2 4 3 1 CM00150 CM00149 CM00151 WWW.COLLECTIVEMINDS.CA 1 TABLE OF CONTENTS INTRODUCTION ..........................................................................................................3 KIT INCLUDES .............................................................................................................3 GETTING STARTED ....................................................................................................4 STRIKEPACK HORIZON™ Setup ................................................................................4 THE STRIKEPACK HORIZON™ DEVICE................................................................... 6 Operating the STRIKEPACK HORIZON™ ...............................................................6 MAPPING MODE .........................................................................................................7 UPDATER MODE .........................................................................................................7 HARD FACTORY RESET .............................................................................................7 WWW.COLLECTIVEMINDS.CA 2 INTRODUCTION Thank you for purchasing the STRIKEPACK HORIZON™ for the Xbox Series X|S® and Xbox One® consoles. The STRIKEPACK HORIZON™ is an app-powered wired controller adapter that adds advanced gaming functionality to your existing standard Xbox® controller. The adapter upgrades your controller with 4 Paddles and provides access to M.O.D.s (Macros On Demand) via the STRIKEPACK™ Central smartphone app for iOS 15.0 and Android 9.0, or later, all without any plug in the 10ft cable, and get ready to experience lightning reaction times and unlimited control. Anti-Recoil, Turbo, Button Record & Playback, and much more. The STRIKEPACK HORIZON™ is the future of STRIKEPACK™, and our whole team at Collective Minds is excited to bring that future to you. We have spent countless hours, and sleepless nights, pushing the device through extreme game [email protected] and we will be more than happy to help you out. Also, there are plenty of videos to help you setup and maximize your fun over at www.collectiveminds.ca and our YouTube support channel - feel free to check them out along with our other Collective Minds products! KIT INCLUDES STRIKEPACK HORIZON™ device with 4 Paddles. USB Adapter for Xbox® controller (USB-C) USB Adapter for Xbox One® controller (Micro USB) NOTE: THIS MANUAL HAS BEEN REVISED WITH INSTRUCTIONS THAT ARE VALID ONCE THE XBOX SERIES X|S® STRIKEPACK™ HAS BEEN UPDATED. NOTE: THIS MANUAL HAS BEEN REVISED WITH INSTRUCTIONS THAT ARE VALID ONCE THE STRIKEPACK HORIZON™ HAS BEEN UPDATED. WWW.COLLECTIVEMINDS.CA 3 8. The STRIKEPACK HORIZON™ is an app-powered device, but without the app, you can still use Tournament Mode, map the paddles, and factory reset the device. The STRIKEPACK™ Central smartphone app is required to access GAMEPACK M.O.D.s (Macros On Demand) and advanced stores, and it requires a minimum of at least iOS 15.0 or Android 9.0, or later. 9. STRIKEPACK HORIZON™ device serial and ask to connect. Accept the connection to connect to the app. WWW.COLLECTIVEMINDS.CA 4 MAPPING MODE Paddle Mapping is a very simple process that can be done using the controller. To enter Mapping Mode, HOLD eit her one of the Mapping Mode Buttons until t he Gear Head Eyes and RGB LED indicators turn PURPLE. From here, while HOLDING a controller button, TAP the Paddle that you wish to map the button to. You can HOLD up to 4 controller buttons to be mapped to a single Paddle. If you TAP a Paddle while NO controller buttons are held, it will clear the Paddle of any current mapping. To exit Mapping Mode, TAP eit her one of the Mapping Mode Buttons. the app. UPDATER MODE If you want to be able to update the STRIKEPACK HORIZON™ without having to remove it from your controller each time, use the following method: HOLD Paddles 1 & 3 together while you are connecting the cable of the STRIKEPACK™ to the USB port of your Windows 10 or higher PC. The STRIKEPACK™ should be successfully detected in the Universal Updater Tool. HARD FACTORY RESET If you need to return the STRIKEPACK HORIZON™ to the factory settings for its changes and updates to the device over time. HOLD BOTH Mapping Mode Buttons together while you are connecting the cable of the STRIKEPACK™ to the USB port of your Xbox® console or PC. Keep the Mapping Mode Buttons HELD until you see HOT PINK Gear Head Eyes and RGB LED indicators This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or elevision reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. The device has been evaluated t…
Text truncated - open the document above for the full version.
Collective Minds Gaming Co., Ltd. Section 2.911(d)(5)(i) Certification – Equipment Type Company name: Collective Minds Gaming Co., Ltd. Address: 5000 Jean Talon West, Suite# 250, Montreal, Quebec, Montreal H4P 1W9, Canada Product Name: Xbox Strike Pack Vista – 4 Button FCC ID: 2AEVW-CM00149 Model(s): CM00149 2.911(d)(5)(i) Equipment Type We, [Collective Minds Gaming Co., Ltd.] certify that the equipment for which authorization is sought through certification is not: Prohibited from receiving an equipment authorization pursuant to § 2.903; of the FCC rules. Identified as an equipment type in the “Covered List” NOTE 1 Yours sincerely, Signature: Name: Sanjay Singh Date: 2023-09-12 Title and Company name: Managing Partner and SHENZHEN GIEC DIGITAL CO., LTD NOTE 1 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
Collective Minds Gaming Co., Ltd. Section 2.911(d)(5)(ii) Certification – Applicant (Covered List ) Company name: Collective Minds Gaming Co., Ltd. Address: 5000 Jean Talon West, Suite# 250, Montreal, Quebec, Montreal H4P 1W9, Canada Product Name: Xbox Strike Pack Vista – 4 Button FCC ID: 2AEVW-CM00149 Model(s): CM00149 2.911(d)(5)(ii) Applicant filing We, [Collective Minds Gaming Co., Ltd.] certify that, as of the date of the filing of the application, the applicant is not identified NOTE 1 on the “Covered List” NOTE 2 ,established pursuant to §1.50002 of this chapter, as an entity producing covered communications equipment. Yours sincerely, Signature: Name: Sanjay Singh Date: 2023-09-12 Title and Company name: Managing Partner and SHENZHEN GIEC DIGITAL CO., LTD NOTE 1 Delete option not applicable to this application. NOTE 2 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
Agent Authorization Company: Collective Minds Gaming Co., Ltd. Address: 5000 Jean Talon West, Suite# 250, Montreal, Quebec, Montreal H4P 1W9, Canada Product Name: Xbox Strike Pack Vista – 4 Button Model Number(s): CM00149 We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2023-09-12 Name: Sanjay Singh Title: Managing Partner Company: Collective Minds Gaming Co., Ltd.
Collective Minds Gaming Co., Ltd. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2023-09-12 Subject; Request for Confidentiality FCC ID: 2AEVW-CM00149 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Operational Description In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuantto KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Sanjay Singh Title: Managing Partner
Page 1 of 4 Test Model No.: CM00149 Page 2 of 4 Page 3 of 4 Page 4 of 4
Xbox Strike Pack Vista Model:CM00149 LOT# 23106510 MADE IN CHINA FCC ID :2AEVW-CM00149 Collective Minds
Page 1 of 5 Test Model No.: CM00149 Page 2 of 5 Page 3 of 5 Page 4 of 5 Page 5 of 5
FCC ID: 2AEVW-CM00149 RF Exposure evaluation According to 447498 D04 Interim General RF Exposure Guidance v01 ERP/EIRP = P T +G T −L C ERP/EIRP is the equivalent (or effective) radiated power [in same units as P T , typically dBW, dBm, or power spectral density (psd)], relative to either a dipole antenna (ERP) or an isotropic antenna (EIRP). P T is the transmitter output power, in dBW, dBm, or psd (power over a specified reference bandwidth). G T is the gain of the transmitting antenna, in dBd (ERP) or dBi (EIRP). L C is the signal attenuation in the connecting cable between the transmitter and the antenna, in dB. FCC ID: 2AEVW-CM00149 For BLE mode Frequency (MHz) Output power to antenna (dBm) Ant gain(dBi) EIRP(dBm) ERP(dBm) ERP(mw) Distance (cm) P th (mW) 2480 1.91 -0.147 1.763 -0.387 0.91 0.5 2.7 ERP = EIRP −2.15 dB WORSE CASE 1.50mW<2.7mW For BT EDR mode Frequency (MHz) Output power to antenna (dBm) Ant gain(dBi) EIRP(dBm) ERP(dBm) ERP(mw) Distance (cm) P th (mW) 2480 1.94 -0.147 1.793 -0.357 0.92 0.5 2.7 ERP = EIRP −2.15 dB WORSE CASE 1.51mW<2.7mW Remark: Then SAR evaluation is not required
Report No.: GTS2023080382F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 1 of 17 AppendixA: 20dB Emission Bandwidth Test Result Test Mode Antenna Frequency[MHz] 20db EBW[MHz] FL[MHz] FH[MHz] DH5 Ant1 2402 0.942 2401.502 2402.444 DH5 Ant1 2441 0.951 2440.508 2441.459 DH5 Ant1 2480 0.954 2479.508 2480.462 2DH5 Ant1 2402 1.263 2401.340 2402.603 2DH5 Ant1 2441 1.350 2440.292 2441.642 2DH5 Ant1 2480 1.323 2479.307 2480.630 3DH5 Ant1 2402 1.341 2401.298 2402.639 3DH5 Ant1 2441 1.350 2440.292 2441.642 3DH5 Ant1 2480 1.281 2479.319 2480.600 Test Graphs DH5-Ant1-2402 DH5-Ant1-2441 DH5-Ant1-2480 2DH5-Ant1-2402 Report No.: GTS2023080382F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 17 2DH5-Ant1-2441 2DH5-Ant1-2480 3DH5-Ant1-2402 3DH5-Ant1-2441 / 3DH5-Ant1-2480 / Report No.: GTS2023080382F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 17 AppendixB: Occupied Channel Bandwidth Test Result Test Mode Antenna Frequency[MHz] OCB [MHz] FL[MHz] FH[MHz] DH5 Ant1 2402 0.88215 2401.5416 2402.4238 DH5 Ant1 2441 0.88586 2440.5263 2441.4122 DH5 Ant1 2480 0.90533 2479.5244 2480.4298 2DH5 Ant1 2402 1.1903 2401.3720 2402.5623 2DH5 Ant1 2441 1.2042 2440.3668 2441.5710 2DH5 Ant1 2480 1.2333 2479.3585 2480.5918 3DH5 Ant1 2402 1.1933 2401.3675 2402.5608 3DH5 Ant1 2441 1.2071 2440.3593 2441.5664 3DH5 Ant1 2480 1.2095 2479.3632 2480.5727 Test Graphs DH5-Ant1-2402 DH5-Ant1-2441 DH5-Ant1-2480 2DH5-Ant1-2402 Report No.: GTS2023080382F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 17 2DH5-Ant1-2441 2DH5-Ant1-2480 3DH5-Ant1-2402 3DH5-Ant1-2441 / 3DH5-Ant1-2480 / Report No.: GTS2023080382F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 5 of 17 AppendixC: Maximum conducted output power Test Result Peak Test Mode Antenna Frequency[MHz] Conducted Peak Powert[dBm] Conducted Limit[dBm] Verdict DH5 Ant1 2402 -1.58 ≤30 PASS DH5 Ant1 2441 1.09 ≤30 PASS DH5 Ant1 2480 1.94 ≤30 PASS 2DH5 Ant1 2402 -3.8 ≤20.97 PASS 2DH5 Ant1 2441 -0.35 ≤20.97 PASS 2DH5 Ant1 2480 1.05 ≤20.97 PASS 3DH5 Ant1 2402 -3.34 ≤20.97 PASS 3DH5 Ant1 2441 -0.06 ≤20.97 PASS 3DH5 Ant1 2480 1.27 ≤20.97 PASS Test Graphs DH5-Ant1-2402 DH5-Ant1-2441 DH5-Ant1-2480 2DH5-Ant1-2402 Report No.: GTS2023080382F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 6 of 17 2DH5-Ant1-2441 2DH5-Ant1-2480 3DH5-Ant1-2402 3DH5-Ant1-2441 / 3DH5-Ant1-2480 / Report No.: GTS2023080382F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 7 of 17 AppendixD: Carrier frequency separation Test Result Test Mode Antenna Frequency[MHz] Result[MHz] Limit[MHz] Verdict DH5 Ant1 Hop 1.168 ≥0.954 PASS 2DH5 Ant1 Hop 1.172 ≥0.900 PASS 3DH5 Ant1 Hop 1 ≥0.900 PASS Test Graphs DH5-Ant1-Hop 2DH5-Ant1-Hop / 3DH5-Ant1-Hop / Report No.: GTS2023080382F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 8 of 17 AppendixE: Time of occupancy Test Result Test Mode Antenna Frequency[MHz] BurstWidth [ms] TotalHops [Num] Result[s] Limit[s] Verdict DH5 Ant1 Hop 2.897 106.67 0.309 ≤0.4 PASS DH1 Ant1 Hop 0.400 320 0.128 ≤0.4 PASS DH3 Ant1 Hop 1.649 160 0.264 ≤0.4 PASS 2DH5 Ant1 Hop 2.903 106.67 0.31 ≤0.4 PASS 2DH1 Ant1 Hop 0.404 320 0.129 ≤0.4 PASS 2DH3 Ant1 Hop 1.656 160 0.265 ≤0.4 PASS 3DH5 Ant1 Hop 2.906 106.67 0.31 ≤0.4 PASS 3DH1 Ant1 Hop 0.404 320 0.129 ≤0.4 PASS 3DH3 Ant1 Hop 1.654 160 0.265 ≤0.4 PASS Note: DH5/2DH5/3DH5:TotalHops=1600/79/6*0.4*79 DH5/2DH5/3DH5: Time of occupancy= TotalHops * ( BurstWidth) /1000 DH3/2DH3/3DH3:TotalHops=1600/79/4*0.4*79 DH3/2DH3/3DH3: Time of occupancy= TotalHops * ( BurstWidth) /1000 DH1/2DH1/3DH1:TotalHops=1600/79/2*0.4*79 DH1/2DH1/3DH1: Time of occupancy= TotalHops * ( BurstWidth) /1000 Report No.: GTS2023080382F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 9 of 17 Test Graphs DH5-Ant1-Hop DH1-Ant1-Hop DH3-Ant1-Hop 2DH5-Ant1-Hop 2DH1-Ant1-Hop 2DH3-Ant1-Hop Report No.: GTS2023080382F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 10 of 17 3DH5-Ant1-Hop 3DH1-Ant1-Hop / 3DH3-Ant1-Hop /
Report No.: GTS2023080382F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 11 of 17 AppendixF: Number of hopping channels Test Result Test Mode Antenna Frequency[MHz] Result[Num] Limit[Num] Verdict DH5 Ant1 Hop 79 ≥15 PASS 2DH5 Ant1 Hop 79 ≥15 PASS 3DH5 Ant1 Hop 79 ≥15 PASS Test Graphs DH5-Ant1-Hop 2DH5-Ant1-Hop / 3DH5-Ant1-Hop / Report No.: GTS2023080382F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 12 of 17 AppendixG:Band edge measurements Test Result Test Mode Antenna ChName Frequency[MHz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict DH5 Ant1 Low 2402 -2.35 -49.58 ≤-22.35 PASS DH5 Ant1 High 2480 1.32 -49.63 ≤-18.68 PASS 2DH5 Ant1 Low 2402 -6.07 -49.39 ≤-26.07 PASS 2DH5 Ant1 High 2480 -1.77 -49.31 ≤-21.77 PASS 3DH5 Ant1 Low 2402 -5.57 -49.65 ≤-25.57 PASS 3DH5 Ant1 High 2480 0.10 -48.25 ≤-19.9 PASS DH5 Ant1 Low Hop_2402 -2.44 -49.52 ≤-22.44 PASS DH5 Ant1 High Hop_2480 0.02 -40.8 ≤-19.98 PASS 2DH5 Ant1 Low Hop_2402 -8.51 -49.94 ≤-28.51 PASS 2DH5 Ant1 High Hop_2480 -4.70 -49.75 ≤-24.7 PASS 3DH5 Ant1 Low Hop_2402 -12.62 -50.24 ≤-32.62 PASS 3DH5 Ant1 High Hop_2480 -4.67 -49.46 ≤-24.67 PASS Report No.: GTS2023080382F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 13 of 17 Test Graphs DH5-Ant1-2402 DH5-Ant1-2480 2DH5-Ant1-2402 2DH5-Ant1-2480 3DH5-Ant1-2402 3DH5-Ant1-2480 Report No.: GTS2023080382F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 14 of 17 DH5-Ant1-Hop_2402 DH5-Ant1-Hop_2480 2DH5-Ant1-Hop_2402 2DH5-Ant1-Hop_2480 3DH5-Ant1-Hop_2402 3DH5-Ant1-Hop_2480 Report No.: GTS2023080382F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 15 of 17 AppendixH: Duty Cycle Test Result Test Mode Antenna Frequency[MHz] ON Time [ms] Period [ms] Duty Cycle [%] Duty Cycle Factor[dB] DH5 Ant1 2402 2.89 3.75 77.07 1.13 DH5 Ant1 2441 2.90 3.75 77.33 1.12 DH5 Ant1 2480 2.89 3.75 77.07 1.13 2DH5 Ant1 2402 2.89 3.75 77.07 1.13 2DH5 Ant1 2441 2.91 3.75 77.60 1.10 2DH5 Ant1 2480 2.89 3.75 77.07 1.13 3DH5 Ant1 2402 2.91 3.75 77.60 1.10 3DH5 Ant1 2441 2.89 3.75 77.07 1.13 3DH5 Ant1 2480 2.91 3.75 77.60 1.10 Report No.: GTS2023080382F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 16 of 17 Test Graphs NTNV-DH5-Ant1-2402 NTNV-DH5-Ant1-2441 NTNV-DH5-Ant1-2480 NTNV-2DH5-Ant1-2402 NTNV-2DH5-Ant1-2441 NTNV-2DH5-Ant1-2480 Report No.: GTS2023080382F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 17 of 17 NTNV-3DH5-Ant1-2402 NTNV-3DH5-Ant1-2441 / NTNV-3DH5-Ant1-2480 / ------End------
