Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Safety Information Page 1 / 2 CAUTION This product is restricted for occupational use and is not intended or authorised for use by the general population. It is the responsibility of the person operating the product to ensure that it is operated safely at all times, and that local laws and regulations governing the usage of Radio Frequency (RF) products are observed. Users must be trained to operate this product safely. Their personal safety could be affected if they do not understand how to operate this product correctly. Radio Frequency informations This product must be restricted to operations in an Occupational/Controlled RF exposure Environments. Users should be informed of the potential health risks associated with long term exposure to RF energy by their employer. Radio Frequency (RF) is a frequency of electromagnetic radiation in the range at which radio signals are transmitted. RF technology is widely used in communication, medicine, food processing and other fields. It may generate radiation during use. In order to ensure user health, experts from relevant industries including science, engineering, medicine and health work with international organizations to develop standards for safe exposure to RF radiation. Any transmission from this unit must be with a frequency allocated by local regulator. A carefull check must be provided before connecting an antenna to the unit. Servicing and accessories Only accessories approved by Etelm are recommended for use with this product. Always read the instructions supplied with the accessory for additional safety instructions. Unauthorised modifications to the product could cause the product to become non-operational and void any product warranty. The use of non-approved accessories may invalidate any product warranty and may compromise the product safety ratings Do not attempt to dismantle this product. Servicing and repairs of the product must be done by trained service technicians at Etelm. FCC Regulations Federal Communication Commission (FCC) requires that all radio communication products should meet the requirements set forth in the above standards before they can be marketed in the U.S, and the manufacturer shall post a RF label on the product to inform users of operational instructions, so as to enhance their occupational health against exposure to RF energy This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for a controlled environment. The antenna should be installed and operated with minimum distance 1.0m from human body. This transmitter must not be colocated or operating in conjunction with any other antenna or transmitter. Safety Information Page 2 / 2 CAUTION IC Warning This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Installation and Operation Guide Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. The term « IC: » before the certification/registration numbers only signifies that the Industry Canada technical specifications were met. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Le terme « IC: » placé avant les numéros de certificat/enregistrement signifient que conformément à la réglementation d'Industrie Canada. Le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante. This equipment complies with IC RF radiation exposure limits set forth for an controlled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. The antenna should be installed and operated with minimum distance 1.0m from human body. Le présent appareil est conforme aux normes d’IC concernant les limites d’exposition aux rayonnements RF établies pour un environnement contrôlé. Cet émetteur ne doit pas être co-localisé ou opérant en conjonction avec toutes autres antennes ou émetteurs. L'antenne doit être installée et utilisée avec un minimum de 1,0 m de distance d’un corps humain. Environmental Protection Electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or retailer for recycling advice. By ensuring that this product and its packaging is disposed of correctly, you will help prevent potentially negative consequences for the environment and human health, and help conserve natural resources. EU Regulatory Conformance Etelm declares that the product is in compliance with t…
Text truncated - open the document above for the full version.
