FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. SENSEOR/
  3. 2AEGUHTR01-2AW

2AEGUHTR01-2AWTransceiver for SAW sensors

SENSEOR
Transceiver for SAW sensors - FCC ID 2AEGUHTR01-2AW - SENSEOR
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Jul 08, 2015
Application Purpose
Original Equipment
Date of Application
Jul 08, 2015
Equipment Note
Transceiver for SAW sensors
Frequency Range
430.00000000 - 450.00000000
Company
SENSEOR
Country
France

Documents & Files

Select a file to view

Users Manual

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Operational Description

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

www.senseor.com SENSeOR SAS capital 44 082,25€ RCS Grasse 488 576 430 – APE 7120B 505, route des Lucioles – Navigator B – 06560 Valbonne Sophia Antipolis – France SIRET: 488 576 430 00042 Tel: +33(0)4 97 23 13 20 – Fax: +33(0)4 93 06 08 58 TVA/VAT: FR35 488 576 430 TEMPERATURE MONITORING SYSTEM TS6 INSTALLATION GUIDE April 2015 SENSeOR www.senseor.com 2/16 SENSeOR SAS Content Content .................................................................................................................................................... 2 Important notes ...................................................................................................................................... 3 1. Regulations (Radio-Frequency – Security – EMC) ....................................................................... 3 2. Safety Instructions ....................................................................................................................... 4 3. Installation instructions ............................................................................................................... 4 System content ........................................................................................................................................ 5 System installation .................................................................................................................................. 6 1. Equipment list .............................................................................................................................. 6 2. Sensor installation ....................................................................................................................... 6 3. Antenna installation .................................................................................................................... 7 4. Transceiver installation ............................................................................................................... 8 System commissioning .......................................................................................................................... 10 1. First installation ......................................................................................................................... 10 2. System options .......................................................................................................................... 10 a. Local programmable alarm ................................................................................................... 10 b. Analog output (option) .......................................................................................................... 10 Optimize your measurements! ............................................................................................................. 11 1. Optimize the use of the sensor ................................................................................................. 11 2. Minimize the temperature gradient (measured part/sensor) .................................................. 12 Notes ..................................................................................................................................................... 13 www.senseor.com 3/16 SENSeOR SAS Important notes This system is designed for professional use. Therefore SENSeOR will not carry any responsibility or liability for direct and consequential damages resulting from the use of it. Carefully observe all safety and installation instructions below. Install and operate this equipment only if it is in perfect condition and only in accordance with this manual. Do not use the equipment if it is damaged. SENSeOR will refuse any liability for direct and consequential damages resulting from unauthorized modifications to any of the components of this system. No part of this manual may be reproduced in any way without written authorization from SENSeOR. This manual is subject to change with prior notice. 1. Regulations (Radio-Frequency – Security – EMC) This device is certified/has been granted approval per:  FCC - PART 15.231-C (e) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  IC - RSS‐Gen (4)/RSS‐210 (8) This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.  Security: CEI 61010-1:2010  Labelling: Please operate this system only as per the instructions in this Installation Guide and with the components provided by SENSeOR in the system. Do not use with other antennas. Please note that this device may exceed permissible RF power emission levels if used with high gain antennas. This may affect other devices within the transmission range. SENSeOR will not hold any liability for violating country-specific regulations. www.senseor.com 4/16 SENSeOR SAS 2. Safety Instructions Read and understand all safety and operating instructions before installing and operating the device. Handle with care when plugging in the power supply. The instrument is powered with low DC voltage as soon as plugged in. Independently of the temperature indicated by the Graphic User Interface, be careful when working in high-temperature environments not to burn y…

Text truncated - open the document above for the full version.

Users Manual

www.senseor.com SENSeOR SAS capital 44 082,25€ RCS Grasse 488 576 430 – APE 7120B 505, route des Lucioles – Navigator B – 06560 Valbonne Sophia Antipolis – France SIRET: 488 576 430 00042 Tel: +33(0)4 97 23 13 20 – Fax: +33(0)4 93 06 08 58 TVA/VAT: FR35 488 576 430 SYSTEME DE MONITORING DE TEMPERATURE TS6 NOTICE D’INSTALLATION Avril 2015 SENSeOR www.senseor.com 2/16 SENSeOR SAS Sommaire Sommaire ................................................................................................................................................ 2 Informations importantes ....................................................................................................................... 3 1. Réglementations (Radio-Fréquence – Sécurité – CEM) .............................................................. 3 2. Instructions de sécurité ............................................................................................................... 4 3. Instructions d’installation ............................................................................................................ 4 Contenu du système ................................................................................................................................ 5 Installation du système ........................................................................................................................... 6 1. Equipement nécessaire ............................................................................................................... 6 2. Installation des capteurs ............................................................................................................. 6 3. Installation de l’antenne d’émission ........................................................................................... 7 4. Installation de l’interrogateur ..................................................................................................... 8 Installation du système ......................................................................................................................... 10 1. Première installation ................................................................................................................. 10 2. Fonctions et options du système .............................................................................................. 10 a. Alarmes programmables ....................................................................................................... 10 b. Sortie analogique (option) ..................................................................................................... 10 Optimisez vos mesures ! ....................................................................................................................... 11 3. Optimisez l’utilisation du capteur ............................................................................................. 11 4. Minimisez le gradient de température (pièce mesurée/capteur) ............................................ 12 Notes ..................................................................................................................................................... 13 www.senseor.com 3/16 SENSeOR SAS Informations importantes Ce système est conçu pour un usage professionnel. Ainsi, SENSeOR n’endossera aucune responsabilité dans d’éventuels dommages résultant directement ou indirectement de son utilisation. Respectez précisément toutes les instructions de sécurité et d’installation décrites ci-après. Installez et utilisez le système uniquement s’il est parfaitement intact et dans les limites décrites dans cette notice. N’utilisez pas ce système s’il est endommagé. SENSeOR n’acceptera aucune responsabilité dans d’éventuels dommages résultant directement ou indirectement de l’utilisation d’un système ayant été modifié sans autorisation ou résultant de la modification de l’un de ses composants. Cette notice ne doit pas être reproduite, entièrement ou partiellement sans l’autorisation écrite de SENSeOR. Cette notice est susceptible d’être modifiée sans information préalable. 1. Réglementations (Radio-Fréquence – Sécurité – CEM) Ce système est certifié/approuvé suivant les normes ci-dessous :  FCC - PART 15.231-C (e) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  IC - RSS‐Gen (4)/RSS‐210 (8) This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.  Sécurité : CEI 61010-1:2010  Marquage : Merci de n’utiliser ce système que suivant les instructions fournies et avec les composants livres par SENSeOR. Ne pas utiliser avec d’autres antennes. Veuillez noter que ce système peut dépasser les niveaux d’émission RF autorisés dans le cas d’une utilisation avec des antennes haute performance. Cela peut impacter d’autres systèmes dans le périmètre d’émission. SENSeOR n’acceptera aucune responsabilité en cas de non-respect des réglementations locales spécifiques. www.senseor.com 4/16 SENSeOR SAS 2. Instructions de sécurité Lisez et comprenez toutes les instructions de sécurité décrites dans cette notice avant d’installer et de mettre en service le système. Manipulez l’interrogateur avec précaution lo…

Text truncated - open the document above for the full version.

Cover Letter(s)

Siège Social : Emitech - 3, rue des Coudriers - Z.A. de l’Observatoire - 78180 MONTIGNY LE BX - France Siret : 344 545 645 00022 - Tél. : 33 (0)1 30 57 55 55 - Fax : 33 (0)1 30 43 74 48 - E-mail : [email protected] - URL : www.emitech.fr SAS au capital de 1 560 000 € - R.C.S. VERSAILLES 344 545 645 - APE 7112B Vendargues August the 16th of 2018 Re: FCC ID: 2AEGUHTR01-2AW Applicant: SENSEOR Correspondence Reference Number: 417122 Form 731 Confirmation Number: TC886807 Date of Original E-mail: 08/03/2018 Dear Dave Galosky Please find below the answers to your questions: Q 1.Please clarify the antenna type used during testing as opposed to what is pictured in the user manual on file. Additionally, please provide the antenna specifications and list/describe any other antennas that may be offered for sale for use with the system. Please also explain operation of the system with respect to considerations described in KDB Publication 662911 D01 Multiple Transmitter Output. If KDB Publication 662911 D01 is not applicable, please describe why. A 1: The antenna currently supplied with the product on the US market is the one used during testing by laboratory (see data sheet attached). No other antenna can be used with this product. A specific connector does not allow the use of any other model. It is true that the antenna visible in the user manual is not exactly the one provided with the product, but this antenna was only a prototype used to make this document. Regarding compliance with KDB Publication 662911 D01, this document does not apply for when tests are made by conduction. However, in our case, all the tests were performed in radiation. Q 2.Please confirm that the output power tests were performed with the device operating in its worst-case configuration. Also, please confirm that there are no end user configuration options that would allow operation at output powers above what has been authorized. A 2 We confirm that the tests were carried out in the worst case, with the highest RF power. This power is fixed in the product firmware and cannot be changed via the user interface. Q 3. Please provided detailed description of operation of the device with multiple sensors simultaneously. Please include a description and verification that when at maximum capacity, the device continues to meet the periodic transmission requirements of rule part 15.231(e). A 3: Please find this information in attached Operation Description with 1, 6 and 12 sensors. You can see that periodic transmission requirements of rule part 15.231(e) are always met whatever the number of number of sensors. If you have any queries, please do not hesitate to contact us. Best Regards, Olivier HEYER EMITECH for SENSEOR

External Photos

Innovative Sensing Systems Wireless Passive SAW Sensors Company Confidential www.senseor.com SENSeOR April 2015 Pictures-external -2 Apr-15 Company Confidential www.senseor.com (Label)

ID Label/Location Info

Wireless Passive SensingSolutions SENSeOR SAS & GmbH –www.senseor.com Apr-15–‹N°› Label HTR01 FCC DateOwnerRevChange Feb01 2015LP1,0Initial Feb18 2015LP1,1Versions : 2AN2AW –6AN –6AW Mar 27 2015LP1,2Updatedbasedon FB fromSecuritycertification Mar 31 2015LP1,3Updatedbasedon FB fromMr Heyer Apr10 2015LP1,4UpdatedwithIC number+ typo correction RSS‐Gen (4). Apr10 2015LP1,5OnlyFCC version kept Apr23 2015LP1,6FCC logo removedper feedback fromMr Heyer SENSeOR SAS & GmbH CompanyConfidential www.senseor.com Apr-15 2 7,5 cm Max 4,3 cm Max Modbus HTR01-2AW –SN# xxxxx DC: 24V / < 200 mA FCC -PART 15.231-C (e) IC -RSS‐Gen (4)/RSS‐210 (8) IEC 61010-1 M/N : HTR01-2AW FCC ID : 2AEGUHTR01-2AW IC : 20049-HTR01-2AW

ID Label/Location Info

Innovative Sensing Systems Wireless Passive SAW Sensors Company Confidential www.senseor.com SENSeOR April 2015 Label_Location -2 Apr-15 Company Confidential www.senseor.com Label –7,5 x 4,3 cm Max

Internal Photos

Innovative Sensing Systems Wireless Passive SAW Sensors Company Confidential www.senseor.com SENSeOR April 2015 Pictures -Internal -2 Apr-15 Company Confidential www.senseor.com WithShielding_ TOP -3 Apr-15 Company Confidential www.senseor.com WithShielding_ BOT -4 Apr-15 Company Confidential www.senseor.com WithoutShielding_ TOP -5 Apr-15 Company Confidential www.senseor.com WithoutShielding_ BOT

Operational Description

Innovative Sensing Systems Wireless Passive SAW Sensors Company Confidential www.senseor.com SENSeOR June 2015 Antenna Connector -2 Jun-15 Company Confidential www.senseor.com In order to comply with 47 CFR Part 15 Subpart C Section 15.203, Senseorworked with a connector supplier in order to develop specific mated connectors to cover this requirement. Using such connectors in the HTR01-2AW, makesimpossible to connectotherantennasthanthe onesprovided. In case of brokenantenna, customercanrequestSenseorfor replacement. Descriptonof specificconnectors: -Outer contact sameas SMB connectors -Center contact exchangedbetweencommun male and femaleSMB connectors. Id est: Common SMB connectorare basedon: SMB Male outercontactmale + center contact male SMB femelle outercontact femelle + center contact femelle SpecificConnectors SpecificMale outercontactmale + center contactfemelle Secificfemelle outercontactfemelle + center contactmale Seebelowfor illustration ElectronicequipmentconAntennaconCablecon Common SMB connectorsSpecificconnectors(usedonHTR01-2AW) ElectronicequipmentconAntennaconCablecon

Test Report

 Siège Social : Emitech - 3, rue des Coudriers - CAP 78 - ZA de l’Observatoire - 78180 MONTIGNY LE BX - France Siret : 344 545 645 00022 - Tél. : 33 (0)1 30 57 55 55 - Fax : 33 (0)1 30 43 74 48 - E-mail : [email protected] - URL : www.emitech.fr S.A. au capital de 1 560 000 € - R.C.S. VERSAILLES 344 545 645 - APE 7112B RD041-14-105723-4A DMO/OHE E.M.C. TEST REPORT According to the standard(s): FCC Part15.207 Equipment under test: Transceiver for SAW sensors HTR01_2AW FCC ID : 2AEGUHTR01-2AW Company: SENSEOR Diffusion: M. TOURETTE (Company: SENSEOR) Number of pages: 11 including 1 annex Ed. Date Modified page(s) Written by Name Visa Technical verification Quality approval Name Visa 0 3-July-2015 Creation David MONTAULON Olivier HEYER Duplication of this test report is only permitted for an integral photographic facsimile. It includes the number of pages referenced here above. This document is the result of testing a specimen or a sample of the product submitted. It does not imply an assessment of the conformity of the whole manufactured products of the tested sample. S10 DT - 000 FOR 00039 (01) R041-14-105723-4A Ed.0 PAGE : 2  NAME OF THE EQUIPMENT UNDER TEST (E.U.T.) : Transceiver for SAW sensors HTR01_2AW FCC ID : 2AEGUHTR01-2AW Serial number : 00100 P/N : None Software version : Not communicated MANUFACTURER’S NAME : SENSEOR APPLICANT’S ADDRESS: Company : SENSEOR Address : LE NAVIGATOR BÂTIMENT B 505 ROUTE DES LUCIOLES 06560 VALBONNE FRANCE Person(s) present during the tests : Nobody Responsible : M. TOURETTE DATE(S) OF TESTS : July 1 st of 2015 TESTS LOCATION(S) : EMITECH MONTPELLIER laboratory in VENDARGUES (34) - FRANCE TESTS SUPERVISOR(S) : NONE TESTS OPERATOR(S) : David MONTAULON R041-14-105723-4A Ed.0 PAGE : 3  CONTENTS 1. INTRODUCTION _____________________________________________________________________ 4 2. REFERENCE DOCUMENT(S) ___________________________________________________________ 4 3. EQUIPMENT UNDER TEST CONFIGURATION SCHEME _____________________________________ 4 4. SUMMARY OF TEST RESULTS _________________________________________________________ 5 5. CONDUCTED EMISSION ______________________________________________________________ 6 ANNEX 1: PHOTOGRAPH(S) _______________________________________________________________ 8 R041-14-105723-4A Ed.0 PAGE : 4  1. INTRODUCTION This document submits the results of Electromagnetic Compatibility tests performed on the equipment Transceiver for SAW sensors HTR01_2AW (denominated hereafter E.U.T.: equipment under test) according to document(s) listed below. 