Global United Technology Services Co., Ltd. Report No.: GTS2023080382F01 Authorized Signature: Robinson Luo Laboratory Manager This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Page 1 of 29 TEST REPORT Applicant: Collective Minds Gaming Co., Ltd. Address of Applicant: 5000 Jean Talon West, Suite# 250, Montreal, Quebec, Montreal H4P 1W9, Canada Manufacturer/Factory: DongGuan KingSheng Electronics&Technology Co., Ltd Address of Manufacturer/Factory: Building 39, Arising Sun Industrial City,LinCun Village, TangXia Town,DongGuan City, China Equipment Under Test (EUT) Product Name: Xbox Strike Pack Vista – 4 Button Model No.: CM00149 FCC ID: 2AEVW-CM00149 Applicable standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247 Date of sample receipt: September 01, 2023 Date of Test: September 01-20, 2023 Date of report issued: September 20, 2023 Test Result : PASS * * In the configuration tested, the EUT complied with the standards specified above. Report No.: GTS2023080382F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 29 2 Version Version No. Date Description 00 September 20, 2023 Original Prepared By: Date: September 20, 2023 Project Engineer Check By: Date: September 20, 2023 Reviewer Report No.: GTS2023080382F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 29 3 Contents Page 1 COVER PAGE ........................................................................................................................................... 1 2 VERSION .................................................................................................................................................. 2 3 CONTENTS .............................................................................................................................................. 3 4 TEST SUMMARY ..................................................................................................................................... 4 5 GENERAL INFORMATION ...................................................................................................................... 5 5.1 GENERAL DESCRIPTION OF EUT ......................................................................................................... 5 5.2 TEST MODE ........................................................................................................................................ 7 5.3 DESCRIPTION OF SUPPORT UNITS ....................................................................................................... 7 5.4 DEVIATION FROM STANDARDS ............................................................................................................. 7 5.5 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................... 7 5.6 TEST FACILITY .................................................................................................................................... 7 5.7 TEST LOCATION ................................................................................................................................. 7 5.8 ADDITIONAL INSTRUCTIONS ................................................................................................................. 7 6 TEST INSTRUMENTS LIST ..................................................................................................................... 8 7 TEST RESULTS AND MEASUREMENT DATA .................................................................................... 10 7.1 ANTENNA REQUIREMENT ................................................................................................................... 10 7.2 CONDUCTED EMISSIONS ................................................................................................................... 11 7.3 CONDUCTED PEAK OUTPUT POWER .................................................................................................. 14 7.4 20DB EMISSION BANDWIDTH ............................................................................................................ 15 7.5 CARRIER FREQUENCIES SEPARATION ................................................................................................ 16 7.6 HOPPING CHANNEL NUMBER ............................................................................................................ 17 7.7 DWELL TIME ..................................................................................................................................... 18 7.8 SPURIOUS EMISSION IN NON-RESTRICTED & RESTRICTED BANDS ....................................................... 19 7.8.1 Conducted Emission Method ..................................................................................................... 19 7.8.2 Radiated Emission Method ........................................................................................................ 20 8 TEST SETUP PHOTO ............................................................................................................................ 29 9 EUT CONSTRUCTIONAL DETAILS ..................................................................................................... 29 Report No.: GTS2023080382F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen…
Text truncated - open the document above for the full version.
Page 1 of 14 Antenna Test Report Report No.: AGC08892200501PA01 PRODUCT DESIGNATION : Cronus Zen BRAND NAME : CollectiveMinds MODEL NAME : CM00053 APPLICANT : Collective Minds Gaming Co., Ltd DATE OF ISSUE : May 29, 2020 REPORT VERSION : V1.0 Attestation of Global Compliance (Shenzhen) Co., Ltd CAUTION: This report shall not be reproduced except in full without the written permission of the test laboratory and shall not be quoted out of context. Report No.: AGC08892200501PA01 Page 2 of 14 REPORT REVISE RECORD Report Version Revise Time Issued Date Valid Version Notes V1.0 / May 29, 2020 Valid Initial release Report No.: AGC08892200501PA01 Page 3 of 14 TABLE OF CONTENTS 1. PRODUCT INFORMATON ...................................................................................................................... 4 2. TEST FACILITY ....................................................................................................................................... 5 3. TEST EQUIPMENT LIST ......................................................................................................................... 5 4. MEASUREMENT UNCERTAINTY .......................................................................................................... 5 5. TEST SUMMARY LIST ............................................................................................................................ 5 6. TEST SETUP ........................................................................................................................................... 6 7. TEST RESULTS .........................................................................................…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.56 mW |

PS5 Strike Pack Horizon
Equipment Class
DTS - Digital Transmission System
XBX Strike Pack Horizon
Equipment Class
DTS - Digital Transmission System
Cronus Zen
Equipment Class
DTS - Digital Transmission System