Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FCC WARNING This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE 1: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE 2: This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or communication equipment operating between 0.45β30 MHz. Variations of this language are permitted provided all the points of the statement are addressed and may be presented in any legible font or text style. Safety Information for RF Exposure The device should not be used next to the body. This device is designed for desktop usage. This device has been tested for compliance with RF exposure limits at 10 cm from user.
MobilePal LLC Model: QIWI-G2 REPORT NO.: STR15058110I-1 FCC PART 15 EXHIBIT 2 - EUT EXTERNAL PHOTOGRAPHS EUT View 1 EUT View 2 MobilePal LLC Model: QIWI-G2 REPORT NO.: STR15058110I-1 FCC PART 15 EUT View 3 EUT View 4 MobilePal LLC Model: QIWI-G2 REPORT NO.: STR15058110I-1 FCC PART 15 EUT View 5 EUT View 6 MobilePal LLC Model: QIWI-G2 REPORT NO.: STR15058110I-1 FCC PART 15 EUT View 7 (White) EUT View 8 MobilePal LLC Model: QIWI-G2 REPORT NO.: STR15058110I-1 FCC PART 15 EUT View 9
MobilePal LLC Model: QIWI-G2 REPORT NO.: STR15058110I-1 FCC PART 15 EXHIBIT 1 - PRODUCT LABELING Proposed FCC ID Label Format FCC ID: 2AEUJ-QIWI-G2 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Specifications : Text is Black in color and justified. Labels are printed in indelible ink on permanent adhesive silk-screened onto the EUT or shall be affixed at a conspicuous location on the EUT. Proposed Label Location on EUT FCC ID Label Location
MobilePal LLC Model: QIWI-G2 REPORT NO.: STR15058110I-1 FCC PART 15 EXHIBIT 1 - PRODUCT LABELING Proposed FCC ID Label Format FCC ID: 2AEUJ-QIWI-G2 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Specifications : Text is Black in color and justified. Labels are printed in indelible ink on permanent adhesive silk-screened onto the EUT or shall be affixed at a conspicuous location on the EUT. Proposed Label Location on EUT FCC ID Label Location
MobilePal LLC Model: QIWI-G2 REPORT NO.: STR15058110I-1 FCC PART 15 EXHIBIT 3 - EUT INTERNAL PHOTOGRAPHS EUT Housing and Board View 1 EUT Housing and Board View 2 Induction Antenna MobilePal LLC Model: QIWI-G2 REPORT NO.: STR15058110I-1 FCC PART 15 Solder Board-Component View 1 Solder Board-Component View 2 MobilePal LLC Model: QIWI-G2 REPORT NO.: STR15058110I-1 FCC PART 15 Solder Board-Component View 3 Solder Board-Component View 4
1. RF Exposure Test Report 1.1 General Information Client Information Applicant: MobilePal LLC Address of applicant: 248 Route 25A Suite 99, East Setauket, NY 11733, USA Manufacturer: HONGKONG ITUS CO.,LTD Address of manufacturer: C-520,C Bldg Tianhui Building, Donghuan 1st Road, LongHua New District, Shenzhen, Guangdong Description of EUT Product Name: Wireless power bank Trade Name: MobilePal Model No.: QIWI-G2 FCC ID: 2AEUJ-QIWI-G2 Rated Voltage: USB Input: DC 5V 2.0A Frequency Range: 110-205kHz Rated Voltage: DC 5V (Wireless output) Rated Current: 1A (Wireless output) Rated Power: 5W (Wireless output) 1.2 Standard Applicable According to Β§1.1307(b)(1), system operating under the provisions of this section shall be operating in a manner that the public is not exposed to radio frequency energy level in excess limit for maximum permissible exposure. (a) Limits for Occupational / Controlled Exposure Frequency range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm 2 ) Averaging Times | E | 2 , | H | 2 or S (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842/f 4.89/f (900/f)* 6 30-300 61.4 0.163 1.0 6 300-1500 / / F/300 6 1500-100000 / / 5 6 (b) Limits for General Population / Uncontrolled Exposure Frequency range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm 2 ) Averaging Times | E | 2 , | H | 2 or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180/f)* 30 30-300 27.5 0.073 0.2 30 300-1500 / / F/1500 30 1500-100000 / / 1 30 Note: f = frequency in MHz: * = Plane-wave equivalents power density 1.3 Test Conditions Test Mode Description Remark TM1 Full Load With resistor TM2 Zero Charge With mobile phone TM3 Intermediate Charge With mobile phone TM4 Full Charge With mobile phone Measurement Distance: 10 cm Test Standard: KDB 680106 D01 V02 1.4 Test Result The following test data shall to demonstrate RF exposure compliance. Test Mode: TM1 (with resistor) Electric Field Emissions Test Position Measure Value (V/m) Limit(V/m) 30% Limit (V/m) Top 2.55 614 184.2 Bottom 2.32 614 184.2 Side 1 1.88 614 184.2 Side 2 1.92 614 184.2 Side 3 1.71 614 184.2 Side 4 1.89 614 184.2 Magnetic Field Emissions Test Position Measure Value (A/m) Limit(A/m) 30% Limit (A/m) Top 0.0067 1.63 0.489 Bottom 0.0061 1.63 0.489 Side 1 0.0053 1.63 0.489 Side 2 0.0059 1.63 0.489 Side 3 0.0048 1.63 0.489 Side 4 0.0044 1.63 0.489 Test Mode: TM2/TM3/TM4 (with mobile phone) Electric Field Emissions Test Position Measure Value (V/m) Limit (A/m) 30% Limit (A/m) TM1 TM2 TM3 Top 2.21 3.51 2.91 614 184.2 Bottom 2.33 3.42 2.45 614 184.2 Side 1 2.09 2.12 2.32 614 184.2 Side 2 1.95 2.19 2.15 614 184.2 Side 3 1.53 2.68 1.89 614 184.2 Side 4 2.11 2.07 2.23 614 184.2 Magnetic Field Emissions Test Position Measure Value (V/m) Limit (A/m) 30% Limit (A/m) TM1 TM2 TM3 Top 0.0052 0.0078 0.0069 1.63 0.489 Bottom 0.0063 0.0077 0.0063 1.63 0.489 Side 1 0.0048 0.0067 0.0055 1.63 0.489 Side 2 0.0051 0.0065 0.0046 1.63 0.489 Side 3 0.0053 0.0053 0.0042 1.63 0.489 Side 4 0.0042 0.0069 0.0053 1.63 0.489 1.5 Test Photos
MobilePal LLC Model: QIWI-G2 REPORT NO.: STR15058110I-1 PAGE 1 OF 27 FCC PART 15.209 FCC Part 15C Measurement and Test Report For MobilePal LLC 248 Route 25A Suite 99, East Setauket, NY 11733, USA FCC ID: 2AEUJ-QIWI-G2 Test Rule(s): FCC Part 15C Product Description: Wireless power bank Tested Model: QIWI-G2 Report No.: STR15058110I-1 Tested Date: 2015-05-28 to 2015-06-01 Issued Date: 2015-06-02 Tested By: Jason Su / Engineer Reviewed By: Lahm Peng / EMC Manager Approved & Authorized By: Jandy so / PSQ Manager Prepared By: Shenzhen SEM.Test Technology Co., Ltd. 1/F, Building A, Hongwei Industrial Park, Liuxian 2nd Road, Bao'an District, Shenzhen, P.R.C.οΌ518101οΌ Tel.: +86-755-33663308 Fax.: +86-755-33663309 Website: www.semtest.com.cn Note: This test report is limited to the above client company and the product model only. It may not be duplicated without prior permitted by Shenzhen SEM.Test Technology Co., Ltd. MobilePal LLC Model: QIWI-G2 REPORT NO.: STR15058110I-1 PAGE 2 OF 27 FCC PART 15.209 TABLE OF CONTENTS 1. GENERAL INFORMATION ................................................................................................................................... 3 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ............................................................................... 3 1.2 TEST STANDARDS ................................................................................................................................................... 4 1.3 TEST METHODOLOGY ............................................................................................................................................. 4 1.4 TEST FACILITY ....................................................................................................................................................... 4 1.5 EUT SETUP AND OPERATION MODE ...................................................................................................................... 5 1.6 SET UP DRAWING DIAGRAM ................................................................................................................................... 6 2. SUMMARY OF TEST RESULTS ........................................................................................................................... 8 3. Β§15.203 - ANTENNA REQUIREMENT .................................................................................................................. 9 3.1 STANDARD APPLICABLE ......................................................................................................................................... 9 3.2 TEST RESULT.......................................................................................................................................................... 