powered on, the Proximity Reader's LED light will turn blue. This means your system is ready for programming. SENSEON PLUS PROGRAMMING GUIDE 5 To add another Administrator Card, tap an additional Blank Card once. The Reader will beep twice to verify every new Administrator Card added. To add another User Card, tap an additional Blank Card once. You can program up to 1,000 User or Administrator Cards per Controller. Your Reader will beep to verify every User Card added. Note: If you attempt to add a User Card that is already programmed to the Proximity Reader, it will negative beep and the LED will fl ash red. Tap the Administrator Card 5 times at the designatedβ¦
Text truncated - open the document above for the full version.
Report No.: 1910RSU038-UE 1 of 4 EUT External Photograph (1) EUT Photo (Senseon Plus Reader) (2) EUT Photo (Senseon Plus Reader) Report No.: 1910RSU038-UE 2 of 4 (3) EUT Photo (Senseon Plus Reader) (4) EUT Photo (Senseon Plus Reader) Report No.: 1910RSU038-UE 3 of 4 (5) EUT Photo (Senseon Plus Reader) (6) EUT Photo (Senseon Plus Reader) Report No.: 1910RSU038-UE 4 of 4 (7) EUT Photo (Senseon Plus Reader) (8) EUT Photo (Senseon Plus Reader)
Label
Report No.: 1910RSU038-UE 1 of 3 EUT Internal Photograph (1) EUT Photo (Senseon Plus Reader) (2) EUT Photo (Senseon Plus Reader) Report No.: 1910RSU038-UE 2 of 3 (3) EUT Photo (Senseon Plus Reader) (4) EUT Photo (Senseon Plus Reader) Report No.: 1910RSU038-UE 3 of 3 (5) EUT Photo (Senseon Plus Reader) (6) EUT Photo (Senseon Plus Reader)
MRT Technology (Suzhou) Co., Ltd Report No.: 1910RSU038-U1 Phone: +86-512-66308358 Report Version: V01 Web: www.mrt-cert.com Issue Date: 06-24-2020 Page Number: 1 of 32 FCC ID: 2AEDR-SPLUSPR-1 APPLICANT: Accuride International Inc. Application Type: Certification Product Name: Senseon Plus System Model No.: SPLUSPR-1 Brand Name: Senseon FCC Classification: Part 15 Low Power Communication Device Transmitter (DXX) FCC Rule Part(s): Part 15 Subpart C (Section 15.225) Test Procedure(s): ANSI C63.10-2013 Test Date: October 22, 2019 ~ April 12, 2020 MEASUREMENT REPORT FCC PART 15.225 RFID 13.56MHz Reviewed By: ( Jame Yuan ) Approved By: ( Robin Wu ) The test results relate only to the samples tested. This equipment has been shown to be capable of compliance with the applicable technical standards as indicated in the measurement report and was tested in accordance with the measurement procedures specified in ANSI C63.10-2013. Test results reported herein relate only to the item(s) tested. The test report shall not be reproduced except in full without the written approval of MRT Technology (Suzhou) Co., Ltd. Report No.: 1910RSU038-U1 Page Number: 2 of 32 Revision History Report No. Version Description Issue Date Note 1910RSU038-U1 Rev. 01 Initial Report 06-24-2020 Valid Report No.: 1910RSU038-U1 Page Number: 3 of 32 CONTENTS Description Page 1. INTRODUCTION ..................................................................................................................... 6 1.1. Scope ........................................................................................................................... 6 1.2. MRT Test Location ....................................................................................................... 6 2. PRODUCT INFORMATION ..................................................................................................... 7 2.1. Equipment Description .................................................................................................. 7 2.2. Test Mode .................................................................................................................... 7 2.3. Device Capabilities ....................................................................................................... 7 2.4. EMI Suppression Device(s)/Modifications ..................................................................... 7 2.5. Labeling Requirements ................................................................................................. 8 3. DESCRIPTION OF TEST ........................................................................................................ 9 3.1. Evaluation Procedure ................................................................................................... 9 3.2. AC Line Conducted Emissions ..................................................................................... 9 3.3. Radiated Emissions .................................................................................................... 10 4. ANTENNA REQUIREMENTS ................................................................................................. 11 5. TEST EQUIPMENT CALIBRATION DATA ............................................................................ 12 6. MEASUREMENT UNCERTAINTY ......................................................................................... 13 7. TEST RESULT ...................................................................................................................... 14 7.1. Summary .................................................................................................................... 14 7.2. In-band Emission ........................................................................................................ 15 7.2.1. Test Limit ................................................................................................................ 15 7.2.2. Test Procedure Used .............................................................................................. 15 7.2.3. Test Setup ............................................................................................................... 16 7.2.4. Test Result .............................................................................................................. 17 7.3. Out-band Emission ..................................................................................................... 18 7.3.1. Test Limit ................................................................................................................ 18 7.3.2. Test Procedure Used .............................................................................................. 18 7.3.3. Test Setup ............................................................................................................... 19 7.3.4. Test Result .............................................................................................................. 20 7.4. 20dB Bandwidth & 99% Bandwidth ............................................................................. 21 7.4.1. Test Limit ................................................................................................................ 21 7.4.2. Test Procedure Used .............................................................................................. 21 7.4.3. Test Setting ............................................................................................................. 21 7.4.4. Test Setup ............................................................................................................... 22 Report No.: 1910RSU038-U1 Page Number: 4 of 32 7.4.5. Test Result .............................................................................................................. 23 7.5. Frequency Tolerence .................................................................................................. 24 7.5.1. Test Limit ..................................................................β¦
Text truncated - open the document above for the full version.
Report No.: 1910RSU038-UT 1 of 2 FCC Part 15C Test Setup Photograph Description: Front View of Conducted Emission Test Setup for Power Port Description: Back View of Conducted Emission Test Setup for Power Port Report No.: 1910RSU038-UT 2 of 2 Description: Radiated Emission Test Setup for below 30MHz Description: Radiated Emission Test Setup for above 30MHz
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 13.56 MHz - 13.56 MHz | - |

FridgiGuard
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Stand-Alone Proximity Reader
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz