Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
L5 L4 R5 R4 PV label 09/10/25 PRINT COLOR: Q716-2-1 2AES4-1011 2AES4-1011
Report No.: MFBEMX-WTW-P24060565 Page No. 1 / 8 Report Format Version: 7.1.0 Reference No.: BEMX-WTW-P24060565 RF EXPOSURE REPORT CERTIFICATE OF CONFORMITY FCC Rule Part: FCC Part 2 (Section 2.1093) Report No.: MFBEMX-WTW-P24060565 FCC ID: 2AES4-1011 Product: Valve 1011 Brand: Valve Model No.: 1011 Received Date: 2024/4/24 Test Date: 2025/4/22 Issued Date: 2025/11/5 Applicant: Valve Corporation Address: 10400 NE 4th St Suite 1400, Bellevue, Washington United States 98004 Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Lin Kou Laboratories Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan Test Location: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan FCC Registration / Designation Number: 198487 / TW2021 Approved by: , Date: 2025/11/5 Jeremy Lin / Project Engineer This test report consists of 8 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The test results in the report only apply to the tested sample. The test results in this report are traceable to the national or international standards. Prepared by : Jessica Cheng / Senior Specialist This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our- business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Report No.: MFBEMX-WTW-P24060565 Page No. 2 / 8 Report Format Version: 7.1.0 Reference No.: BEMX-WTW-P24060565 Table of Contents Release Control Record ....................................................................................................................................................... 3 1 Certificate .................................................................................................................................................................... 4 2 Applicable RF Exposure Limit .................................................................................................................................. 5 3 Test Results ................................................................................................................................................................ 6 4 Conclusion .................................................................................................................................................................. 7 5 Information of the Testing Laboratories .................................................................................................................. 8 Report No.: MFBEMX-WTW-P24060565 Page No. 3 / 8 Report Format Version: 7.1.0 Reference No.: BEMX-WTW-P24060565 Release Control Record Issue No. Description Date Issued MFBEMX-WTW-P24060565 Original release. 2025/11/5 Report No.: MFBEMX-WTW-P24060565 Page No. 4 / 8 Report Format Version: 7.1.0 Reference No.: BEMX-WTW-P24060565 1 Certificate Product: Valve 1011 Brand: Valve Test Model: 1011 Sample Status: Engineering sample Applicant: Valve Corporation Test Date: 2025/4/22 FCC Rule Part: FCC Part 2 (Section 2.1093) Standard: KDB 447498 D04 Interim General RF Exposure Guidance v01 The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s RF characteristics under the conditions specified in this report. Report No.: MFBEMX-WTW-P24060565 Page No. 5 / 8 Report Format Version: 7.1.0 Reference No.: BEMX-WTW-P24060565 2 Applicable RF Exposure Limit § 1.1310 Radiofrequency radiation exposure limits. (a) Specific absorption rate (SAR) shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in § 1.1307(b) of this part within the frequency range of 100 kHz to 6 GHz (inclusive). (b) The SAR limits for occupational/controlled exposure are 0.4 W/kg, as averaged over the whole body, and a peak spatial-average SAR of 8 W/kg, averaged over any 1 gram of tissue (defined as a tissue volume in the shape of a cube). Exceptions are the parts of the human body treated as extremities, such as hands, wrists, feet, ankles, and pinnae, where the peak spatial-average SAR limit for occupational/controlled exposure is 20 W/kg, averaged over any 10 grams of tissue (defined as a tissue volume in the …
Text truncated - open the document above for the full version.
□ Normal □ Internal Use ■ Confidential □ Restricted Confidential Project I Antenna Report WNC SAS Tested By Martin Chen 2025/06/29 2 □ Normal □ Internal Use ■ Confidential □ Restricted Confidential Testing Setup(passive Testing) DUT 2. The SG 24 is ideal for the OTA testing of mobile device conformance, particularly for LTE, 5G (<10 GHz) and WiFi protocols. It offers a measurement speed up to 3 times faster and a considerably higher dynamic range in passive antenna measurement mode than the previous version. Available in 3 sizes, with the standard and large models CTIA certifiable. Measurement capabilities driven by MVG WaveStudio software: - Antenna Measurement: Radiation pattern, gain, efficiency with NF to FF transformation and advanced post-processing - OTA Testing including major and 5G protocols: • LTE TDD, FDD, LTE Carrier Aggregation & user defined band, • WiFi a/b/g/n/ac, • NB-IoT, • LTE Cat M1, • and more. 1. 1.Equipment Setup - S parameter •Test Procedure 1.1 Set start and stop frequency and Calibrate the NA with 50 ohm calibration kit 1.2 Connect the NA cable to DUT antenna via SMA or I-PAX connector. 1.3 Measure the DUT antenna performance in the free space and record the s11. DUT 3 □ Normal □ Internal Use ■ Confidential □ Restricted Confidential Test-instruments Calibrated-UntilCalibrated-DateSerial-NoModel-No Description Manufacturer 2026/9/82025/9/8N/A555-FAC Anechoic Chamber ChamPro 2026/9/32025/9/3N/ASG24-L Antenna Measurement System MVG-SATIMO N/AN/AN/AWaveStudio Control Software MVG-SATIMO N/AN/AN/AFT-130H-U Uninterruptible Power Supply FTUPS 2026/9/32025/9/3N/AWD6000 Wide Band Dipole MVG-SATIMO 2026/9/42025/9/4N/AE5080B Network Analyzer KEYSIGHT N/AN/ACable-RF-01 G06SMC117-G13130C RF-Coaxial Cable GIGALANE N/AN/ACable-RF-02 N/AN/AN/AAEP-24-HPX Absorber From 80 MHz to 50 GHz Note: 1. the test was performed in Satimo chamber 4 □ Normal □ Internal Use ■ Confidential □ Restricted Confidential Return Loss 250024502400Frequency(MHz) -14.30 -18.22 -19.12 Return loss(dB) 1011 1011 5 □ Normal □ Internal Use ■ Confidential □ Restricted Confidential Antennas Performance Table Note: The antenna performance with a φ1.13 cable of 100mm length shows a loss of about 0.25dB. Avg.2500 2484 2480 2470 2460 2450 2441 2430 2420 2410 2402 2400 Frequency(MHz) 50.82% 48.38%50.88%51.20%51.80%52.40%51.58%51.00%50.90%50.87%50.40%50.32%50.15%Eff. 1011 -2.94 -3.15 -2.93 -2.91 -2.86 -2.81 -2.88 -2.92 -2.93 -2.94 -2.98 -2.98 -3.00 Avg.Gain 2.21 2.38 2.38 2.38 2.36 2.19 2.04 2.02 1.93 1.80 1.67 1.65 Peak Gain 6 □ Normal □ Internal Use ■ Confidential □ Restricted Confidential Antenna Performance Table and Radiation Pattern-2.45GHz 1011 Thank You!
Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Web: http://ee.bureauveritas.com.tw Hwa Ya Lab & Head Office No. 19, Hwa Ya 2nd Rd., Wen Hwa Tsuen Kwei Shan Hsiang, Taoyuan Hsien 333, Taiwan Tel.: 886-3-3183232 Fax: 886-3-2115834 Linkou Lab No. 47, 14th Ling, Chia Pau Tsuen Linkou Hsiang, Taipei Hsien 244, Taiwan Tel.: 886-2-2605-2180 Fax: 886-2-2605-2943 Hsinchu Lab E-2, No.1, Li Hsin 1st Road, Hsinchu Science Park, Hsinchu City, Taiwan Tel.: 886-(0)3-666-8565 Fax: 886-(0)3-666-8323 ANSI C63.10 Standard Deviation American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices ANSI C63.10-2013 ANSI C63.10-2020 Description of Difference (Main changes) ➢ "Frequency hopping spread spectrum procedures were updated to ensure complete on and off times are correctly considered" ➢ DTS and NII procedures were updated to align with the latest FCC KDBs ➢ Millimeter wave measurement procedures were updated ➢ TV White Space test methods were added to the standard ➢ Pulse desensitization considerations for FMCW type signals are now addressed by the standard ➢ Procedures were added for Wireless Power Transfer (WPT) devices that transmit information on the charging frequency ➢ Measurement procedures were generally updated to allow for more accurate analyzer sweep time settings where “auto” was previously required ➢ Editorial corrections/updates were made to the standard ➢ Requirements for including spectral plots were added ➢ An informative annex was included to provide an overview of DFS for NII devices ➢ Procedures for measuring ultra-wideband devices Technical Judgment: Based on engineering judgment, these updates have no impact on the validity of the test results and do not alter the compliance conclusion of the product. If the RF characteristics of a certified device remain unchanged from the initial certificate, and the PCB layout, hardware components, and software are not changed, no further action is deemed necessary. The product remains compliant with all requirements in the new issue and can continue to be manufactured, imported, distributed, leased, offered for sale, or sold in United States. For any changes or uncertainties regarding the device, all supporting RF characteristics must be verified by Bureau Veritas. Report No.: RFBEMX-WTW-P24060565 Page No. 1 / 49 Report Format Version: 7.1.0 Reference No.: BEMX-WTW-P24060565 TEST REPORT CERTIFICATE OF CONFORMITY Standard: 47 CFR FCC Part 15, Subpart C (Section 15.247) Report No.: RFBEMX-WTW-P24060565 FCC ID: 2AES4-1011 Product: Valve 1011 Brand: Valve Model No.: 1011 Received Date: 2024/4/24 Test Date: 2025/4/14 ~ 2025/4/22 Issued Date: 2025/11/5 Applicant: Valve Corporation Address: 10400 NE 4th St Suite 1400, Bellevue, Washington United States 98004 Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Lin Kou Laboratories Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan Test Location: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan FCC Registration / Designation Number: 198487 / TW2021 Approved by: , Date: 2025/11/5 Jeremy Lin / Project Engineer This test report consists of 49 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The test results in the report only apply to the tested sample. The test results in this report are traceable to the national or international standards. Prepared by : Jessica Cheng / Senior Specialist This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our- business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Report No.: RFBEMX-WTW-P24060565 Page No. 2 / 49 Report Format Version: 7.1.0 Reference No.: BEMX-WTW-P24060565 Table of Contents Release Control Record ....................................................................................................................................................... 4 1 Certificate .................................................................................................................................................................... 5 2 Summary of Test Results .......................................................................................................................................... 6 2.1 Measurement Uncertainty ...........................................................................................…
Text truncated - open the document above for the full version.
No.19, Hwa Ya 2nd Rd., Wen Hwa Vil., · Taiwan
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 799.80 µW |
Video Game Machine
Equipment Class
DTS - Digital Transmission SystemValve 1013
Equipment Class
DTS - Digital Transmission SystemValve 1014
Equipment Class
DTS - Digital Transmission SystemValve 1012
Equipment Class
DTS - Digital Transmission System
BT + BLE + NORDIC and WLAN DTS/UNII a/b/g/n/ac
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter