FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. NEOSEN ENERGY/
  3. 2AF63-IES3

2AF63-IES3Pivotal 20W wireless power transmitter

NEOSEN ENERGY
Pivotal 20W wireless power transmitter - FCC ID 2AF63-IES3 - NEOSEN ENERGY
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Jan 02, 2020
Application Purpose
Original Equipment
Date of Application
Jan 02, 2020
Equipment Note
Pivotal 20W wireless power transmitter
Frequency Range
0.11000000 - 0.20500000
Company
NEOSEN ENERGY
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

External Photos

External Photos ALL VIEW OF EUT TOP VIEW OF EUT BOTTOM VIEW OF EUT FRONT VIEW OF EUT BACK VIEW OF EUT LEFT VIEW OF EUT RIGHT VIEW OF EUT

ID Label/Location Info

FCC ID Label Location FCC ID: 2AF63-IES3 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Internal Photos

Internal Photos OPEN VIEW OF EUT-1 OPEN VIEW OF EUT-2 INTERNAL VIEW-1 OF EUT Antenna INTERNAL VIEW-2 OF EUT INTERNAL VIEW-3 OF EUT INTERNAL VIEW-4 OF EUT INTERNAL VIEW-5 OF EUT INTERNAL VIEW-6 OF EUT INTERNAL VIEW-7 OF EUT

Operational Description

Declaration concerning Antenna Specification It is hereby declared that the product Model No.: IES3 FCC ID: 2AF63-IES3 fulfills the requirement in FCC test relating to the antenna type. The device specified above confirms to the FCC recommendations for internal antenna type(s) described below: Type of antenna: Coil Antenna Gain of the antenna: 0dBi Frequency range: 110-205kHz The mounting of the antenna is fixed to the radio module and no other antenna should be used. Company name: NEOSEN ENERGY Address: 1506 CAPITAL AVE., SUITE 150, PLANO TX 75074, USA Place: PLANO Date: 2020-01-02 Signature:

