FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: FCC RF Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment End users must follow the specific operating instructions for satisfying RF exposure compliance. This transmitter must not be collocated or operating in conjunction with any other antenna or transmitter. The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.
SCS-F18: Project and Product Certification Representative Authorization Letter Page 1 of 2 Rev 5.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Project and Product Certification Representative Authorization Letter Reason for Amendment (current / obsolete) Revision History Approved Date From To Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Revised wording (obsolete) 1.0 2.0 Sept–25-2007 Updated company template (obsolete) 2.0 3.0 Jan-31-2012 Updated letter information (obsolete) 3.0 4.0 May-23-2014 Added FCC ID field (current) 4.0 5.0 Sept 16 2014 SCS-F18: Project and Product Certification Representative Authorization Letter Page 2 of 2 Rev 5.0 Shenzhen Mileseey Technology Co., Ltd 2015/05/04 To: SIEMIC, INC. 775 Montague Expressway, Milpitas, CA 95035 USA Dear Sir/Madam, Re: Product Certification Representative Authorization Letter We, Shenzhen Mileseey Technology Co., Ltd hereby authorize SIEMIC, Inc. to act as a Certification Body for certifying for the following project(s): Product description: Laser Distance Meter model name: Rock K3, Z1, D5, D8. Trademark: MileSeey FCC ID: 2AEOGROCKK3 Sincerely, Client’s signature Client’s name / title : Ben Wu / Manager Contact information / address: F/6, Building 9, Zhongguan Honghualing Industrial South Park II,1213 Liuxian Ave, Taoyuan Street,Nanshan District, Shenzhen, 518055, P.R. China.
SCS-F19: Confidentiality Request Letter Page 1 of 2 Rev 4.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526- 1188 Fax: 408-526-1088 Email: [email protected] Confidentiality Request Letter Reason for Amendment (current / obsolete) Revision History Approved Date From To Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Adding CFR 2.459 (obsolete) 1.0 2.0 August – 11 - 2008 Updated company template & Added text box (obsolete) 2.0 3.0 Jan-31-2012 Added IC confidentiality letter form (current) 3.0 4.0 March-26-2015 SCS-F19: Confidentiality Request Letter Page 2 of 2 Rev 4.0 Shenzhen Mileseey Technology Co., Ltd 2015/05/04 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Subject: Permanent Confidentiality Request for FCC ID: 2AEOGROCKK3 We hereby request confidential treatment of information accompanying this application as outlined below: - e.g. Block Diagram - e.g. Schematics - e.g. Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Client’s signature Client’s name / title : Ben Wu / Manager Contact information / address: F/6, Building 9, Zhongguan Honghualing Industrial South Park II,1213 Liuxian Ave, Taoyuan Street,Nanshan District, Shenzhen, 518055, P.R. China.
Shenzhen Mileseey Technology Co., Ltd Federal Communications Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 Date: 2015.5.4 SUBJECT: FCC Application for (FCC ID: 2AEOGROCKK3) To Whom It May Concern: We, the undersigned, hereby attest to the fact that we will apply the Declaration of Conformity procedure to the class B computer peripheral portion of this composite device. We understand that devices subject to the DoC procedure are required to be tested to show compliance with the FCC technical regulations by a recognized accredited testing laboratory. The testing laboratory must be accredited by a Commission approved accreditation body or designated under the terms of a government-to-government Mutual Recognition Agreement (MRA). A listing of those accredited testing laboratories that have been recognized by the Commission is published on the FCC Webpage: https://apps.fcc.gov/oetcf/eas/reports/TestFirmSearch.cfm Select the "accredited" option to search for FCC recognized accredited test firms. Test facilities located in countries, where the U.S. does not have an operational Telcom MRA are not recognized by the FCC to test for the DoC procedure. Regards, Signatory Signature Client’s name / title : Ben Wu / Manager Contact information / address: F/6, Building 9, Zhongguan Honghualing Industrial South Park II,1213 Liuxian Ave, Taoyuan Street,Nanshan District, Shenzhen, 518055, P.R. China.
Shenzhen Mileseey Technology Co., Ltd Model Difference FCC ID: 2AEOGROCKK3 Model : Rock K3, Z1, D5, D8. All the models are the same circuit and RF module, except the mode names. Regards Sincerely Client’s signature Client’s name / title : Ben Wu / Manager Contact information / address: F/6, Building 9, Zhongguan Honghualing Industrial South Park II,1213 Liuxian Ave, Taoyuan Street,Nanshan District, Shenzhen, 518055, P.R. China.
Shenzhen BCTC Technology Co., Ltd. Report No.: BCTC-150100525 FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page1 of 13 APPENDIX-PHOTOGRAPHS OF EUT CONSTRUCTIONAL DETAILS Photo 1 Photo 2 Shenzhen BCTC Technology Co., Ltd. Report No.: BCTC-150100525 FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page2 of 13 Photo 3 Photo 4 Shenzhen BCTC Technology Co., Ltd. Report No.: BCTC-150100525 FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page3 of 13 Photo 5 Photo 6 Shenzhen BCTC Technology Co., Ltd. Report No.: BCTC-150100525 FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page4 of 13 Photo 7 Photo 8 Shenzhen BCTC Technology Co., Ltd. Report No.: BCTC-150100525 FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page5 of 13 Photo 9
Model: Rock K3 FCC ID: 2AEOGROCKK3 Shenzhen Mileseey Technology Co., Ltd This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1)This device may not cause harmful interference, and (2) this de vice must accept any interference received, including interference that may cause undesired operation.
Shenzhen BCTC Technology Co., Ltd. Report No.: BCTC-150100525 FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page5 of 13 Photo 9 Shenzhen BCTC Technology Co., Ltd. Report No.: BCTC-150100525 FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page6 of 13 Photo 11 Photo 10 Shenzhen BCTC Technology Co., Ltd. Report No.: BCTC-150100525 FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page7 of 13 Photo 12 Photo 13 Shenzhen BCTC Technology Co., Ltd. Report No.: BCTC-150100525 FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page8 of 13 Photo 14 Photo 15 Shenzhen BCTC Technology Co., Ltd. Report No.: BCTC-150100525 FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page9 of 13 Photo 16 Photo 17 Shenzhen BCTC Technology Co., Ltd. Report No.: BCTC-150100525 FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page10 of 13 Photo 18 Photo 19 Shenzhen BCTC Technology Co., Ltd. Report No.: BCTC-150100525 FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page11 of 13 Photo 20 Photo 21 BT ANT Shenzhen BCTC Technology Co., Ltd. Report No.: BCTC-150100525 FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page12 of 13 Photo 22 Photo 23 Shenzhen BCTC Technology Co., Ltd. Report No.: BCTC-150100525 FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page13 of 13 Photo 24 Photo 25
FCC ID: 2AEOGROCKK3 RF EXPOSURE EVALUATION METHOD SAR Test Exclusion Thresholds for 100 MHz – 6 GHz and ≤ 50 mm Approximate SAR Test Exclusion Power Thresholds at Selected Frequencies and Test Separation Distances are illustrated in the following Table. The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. FCC ID: 2AEOGROCKK3 BT/1Mbps: max possible output power (PK,conducted)/2402MHz:-1±1dbm max possible output power (PK,conducted)/2441MHz:-2±1dbm max possible output power (PK,conducted)/2480MHz:-2±1dbm BT/2Mbps: max possible output power (PK,conducted)/2402MHz:-1±1dbm max possible output power (PK,conducted)/2441MHz:-2±1dbm max possible output power (PK,conducted)/2480MHz:-2±1dbm BT/3Mbps: max possible output power (PK,conducted)/2402MHz:-1±1dbm max possible output power (PK,conducted)/2441MHz:-2±1dbm max possible output power (PK,conducted)/2480MHz:-2±1dbm 2402MHz: 0dbm=1mW [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] · [√f(GHz)]= 1/5*√2.402=0.31≤3.0 Threshold at which no SAR required is 10mw and ≤ 3.0 for 1-g SAR, Separation distance is 5mm. 2441MHz: -1dbm=0.794mW [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] · [√f(GHz)]= 0.794/5*√2.441=0.248≤3.0 Threshold at which no SAR required is 10mw and ≤ 3.0 for 1-g SAR, Separation distance is 5mm. FCC ID: 2AEOGROCKK3 2480MHz: -1dbm=0.794mW [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] · [√f(GHz)]= 0.794/5*√2.480=0.248≤3.0 Threshold at which no SAR required is 10mw and ≤ 3.0 for 1-g SAR, Separation distance is 5mm. Conclusion: No SAR is required.
Shenzhen BCTC Technology Co., Ltd. Report No.: BCTC-15020038 FCC Part 15C Test Report FCC ID: 2AEOGROCKK3 Product Name: Laser Distance Meter Trademark: MileSeey Model Name : Rock K3 Z1,D5,D8. Prepared For : Shenzhen Mileseey Technology Co., Ltd Address : F/6, Building 9, Zhongguan Honghualing Industrial South Park II,1213 Liuxian Ave, Taoyuan Street,Nanshan District, Shenzhen, 518055, P.R. China. Prepared By : Shenzhen BCTC Technology Co., Ltd. Address : No.101,Yousong Road,Longhua New District, Shenzhen,China Test Date: May. 04 - May. 10, 2015 Date of Report : May. 10, 2015 Report No.: BCTC-15020038 Shenzhen BCTC Technology Co., Ltd. Report No.: BCTC-15020038 FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page 2 of 68 VERIFICATION OF COMPLIANCE Applicant’s name ................. : Shenzhen Mileseey Technology Co., Ltd Address ................................. : F/6, Building 9, Zhongguan Honghualing Industrial South Park II,1213 Liuxian Ave, Taoyuan Street,Nanshan District, Shenzhen, 518055, P.R. China. Manufacture's Name ............ : Shenzhen Mileseey Technology Co., Ltd Address ................................. : F/6, Building 9, Zhongguan Honghualing Industrial South Park II,1213 Liuxian Ave, Taoyuan Street,Nanshan District, Shenzhen, 518055, P.R. China. Product description Product name ............................ : Laser Distance Meter Trademark: MileSeey Model Name: Rock K3 Test procedure FCC Part15.247 Standards ANSI C63.10-2013 This device described above has been tested by BCTC, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of BCTC, this document may be altered or revised by BCTC, personal only, and shall be noted in the revision of the document. Test Result.............................................. : Pass Testing Engineer : (Eric Yang) Technical Manager : (Sophia Lee) Authorized Signatory : (Carson. Zhang) Shenzhen BCTC Technology Co., Ltd. Report No.: BCTC-15020038 FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page 3 of 68 Table of Contents Page 1 . SUMMARY OF TEST RESULTS 6 1.1 TEST FACILITY 7 1.2 MEASUREMENT UNCERTAINTY 7 2 . GENERAL INFORMATION 8 2.1 GENERAL DESCRIPTION OF EUT 8 2.2 DESCRIPTION OF TEST MODES 10 2.3 TABLE OF PARAMETERS OF TEXT SOFTWARE SETTING 10 2.4 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 11 2.5 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE) 12 2.6 EQUIPMENTS LIST FOR ALL TEST ITEMS 13 3 . EMC EMISSION TEST 14 3.1 CONDUCTED EMISSION MEASUREMENT 14 3.1.1 POWER LINE CONDUCTED EMISSION LIMITS 14 3.1.2 TEST PROCEDURE 15 3.1.3 DEVIATION FROM TEST STANDARD 15 3.1.4 TEST SETUP 15 3.1.5 EUT OPERATING CONDITIONS 15 3.1.6 TEST RESULTS 16 3.2 RADIATED EMISSION MEASUREMENT 18 3.2.1 RADIATED EMISSION LIMITS 18 3.2.2 TEST PROCEDURE 20 3.2.3 DEVIATION FROM TEST STANDARD 20 3.2.4 TEST SETUP 21 3.2.5 EUT OPERATING CONDITIONS 22 3.2.6 TEST RESULTS 23 4 . NUMBER OF HOPPING CHANNEL 28 4.1 APPLIED PROCEDURES / LIMIT 28 4.1.1 TEST PROCEDURE 28 4.1.2 DEVIATION FROM STANDARD 28 4.1.3 TEST SETUP 28 4.1.4 EUT OPERATION