Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Soap Studio Company Limited Date: 25 March 2015 Federal Communications Commission Authorization and Evaluation Division FCC ID: 2AEFH-SSRC001 Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, the Applicant hereby requests confidential treatment of information accompanying this application as outlined below: 1. Block diagram 2. Schematics 3. Operation Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might to harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Rule 0.457, disclosure of this application and all accompanying documentation will not be made before the date of the grant for this application. Title: Managing Director Company name: Soap studio Company Limited Tel.:+852-2771-4388 Fax:+852-2771-9368
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 4 Report Version 1 Reference No.: 150326N014-1 PHOTOGRAPHS OF THE EUT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 4 Report Version 1 Reference No.: 150326N014-1 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 4 Report Version 1 Reference No.: 150326N014-1 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 4 Report Version 1 Reference No.: 150326N014-1
Made in China
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 4 Report Version 1 Reference No.: 150326N014-1 PHOTOGRAPHS OF THE EUT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 4 Report Version 1 Reference No.: 150326N014-1 ANT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 4 Report Version 1 Reference No.: 150326N014-1 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 4 Report Version 1 Reference No.: 150326N014-1
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 28 Report Version 1 Test Report No.: RF150326N014-1 TEST REPORT Applicant Soap Studio Company Limited Address Rm 1302, 13/F, Tai Sang Bank Building, 130-132 Des Voeux Road, Central, Hong Kong Manufacturer or Supplier Soap Studio Company Limited Address Rm 1302, 13/F, Tai Sang Bank Building, 130-132 Des Voeux Road, Central, Hong Kong Product Dark Knight Tumbler RC 1:12 Scale vehicle Brand Name Soap Studio Model SSRC-001 Additional Model & Model Difference N/A Date of tests Mar. 26, 2015 ~ Apr. 23, 2015 the tests have been carried out according to the requirements of the following standard: FCC Part 15, Subpart C, Section 15.249 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Tested by Heise Chen Project Engineer / EMC Department Approved by Glyn He Supervisor / EMC Department Date: Apr. 23, 2015 This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 28 Report Version 1 Test Report No.: RF150326N014-1 TABLE OF CONTENTS RELEASE CONTROL RECORD ............................................................................................................ 4 1 SUMMARY OF TEST RESULTS .................................................................................................... 5 2 MEASUREMENT UNCERTAINTY ................................................................................................. 5 3 GENERAL INFORMATION ............................................................................................................ 6 3.1 GENERAL DESCRIPTION OF EUT ............................................................................................... 6 3.2 DESCRIPTION OF TEST MODES ................................................................................................. 7 3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS ................................................................ 8 3.4 DESCRIPTION OF SUPPORT UNITS ........................................................................................... 8 4. TEST TYPES AND RESULTS ........................................................................................................ 9 4.1 CONDUCTED EMISSION MEASUREMENT ................................................................................. 9 4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT ................................................. 9 4.1.2 TEST INSTRUMENTS ....................................................................................................... 9 4.1.3 TEST PROCEDURES ..................................................................................................... 10 4.1.4 DEVIATION FROM TEST STANDARD ........................................................................... 10 4.1.5 TEST SETUP .................................................................................................................... 11 4.1.6 EUT OPERATING CONDITIONS ..................................................................................... 11 4.1.7 TEST RESULTS .............................................................................................................. 12 4.2 RADIATED EMISSION MEASUREMENT .................................................................................... 14 4.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT .................................................... 14 4.2.2 TEST INSTRUMENTS ..................................................................................................... 15 4.2.3 TEST PROCEDURES ..................................................................................................... 16 4.2.4 DEVIATION FROM TEST STANDARD ........................................................................... 16 4.2.5 TEST SETUP ................................................................................................................... 17 4.2.6 EUT OPERATING CONDITIONS .................................................................................... 17 4.2.7 TEST RESULTS .............................................................................................................. 18 4.3 20dB BANDWIDTH MEASUREMENT ......................................................................................... 23 4.3.1 LIMITS OF 20dB BANDWIDTH MEASUREMENT ............................................................…
Text truncated - open the document above for the full version.
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 3 Report Version 1 Reference No.: 150326N014-1 SET-UP FOR CONDUCTED EMISSION TEST Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 3 Report Version 1 Reference No.: 150326N014-1 SET-UP FOR RADIATED EMISSION TEST Frequency Range< 30MHz~1GHz > Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 3 Report Version 1 Reference No.: 150326N014-1 Frequency Range< Above 1GHz >
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | - |

Dark Knight Tumbler RC One Twelfth Scale vehicle
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Dark Knight Tumbler RC One Twelfth Scale vehicle
Equipment Class
DTS - Digital Transmission System