RF Exposure Info

Page 1 of 13 RF Exposure Report Report No.: AGC00800191201EH03 FCC ID : 2AF63-IES3 APPLICATION PURPOSE : Original Equipment PRODUCT DESIGNATION : Pivotal 20W wireless power transmitter BRAND NAME : Pivotal Commware MODEL NAME : IES3 APLICANT : NEOSEN ENERGY DATE OF ISSUE : Dec. 12, 2019 STANDARD(S) : KDB 680106 D01 RF Exposure Wireless Charging Base App v03 REPORT VERSION : V1.0 Attestation of Global Compliance (Shenzhen) Co., Ltd CAUTION: This report shall not be reproduced except in full without the written permission of the test laboratory and shall not be quoted out of context. Report No.: AGC00800191201FH03 Page 2 of 13 REPORT REVISE RECORD Report Version Revise Time Issued Date Valid Version Notes V1.0 / Dec. 12, 2019 Valid Initial Release Report No.: AGC00800191201FH03 Page 3 of 13 TABLE OF CONTENTS 1. VERIFICATION OF CONFORMITY ............................................................................................................... 4 2. GENERAL INFORMATION ............................................................................................................................ 5 2.1. PRODUCT DESCRIPTION ..................................................................................................................... 5 3. DESCRIPTION OF TEST MODES................................................................................................................. 6 4. SYSTEM TEST CONFIGURATION ............................................................................................................... 6 5. TEST FACILITY ............................................................................................................................................. 7 6. RADIO FREQUENCY (RF) EXPOSURE TEST ............................................................................................. 8 6.1. LIMITS ..................................................................................................................................................... 8 6.2. TEST SETUP ........................................................................................................................................... 8 APPENDIX A: PHOTOGRAPHS OF TEST SETUP ......................................................................................... 11 Report No.: AGC00800191201FH03 Page 4 of 13 1. VERIFICATION OF CONFORMITY Applicant NEOSEN ENERGY Address 1506 CAPITAL AVE., SUITE 150, PLANO TX 75074 Manufacturer NEOSEN ENERGY Address 1506 CAPITAL AVE., SUITE 150, PLANO TX 75074 Factory Suga Electronics Address Suga High-tech Industrial Park, No. 8, Fulong Road, Sanzhong, Qingxi Town, Dongguan, Guangdong, PRC Product Designation Pivotal 20W wireless power transmitter Brand Name Pivotal Commware Test Model: IES3 Date of test Dec. 04, 2019~Dec. 12, 2019 Deviation None Condition of Test Sample Normal Report Template AGCRT-US-BR/RF We hereby certify that: The above equipment was tested by Attestation of Global Compliance (Shenzhen) Co., Ltd. The test data, data evaluation, test procedures, and equipment configurations shown in this report were made in accordance with the procedures given in KDB 680106 D01. The results of testing in this report apply to the product/system which was tested only. Prepared By Calvin Liu (Project Engineer) Dec. 12, 2019 Reviewed By Max Zhang (Reviewer) Dec. 12, 2019 Approved By Forrest Lei ( Authorized Officer) Dec. 12, 2019 Report No.: AGC00800191201FH03 Page 5 of 13 2. GENERAL INFORMATION 2.1. PRODUCT DESCRIPTION A major technical description of EUT is described as following Operation Frequency 110-205kHz Test Frequency 125.8kHz Maximum field strength 55.65dBuV/m(PK)@3m Modulation FSK Number of channels 1 Antenna Gain 0dBi Antenna Designation Coil Antenna Hardware Version OC7-11C_Pivotal-TX-p2 Software Version FW. Power Supply DC 24V 1.5A Report No.: AGC00800191201FH03 Page 6 of 13 3. DESCRIPTION OF TEST MODES NO. TEST MODE DESCRIPTION 1 Wireless charging Mode(Full load) 2 Wireless charging Mode(half load) 3 Wireless charging Mode(Null load) Note: 1. The mode 1 was the worst case and only the data of the worst case record in this report. 2. Both adaptors are tested and reported the worst-case data. 4. SYSTEM TEST CONFIGURATION Item Equipment Model No. ID or Specification Remark 1 Pivotal 20W wireless power transmitter IES3 2AF63-IES3 EUT 2 Load N/A 10W Accessory 3 Adapter PPL36U-240(PV) DC 24V 1.5A Accessory Report No.: AGC00800191201FH03 Page 7 of 13 5. TEST FACILITY TEST EQUIPMENT LIST Description Manufacturer Model S/N Cal. Date Cal. Due Broadband Field Meter Narda Safety Test Solutions GmbH NBM-550 J-0004 Jun.12, 2019 Jun.11, 2020 Probe FHP Narda Safety Test Solutions GmbH EHP-50F J-0015 Jun.12, 2019 Jun.11, 2020 Broadband Field Meter Narda Safety Test Solutions GmbH ELT-400 J-0003 Jun.12, 2019 Jun.11, 2020 Test Site Attestation of Global Compliance (Shenzhen) Co., Ltd Location 1-2/F, Building 19, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Designation Number CN1259 FCC Test Firm Registration Number 975832 A2LA Cert. No. 5054.02 Description Attestation of Global Compliance(Shenzhen) Co., Ltd is accredited by A2LA Report No.: AGC00800191201FH03 Page 8 of 13 6. RADIO FREQUENCY (RF) EXPOSURE TEST 6.1. LIMITS For devices designed for typical desktop applications, such a wireless charging pads, RF exposure evaluation should be conducted assuming a user separation distance of 15 cm. E and H field strength measurements or numerical modeling may be used to demonstrate compliance. Measurements should be made from all sides and the top of the primary/client pair, with the 15 cm measured from the center of the probe(s) to the edge of the device. Emissions between 100 kHz to 300 kHz should be assessed versus the limits at 300 kHz in Table 1 of Section 1.1310: 614 V/m and 1.63 A/m. 6.2. TEST SETUP Note: Position A: Front of EUT; Position B: Left of EUT; Position C: back of EUT; Position D: Right of …

Text truncated - open the document above for the full version.