2. REFERENCE DOCUMENT(S) FCC part 15 Subpart C Code of Federal Regulations Title 47 – Telecommunications Chapter 1 – Federal Communications Commission Part 15 – Radio frequency devices Subpart C – Intentional Radiators ANSI C 63.4:2003 American National Standard for Methods of measurement of Radio-Noise from low-voltage. Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz 3. EQUIPMENT UNDER TEST CONFIGURATION SCHEME Transceiver for SAW sensors HTR01_2AW FCC ID : 2AEGUHTR01-2AW 24Vdc AC/DC 115Vac/60Hz Power Supply ANT_1 ANT_2 E.U.T. Cycle and operating mode during emission tests: Normal use Equipment modifications applied during tests: No R041-14-105723-4A Ed.0 PAGE : 5  4. SUMMARY OF TEST RESULTS Tests designation Results satisfying? Comments EMISSION Conducted emission YES Class B N.P.: Not Performed. N.A.: Not Applicable.  In emission: Sample subject to the test complies with prescriptions of the standard(s) FCC Part15.207 according to limits, specified in this test report. R041-14-105723-4A Ed.0 PAGE : 6  5. CONDUCTED EMISSION Temperature (°C): 26.1 Humidity (%HR): 57.2 Pressure (hPa): 1013 Standard: FCC part 15.207 Test method: ANSI C63.4 Test configuration: Tested cable(s) Measure with E.U.T. height 115Vac/60Hz Power Supply L.I.S.N. 40cm Frequency band Tested cable(s) Resolution bandwidth Video bandwidth Detection mode 10MHz-30MHz 115Vac/60Hz Power Supply 10kHz 30kHz Peak 150kHz-1MHz 115Vac/60Hz Power Supply 10kHz 30kHz Peak and average 1MHz-10MHz 115Vac/60Hz Power Supply 10kHz 30kHz Peak In order to show compliance with Part 15.207, E.U.T. was powered by a standard AC/DC converter 115Vac/60Hz. Test method deviation: No Test equipment list: CATEGORY BRAND TYPE N° EMITECH DATE CAL. DATE VAL AC power source KIKUSUI PCR2000L 0800 # # Cable Emitech Current absorber sheath 10653 17/10/2013 17/12/2015 Cable Micro-coax N-3m 10537 05/09/2013 05/11/2015 Cable Micro-coax N-5m 10529 05/09/2013 05/11/2015 LISN AFJ LT42C\10 12007 04/05/2015 04/07/2016 Receiver Agilent E4440A 5824 01/05/2014 01/07/2016 Receiver Rohde & Schwarz ESHS10 3371 16/04/2015 16/06/2017 Shielded enclosure RAY PROOF C.V1 1123 # # Software Nexio BAT EMC 0000 # # Thermohygrometer Testo 608-H1 7561 26/09/2014 26/11/2016 #: Permanent validity BAT-EMC software version: V3.6.0.32 Results: See Graph(s) hereafter. Limits on the graphs are average and quasi-peak limits (upper limit). R041-14-105723-4A Ed.0 PAGE : 7  Conducted voltage emission (measurement) EMI1519 115Vac/60Hz Power Supply 150kHz 30MHz Frequency (MHz)Ligne: Neutre 0 80 dBμV 70 60 50 40 30 20 10 Alimentation 115Vac/60Hz - 07/01/2015 10:30 - 1519 C.E.M. (civil)/FCC Part 15 §107 - Class B - Moyenne/ C.E.M. (civil)/FCC Part 15 §107 - Class B - QCrête/ Mes.Peak (Neutre) Mes.Avg (Neutre) 150kHz30MHz Frequency (MHz)Ligne: Phase 1 0 80 dBμV 70 60 50 40 30 20 10 Alimentation 115Vac/60Hz - 07/01/2015 10:30 - 1519 C.E.M. (civil)/FCC Part 15 §107 - Class B - Moyenne/ C.E.M. (civil)/FCC Part 15 §107 - Class B - QCrête/ Mes.Peak (Phase 1) Mes.Avg (Phase 1) Date: 01/07/2015 10:30:16 Technician: DM Class: B of the standard Detection: Peak and average Modification(s) during test: No  End of report – 1 annex to be forwarded  R041-14-105723-4A Ed.0 PAGE : 8  ANNEX 1: PHOTOGRAPH(S) R041-14-105723-4A Ed.0 PAGE : 9  E.U.T. general view E.U.T. marking plate R041-14-105723-4A Ed.0 PAGE : 10  Conducted voltage emission Conducted voltage emission R0…

Text truncated - open the document above for the full version.

Test Report

RR-030-PTC-15-101289-1-A (01) Page 2 out of 34 TEST CERTIFICATION FOR: FCC Certification NAME OF THE EQUIPMENT UNDER TEST: Transceiver for SAW sensors Type: HTR01-2AW Serial number: Prototype Reference / model (P/N): - Software version: - NAME OF THE MANUFACTURER: SENSEOR ADDRESS OF THE APPLICANT: Company: SENSEOR Address: Le Navigator Bâtiment B 505 route des Lucioles 06560 VALBONNE FRANCE Person in charge: Mr. TOURETTE DATE OF TESTS: 09/03/2015 TESTS LOCATION: EMITECH Laboratory at Montigny-le-Bretonneux (78) FRANCE TESTS OPERATORS: B.PELLERIN / A.BERNARD RR-030-PTC-15-101289-1-A (01) Page 3 out of 34 TABLE OF CONTENTS 1. INTRODUCTION ____________________________________________________________________ 4 2. REFERENCE DOCUMENTS __________________________________________________________ 4 3. PRODUCT DESCRIPTION ____________________________________________________________ 5 4. TESTS AND CONCLUSION ___________________________________________________________ 6 5. TRANSMITTER OUTPUT POWER ______________________________________________________ 7 6. PERIODIC RATE ___________________________________________________________________ 9 7. 20 dB BANDWIDTH ________________________________________________________________ 11 8. UNINTENTIONAL RADIATED EMISSIONS AND TRANSMITTER UNWANTED EMISSION IN THE BAND 9 KHz – 5 GHz _______________________________________________________ 13 9. RADIATED EMISSION LIMIT _________________________________________________________ 17 ANNEX 1: ANTENNA FACTORS, INSERTION LOSSES AND AMPLIFIER VALUES ANNEX 2: EXTERNAL PHOTOGRAPHS ANNEX 3: TEST SETUP PHOTOGRAPHS ANNEX 4: CALIBRATION DATES RR-030-PTC-15-101289-1-A (01) Page 4 out of 34 1. INTRODUCTION This document presents the results of Electromagnetic Compatibility tests performed on the equipment «Transceiver for SAW sensors -Type: HTR01-2AW» according to reference documents listed below. 2. REFERENCE DOCUMENTS FCC 47 CFR Part 15: 2015 Code of Federal Regulations Title 47- Telecommunication Chapter 1- Federal Communication Commission Part 15- Radio frequency devices ANSI C63.4: 2003 Methods of Measurement of Radio-Noise Emissions from Low Voltage Electrical and Electronics Equipment in the range of 9 kHz to 40 GHz. RR-030-PTC-15-101289-1-A (01) Page 5 out of 34 3. PRODUCT DESCRIPTION Antenna type and gain: external antenna (x2) Operating frequency range: from 430 MHz to 450 MHz Power source: 24Vdc Software power setting: - Modification of the equipment during the tests: No E.U.T. is made in plastic enclosure. It is powered to 24Vdc. It allows to make a statement of temperature in several point of the cell and to send these information to a gateway. Transceiver for SAW sensors type HTR01-2AW Power supply 24Vdc Shielded cable <3m Antenna (1A) Shielded cable <3m Antenna (2A) E.U.T. RR-030-PTC-15-101289-1-A (01) Page 6 out of 34 4. TESTS AND CONCLUSION The following table summarizes test results of the EUT. Subpart B of the standard FCC part 15 – Unintentional radiators Test procedure Designation of test Test results Comments Pass Fail N.A. N.P. 15.107 Measurement of conducted emission on AC mains ports X 15.109 Radiated emission limits X Subpart C of the standard FCC part 15 – Intentional radiators Test procedure Designation of test Test results Comments Pass Fail N.A. N.P. 15.205 Restricted bands of operation X 15.207 Measurement of conducted emission on AC mains ports X 15.209 Radiated emission limits; general requirements X 15.215 Additional provisions to the general radiated emission limitations (a) Alternative to general radiated emission limits X (b) Unwanted emissions outside of § 15.247 frequency bands X (c) 20 dB bandwidth and band-edge compliance X 15.231 Intentional radiated emissions a) (1) automatically desactivate X a) (2) automatically activate X a) (3) total duration of transmissions X a) (4) alarm condition X a) (5) duration of transmissions for security systems X b) 40.66 – 40.70 MHz and above 70MHz X c) bandwith for devices above 70 MHz X d) bandwidth for devices 40.66–40.70 MHz with a frequency tolerance for temperature variation of – 20°C to + 50°C at normal supply voltage and for a variation in the primary supply voltage from 85% to 115% at a temperature of 20°C X e) device with a periodic rated other a) X N.A.: Not Applicable N.P.: Not Performed RR-030-PTC-15-101289-1-A (01) Page 7 out of 34 5. TRANSMITTER OUTPUT POWER Standard: FCC 47 CFR PART 15 : 2015 Section: 15.231 (e) for FCC Test configuration: The system is tested in normalized test site. The test unit is placed on a rotating table, 0.8 m from a ground plane. Zero degree azimuth corresponds to the front of the equipment under test. The level was maximised in antenna height, azimuth and polarization. The maximum level measured on the spectrum analyser was recorded. Distance of antenna: 3 meters Instrumentation test list: CATEGORY BRAND TYPE N r EMITECH Antenna SCHAFFNER Bilog CBL6143A 5647 Antenna mast Maturo MCU 8410 Antenna mast Maturo AM 4.0-O 8411 Cable - N-2m 2881 Cable Telegartner N-11m 7405 Cable C&C N-10m 11136 Receiver Rohde & Schwarz R&S ESRP7 10517 Shielded enclosure SIDT C.4 0549 Equipment under test operating condition: EUT is in continuous transmission mode. Measure conditions: Ambient temperature (°C): 22 Relative humidity (%): 40 Resolution bandwidth: 100 kHz RR-030-PTC-15-101289-1-A (01) Page 8 out of 34 Results: Power source: 24Vdc Channel frequency (MHz) Measured Frequency (MHz) Electro-magnetic field (dBμV/m) Limit (dBμV/m) 430.000 429.985 69.98 72.7 440.000 439.980 71.96 73.1 450.000 449.980 72.29 73.4 Test conclusion: Complies with the requirements of the standards. RR-030-PTC-15-101289-1-A (01) Page 9 out of 34 6. PERIODIC RATE Standard: FCC 47 CFR PART 15 : 2014 Section: 15.231 (e) for FCC Test configuration: The system is tested in normalized test site. The test unit is placed on a rotating table, 0.8 m from a ground plane. Zero degree azimuth corresponds to the front of the equipment under test. The level was maximised in…

Text truncated - open the document above for the full version.

Test Report

R412-18-105367-1A Ed.0 Duplication of this test report is only permitted for an integral photographic facsimile. It includes the number of pages referenced here above. This document is the result of testing a specimen or a sample of the product submitted. It does not imply an assessment of the conformity of the whole manufactured products of the tested sample. Siège Social : Emitech - 3, rue des Coudriers - CAP 78 - ZA de l’Observatoire - 78180 MONTIGNY LE BX - France Siret : 344 545 645 00022 - Tél. : 33 (0)1 30 57 55 55 - Fax : 33 (0)1 30 43 74 48 - E-mail : [email protected] - URL : www.emitech.fr S.A. au capital de 1 560 000 € - R.C.S. VERSAILLES 344 545 645 - APE 7112…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Gerhard HEIDER(CEO)
[email protected]33497231335Fax: 33493060858

Test Firm

EMITECH MontpellierOlivier HEYER
[email protected]33-4-67-871102Fax: 33-4-67-709455

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231430 MHz - 450 MHz-
Confidentiality
Long Term