9 4. RADIATED EMISSIONS ....................................................................................................................................... 10 4.1 MEASUREMENT UNCERTAINTY ............................................................................................................................ 10 4.2 TEST EQUIPMENT LIST AND DETAILS ................................................................................................................... 10 4.3 TEST PROCEDURE ................................................................................................................................................. 10 4.4 TEST RECEIVER SETUP ......................................................................................................................................... 11 4.5 CORRECTED AMPLITUDE & MARGIN CALCULATION ............................................................................................ 11 4.6 ENVIRONMENTAL CONDITIONS ............................................................................................................................ 11 4.7 SUMMARY OF TEST RESULTS/PLOTS .................................................................................................................... 11 5. CONDUCTED EMISSIONS .................................................................................................................................. 22 5.1 MEASUREMENT UNCERTAINTY ............................................................................................................................ 22 5.2 TEST EQUIPMENT LIST AND DETAILS ................................................................................................................... 22 5.3 TEST PROCEDURE ................................................................................................................................................. 22 5.4 BASIC TEST SETUP BLOCK DIAGRAM ................................................................................................................... 22 5.5 ENVIRONMENTAL CONDITIONS ............................................................................................................................ 23 5.6 TEST RECEIVER SETUP ......................................................................................................................................... 23 5.7 SUMMARY OF TEST RESULTS/PLOTS .................................................................................................................... 23 5.8 CONDUCTED EMISSIONS TEST DATA .................................................................................................................... 23 MobilePal LLC Model: QIWI-G2 REPORT NO.: STR15058110I-1 PAGE 3 OF 27 FCC PART 15.209 1. GENERAL INFORMATION 1.1 Product Description for Equipment Under Test (EUT) Client Information Applicant: MobilePal LLC Address of applicant: 248 Route 25A Suite 99, East Setauket, NY 11733, USA Manufacturer: HONGKONG ITUS CO.,LTD Address of manufacturer: C-520,C Bldg Tianhui Building, Donghuan 1st Road, LongHua New District, Shenzhen, Guangdong General Description of EUT Product Name: Wireless power bank Trade Name: MobilePal Model No.: QIWI-G2 Addinβ¦
Text truncated - open the document above for the full version.
MobilePal LLC Model: QIWI-G2 REPORT NO.: STR15058110I-1 FCC PART 15 EXHIBIT 4 - TEST SETUP PHOTOGRAPHS Conducted Emission Test Setup TM1 (Charging Mode) TM4 (Charging, USB Input and Wireless Output Mode) MobilePal LLC Model: QIWI-G2 REPORT NO.: STR15058110I-1 FCC PART 15 Radiation Emission Test Setup (Below 30MHz) TM3 (Wireless Output Mode) TM4 (Charging, USB Input and Wireless Output Mode) MobilePal LLC Model: QIWI-G2 REPORT NO.: STR15058110I-1 FCC PART 15 Radiation Emission Test Setup (30MHz to 1GHz) TM1 (Charging Mode) TM2 (USB Output Mode) MobilePal LLC Model: QIWI-G2 REPORT NO.: STR15058110I-1 FCC PART 15 TM3 (Wireless Output Mode) TM4 (Charging, USB Input and Wireless Output Mode)
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.11 MHz - 0.205 MHz | - |