CONDITIONS 28 Shenzhen BCTC Technology Co., Ltd. Report No.: BCTC-15020038 FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page 4 of 68 Table of Contents Page 4.1.5 TEST RESULTS 29 5 . AVERAGE TIME OF OCCUPANCY 30 5.1 APPLIED PROCEDURES / LIMIT 30 5.1.1 TEST PROCEDURE 30 5.1.2 DEVIATION FROM STANDARD 30 5.1.3 TEST SETUP 31 5.1.4 EUT OPERATION CONDITIONS 31 5.1.5 TEST RESULTS 32 6 . HOPPING CHANNEL SEPARATION MEASUREMENT 38 6.1 APPLIED PROCEDURES / LIMIT 38 6.1.1 TEST PROCEDURE 38 6.1.2 DEVIATION FROM STANDARD 38 6.1.3 TEST SETUP 38 6.1.4 EUT OPERATION CONDITIONS 38 6.1.5 TEST RESULTS 39 7 . BANDWIDTH TEST 45 7.1 APPLIED PROCEDURES / LIMIT 45 7.1.1 TEST PROCEDURE 45 7.1.2 DEVIATION FROM STANDARD 45 7.1.3 TEST SETUP 45 7.1.4 EUT OPERATION CONDITIONS 45 7.1.5 TEST RESULTS 46 8 . PEAK OUTPUT POWER TEST 52 8.1 APPLIED PROCEDURES / LIMIT 52 8.1.1 TEST PROCEDURE 52 8.1.2 DEVIATION FROM STANDARD 52 8.1.3 TEST SETUP 52 8.1.4 EUT OPERATION CONDITIONS 52 8.1.5 TEST RESULTS 53 9 . 100 KHZ BANDWIDTH OF FREQUENCY BAND EDGE 60 9.1 DEVIATION FROM STANDARD 60 9.2 TEST SETUP 61 Shenzhen BCTC Technology Co., Ltd. Report No.: BCTC-15020038 FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page 5 of 68 Table of Contents Page 9.3 EUT OPERATION CONDITIONS 61 9.4 TEST RESULTS 62 10 . ANTENNA REQUIREMENT 66 10.1 STANDARD REQUIREMENT 66 10.2 EUT ANTENNA 66 11 . EUT TEST PHOTO 67 APPENDIX-PHOTOGRAPHS OF EUT CONSTRUCTIONAL DETAILS Shenzhen BCTC Technology Co., Ltd. Report No.: BCTC-15020038 FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page 6 of 68 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15 (15.247) , Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission PASS 15.247(a)(1) Hopping Channel Separation PASS 15.247(b)(1) Peak Output Power PASS 15.247(c) Radiated Spurious Emission PASS 15.247(a)(iii) Number of Hopping Frequency PASS 15.247(a)(iii) Dwell Time PASS 15.247(a)(1) Bandwidth PASS 15.205 Band Edge Emission PASS 15.203 Antenna Requirement PASS NOTE: (1)” N/A” denotes test is not applicable in this Test Report Shenzhen BCTC Technology Co., Ltd. Report No.: BCTC-15020038 FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page 7 of 68 1.1 TEST FACILITY Shenzhen BCTC Technology Co., Ltd. Add.:No.101,Yousong Road,Longhua New District, Shenzhen,China FCC Registration No.:187086 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %。 No. Item Uncertainty 1 Conducted Emission Test ±1.38dB 2 RF p…
Text truncated - open the document above for the full version.
Shenzhen BCTC Technology Co., Ltd. Report No.: BCTC-15020038 FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page 67 of 68 11. EUT TEST PHOTO Radiated Measurement Photos Shenzhen BCTC Technology Co., Ltd. Report No.: BCTC-15020038 FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page 68 of 68 CONDUCTED EMISSION Photos
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 800.00 µW |
Laser Distance Meter
Equipment Class
DTS - Digital Transmission System
Laser Distance Meter with Bluetooth Low Energy
Equipment Class