Safety Information Page 1 / 2 CAUTION This product is restricted for occupational use and is not intended or authorised for use by the general population. It is the responsibility of the person operating the product to ensure that it is operated safely at all times, and that local laws and regulations governing the usage of Radio Frequency (RF) products are observed. Users must be trained to operate this product safely. Their personal safety could be affected if they do not understand how to operate this product correctly. Radio Frequency informations This product must be restricted to operations in an Occupational/Controlled RF exposure Environments. Users should be informed of the potential health risks associated with long term exposure to RF energy by their employer. Radio Frequency (RF) is a frequency of electromagnetic radiation in the range at which radio signals are transmitted. RF technology is widely used in communication, medicine, food processing and other fields. It may generate radiation during use. In order to ensure user health, experts from relevant industries including science, engineering, medicine and health work with international organizations to develop standards for safe exposure to RF radiation. Any transmission from this unit must be with a frequency allocated by local regulator. A carefull check must be provided before connecting an antenna to the unit. Servicing and accessories Only accessories approved by Etelm are recommended for use with this product. Always read the instructions supplied with the accessory for additional safety instructions. Unauthorised modifications to the product could cause the product to become non-operational and void any product warranty. The use of non-approved accessories may invalidate any product warranty and may compromise the product safety ratings Do not attempt to dismantle this product. Servicing and repairs of the product must be done by trained service technicians at Etelm. FCC Regulations Federal Communication Commission (FCC) requires that all radio communication products should meet the requirements set forth in the above standards before they can be marketed in the U.S, and the manufacturer shall post a RF label on the product to inform users of operational instructions, so as to enhance their occupational health against exposure to RF energy This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for a controlled environment. The antenna should be installed and operated with minimum distance 1.0m from human body. This transmitter must not be colocated or operating in conjunction with any other antenna or transmitter. Safety Information Page 2 / 2 CAUTION IC Warning This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Installation and Operation Guide Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. The term « IC: » before the certification/registration numbers only signifies that the Industry Canada technical specifications were met. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Le terme « IC: » placé avant les numéros de certificat/enregistrement signifient que conformément à la réglementation d'Industrie Canada. Le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante. This equipment complies with IC RF radiation exposure limits set forth for an controlled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. The antenna should be installed and operated with minimum distance 1.0m from human body. Le présent appareil est conforme aux normes d’IC concernant les limites d’exposition aux rayonnements RF établies pour un environnement contrôlé. Cet émetteur ne doit pas être co-localisé ou opérant en conjonction avec toutes autres antennes ou émetteurs. L'antenne doit être installée et utilisée avec un minimum de 1,0 m de distance d’un corps humain. Environmental Protection Electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or retailer for recycling advice. By ensuring that this product and its packaging is disposed of correctly, you will help prevent potentially negative consequences for the environment and human health, and help conserve natural resources. EU Regulatory Conformance Etelm declares that the product is in compliance with t…
Text truncated - open the document above for the full version.
RSS-119 issue 11 --- Test Report Revision 1 Test Report Revision 1 II) Photos Front view ETELM 9 Avenue des 2 Lacs P.A. de Villejust 91971 Courtaboeuf Cedex 4 RSS-119 issue 11 --- Test Report Revision 1 Test Report Revision 1 Back view ETELM 9 Avenue des 2 Lacs P.A. de Villejust 91971 Courtaboeuf Cedex 5 RSS-119 issue 11 --- Test Report Revision 1Test Report Revision 1 Side 1 view ETELM 9 Avenue des 2 Lacs P.A. de Villejust 91971 Courtaboeuf Cedex 6 RSS-119 issue 11 --- Test Report Revision 1Test Report Revision 1 Side 2 view ETELM 9 Avenue des 2 Lacs P.A. de Villejust 91971 Courtaboeuf Cedex 7 RSS-119 issue 11 --- Test Report Revision 1 Test Report Revision 1 Top view ETELM 9 Avenue des 2 Lacs P.A. de Villejust 91971 Courtaboeuf Cedex 8 RSS-119 issue 11 --- Test Report Revision 1 Test Report Revision 1 Front perspective view ETELM 9 Avenue des 2 Lacs P.A. de Villejust 91971 Courtaboeuf Cedex 9 RSS-119 issue 11 --- Test Report Revision 1Test Report Revision 1 Back perspective view ETELM 9 Avenue des 2 Lacs P.A. de Villejust 91971 Courtaboeuf Cedex 10