Test Report

Page 1 of 31 FCC Test Report Report No.: AGC00800191201FE03 FCC ID : 2AF63-IES3 APPLICATION PURPOSE : Original Equipment PRODUCT DESIGNATION : Pivotal 20W wireless power transmitter BRAND NAME : Pivotal Commware MODEL NAME : IES3 APPLICANT : NEOSEN ENERGY DATE OF ISSUE : Dec. 12, 2019 STANDARD(S) TEST PROCEDURE(S) : FCC Part 15 Rules REPORT VERSION : V1.0 Attestation of Global Compliance (Shenzhen) Co., Ltd CAUTION: This report shall not be reproduced except in full without the written permission of the test laboratory and shall not be quoted out of context. Report No.: AGC00800191201FE03 Page 2 of 31 REPORT REVISE RECORD Report Version Revise Time Issued Date Valid Version Notes V1.0 / Dec. 12, 2019 Valid Initial Release Report No.: AGC00800191201FE03 Page 3 of 31 TABLE OF CONTENTS 1. VERIFICATION OF CONFORMITY ............................................................................................................... 4 2. GENERAL INFORMATION ............................................................................................................................ 5 2.1. PRODUCT DESCRIPTION ..................................................................................................................... 5 3. MEASUREMENT UNCERTAINTY ................................................................................................................. 6 4. DESCRIPTION OF TEST MODES ................................................................................................................. 7 5. SYSTEM TEST CONFIGURATION ............................................................................................................... 8 5.1. CONFIGURATION OF EUT SYSTEM ..................................................................................................... 8 5.2. EQUIPMENT USED IN EUT SYSTEM ..................................................................................................... 8 5.3. SUMMARY OF TEST RESULTS .............................................................................................................. 8 6. TEST FACILITY ............................................................................................................................................. 9 7. RADIATED EMISSION ................................................................................................................................. 10 7.1TEST LIMIT ............................................................................................................................................. 10 7.2. MEASUREMENT PROCEDURE ............................................................................................................ 11 7.3. TEST SETUP ......................................................................................................................................... 12 7.4. TEST RESULT ....................................................................................................................................... 13 8. 20DB BANDWIDTH ..................................................................................................................................... 16 8.1. MEASUREMENT PROCEDURE ........................................................................................................... 16 8.2. TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) ................................................................... 16 8.3. MEASUREMENT RESULTS .................................................................................................................. 17 APPENDIX A: PHOTOGRAPHS OF TEST SETUP ........................................................................................ 18 APPENDIX B: PHOTOGRAPHS OF EUT ....................................................................................................... 24 Report No.: AGC00800191201FE03 Page 4 of 31 1. VERIFICATION OF CONFORMITY Applicant NEOSEN ENERGY Address 1506 CAPITAL AVE., SUITE 150, PLANO TX 75074 Manufacturer NEOSEN ENERGY Address 1506 CAPITAL AVE., SUITE 150, PLANO TX 75074 Factory Suga Electronics Address Suga High-tech Industrial Park, No. 8, Fulong Road, Sanzhong, Qingxi Town, Dongguan, Guangdong, PRC Product Designation Pivotal 20W wireless power transmitter Brand Name Pivotal Commware Test Model IES3 Date of test Dec. 04, 2019~Dec. 12, 2019 Deviation No any deviation from the test method. Condition of Test Sample Normal Test Result Pass Report Template AGCRT-US-BR/RF We hereby certify that: The above equipment was tested by Attestation of Global Compliance (Shenzhen) Co., Ltd. The test data, data evaluation, test procedures, and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.10 (2013) and the energy emitted by the sample EUT tested as described in this report is in compliance with Section 15.207, 15.209, 15.203 of the FCC Part 15, Subpart C Rules. The results of testing in this report apply to the product/system which was tested only. Prepared By Calvin Liu (Project Engineer) Dec. 12, 2019 Reviewed By Max Zhang (Reviewer) Dec. 12, 2019 Approved By Forrest Lei ( Authorized Officer) Dec. 12, 2019 Report No.: AGC00800191201FE03 Page 5 of 31 2. GENERAL INFORMATION 2.1. PRODUCT DESCRIPTION A major technical description of EUT is described as following Operation Frequency 110-205kHz Test Frequency 125.8kHz Maximum field strength 55.65dBuV/m(PK)@3m Modulation FSK Number of channels 1 Antenna Gain 0dBi Antenna Designation Coil Antenna Hardware Version OC7-11C_Pivotal-TX-p2 Software Version FW. Power Supply DC 24V 1.5A Report No.: AGC00800191201FE03 Page 6 of 31 3. MEASUREMENT UNCERTAINTY The uncertainty is calculated using the methods suggested in the “Guide to the Expression of Uncertainty in measurement” (GUM) published by CISPR and ANSI. - Uncertainty of Conducted Emission, Uc = ±3.2 dB - Uncertainty of Radiated Emission below 1GHz, Uc = ±3.9 dB - Uncertainty of Radiated Emission above 1GHz, Uc = ±4.8 dB Report No…

Text truncated - open the document above for the full version.

Test Setup Photos

Test Setup Photos FCC RADIATED EMISSION TEST SETUP BELOW 1GHZ FCC LINE CONDUCTED EMISSION TEST SETUP

Contact Information

Applicant

PAUL GARRITY(CEO)
[email protected]2148028294Fax: 2148028294

Test Firm

Attestation of Global Compliance (Shenzhen) Co., LDoris Li
[email protected]+86-755-25234088

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.11 MHz - 0.205 MHz-
Confidentiality
Long Term

Other Applications from NEOSEN ENERGY

OEM Module(Wireless Charging) - FCC ID 2AF63DUPONT - NEOSEN ENERGY
2AF63DUPONT

OEM Module(Wireless Charging)

Nov 22, 2015

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz