
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Remote control for Personal Power Plate This Remote Control only operate the Personal Power Plate machine When press the Start/Stop button the first time, the machine starts up. When press the Start/Stop button again, the machine stops. When press the Time button the first time, it changes the machine time setting to 30sec. When press the Time button again, it changes the machine time setting to 60sec. When press the Low/High button the first time, it changes the machine amplitude setting to Low. When press the Low/High button again, it changes the machine amplitude amplitude setting to High When the user completes the first cycle of exercise, then press the Repeat Button, the machine will start up with the previous setting of Time & Low/High amplitude. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures.
SCS-F18: Project and Product Certification Representative Authorization Letter Page 1 of 2 Rev 5.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Project and Product Certification Representative Authorization Letter Reason for Amendment (current / obsolete) Revision History Approved Date From To Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Revised wording (obsolete) 1.0 2.0 Sept–25-2007 Updated company template (obsolete) 2.0 3.0 Jan-31-2012 Updated letter information (obsolete) 3.0 4.0 May-23-2014 Added FCC ID field (current) 4.0 5.0 Sept 16 2014 SCS-F18: Project and Product Certification Representative Authorization Letter Page 2 of 2 Rev 5.0 Performance Health Systems UK LTD 2015/9/29 To: SIEMIC, INC. 775 Montague Expressway, Milpitas, CA 95035 USA Dear Sir/Madam, Re: Product Certification Representative Authorization Letter We, Performance Health Systems UK LTD hereby authorize SIEMIC, Inc. to act as a Certification Body for certifying for the following project(s): Product description: Remote control for Personal Power Plate model name: Remote control for Personal Power Plate FCC ID: 2AF6VREMOTE Sincerely, Client’s signature Client’s name / title : Elizabeth Bruce /manager Contact information / address: The Perfume Factory, Unit G-11, 140 Wales Farm Road, London, W3 6UG
SCS-F19: Confidentiality Request Letter Page 1 of 2 Rev 4.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526- 1188 Fax: 408-526-1088 Email: [email protected] Confidentiality Request Letter Reason for Amendment (current / obsolete) Revision History Approved Date From To Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Adding CFR 2.459 (obsolete) 1.0 2.0 August – 11 - 2008 Updated company template & Added text box (obsolete) 2.0 3.0 Jan-31-2012 Added IC confidentiality letter form (current) 3.0 4.0 March-26-2015 SCS-F19: Confidentiality Request Letter Page 2 of 2 Rev 4.0 Performance Health Systems UK LTD 2015/9/29 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Subject: Permanent Confidentiality Request for FCC ID: 2AF6VREMOTE We hereby request confidential treatment of information accompanying this application as outlined below: - Block Diagram - Schematics - Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Client’s signature Client’s name / title : Elizabeth Bruce /manager Contact information / address: The Perfume Factory, Unit G-11, 140 Wales Farm Road, London, W3 6UG
Shenzhen BCTC Technology Co., Ltd. FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page1 of 5 APPENDIX-PHOTOGRAPHS OF EUT CONSTRUCTIONAL DETAILS Photo 1 Photo 2 Shenzhen BCTC Technology Co., Ltd. FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page2 of 5 Photo 3 Photo 4 Shenzhen BCTC Technology Co., Ltd. FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page3 of 5 Photo 5 Photo 6
Model: Remote control for Personal Power Plate FCC ID: 2AF6VREMOTE Performance Health Systems UK LTD
Shenzhen BCTC Technology Co., Ltd. FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page4 of 5 Photo 7 Photo 8 Shenzhen BCTC Technology Co., Ltd. FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page5 of 5 Photo 9 Photo 10 Antenna location
Shenzhen BCTC Technology Co., Ltd. Report No.: BCTC-150911806 FCC Part 15C Test Report FCC ID: 2AF6VREMOTE Product Name: Remote control for Personal Power Plate Trademark: Model Name : Remote control for Personal Power Plate Prepared For : Performance Health Systems UK LTD Address : The Perfume Factory, Unit G-11, 140 Wales Farm Road, London, W3 6UG Prepared By : Shenzhen BCTC Technology Co., Ltd. Address : No.101,Yousong Road,Longhua New District, Shenzhen,China Test Date: Sep 23 – Sep 30, 2015 Date of Report : Sep 30, 2015 Report No.: BCTC-150911806 Shenzhen BCTC Technology Co., Ltd. Report No.: BCTC-150911806 FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page 2 of 38 VERIFICATION OF COMPLIANCE Applicant’s name ................. : Performance Health Systems UK LTD Address ................................. : The Perfume Factory, Unit G-11, 140 Wales Farm Road, London, W3 6UG Manufacture's Name ............ : Performance Health Systems UK LTD Address ................................. : The Perfume Factory, Unit G-11, 140 Wales Farm Road, London, W3 6UG Product description Product name ............................ : Remote control for Personal Power Plate Trademark: Model Name: Remote control for Personal Power Plate Test procedure FCC Part15.231 Standards ANSI C63.10-2013 This device described above has been tested by BCTC, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of BCTC, this document may be altered or revised by BCTC, personal only, and shall be noted in the revision of the document. Test Result.............................................. : Pass Testing Engineer : (Eric Yang) Technical Manager : (Sophia Lee) Authorized Signatory : (Carson. Zhang) Table of Contents Page Shenzhen BCTC Technology Co., Ltd. Report No.: BCTC-150911806 FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page 3 of 38 Table of Contents Page 1 . SUMMARY OF TEST RESULTS 5 1.1 TEST FACILITY 6 1.2 MEASUREMENT UNCERTAINTY 6 2 . GENERAL INFORMATION 7 2.1 GENERAL DESCRIPTION OF EUT 7 2.2 DESCRIPTION OF TEST MODES 8 2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 8 2.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE) 8 2.5 EQUIPMENTS LIST FOR ALL TEST ITEMS 9 3 . EMC EMISSION TEST 10 3.1 CONDUCTED EMISSION MEASUREMENT 10 3.1.1 POWER LINE CONDUCTED EMISSION LIMITS 10 3.1.2 TEST PROCEDURE 11 3.1.3 DEVIATION FROM TEST STANDARD 11 3.1.4 TEST SETUP 11 3.1.5 EUT OPERATING CONDITIONS 11 3.1.6 TEST RESULTS 12 3.2 RADIATED EMISSION MEASUREMENT 13 3.2.1 RADIATED EMISSION LIMITS 13 3.2.2 TEST PROCEDURE 14 3.2.3 TEST SETUP 15 3.2.4 EUT OPERATING CONDITIONS 16 3.2.5 TEST RESULTS 17 4 . BANDWIDTH TEST 24 4.1 APPLIED PROCEDURES / LIMIT 24 4.1.1 TEST PROCEDURE 24 4.1.2 DEVIATION FROM STANDARD 24 4.1.3 TEST SETUP 24 4.1.4 EUT OPERATION CONDITIONS 24 4.1.5 TEST RESULTS 25 5 . CALCULATION OF AVERAGE FACTOR 28 6 . DWELL TIME 31 6.1 DEVIATION FROM STANDARD 31 6.2 TEST SETUP 31 6.3 EUT OPERATION CONDITIONS 31 Shenzhen BCTC Technology Co., Ltd. Report No.: BCTC-150911806 FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page 4 of 38 Table of Contents Page 6.4 TEST RESULTS 32 7 . ANTENNA REQUIREMENT 36 7.1 STANDARD REQUIREMENT 36 7.2 EUT ANTENNA 36 8 . EUT TEST PHOTO 37 APPENDIX-PHOTOGRAPHS OF EUT CONSTRUCTIONAL DETAILS Shenzhen BCTC Technology Co., Ltd. Report No.: BCTC-150911806 FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page 5 of 38 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15 (15.231) , Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission N/A 15.209,15.231b Fundamental &Radiated Spurious Emission Measurement PASS 15.231c Occupy Bandwidth PASS 15.231a Dwell time PASS 15.203 Antenna Requirement PASS NOTE: (1)” N/A” denotes test is not applicable in this Test Report Shenzhen BCTC Technology Co., Ltd. Report No.: BCTC-150911806 FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page 6 of 38 1.1 TEST FACILITY Shenzhen BCTC Technology Co., Ltd. Add.:No.101,Yousong Road,Longhua New District, Shenzhen,China FCC Registration No.:187086 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %。 No. Item Uncertainty 1 Conducted Emission Test ±1.38dB 2 RF power,conducted ±0.16dB 3 Spurious emissions,conducted ±0.21dB 4 All emissions,radiated(<1G) ±4.68dB 5 All emissions,radiated(>1G) ±4.89dB 6 Temperature ±0.5°C 7 Humidity ±2% Shenzhen BCTC Technology Co., Ltd. Report No.: BCTC-150911806 FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page 7 of 38 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF EUT Equipment Remote control for Personal Power Plate Trade Name Model Name Remote control for Personal Power Plate Serial Model N/A Model Difference N/A Product Description The EUT is a Remote control for Personal Power Plate Operation Frequency: 433.92MHz Modulation Type: ASK Antenna Designation: PCB Antenna Gain 1.7dBi Based on the application, features, or specification exhibited in User's Manual, the EUT is considered as an ITE/Computing Device. More details of EUT technical specification, please refer to the User's Manual. Battery DC 6V Connecting I/O Port(s) Please refer to the User's Manual Note: 1. For a more detailed features description, please refer to the manufacturer’s specifications or the User's Manual. Shenzhen BCTC Technology Co., Ltd. Report No.: BCTC-150911806 FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page 8 of 38 2.2 DESCRIPTION OF TEST MODES For All Emission Final Test Mode Description Mode 1 TX Mode(Start/Stop) M…
Text truncated - open the document above for the full version.
Shenzhen BCTC Technology Co., Ltd. Report No.: BCTC-15020059 FCC Report Tel: 400-788-9558 0755-33019988 Web:Http//www.bctc-lab.com Page 30 of 31 8. EUT TEST PHOTO Radiated Measurement Photos
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.92 MHz - 433.92 MHz | - |