ETELM 9 Avenue des 2 Lacs P.A. de Villejust 91971 Courtaboeuf Cedex FRANCE Internal Photographs Page 1 / 14 Model : NeTISB25 FCC ID : 2AF3I-BSTETRA800 IC ID : 20543-BSTETRA800 Date : 10/11/2015 INTERNAL PHOTOGRAPHS - Alim 48v-800 View 1 ETELM 9 Avenue des 2 Lacs P.A. de Villejust 91971 Courtaboeuf Cedex FRANCE Internal Photographs Page 2 / 14 View 2 ETELM 9 Avenue des 2 Lacs P.A. de Villejust 91971 Courtaboeuf Cedex FRANCE Internal Photographs Page 3 / 14 View 3 ETELM 9 Avenue des 2 Lacs P.A. de Villejust 91971 Courtaboeuf Cedex FRANCE Internal Photographs Page 4 / 14 INTERNAL PHOTOGRAPHS – CPUBDT2 View 1 ETELM 9 Avenue des 2 Lacs P.A. de Villejust 91971 Courtaboeuf Cedex FRANCE Internal Photographs Page 5 / 14 View 2 ETELM 9 Avenue des 2 Lacs P.A. de Villejust 91971 Courtaboeuf Cedex FRANCE Internal Photographs Page 6 / 14 View 3 ETELM 9 Avenue des 2 Lacs P.A. de Villejust 91971 Courtaboeuf Cedex FRANCE Internal Photographs Page 7 / 14 INTERNAL PHOTOGRAPHS – UCM3_800 View 1 ETELM 9 Avenue des 2 Lacs P.A. de Villejust 91971 Courtaboeuf Cedex FRANCE Internal Photographs Page 8 / 14 View 2 ETELM 9 Avenue des 2 Lacs P.A. de Villejust 91971 Courtaboeuf Cedex FRANCE Internal Photographs Page 9 / 14 View 3 ETELM 9 Avenue des 2 Lacs P.A. de Villejust 91971 Courtaboeuf Cedex FRANCE Internal Photographs Page 10 / 14 INTERNAL PHOTOGRAPHS – DCTR View 1 ETELM 9 Avenue des 2 Lacs P.A. de Villejust 91971 Courtaboeuf Cedex FRANCE Internal Photographs Page 11 / 14 View 2 ETELM 9 Avenue des 2 Lacs P.A. de Villejust 91971 Courtaboeuf Cedex FRANCE Internal Photographs Page 12 / 14 View 3 ETELM 9 Avenue des 2 Lacs P.A. de Villejust 91971 Courtaboeuf Cedex FRANCE Internal Photographs Page 13 / 14 INTERNAL PHOTOGRAPHS – PA_800 View 1 ETELM 9 Avenue des 2 Lacs P.A. de Villejust 91971 Courtaboeuf Cedex FRANCE Internal Photographs Page 14 / 14 View 2
Document 75930525 Report 03 Issue 1 September 2015 Report On RF Exposure Assessment of the ETELM SAS NetisB25 Tetra Base Station FCC ID: 0024845661 IC: 20543-BSTETRA800 TÜV SÜD Product Service, Octagon House, Concorde Way, Segensworth North, Fareham, Hampshire, United Kingdom, PO15 5RL Tel: +44 (0) 1489 558100. Website: www.tuv-sud.co.uk Document 75930525 Report 03 Issue 1 Page 1 of 13 REPORT ON RF Exposure Assessment of the ETELM SAS NetisB25 Tetra Base Station Document 75930525 Report 03 Issue 1 September 2015 PREPARED FOR ETELM SAS 9 Avenue des 2 Lacs 91971 Courtaboeuf Cedex France PREPARED BY Ryan Henley Project Manager APPROVED BY Mark Jenkins Authorised Signatory DATED 10 September 2015 Document 75930525 Report 03 Issue 1 Page 2 of 13 CONTENTS Section Page No 1 REPORT SUMMARY ................................................................................................................... 3 1.1 Introduction .................................................................................................................................... 4 1.2 Regional Requirements ................................................................................................................. 5 1.3 Product Information ....................................................................................................................... 6 1.3.1 Technical Description .................................................................................................................... 6 1.3.2 Supported Features ....................................................................................................................... 6 1.3.3 Antennas ........................................................................................................................................ 6 1.4 Brief Summary of Results .............................................................................................................. 7 2 TEST DETAILS ............................................................................................................................ 9 2.1 Rationale for Assessment of the RF Exposure ........................................................................... 10 2.2 Test Result Details ....................................................................................................................... 11 3 DISCLAIMERS AND COPYRIGHT ............................................................................................ 12 3.1 Disclaimers and Copyright ........................................................................................................... 13 Document 75930525 Report 03 Issue 1 Page 3 of 13 SECTION 1 REPORT SUMMARY RF Exposure Assessment of the ETELM SAS NetisB25 Tetra Base Station Document 75930525 Report 03 Issue 1 Page 4 of 13 1.1 INTRODUCTION The information contained in this report is intended to show verification of the RF Exposure Assessment of the ETELM SAS NetisB25 Tetra Base Station to the requirements of the applied test specifications. Objective To perform RF Exposure Assessment to determine the Equipment Under Test's (EUT’s) compliance of the applied rules. Applicant ETELM SAS Manufacturer ETELM SAS Manufacturing Description Tetra Base Station Model Number(s) NetisB25 Test Specification/Issue/Date EN 62311:2008 CFR 47 Pt1.1310 Health Canada Safety Code 6 ARPANSA Radiation Protection Series No.3 Document 75930525 Report 03 Issue 1 Page 5 of 13 1.2 REGIONAL REQUIREMENTS The table below shows the regional requirements that are referenced in this test report. A full list of the requirements is shown in Annex A. Report Reference Regional Requirement EU EN 62311:2008 FCC CFR 47 Pt1.1310 IC Health Canada Safety Code 6 AUS ARPANSA Radiation Protection Series No.3 Document 75930525 Report 03 Issue 1 Page 6 of 13 1.3 PRODUCT INFORMATION 1.3.1 Technical Description The Equipment under test was a ETELM SAS NetisB25 Tetra Base Station. A full technical description can be found in the manufacturer’s documentation. All reported calculations were carried out on the relevant information supplied for the NetisB25 Tetra Base Station to demonstrate compliance with the applied test specification(s) the sample assessed was found to comply with the requirements of the applied rules. 1.3.2 Supported Features The following radio access technologies and frequency bands are supported by the equipment under test. Radio Access Technology Tetra Frequency Band 851.000 to 868.975 1.3.3 Antennas The following antennas are supported by the equipment under test. No. Model Gain (dBi) 1 External 15.83 Document 75930525 Report 03 Issue 1 Page 7 of 13 1.4 BRIEF SUMMARY OF RESULTS The wireless device described within this report has been shown to be capable of compliance with the basic restrictions related to human exposure to electromagnetic fields for both General public and Occupational. The calculations shown in this report were made in accordance the procedures specified in the applied test specification(s). Required Compliance Boundary (m) Occupational General Population 2.06 5.50 Table 1 – Compliance Boundary Results Document 75930525 Report 03 Issue 1 Page 8 of 13 Regional Requirement Calculated RF exposure level at compliance boundary of 2.06 m S Field (W/m 2 ) E Field (V/m) H Field (A/m) Result Limit Result Limit Result Limit ICNIRP 18.7523 21.2750 84.0801 87.5157 0.2230 0.2322 FCC* 1.8752 2.8367 N/A N/A N/A N/A RSS 18.7523 18.8305 84.0801 84.2572 0.2230 0.2235 ARPANSA 18.7523 21.2750 84.0801 89.5577 0.2230 0.2375 * Requirement and Result in mW/cm 2 Table 2 – Occupational Results The calculations show that the EUT complies with the occupational exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310, Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 2.06 m. Regional Requirement Calculated RF exposure level at compliance boundary of 5.50 m S Field (W/m 2 ) E Field (V/m) H Field (A/m) Result Limit Result Limit Re…
Text truncated - open the document above for the full version.
Document 75930525 Report 01 Issue 1 September 2015 Report On FCC and Industry Canada Testing of the ETELM SAS NetisB25 In accordance with FCC 47 CFR Part 90, FCC 47 CFR Part 2 and Industry Canada RSS-119 COMMERCIAL-IN-CONFIDENCE FCC ID: 0024845661 IC: 20543-BSTETRA800 TÜV SÜD Product Service, Octagon House, Concorde Way, Segensworth North, Fareham, Hampshire, United Kingdom, PO15 5RL Tel: +44 (0) 1489 558100. Website: www.tuv-sud.co.uk COMMERCIAL-IN-CONFIDENCE Document 75930525 Report 01 Issue 1 Page 1 of 50 COMMERCIAL-IN-CONFIDENCE REPORT ON FCC and Industry Canada Testing of the ETELM SAS NetisB25 In accordance with FCC 47 CFR Part 90, FCC 47 CFR Part 2 and Industry Canada RSS-119 Document 75930525 Report 01 Issue 1 September 2015 PREPARED FOR ETELM SAS Avenuue des deux lacs PA Villejust Courtaboeuf Cedex 91971 France PREPARED BY Natalie Bennett Senior Administrator, Project Support APPROVED BY Mark Jenkins Authorised Signatory DATED 09 September 2015 ENGINEERING STATEMENT The measurements shown in this report were made in accordance with the procedures described on test pages. All reported testing was carried out on a sample equipment to demonstrate limited compliance with FCC 47 CFR Part 90, FCC 47 CFR Part 2 and Industry Canada RSS-119. The sample tested was found to comply with the requirements defined in the applied rules. Test Engineer(s); M Russell T Guy Document 75930525 Report 01 Issue 1 Page 2 of 50 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE CONTENTS Section Page No 1 REPORT SUMMARY ................................................................................................................... 3 1.1 Introduction ................................................................................................................................... 4 1.2 Brief Summary of Results ............................................................................................................. 5 1.3 Application Form ........................................................................................................................... 6 1.4 Product Information ...................................................................................................................... 8 1.5 Test Conditions ............................................................................................................................. 8 1.6 Deviations from the Standard ....................................................................................................... 8 1.7 Modification Record ...................................................................................................................... 8 2 TEST DETAILS ............................................................................................................................ 9 2.1 Maximum Conducted Output Power ........................................................................................... 10 2.2 Type of Emissions ...................................................................................................................... 12 2.3 Occupied Bandwidth ................................................................................................................... 14 2.4 Spuious Emissions at Antenna Terminals .................................................................................. 19 2.5 Emission Mask ............................................................................................................................ 30 2.6 Frequency Stability ..................................................................................................................... 36 2.7 Adjacent Channel Power ............................................................................................................ 39 2.8 Modulation Characteristics ......................................................................................................... 44 3 TEST EQUIPMENT USED ......................................................................................................... 45 3.1 Test Equipment Used ................................................................................................................. 46 3.2 Measurement Uncertainty .......................................................................................................... 48 4 ACCREDITATION, DISCLAIMERS AND COPYRIGHT ............................................................ 49 4.1 Accreditation, Disclaimers and Copyright ................................................................................... 50 Document 75930525 Report 01 Issue 1 Page 3 of 50 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE SECTION 1 REPORT SUMMARY FCC and Industry Canada Testing of the ETELM SAS NetisB25 In accordance with FCC 47 CFR Part 90, FCC 47 CFR Part 2 and Industry Canada RSS-119 Document 75930525 Report 01 Issue 1 Page 4 of 50 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE 1.1 INTRODUCTION The information contained in this report is intended to show the verification of FCC and Industry Canada Testing of the ETELM SAS NetisB25 to the requirements of FCC 47 CFR Part 90, FCC 47 CFR Part 2 and Industry Canada RSS-119. Objective To perform FCC and Industry Canada Testing to determine the Equipment Under Test's (EUT’s) compliance with the Test Specification, for the series of tests carried out. Manufacturer ETELM SAS Model Number(s) NETIS B25 Serial Number(s) 2000063 0361 Number of Samples Tested 1 Test Specification/Issue/Date FCC 47 CFR Part 90 (2014) FCC 47 CFR Part 2 (2014) Industry Canada RSS-119 (Issue 11, 2011) Incoming Release Date Application Form 22 May 2015 Disposal Reference Number Date Held Pending Disposal Not Applicable Not Applicable Order Number Date 7807 22 May 2015 Start of Test 22 June 2015 Finish of Test 25 June 2015 Name of Engineer(s) M Russell T Guy Related Document(s) ANSI C63.4: 2009 Document 75930525 Report 01 Issue 1 Page 5 of 50 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE 1.2 BRIEF SUMMARY O…
Text truncated - open the document above for the full version.
FCC ID: 0024845661 IC: 20543-BSTETRA800 ETELM NetisB25 Tetra Base Station ď›™2015 Not to be reproduced, except in its entirety, Page 1 of 3 without the Permission of TĂśV SĂśD Product Service Reference: 75930525 PHOTOGRAPHS OF TEST SET UP Conducted Measurements Radiated Emissions 30 MHz to 1 GHz FCC ID: 0024845661 IC: 20543-BSTETRA800 ETELM NetisB25 Tetra Base Station ď›™2015 Not to be reproduced, except in its entirety, Page 2 of 3 without the Permission of TĂśV SĂśD Product Service Reference: 75930525 Radiated Emissions 1 GHz to 5 GHz
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 90 | 854 MHz - 868.975 MHz | 25 W | 22K0DXW | 1.5000000000 ppm |